• Title/Summary/Keyword: Testing & Evaluation Method

Search Result 1,052, Processing Time 0.032 seconds

Assessment of Atmospheric Greenhouse Gas Concentration Equipment Performance (대기 중 온실가스 농도 관측 장비 성능 비교 검증)

  • Chaerin Park;Sujong Jeong;Seung-Hyun Jeong;Jeong-il Lee;Insun Kim;Cheol-Soo Lim
    • Atmosphere
    • /
    • v.33 no.5
    • /
    • pp.549-560
    • /
    • 2023
  • This study evaluates three distinct observation methods, CRDS, OA-ICOS, and OF-CEAS, in greenhouse gas monitoring equipment for atmospheric CO2 and CH4 concentrations. The assessment encompasses fundamental performance, high-concentration measurement accuracy, calibration methods, and the impact of atmospheric humidity on measurement accuracy. Results indicate that within a range of approximately 500 ppm, all three devices demonstrate high accuracy and linearity. However, beyond 1000 ppm, CO2 accuracy sharply declines (84%), emphasizing the need for caution when interpreting high-concentration CO2 data. An analysis of calibration methods reveals that both CO2 and CH4 measurements achieve high accuracy and linearity through 1-point calibration, suggesting that multi-point calibration is not imperative for precision. In dynamic atmospheric conditions with significant CO2 and CH4 concentration variations, a 1-point calibration suffices for reliable data (99% accuracy). The evaluation of humidity impact demonstrates that humidity removal devices significantly reduce air moisture levels, yet this has a negligible effect on dry CO2 concentrations (less than 0.5% relative error). All three observation method instruments, which have integrated humidity correction to calculate dry CO2 concentrations, exhibit minor sensitivity to humidity removal devices, implying that additional removal devices may not be essential. Consequently, this study offers valuable insights for comparing data from different measurement devices and provides crucial information to consider in the operation of monitoring sites.

Occurrence and Multiplex PCR Detection of Citrus Yellow Vein Clearing Virus in Korea

  • Taemin Jin;Ji-Kwang Kim;Hee-Seong Byun;Hong-Soo Choi;Byeongjin Cha;Hae-Ryun Kwak;Mikyeong Kim
    • The Plant Pathology Journal
    • /
    • v.40 no.2
    • /
    • pp.125-138
    • /
    • 2024
  • Citrus yellow vein clearing virus (CYVCV) is a member of the Alphaflexiviridae family that causes yellow vein clearing symptoms on citrus leaves. A total of 118 leaf samples from nine regions of six provinces in Korea were collected from various citrus species in 2020 and 2021. Viral diagnosis using next-generation sequencing and reverse transcription polymerase chain reaction (RT-PCR) identified four viruses: citrus tristeza virus, citrus leaf blotch virus, citrus vein enation virus, and CYVCV. A CYVCV incidence of 9.3% was observed in six host plants, including calamansi, kumquat, Persian lime, and Eureka lemon. Among the citrus infected by CYVCV, only three samples showed a single infection; the other showed a mixed infection with other viruses. Eureka lemon and Persian lime exhibited yellow vein clearing, leaf distortion, and water-soak symptom underside of the leaves, while the other hosts showed only yellowing symptoms on the leaves. The complete genome sequences were obtained from five CYVCV isolates. Comparison of the isolates reported from the different geographical regions and hosts revealed the high sequence identity (95.2% to 98.8%). Phylogenetic analysis indicated that all the five isolates from Korea were clustered into same clade but were not distinctly apart from isolates from China, Pakistan, India, and Türkiye. To develop an efficient diagnosis system for the four viruses, a simultaneous detection method was constructed using multiplex RT-PCR. Sensitivity evaluation, simplex RT-PCR, and stability testing were conducted to verify the multiplex RT-PCR system developed in this study. This information will be useful for developing effective disease management strategies for citrus growers in Korea.

Vibration testing using the movement of a 60ton crane for the evaluation the stability of nearby stone cultural heritage. (60톤 크레인의 주행 진동 실험을 통한 인접 석조 문화재의 안정성 평가)

  • Lee, Ga-Yoon;Ra, Young-Eun;Lee, Jong-Hak;Lee, Sung-Min;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.1
    • /
    • pp.47-55
    • /
    • 2024
  • The aim of this study is to evaluate the possibility of damage to cultural assets resulting from vibrations generated by construction vehicle traffic. The cultural heritage's natural vibration frequency was determined to be 150Hz by measurement. The damping ratios were calculated as 4.7% using the logarithmic decrement approach and 4.3% using the half-power method. The vibration measurements obtained during vehicle operation indicated that, despite an increase in vehicle velocity of up to 15 km/h, the vibrations remained below the detectable level of 0.13 mm/sec. When the road is curved and the terrain is sloped, a suitable speed for vehicle operation was found to be around 17 km/h, at which point vibrations were seen. The highest recorded vibration amplitude at this velocity was 0.217 mm/sec, which remains below the stringent regulation limit of 2 mm/sec. Thus, it can be concluded that there is no actual harm caused by vibrations.

The New in vitro Oral Irritation Test Method for Toothpaste using YD-38 Oral Mucosal Cell Line (치약에 대한 YD-38 세포주를 활용한 새로운 구강 점막 자극 시험방법)

  • Nam, Gi Baeg;Cho, Sun-A;Cho, Jun-Cheol;Kim, Chanho;Kim, Yoo-Jin;Lee, John Hwan;Shin, Kyeho
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.38 no.4
    • /
    • pp.305-310
    • /
    • 2012
  • Through our entire life, oral care products such as toothpaste are used. Thus the safety of oral care products used every day to our mouth is very important. As the previous study in animal tests or clinical trials, surfactant in toothpaste may cause the oral irritation. However, EU cosmetics legislation prohibits animal testing of cosmetics and its ingredient for animal welfare. Therefore the development of alternative in vitro test has been actively performed to replace or reduce using the animal in many areas. However, the way to evaluate oral mucosal toxicity has been done using animal models or clinical trials from now on. Even more, the experiment with human oral 3D tissue or human oral cell line is used recently. The aim of this study is the development of oral mucosal irritation method without using animal for the safety of the oral care product. We developed in vitro test method for oral irritation by using human oral cell line (YD-38 cell) acceptable to toothpaste which contains insoluble material. By the results of this assay, we could discriminate toothpaste with or without irritating substance as same manner in animal studies reported previously. In addition, we confirmed that toothpaste for babies and children toothpaste irritated oral musoca lower than the general adult toothpaste. The present study suggest that this new in vitro method by using human oral cell line (YD-38 cell) could be used for evaluation of oral irritation without using animal.

Seismic Capacity Evaluation of Existing Medium-and low-rise R/C Frame Retrofitted by H-section Steel Frame with Elastic Pad Based on Pseudo-dynamic testing (유사동적실험에 의한 탄성패드 접합 H형 철골프레임공법으로 보강 된 기존 중·저층 R/C 골조의 내진성능 평가)

  • Kim, Jin-Seon;Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.83-91
    • /
    • 2021
  • In this study, to improve the connection performance between the existing reinforced concrete (R/C) frame and the strengthening member, we proposed a new H-section steel frame with elastic pad (HSFEP) system for seismic rehabilitation of existing medium-to-low-rise reinforced concrete (R/C) buildings. This HSFEP strengthening system exhibits an excellent connection performance because an elastic pad is installed between the existing structure and reinforcing frame. The method shows a strength design approach implemented via retrofitting, to easily increase the ultimate lateral load capacity of R/C buildings lacking seismic data, which exhibit shear failure mechanism. Two full-size two-story R/C frame specimens were designed based on an existing R/C building in Korea lacking seismic data, and then strengthened using the HSFEP system; thus, one control specimen and one specimen strengthened with the HSFEP system were used. Pseudodynamic tests were conducted to verify the effects of seismic retrofitting, and the earthquake response behavior with use of the proposed method, in terms of the maximum response strength, response displacement, and degree of earthquake damage compared with the control R/C frame. Test results revealed that the proposed HSFEP strengthening method, internally applied to the R/C frame, effectively increased the lateral ultimate strength, resulting in reduced response displacement of R/C structures under large scale earthquake conditions.

The Assessment of the Breath Hold and the Free Breath Methods about the Blood Flow Evaluation by Using Phase Contrast MRI (위상대조도 자기공명영상을 이용한 심장 혈류평가에 있어서 호흡정지 기법과 비 호흡정지 기법의 비교평가)

  • Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.149-156
    • /
    • 2016
  • Measurement of cardiac blood flow using the magnetic resonance imaging has been limited due to breathing and involuntary movements of the heart. The present study attempted to improve the accuracy of cardiac blood flow testing through phase contrast magnetic resonance imaging by presenting the adequate breathing method and imaging variables by comparing the measurement values of cardiac blood flow. Each was evaluated by comparing the breath hold retrospective 1NEX and non breath hold retrospective 1-3NEX in the ascending aorta and descending aorta. As a result, the average blood flow amount/velocity of the breath hold retrosepctive 1NEX method in the ascending aorta were $96.17{\pm}19.12ml/sec$, $17.04{\pm}4.12cm/sec$ respectively, which demonstrates a statistically significant difference(p<0.05) with the non-breath hold retrospective method 1NEX of $72.31{\pm}13.27ml$ and $12.32{\pm}3.85$. On the other hand, the average 2NEX blood flow and mean flow velocity is $101.90{\pm}24.09$, $16.84{\pm}4.32$, 3NEX $103.06{\pm}25.49$, $16.88{\pm}4.19$ did not show statistically significant differences(p>0.05).The average blood flow amount/ velocity of the breath hold retrospective 1NEX method in the descending aorta were $76.68{\pm}19.72ml/s$, and $22.23{\pm}4.8$, which did not demonstrate a significant difference in comparison to non-breath hold retrospective method 1-3 NEX. Therefore, the non breath hold retrospective method does not significantly differ in terms of cardiac blood flow in comparison with the breath hold retrospective method in accordance with the increase of NEX, so pediatric patients or patients who are not able to breathe well must have the diagnostic value of their cardiac blood flow tests improved.

Development of Evaluation Method for Jointed Concrete Pavement with FWD and Finite Element Analysis (FWD와 유한요소해석을 이용한 줄눈콘크리트포장 평가법 개발)

  • Yun, Kyong-Ku;Lee, Joo-Hyung;Choi, Seong-Yong
    • International Journal of Highway Engineering
    • /
    • v.1 no.1
    • /
    • pp.107-119
    • /
    • 1999
  • The joints in the jointed concrete pavement provide a control against transverse or longitudinal cracking at slab, which may be caused by temperature or moisture variation during or after hydration. Without control of cracking, random cracks cause more serious distresses and result in structural or functional failure of pavement system. However, joints nay cause distresses due to its inherent weakness in structural integrity. Thus, the evaluation at joint is very important. and the joint-related distresses should be evaluated reasonably for economic rehabilitation. The purpose of this paper was to develop an evaluation system at joints of jointed concrete pavement using finite element analysis program, ILLI-SLAB, and nondestructive testing device. FWD. To develop an evaluation system for JCP, a sensitivity analysis was performed using ILLI-SLAB program with a selected variables which might affect fairly to on the performance of transverse joints. The most significant variables were selected from precise analysis. An evaluation charts were made for jointed concrete pavement by adopting the field FWD data. It was concluded that the variables which most significantly affect to pavement deflections are the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G), and limiting criteria on the performance of joints at JCP are 300pci. 500,000 lb/in. respectively. Using these variables and FWD test, a charts of load transfer ratio versus surface deflection at joints were made in order to evaluate the performance of JCP. Practically, Chungbu highway was evaluated by these evaluation charts and FWD field data for jointed concrete pavement. For Chungbu highway, only one joint showed smaller value than limiting criterion of the modulus of dowel/concrete interaction(G). The rest joints showed larger values than limiting criteria of the modulus of subgrade reaction(K) and the modulus of dowel/concrete interaction(G).

  • PDF

Evaluation of Available Soil Silicon Extracting Procedures for Oriental Melon (참외 시설재배 토양에 대한 유효규산 추출방법 비교)

  • Cho, Hyun-Jong;Choe, Hui-Yeol;Lee, Yong-Woo;Chung, Jong-Bae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.4
    • /
    • pp.251-258
    • /
    • 2004
  • Soil testing for silicon (Si) in the upland soils has not been sufficiently investigated. The objective of this study was to identify a suitable Si extraction method for upland soils of oriental melon (Cucumis melo L.). Thirty-eight surface soil samples and matured leaf samples were collected from plastic film houses in Sungju, Gyeongbuk province. In the laboratory, six different methods were used for extracting Si from the soils. The methods included 0.5 N HCl extraction, 1 N sodium acetate buffer (PH 4.0) extraction, citric acid 1% extraction, water extraction, Tiis buffer pH 7.0 extraction, and extraction after incubation with water for 1 week. The concentration of dissolved Si in soil extracts from all methods was determined colorimetrically. With 1 N sodium acetate buffer extraction, as the available soil Si increased, the concentration ofSi in oriental melon leaf increased until around $14g\;SiO_2\;kg^{-1}$ was reached in the form of a saturation curve. Also, among the methods studied, extraction with 1 N sodium acetate buffer was the only method provided a significant linear correlation with oriental melon leaf Si content in the range of extractable soil Si lower than the level which inducing Si saturation in oriental melon leaf. These results indicate that 1 N sodium acetate buffer extraction procedure is the best soil Si test method for upland soils of oriental melon. This sodium acetate buffer extraction procedure is rapid and quite well acquainted with scientists and farmers, since the method has been used for routine paddy soil testing.

Significance Evaluation of Lung Volume and Pulmonary Dysfunction (폐용적과 폐기능 환기장애에 대한 유의성 평가)

  • Ji-Yul Kim;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.767-773
    • /
    • 2023
  • To In this study, we sought to evaluate related factors affecting lung volume and their significance in pulmonary function and ventilation disorders. As experimental subjects, 206 normal adult men and women who underwent a low-dose chest CT scan and a spirometry test were selected at the same time. The experimental method was to measure lung volume using lung CT images obtained through a low-dose chest CT scan using deep learning-based AVIEW. Measurements were made using the LCS automatic diagnosis program. In addition, the results of measuring lung function were obtained using a spirometer, and gender and BMI were selected as related factors that affect lung volume, and significance was evaluated through an independent sample T-test with lung volume. As a result of the experiment, it was confirmed that in evaluating lung volume according to gender, all lung volumes of men were larger than all lung volumes of women. he result of an independent samples T-test using the respective average values for gender and lung volume showed that all lung volumes were larger in men than in women, which was significant (p<0.001). And in the evaluation of lung volume according to BMI index, it was confirmed that all lung volumes of adults with a BMI index of 24 or higher were larger than all lung volumes of adults with a BMI index of less than 24. However, the independent samples T-test using the respective average values for BMI index and lung volume did not show a significant result that all lung volumes were larger in BMI index 24 or higher than in BMI index less than 24 (p<0.055). In the evaluation of lung volume according to the presence or absence of pulmonary ventilation impairment, it was confirmed that all lung volumes of adults with normal pulmonary function ventilation were larger than all lung volumes of adults with pulmonary ventilation impairment. And as a result of the independent sample T-test using the respective average values for the presence or absence of pulmonary ventilation disorder and lung volume, the result was significant that all lung volumes were larger in adults with normal pulmonary function ventilation than in adults with pulmonary function ventilation disorder (p <0.001). Lung volume and spirometry test results are the most important indicators in evaluating lung health, and using these two indicators together to evaluate lung function is the most accurate evaluation method. Therefore, it is expected that this study will be used as basic data by presenting the average lung volume for adults with normal ventilation and adults with impaired lung function and ventilation in similar future studies on lung volume and vital capacity testing.

Evaluation of Efficacy and Risk of Intradermal Skin Testing for Antibiotic Pharmacotherapy in Hospital of Korea (한국 병원의 항생제 치료를 위한 항생제피부반응시험에 대한 유효성 및 위험성 평가)

  • Kim, Kyeong Ha;Lee, Yun Jeong;Lim, Sung Cil
    • YAKHAK HOEJI
    • /
    • v.58 no.4
    • /
    • pp.229-244
    • /
    • 2014
  • Background: Antibiotic skin test(AST) is very useful for the diagnosis of drug allergies to prevent immediate allergic reactions. Although it is a safe and widespread method, it is performed very diversely by doctors and nurses without consistency and it also differs from countries and hospitals. This study aims to evaluate the current practice of AST by nurses in Korea and to compare it to the general guidelines. Methods: During January 1, 2013 to May 20, 2013, the study was conducted as questionnaires and case-based survey. The questionnaires were given to the nurses who were randomly selected in various University Hospitals (University Hospitals N=276, and Medical center N=19). The case-based surveys were given to the nurses who were conducting AST at various wards of a University Hospital (N=130). The analysis and evaluations of the responses were carried out. Results: The response rate for the questionnaires was 97.6% and 130 cases of the actual case-based surveys were collected. There were clear differences between the survey results and the general guidelines, such as the method of skin test (skin prick test was not conducted), the method of patient selection for AST, test drugs, concentration, volume and interpretation of AST. AST conducted by nurses was highly variable and inconsistent, even among nurses who worked in the same wards and hospitals. Manufactured standard concentration antibiotic solution of AST showed consistency of concentration to a certain degree. Conclusion: Although the general guidelines have been published by several countries including Korea, these are not a great help to nurses as they lack details for conducting AST, practical consideration for nurses in the clinical setting, propagation and education. Standardized guideline for nurses should be published and it should be a safe, clear, comfortable and easily accessible protocol. Futhermore, additional antibiotic solutions to standardize skin test should be developed and manufactured. Lastly, it would be the pharmacists role to compare their hospitals antibiotic skin test methods with the standard guidelines and develop a protocol within the hospital for patients' safety, and to strive to consistently implement it.