• Title/Summary/Keyword: Testing & Evaluation Method

Search Result 1,052, Processing Time 0.033 seconds

Evaluation of Microscopic Deformation Behaviors of Metal Matrix Composite due to Heat Treatment by means of SFC Test and Acoustic Emission (음향방출과 SFC 시험법에 의한 금속복합재료의 기지재 열처리 효과에 따른 미시적 변형기구 특성 평가)

  • Kang, Moon-Phil;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.5
    • /
    • pp.381-389
    • /
    • 2000
  • Metal matrix composite(MMCs) have been rapidly becoming one of the strongest candidates for structural materials for high temperature application. It is well recognized that MMCs always experience at least one large cool-down from processing temperature before my significant applied service loading. Due to the large difference in thermal expansion coefficient between the fiber and matrix, large thermal residual stresses generally develop in composites. It was reported from many previous studies that the effects of thermal residual stress on mechanical properties and fracture behavior were much more complex and dramatic than conventional engineering materials. Therefore it is crucial to evaluate the effect of heat treatment which changes the characteristic of distribution of thermal residual stress in MMCs. Single fiber composite(SFC) test based on the balance in a micromechanical model is a quite convenient method to evaluate interfacial shear strength(IFSS) and the failure mode of composite. In this study the effect of heat treatment on IFSS and the microscopic failure mechanism of MMC is investigated by combining acoustic emission(AE) technique with SFC test. The characteristic of AE signal, IFSS and microscopic failure mechanism due to heat treatment condition is discussed.

  • PDF

Development of Nondestructive Sorting Method for Brown Bloody Eggs Using VIS/NIR Spectroscopy (가시광 및 근적외선 전투과 스펙트럼을 이용한 갈색 혈란 비파괴선별 방법 개발)

  • Lee, Hong-Seock;Kim, Dae-Yong;Kandpal, Lalit Mohan;Lee, Sang-Dae;Mo, Changyeun;Hong, Soon-Jung;Cho, Byoung-Kwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.31-37
    • /
    • 2014
  • The aim of this study was the non-destructive evaluation of bloody eggs using VIS/NIR spectroscopy. The bloody egg samples used to develop the sorting mode were produced by injecting chicken blood into the edges of egg yolks. Blood amounts of 0.1, 0.7, 0.04, and 0.01 mL were used for the bloody egg samples. The wavelength range for the VIS/NIR spectroscopy was 471 to 1154 nm, and the spectral resolution was 1.5nm. For the measurement system, the position of the light source was set to $30^{\circ}$, and the distance between the light source and samples was set to 100 mm. The minimum exposure time of the light source was set to 30 ms to ensure the fast sorting of bloody eggs and prevent heating damage of the egg samples. Partial least squares-discriminant analysis (PLS-DA) was used for the spectral data obtained from VIS/NIR spectroscopy. The classification accuracies of the sorting models developed with blood samples of 0.1, 0.07, 0.04, and 0.01 mL were 97.9%, 98.9%, 94.8%, and 86.45%, respectively. In this study, a novel nondestructive sorting technique was developed to detect bloody brown eggs using spectral data obtained from VIS/NIR spectroscopy.

Cervical Cancer Prevention for the Future: the Complimentary Roles of Cytology Screening and HPV Vaccination (자궁경부암 예방의 미래 : 세포선별검사와 HPV 예방접종의 역할)

  • McGoogan, Euphemia
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.1
    • /
    • pp.1-12
    • /
    • 2007
  • Approximately 70% of cervical cancers are caused by HPV types 16/18 and thus the implementation of vaccination programmes with vaccines against HPV types 16/18 will have a major impact on the incidence of cervical cancer worldwide. However, this reduction will not be seen until several decades after full implementation of such vaccination programmes since the vaccines must be given to young adolescents before exposure to the virus and women who are already sexually active are not likely to be protected. Both GSK and Merck insist that even vaccinated women must continue to participate in regular cervical screening by the most sensitive method available since the vaccine can only give protection against up to 70% of cervical cancers. It is unlikely that the current vaccines will be modified to include additional high risk HPV types in the foreseeable future. While HPV testing is highly sensitive, it is not recommended for women under 30 years of age nor for vaccinated women. Additionally, HPV testing has poor specificity. The Digene Hybrid Capture 2 test is licensed for use only in conjunction with a cytology test, not as a stand-alone test, and the high risk panel has recognised cross reactivity with low risk HPV types. None of the other HPV test methods currently commercially available are FDA approved and all must be internally validated before use. This makes comparison of test results between laboratories difficult. The most sensitive and specific screening test currently available for women of all ages is the Cytyc ThinPrep System consisting of the ThinPrep Pap Test (TPPT) and the ThinPrep Imaging System (Imager). The TPPT was the first LBC system approved by the US FDA in 1996 and there are about 4,000 processors in use worldwide. The Imager was FDA approved in 2003 and over 350 systems are in routine use, mainly in the US. 40% of TPPT in the US are processed on Imager. There is clear evidence in peer reviewed literature that the Imager increases laboratory productivity by 100% and growing evidence that Imager detects more high grade SIL than the conventional smear or manual evaluation of TPPT. This aspect is particularly important since the number of cytological abnormalities will decrease as vaccination programmes are implemented. Cytotechnologists will see fewer and fewer abnormal smears and their skills will be put at risk. By doubling throughput, Imager will allow cytotechnologists to maintain their skills.

Mechanical evaluation of the use of conventional and locking miniplate/screw systems used in sagittal split ramus osteotomy

  • Santos, Zarina Tatia Barbosa Vieira;Goulart, Douglas Rangel;Sigua-Rodriguez, Eder Alberto;Pozzer, Leandro;Olate, Sergio;Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.77-82
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical resistance of four different osteosyntheses modeled in two different sagittal split ramus osteotomy (SSRO) designs and to determine the linear loading in a universal testing machine. Materials and Methods: An in vitro experiment was conducted with 40 polyurethane hemimandibles. The samples were divided into two groups based on osteotomy design; Group I, right angles between osteotomies and Group II, no right angles between osteotomies. In each group, the hemimandibles were distributed into four subgroups according to the osteosynthesis method, using one 4-hole 2.0 mm conventional or locking plate, with or without one bicortical screw with a length of 12.0 mm (hybrid technique). Each subgroup contained five samples and was subjected to a linear loading test in a universal testing machine. Results: The peak load and peak displacement were compared for statistical significance using PASW Statistics 18.0 (IBM Co., USA). In general, there was no difference between the peak load and peak displacement related to osteotomy design. However, when the subgroups were compared, the osteotomy without right angles offered higher mechanical resistance when one conventional or locking 2.0 mm plate was used. One locking plate with one bicortical screw showed higher mechanical resistance ($162.72{\pm}42.55N$), and these results were statistically significantly compared to one conventional plate with monocortical screws (P=0.016) and one locking plate with monocortical screws (P=0.012). The difference in peak displacement was not statistically significant based on osteotomy design or internal fixation system configuration. Conclusion: The placement of one bicortical screw in the distal region promoted better stabilization of SSRO. The osteotomy design did not influence the mechanical behavior of SSRO when the hybrid technique was applied.

Testing for validity of isometric muscle endurance test as an abdominal muscular endurance evaluation methods (복근 지구력 평가 도구로서 등척성 수축 후 버티기 방법의 타당성 비교 검증)

  • Park, Soon-Tae;Hur, Sung-Hoon;Lee, Jang-Kyu;Lee, Jong-Sam
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.815-827
    • /
    • 2014
  • The current study was undertaken to verify appropriateness of muscle endurance test at three different angles ($30^{\circ}C$, $40^{\circ}C$, $50^{\circ}C$) of isometric contraction position, and to sought valid and reliable testing method that provide an alternative to sit-ups. Total 92 young and healthy subjects (68 males and 24 females) were recruited, and the following results were obtained. 1. A low correlations in males, but a high correlations in females was found when the comparisons were made between aerobic and muscle endurance capability. 2. Measuring tolerance time, by using isometric contraction was showed a significant correlation with the repetition numbers of sit-ups. 3. The highest correlation was found at 40 inclined degrees of plane, and the lowest correlation was drawn from 50 inclined degrees of plane. Based on these results, it was concluded that measuring tolerance time during maintaining an isometric contraction at 40 inclined degrees of plane is a valid and effective tool for measuring abdominal muscle endurance, and it can be used as an alternative way of sit-up, which potentially risky for inducing many back-associated injuries. Further studies need to be undertaken to determine for optimal angles, that can safely be applied for people of various age groups and physical conditions.

Development and evaluation of ANFIS-based conditional dam inflow prediction method using flow regime (ANFIS 기반의 유황별 조건부 댐 유입량 예측기법 개발 및 평가)

  • Moon, Geon-Ho;Kim, Seon-Ho;Bae, Deg-Hyo
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.607-616
    • /
    • 2018
  • Flow regime-based ANFIS Dam Inflow Prediction (FADIP) model is developed and compared with ANFIS Dam Inflow Prediction (ADIP) model in this study. The selected study area is the Chungju and Soyang multi-purpose dam watersheds in South Korea. The dam inflow, precipitation and monthly weather forecast information are used as input variables of the models. The training and validation periods of the models are 1987~2010 for Chungju and 1984~2010 for Soyang dam watershed. The testing periods for both watersheds are 2011~2016. The results of training and validation indicate that FADIP has better training ability than ADIP for predicting dam inflow in normal and low flow regimes. In the result of testing, ADIP shows low predictability of dam inflow in the low flow regime due to the model tuning on all flow regime together. However, FADIP demonstrates the improved accuracy over the entire period compared to ADIP, especially during the normal and low flow seasons. It is concluded that FADIP is valuable for the prediction of dam inflow in the case of drought years, and useful for water supply management of the multi-purpose dam.

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Evaluation of the Availability of the Wide Coverage Volume Axial Mode in Pediatric Cardiac CT (소아 심장 CT검사 시 Wide Coverage Volume Axial Mode의 유용성 평가)

  • Park, Ki Seok;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.683-689
    • /
    • 2019
  • We are trying to evaluate usefulness of Wide Coverage Volume Axial Mode by comparing and analyzing for exposure doses to patients and video quality extracted from two materials. First material is a computer tomography scanning of paediatric cardiac made by using High Pitch Mode, which is designed for diagnosing Congenital cardiac diseases. Second material is computer tomography scanning of paediatric cardiac made by using Wide Coverage Volume Axial Mode. When we did computer tomography scanning of paediatric cardiac, we used High Pitch Mode and Wide Coverage Volume Axial Mode to 50 patients of each, overall 100 patients. Also, we compared exposure doses to patients using videos got from each protocol. Then we compared video quality by calculating SNR and CNR by setting ROI of each. Not only exposure doses to patients were reduced by 13.07 %, but also SNR and CNR were improved when testing used Wide Coverage Volume Axial Mode rather than using High Pitch Mode. Wide Coverage Volume Axial Mode reduced testing time by using high-speed scanner. Furthermore, we can find out that Wide Coverage Volume Axial Mode is an useful method through improving video quality and reducing exposure doses to patients than using High Pitch Mode from ASiR-V, which is low-dose technology.

Evaluation of Conventional Culture Methods and Validation of Immunoassays for Rapid Detection of Listeria monocytogenes in Dairy and Processed Foods (유제품 및 가공식품에서 Listeria monocytogenes 검출을 위한 배지법과 신속 검사키트의 유효성 검증)

  • Han, So-Ri;Hyeon, Ji-Yeon;Kim, Hee-Yun;Park, Jong-Seok;Heo, Seok;Shin, Ho-Chul;Seo, Kun-Ho
    • Food Science of Animal Resources
    • /
    • v.28 no.5
    • /
    • pp.616-622
    • /
    • 2008
  • Listeria monocytogenes is a foodborne pathogen inducing listeriosis in human. We compared two different culture methods for detection of L. monocytogenes and validated two commercial kits, $VIDAS^{(R)}$ and $REVEAL^{(R)}$ for Listeria. L. monocytogenes was inoculated into various food samples to generate partial positive samples. The inoculated samples were enriched in half-Fraser broth for 48 hr at $30^{\circ}C$. The enriched samples were streaked onto Oxford agar at 24 and 48 hr postincubation followed by biochemical confirmation and concurrently analyzed by using the two commercial kits for comparison. When the enrichment period was extended from 24 to 48 hr, the numbers of positive samples were dramatically increased from 6 to 52 out of 80 samples tested using the culture method. With the commercial kits, the numbers of positive samples were also significantly increased from 10 to 18 and 1 to 18, respectively, when the enrichment period was extended from 48 to 72 hr. There was no statistical difference between the 24 hr culture method and $VIDAS^{(R)}$ or $Reveal^{(R)}$ with 48 hr enrichment. In conclusion, the 24 hr for the culture method was insufficient to detect L. monocytogenes in various foods. The commercial kits could be adequate means for presumptive screening of L. monocytogenes in food.

Quantitative Extraction Analysis of Brominated Flame Retardant Substances Using Supercritical-Fluid Method for Environmental Assessment (초임계추출법을 이용한 브롬계 난연제 화합물 환경성 평가 추출효율 분석 연구)

  • Oh, Min-Kyung;Yoon, Sang-Hwa;Lee, Young-Kwan;Han, Jae-Sung;Won, Sung-Ho;Nam, Jae-Do
    • Polymer(Korea)
    • /
    • v.32 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • For the evaluation of brominated flame retardants included in polymeric electronic devices, we investigated the extraction methods and solvent systems for four different types of polymers of PC (polycarbonate), PP (polyropylene), PET (poly(ethylene terephthalate)) and PBT (poly(butylene terephthalate)) using different solvent systems of hexane/acetone, THF, toluene, and THF/toluene. In order to compare the extraction efficiency of different methods and solvent systems, the deca-BDE (decabromo diphenyl ether) flame retardant was included in PC, PP, PET and PBT systems and subsequently extracted by soxhlet, ultrasonic, accelerated solvent, microwave and supercritical fluid extraction methods. The amount of the extracted flame retardant was monitored to evaluate the extraction efficiency. The ultrasonic extraction method was found not to be acceptable as an extraction method for the polymer systems mainly due to a low salvation efficiency of the organic solvents. Soxhlet, accelerated solvent and microwave extraction methods exhibited over 80% of extraction efficiency for toluene. The supercritical fluid extraction method, which has been used as an extraction method for flame retardants in polymers, showed the extraction efficiencies of ca. 100% for PC and PP in the optimal extraction conditions of $60^{\circ}C$ and 120 bar.