• Title/Summary/Keyword: Testing & Evaluation Method

Search Result 1,058, Processing Time 0.027 seconds

The Evaluation and Fabrication of Radiation Phosphor Screen for Non-destructive Testing using the Special Room Temperature Gel-printing Method (상온 겔프린팅 기법을 이용한 비파괴 검사용 방사선 증감지 제작 및 평가)

  • Lee, Jun Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.391-396
    • /
    • 2020
  • In this study, we developed a phosphor film screen that can be applied to radiographs during non-destructive testing using Gd2O2S:Tb phosphor compounds. The image uniformity of the fabricated phosphor screen film was analyzed by FE-SEM, RMS and RDS analysis. In addition, the tensile strength, elongation, and modulus of elasticity of the Gd2O2S:Tb phosphor screen were evaluated by measuring the stress-strain characteristic curve. As a result, it was evaluated that the RSD value had an excellent image uniformity within 10% of the evaluation criteria. In addition, as a result of evaluation of physical properties, the tensile strength was 1.1760 N/㎟, the tensile strength at break was 1.1515 N/㎟. These results suggest that the Gd2O2S:Tb phosphor screen fabricated using the room temperature gel-printing method could be applied to digital radiography detectors for radiography.

A Study on the Size Evaluation of Circular Flat Flaw with Indication by Straight Beam Inspection of Ultrasonic Wave (초음파(超音波)의 수직탐상법(垂直探傷法)에 의한 경사(傾斜)를 갖는 원형평면결함(圓形平面缺陷)의 크기 평가(評價)에 관한 연구(硏究))

  • Han, Eung-Kyo;Kim, Ki-Joong;Lee, Kook-Hwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.1
    • /
    • pp.11-22
    • /
    • 1984
  • In the straight beam inspection of ultrasonic wave, the method for evaluating flaw size by AVG diagram is useful as a method for the quantitative evaluation of results of ultrasonic flaw detection. This study was carried out the measure the size of circular flat flaw with the inclination by straight beam inspection and could be decreased the error of application due to the inclination of flaw by AVG diagram in consideration of correction coefficient. From the result of the experiment, the error by means of the application of experimental values to AVG diagram was increased as the inclination angle grows. Also, it n s increased the error of application as the detecting frequency and diameter of flaw grows in the same inclination angle. In case of diameter of flaw 6mm, AVG diagram could be applied to the inclination angle $3^{\circ}$ for 5 MHz, $7^{\circ}$ for 2.25 MHz, $15^{\circ}C$ for 1 MHz in the range of 20% error and the theory was concided with the experiment to $5^{\circ}C$ for 5 MHz, $10^{\circ}C$ for 2.25 MHz, $15^{\circ}C$ for 1 MHz in the range of 10% error by correction eq. (45) due to the inclination angle. Therefore, it is considered that the results obtained from this study will be somewhat helpful informations for the size evaluation of circular flat flaw with the inclination.

  • PDF

Development of a Multichannel Eddy Current Testing Instrument(II) (다중채널 와전류탐상검사 장치 개발(II))

  • Lee, Hee-Jong;Nam, Min-Woo;Cho, Chan-Hee;Yoo, Hyun-Joo;Kim, In-Chel
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.552-559
    • /
    • 2011
  • Recently, the eddy current testing(ECT), alternating current field testing, magnetic flux leakage testing and remote field testing have been used as a nondestructive evaluation method based on the electromagnetic induction phenomenon. The eddy current testing is now widely accepted as a NDE method for the heat exchanger tube in the electric power industry, chemical, shipbuilding, and military. The ECT system mainly consists of the synthesizer module, analog module, analog-to-digital converter, power supplier, and data acquisition and analysis program. In the previous study, the synthesizer module and the analog module which is essential to the ECT system were primarily developed, and in this study the data acquisition and analysis program were developed. The operation system for this program is based on the Windows 7, and optimized for the Korean users, and the specific feature of this program using setup wizard enables inspector to make a setup easily for acquisition and analysis of ECT data. In this paper, the configuration and functions of eddy current data acquisition and analysis program will be introduced.

Quantitative Evaluation Index Derivation of the Software Based on ISO/IEC 9126-2 Metrics (ISO/IEC 9126-2 메트릭을 활용한 소프트웨어 정량적 평가 지표 도출)

  • Cho, Sungho;Jang, Joongsoon
    • Journal of Applied Reliability
    • /
    • v.16 no.2
    • /
    • pp.134-146
    • /
    • 2016
  • Purpose: Many domestic companies have to make out quantitative evaluation table in their proposal when they conduct the software R&D project. However, most of companies have a difficulty to select the evaluation items and criteria, also to derive a quantitative results. Therefore, we propose a method to derive the quantitative evaluation index by utilizing the ISO/IEC 9126-2. Methods: Analyzing ISO/IEC 9126-2, and we classify the quality metrics as high-classification and sub-classification for Web/App software, Embedded software and Installation software. Next, Conduct the metrics selection survey depending on importance and necessity. Then, carry out the case study. Verify the correspondence between evaluation items and criteria from original suggestion of company and from outcome by utilizing the ISO/IEC 9126-2 quality metrics. Results: It is possible to classify into two metrics, one for common software or one another for only special software. Furthermore, there is quality metrics that is more important and more necessary depending upon characteristics of the software. Conclusion: ISO/IEC 9126-2 quality metrics can be used to make an evaluation items and criteria for quantitative evaluation table of software product.

Development of Automatic Evaluation Equipment for Burden of Instrument Transformer using Resistor Simulator (저항기를 이용한 계기용 변성기 부담 자동 평가 장치 개발)

  • Lee, Young Seob;Jung, Jae Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.589-595
    • /
    • 2014
  • The error of instrument transformers is measured by connecting the external burden with the secondary terminal of the instrument transformers. Because the error of transformer is affected by the apparent power and power factor of the external burden, an accurate measurement of burden is important for transformer evaluation. We have developed the burden evaluation equipment for both potential transformer and current transformer by employing the series resistor in the range of $20m{\Omega}{\sim}5{\Omega}$ and the parallel resistor in the range of $1M{\Omega}{\sim}500{\Omega}$, respectively, together with visual basic program. We could reduce testing time more than 5 times by employing method developed in this study, compared with that developed in past. This method shows more better reliability by analyzing the evaluation results and fitting graphs of burden measurements. The test results of the developed system is compared with those obtained in the power meter analyzer to verify the validity.

Study on The Anti-Shock Performance Evaluation of TFT-LCD module for Mobile IT Devices (이동형 정보통신 기기용 화면표시 장치의 내충격 평가 방법 연구)

  • Kim Byung-Sun;Kim Jung-Woo;Lee Dock-Jin;Choi Jae-Boong;Kim Young-Jin;Baik Seung-Hyun;Chu Young-Bee;Koo Ja-Choon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.130-137
    • /
    • 2006
  • TFT-LCD(Thin Film Transistor Liquid Crystal Display) module is representative commercial product of FPD(Flat Panel Display). Thickness of TFT-LCD module is very thin. It is adopted for major display unit for IT devices such as Cellular Phone, Camcorder, Digital camera and etc. Due to the harsh user environment of mobile IT devices, it requires complicated structure and tight assembly. And user requirements for the mechanical functionalities of TFT-LCD module become more strict. However, TFT-LCD module is normally weak to high level transient mechanical shock. Since it uses thin crystallized panel. Therefore, anti-shock performance is classified as one of the most important design specifications. Traditionally, the product reliability against mechanical shock is confirmed by empirical method in the design-prototype-drop/impact test-redesign paradigm. The method is time-consuming and expensive process. It lacks scientific insight and quantitative evaluation. In this article, a systematic design evaluation of TFT-LCD module for mobile IT devices is presented with combinations of FEA and testing to support the optimal shock proof display design procedure.

The Influence and Treatment Method of Extraneous Deformation & Unstability on the Flexural Toughness of FRC (FRC의 휨인성 평가시 외부변형과 불안정성의 영향 및 처리방안)

  • Kim, Kyoung-Soo;Kim, Nam-Wook;Lim, Jeong-Hwan;Bae, Ju-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.119-128
    • /
    • 2002
  • This study discusses the issues related to the accuracy of deflection measurement and unstable energy in the testing of FRC. Some deflection methods may include large extraneous deformations. A faulty load-deflection curve will be obtained if an unstable deflection measuring system is used, and inaccurate toughness evaluation can result from this faulty curve. Some load-deflection curve of FRC may be attributed to unstable region of the load-deflection curve. If the unstable region is not correctly evaluated toughness indices from the curve would inappropriately represent true indices. In this paper, the discussion will focus on the effects of the deflection measuring system both on the measurement of the load-deflection response of FRC and the evaluation of FRC toughness and the effects of the unstable region and the management method of unstable region on toughness evaluation of FRC. It is observed that ASTM toughness indices which is based on measured deflection at first cracking is influenced significantly by extraneous deformation of deflection measurement. Extraneous deformation in deflection measurement, however result in negligible errors in toughness evaluation if JSCE and JCI definitions are used.

Feasibility study on the Evaluation of the degree of consolidation using shear waves for soft clay deposits (전단파를 이용한 연약지반의 압밀도 평가기법 적용성 연구)

  • Youn, Jun-Ung;Kim, Jong-Tae;Lee, Jin-Sun;Kim, Dong-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.442-451
    • /
    • 2008
  • The evaluation of field degree of consolidation on soft clays has been an important problem in geotechnical areas. Monitoring either settlements or pore water pressures has been widely applied in the filed, but occasionally they have some problems. This study addresses the suggestion and application of another method for evaluating the degree of consolidation using shear wave velocities. A research site where soft clay layers were consolidated by surcharging loads was chosen. Laboratory tests were performed to determine the relation between shear wave velocity and effective stress. Field seismic tests were conducted several times during the consolidation of the clay layers. The tests results show that the shear wave velocity increased significantly as clays consolidated. The shear wave velocities at each field stress states were derived from the laboratory results and the degree of consolidation was evaluated by comparing the shear wave velocities obtained by laboratory and field seismic methods. In most stress states, the degree of consolidation evaluated using the shear wave velocity matched well with that obtained from field settlement record, showing the potential of applying the method using shear waves in the evaluation of field degree of consolidation on soft clay deposits.

  • PDF

An Experimental Study on Thrust measurement Method of Supersonic Wind Tunnel from Pressure Measurement (압력 측정을 이용한 초음속 풍동의 추력 측정 방법에 대한 실험적 연구)

  • huh Hwanil;Kim Hyungmin
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.253-254
    • /
    • 2002
  • The determination of thrust is very important in hypersonic air-breathing propulsion design and evaluation. Because of the short flow-residence time in the combustor, the evaluation of engine performance is strongly influenced upon the engine thrust. Conventional methods to determine the thrust is using thrust stand or force measurement system. However, these methods cannot be applied to the case where thrust stands are impractical, such as free jet testing of engines, and model combustor. With this reason, the thrust determination method from measured pilot pressure is considered and evaluated.

  • PDF

A Study on Performance Evaluation Plan of Next-Generation High-Speed Prototype Train during Test Run (차세대고속열차 본선 시운전 성능평가 방안에 대한 연구)

  • Kim, Sang-Soo;Choi, Snng-Hoon;Park, Choon-Soo;Kim, Seok-Won;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1814-1820
    • /
    • 2010
  • Korean Train Express (KTX) has been commercially operating and achieving elevation on transport capacity since 2004. And the first hish-speed prototype test train, HSR-350x, was developed and succeeded in testing of running over 350km/h. Now KTX-II based on HSR-350x was started in service run. The new high-speed train development project, HEMU-400x project, has started since 2007. The protype train is being designed and manufactured. After the train are developed completely, it will run on the commercial line and will be test to verify the estimated performance. The authors devised the performance evaluation method and process of the HEMU-400x prototype system. And we introduce the definite performance test items and the method to vitrificate them in this paper.

  • PDF