• Title/Summary/Keyword: Test-retest Method

Search Result 88, Processing Time 0.023 seconds

Study of Construct Validity and Test-Retest Reliability of the Korean Version Peabody Developmental Motor Scales-Second Edition (PDMS-2) (한글판 Peabody Developmental Motor Scales-second edition (PDMS-2)의 구성타당도와 검사-재검사 신뢰도)

  • Kim, Bo-Ram;Kim, Kyeong-Mi;Chang, Moon-Young;Hong, Eunkyoung
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.19 no.3
    • /
    • pp.32-43
    • /
    • 2021
  • Objective : This study aimed to verify the construct validity of the Korean version of the Peabody Developmental Motor Scale-2 (K-PDMS-2) and its test-retest reliability for children with cerebral palsy (CP) and typical children. Method : To ascertain the construct validity, the K-PDMS-2 evaluation was conducted on 42 children with cerebral palsy and 42 typical children of similar age and gender. Construct validity was proved through comparison with standard scores. Ten of the children with CP were re-evaluated after two weeks to determine test-retest reliability. Results : There was a statistically significant difference in gross motor and fine motor development according to five subtests between the group of children with CP and the typical group (p = .000). For test-retest reliability, the correlation coefficient of the total frequency score was .989, representing very high temporal stability. Conclusion : This study confirmed that K-PDMS-2 is an evaluation tool of high reliability and validity, and a potentially useful future measure for domestic clinical sites and research.

Validity and Reliability of the Knee Joint Proprioceptive Sensory Measurements using a Smartphone (스마트폰을 이용한 무릎관절 고유수용성 감각 측정의 타당도와 신뢰도 검증)

  • Kim, Myung-Chul;Kim, Nam-Jae;Lee, Min-Soo;Moon, So-Ra
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.15-23
    • /
    • 2015
  • PURPOSE: We aims to promote the development of proprioception measurement using smartphones, goniometers, and laser pointers as compared to the conventional use of electrogoniometer measurement. METHODS: Measurements using an electrogoniometer were previously proved to be reliabile and valid. Among E-university students, 20 who had no fracture, operation history, or inflammatory arthritis were examined. These subjects had not performed regular exercise in the past 3 months. Proprioception measurements were performed using four different measurement tools, three times per day, for test-retest analysis. RESULTS: No notable test-retest differences were noted for any of the measurement methods (P>0.05). With regard to the test-retest reliability for each measurement method, we observed that the readings from both the electrogoniometer and smartphone have high reliability (ICC>0.80), whereas the readings from the laser pointer have moderate reliability (ICC>0.60). When assessing the concurrent validity between electrogoniometers with individual measurements, we did not observe any notable difference between the smartphone and electrogoniometer (P>0.05) and these tools in fact showed high correlation (r>0.60, P<0.05) and a moderate reliability (ICC>0.60). Moreover, there was no notable difference in between electrogoniometers and laser pointers (P<0.05). CONCLUSION: CONCLUSION: The findings of this suggested that proprioception can be measured by using smart-phones, and proved that this method has sufficient credibility. Moreover, we noted that the concurrent validity with smartphones was high in comparison with the conventional electrogoniometer, which also indicates the validity and credibility. Based on these findings, we conclude that the measurement of proprioception by using a smartphone can be widely adopted.

The effect of Mental Practice on the upper extremity function of the Hemiplegic Patients (정신훈련이 뇌졸중환자의 상지 기능회복에 미치는 영향)

  • Park, Chang-Sik;An, Seung-Hun
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.3
    • /
    • pp.59-69
    • /
    • 2005
  • The purpose of this study was to investigate the effect of mental practice on the upper extremity function of the hemiplegic Patients, 8 subjects with hemiplegia patients participated in this study. They did the Mental Practice programme for twenty minute, two times a week, three weeks. The Mental practice effects was evaluated by Fugl-Meyer Assessment(FMA), Action Research Arm Test(ARA), Stroke Rehabilitation Assessment of Movement(STREAM). The data were analyzed using paired t-test. The result of this study are as follows: FMA score were significant difference test-retest(p<.05), ARA score were statistically significant improvement between test-retest(p<.05), On the STREAM, the patients had the score improved on 4 of the 10 items of the upper-extremity Scale. The result suggest that mental practice is a potentially useful method of practicing motor skills. Mental practice may be a cost-effective, non-invasive tool with wuhich patients with stroke can receive additional practice of functional skills, and realize greater outcome, than if therapy alone were used.

  • PDF

On the Test of the reliability and validity of the Disabled's Motivation Scale for Rehabilitation (장애인의 재활동기 측정도구의 신뢰도 및 타당도 검정 연구)

  • Han, Hye-Sook;Lim, Nan-Young
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.5 no.2
    • /
    • pp.124-133
    • /
    • 2002
  • Purpose: to test of the reliability and validity of the Disabled's Motivation for Rehabilitation Scale, which was developed in 2002. Method: An experimental version of the scale was distributed to a sample of 441 disabled with ages above 18 and below 80 years. The subjects of the test-retest were 60 disabled. Results: revealed a satisfactory level of test-retest and internal consistency. The overall fit of the factor model to the data was good. Correlation among the subscales revealed a simple pattern that, in general, provides support for the self-determination continuum and the construct validity. In testing concurrent, criterion-validity, there was a positive correlation between the motivation scores for rehabilitation and the Health-Related Hardiness scores and a negative correlation between the motivation scores for rehabilitation and the Learned Helplessness scores. Conclusion: The Disabled's Motivation for Rehabilitation Scale revealed a useful instrument with a high degree of reliability and validity. In this sense, this instrument can be effectively utilized in rehabilitative nursing for the disabled.

  • PDF

Reliability and validity of free software for the analysis of locomotor activity in mice

  • Hong, Yoo Rha;Moon, Eunsoo
    • Journal of Yeungnam Medical Science
    • /
    • v.35 no.1
    • /
    • pp.63-69
    • /
    • 2018
  • Background: Kinovea software that tracking semi-automatically the motion in video screen has been used to study motion-related tasks in several studies. However, the validation of this software in open field test to assess locomotor activity have not been studied yet. Therefore, this study aimed to examine the reliability and validity of this software in analyzing locomotor activities. Methods: Thirty male Institute Cancer Research mice were subjected in this study. The results examined by this software and the classical method were compared. Test-retest reliability and inter-rater reliability were analyzed with Pearson's correlation coefficient and intraclass correlation coefficient (ICC). The validity of this software was analyzed with Pearson's correlation coefficient. Results: This software showed good test-retest reliability (ICC=0.997, 95% confidence interval [CI]=0.975-0.994, p<0.001). This software also showed good inter-rater reliability (ICC=0.987, 95% CI=0.973-0.994, p<0.001). Furthermore, in three analyses for the validity of this software, there were significant correlations between two methods (Pearson's correlation coefficient=0.928-0.972, p<0.001). In addition, this software showed good reliability and validity in the analysis locomotor activity according to time interval. Conclusion: This study showed that this software in analyzing drug-induced locomotor activity has good reliability and validity. This software can be effectively used in animal study using the analysis of locomotor activity.

Development of a Scale to Measure Korean Smoking Temptation (한국형 흡연유혹 측정도구 개발을 위한 연구)

  • 장성옥
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.5
    • /
    • pp.849-858
    • /
    • 2004
  • Purpose: Smoking temptation is the central concept related to relapse within the context of smoking. Therefore :or effective smoking cessation interventions, a scale to measure smoking temptation is necessary. This study was carried out to develop scale to measure smoking temptation. Method: This study utilized Cronbach's alpha, spilt-half coefficient and test-retest correlation in analyzing the reliability of the collected data and expert group, factor analysis, item analysis multitrait-multimethod method and known-group technique to analyze validity. Result: Twenty-five items were selected from a total of 33 items. The Cronbach's alpha coefficient for internal consistency was .93, spilt-half coefficient .91, and 2 week interval test-retest correlation .93 for the 25 items on the smoking temptation scale. Five factors evolved by factor analysis, which explained 57.28 % of the total variance. The smoking temptation scale was effective in differentiating the subjects at each stage of change for smoking cessation and there were significant negative correlations between smoking temptation and self efficacy for smoking cessation and significant positive correlations between smoking temptation and the Fagerstrom Tolerance Questionnaire. Conclusion: The scale for measuring smoking temptation in Korean in this study was evaluated as a tool with a high degree of reliability and validity.

Reliability of the Modified - Modified $Sch{\ddot{o}}ber$ Methods for Measuring Lumbar Flexion and Extension ROM (요부굴곡과 신전관절범위측정을 위한 MMS방법 신뢰도)

  • Kim, Tae-Suk;Cho, Jung-Sun;Park, Young-Han
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.4
    • /
    • pp.763-770
    • /
    • 1995
  • The primary purpose of this study was to determine the reliability of lumbar flexion and extension range-of -motion measurements obtained with the modified -modified $Sch{\ddot{o}}ber$ methods on normal and subjects with low back pain. Sixty two, aged 20 to 30 years(x = 22.0, SD = 2.07), with normal and twenty two, aged 14 to 66 years(x = 35.6, SD = 15.88) with chronic low back pain were measured by two physical therapist with 3 to 10 years (x = 6.5) of clinical experience. The therapist used the modified-modified $Sch{\ddot{o}}ber$(MMS) techniques to measure, in random order and on two occasions, the subjects' lumbar flexion and extension. For therapist 1, Intraclass correlation coefficients(ICC) for test-retest reliability for normal varied .9923, .8802(flexion, extension). and low back pain pateint varied .9950, .9313(flexion, extension). For therapist 2. ICC. for test-retest reliability for normal varied .9903, .8921(flexion, extension). and low back pain pateint varied .9843, .9551(flexion, extension). Interrater reliability for normal varied .9477, .6960(flexion, extension) and low back pain pateint varied. 9776, .7576(flexion, extension). Thus the MMS. method appears to be a reliable method for normal and patient with low back pain.

  • PDF

Reliability and Validity of the Diet Quality Index for 7-9-year-old Indian Children

  • Chamoli, Ritushri;Jain, Monika;Tyagi, Gargi
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.22 no.6
    • /
    • pp.554-564
    • /
    • 2019
  • Purpose: This study verified the reliability and validity of the Diet Quality Index for Indian children (DQIIC). Methods: The study sample included 100 school going boys and girls (7-9 years). The dietary behavior of children was studied using a questionnaire and 24-hour dietary recall. The DQIIC comprises 21 items which aimed to assess the diet of Indian children on the basis of variety, adequacy of consumption of dietary components, and moderation in the amount of nutrients that are associated with diseases and dietary habits. The reliability of the DQIIC was assessed using the split half method, Cronbach's alpha, and test retest reliability. Content validity was evaluated using content validity ratio (CVR). Results: The intake of iron was found to be less than the recommended dietary allowances. There was frequent consumption of empty calorie packaged foods and higher than the recommended amount of sodium. Reliability of the DQIIC was 0.85 by split half method and the correlation coefficient for test retest reliability was 0.87. Cronbach's alpha was 0.62 and CVR was 0.85 for this index. Most of the children fell in the moderately healthy category. Conclusion: The DQIIC is a reliable and valid tool to assess the diet quality of Indian children between 7-9 years.

Reliability and Validity of the Korean Version of the Coping and Adaptation Processing Scale-Short-Form in Cancer Patients

  • Song, Chi Eun;Kim, Hye Young;So, Hyang Sook;Kim, Hyun Kyung
    • Journal of Korean Academy of Nursing
    • /
    • v.48 no.3
    • /
    • pp.375-388
    • /
    • 2018
  • Purpose: This study was conducted to assess the reliability and validity of the Korean version of the Coping and Adaptation Processing Scale-Short- Form in patients with cancer. Methods: The original scale was translated into Korean using Brislin's translation model. The Korean Short-Form and the Functional Assessment Cancer Therapy-General were administered to 164 Korean patients with cancer using convenience sampling method. The collected data were analyzed using SPSS 23.0 and AMOS 23.0. Construct validity, criterion validity, test-retest reliability, and internal consistency reliability of the Korean Coping and Adaptation Processing Scale-Short-Form were evaluated. Results: Exploratory factor analysis supported the construct validity with a four-factor solution that explained 60.6% of the total variance. Factor loadings of the 15 items on the four subscales ranged .52~.86. The four-subscale model was validated by confirmatory factor analysis (Normed ${\chi}^2=1.38$ (p=.013), GFI=.92, SRMR=.02, RMSEA=.05, TLI=.94, and CFI=.95), and criterion validity was demonstrated with the Functional Assessment Cancer Therapy-General. Cronbach's alpha for internal consistency of the total scale was .83 and ranged .68~.81 for all subscales, demonstrating sufficient test-retest reliability. Conclusion: The Korean version showed satisfactory construct and criterion validity, as well as internal consistency and test-retest reliability.

Development and Validation of Questionnaire for Chronic Fatigue Syndrome (CFS) Diagnosis Based on Systemic Exertion Intolerance Disease (SEID) Criteria (전신성 활동불능증(Systemic Exertion Intolerance Disease) 진단 기준을 바탕으로 한 만성 피로 증후군(Chronic Fatigue Syndrome) 진단 설문지 개발 및 신뢰도 평가)

  • Lim, Eun-jin;Son, Chang-gue;Jang, Eun-su
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.293-305
    • /
    • 2020
  • Purpose: This study aimed to develop a questionnaire for the diagnosis of chronic fatigue syndrome (CFS) designed based on the systematic exertion intolerance disorder (SEID) criteria, and to validate the reliability of the questionnaire. Methods: A literature search on questionnaires for CFS diagnosis was conducted to develop a SEID questionnaire (SEID-Q27), followed by a pilot survey to identify the reliability of the questionnaire. Adults (Daejeon university personnel) with a Chalder fatigue scale (CFQ) score ≥15 were invited for the survey. We commenced the survey in November 2019 with a two weeks of interval for the test and retest method. The reliability of the questionnaire was investigated in three angles: 1. Cronbach's α, 2. correlations (r) of the questions, numerical rating scale (NRS), and visual analog scale (VAS), and 3. kappa (k) analysis. Results: Among the total 275 adults registered, 55 (20%) participants with a CFQ score ≥15 were invited, and 31 (11%) [15 male, 16 female] completed the questionnaire. The total Cronbach's α was 0.944 for the test and 0.949 for the retest. The reliability (r) of questions by CFQ score (≥15, ≥18, ≥20) ranged from 0.533-0.928 (p <0.05), and the r score of the NRS and VAS were the highest in CFQ scores ≥20, at 0.933 (p<0.001). The agreement rate of the SEID-Q27 between the test and retest was 87% (kappa k=0.743). Conclusions: The SEID-Q27 seems to be reliable. Further studies are needed to measure the validity of the tool and the cutoff point.