• 제목/요약/키워드: Test-cross

검색결과 4,250건 처리시간 0.034초

Evaluation of Bonding Strength of Larch Cross-Laminated Timber

  • Song, Yo-Jin;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권4호
    • /
    • pp.607-615
    • /
    • 2016
  • The delamination along the annual ring on the cross-section of laminae and the bonding strength according to the tangential angle between laminae were evaluated for the production of 3-ply cross-laminated timber (CLT) using domestic larch. Since there is no standard for CLT in Korea, the production and test of specimens for bonding strength followed the standard procedure of "Structural glued laminated timber" (KS F 3021). The standard specifies to exclude any measurement from the cracks of timbers resulted from drying or knots during delamination test of the glued laminated timbers. However, the failure of cross-sectional tissues along the annual rings was observed near the glue-line of all specimens during the delamination test. Because this phenomenon can generate defects in the CLT that may be exposed to various temperatures and relative humidities after the actual construction, the delamination percentage was measured by including this wood failure. As a result, the delamination percentage of the CLT which had been combined in such a way that the annual rings of outer lamina were directed inward was the lowest, which was around 13%, regardless of the annual ring direction of the middle lamina. On the other hand, the delamination percentage of the CLT which had been combined in such a way that the annual rings of outer lamina were directed outward was the highest, which was around 26%. Furthermore, end-split occurred in the outer lamina during the drying process of the boiling delamination test, which affected the delamination percentage. Therefore, the soaking delamination test was found to be more appropriate for evaluating the delamination strength of CLT. The block shear strength of larch CLT was $3.9{\pm}0.9$ MPa on average, which was 46% lower than the block shear strength requirement (7.1 MPa) of the standard, but satisfied the criteria of the block shear strength (3.5 MPa) of the European Standard (prEN 16351: 2013).

Distribution-Free Tests for Cross-Over Design Data

  • Kim, Dong-Jae
    • Communications for Statistical Applications and Methods
    • /
    • 제6권1호
    • /
    • pp.151-158
    • /
    • 1999
  • Distribution-free tests are proposed for AB/BA 2*2 cross-over design data based on placements introduced by Orban and Wolfe(1992). In this paper we suggest the homogeneity test or carry-over effects and also suggest the test for direct effects and the test for period effects under the same carry-over effects. The properties such as iterative asymptotic distribution for the proposed tests are discussed.

  • PDF

사력댐 동적물성 추정을 위한 현장조사기법 적용 및 분석 (Application and Analysis of Field Test and Geophysical Exploration for Dynamic Material Properties of Rockfill Dam)

  • 이종욱;김기영;전제성;조성은
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.352-359
    • /
    • 2005
  • In this study, seismic refraction survey and MASW at dam crest and down-hole test and cross hole test in the boring holes located in dam crest through the core are performed to fin out dynamic material properties, are needed to evaluate dynamic safety of rockfill dam using dynamic analysis method. From the field test and geophysical exploration, applied such as above, p-wave and s-wave velocity profile of each layer of dam body. Dynamic material properties, such as elastic modulus, shear modulus, poissong's ration, are obtained from p-wave and s-wave velocity profile and density profile from formation density logging test.

  • PDF

THE VALIDITY OF HEALTH ASSESSMENTS: RESOLVING SOME RECENT DIFFERENCES

  • Hyland Michael E.
    • 대한예방의학회:학술대회논문집
    • /
    • 대한예방의학회 1994년도 교수 연수회(역학)
    • /
    • pp.137-141
    • /
    • 1994
  • The purpose of this paper is to examine what is meant by a ralid measure of health. Guyatt, Kirshner and Jaeschke propose that health tests should be designed so as to have one of several kinds of validity: 'longitudinal construct validity' for those which are used for longitudinal research designs, and 'cross-sectional construct validity' for those which are used for cross-sectional designs. Williams and Naylor argue that this approach to test classification and validation confuses what a test purports to measure with the purpose for which it is used, and that some tests have multiple uses. A review of the meanings of validity in the psychologica test literature shows that both sets of authors use the term validity in an idiosyncratic way. Although the use of a test (evaluated by content validity) should not be conflated with whether the test actually measures a specified construct (evaluated by construct validity);' if health is actually made up of several constructs (as suggested in Hyland's interactional model) then there may be an association between types of construct and types of purpose. Evidence is reviewed that people make several, independent judgements about their health: cognitive perceptions of health problems are likely to be more sensitive to change in a longitudinal research design. whereas emotional evaluations of health provide less bias in cross-sectional designs. Thus. a classification of health measures in terms of the purpose of the test may parallel a classification in terms of what tests purport to measure.

  • PDF

약물검사 키트의 분석 민감도에 대한 연구 (A Study of Analytical Sensitivity on TDM Test Kit in Clinical Chemistry)

  • 장상우;김남용;이희경;김현정;이윤정;진옥배;김미경
    • 대한임상검사과학회지
    • /
    • 제36권2호
    • /
    • pp.127-130
    • /
    • 2004
  • Analytical sensitivity on TDM test is the lowest concentration that can be distinguished from background noise. The aim of study was to evaluate analytical sensitivity that is also referred to as the lower limit of detection(LLD) about difference between zero calibrator and isotonic saline sample. We tested for 10 days with zero calibrators and 0.85% saline samples while running trilevel control samples under control. Raw data divided by two groups calculated mean and standard deviation from two sample populations and analytical sensitivity by ${\bar{X}}+2SD$. In comparison with isotonic saline samples and zero calibrators, there were significant differences in phenytoin, phenobarbital and vancomycin, etc. Especially analytical sensitivity on phenytoin is at the same level as the upper limit of analytical measurement range with $40{\mu}g/mL$. We think the cause of this is matrix interference. In conclusion, we were sure that standard protocol for analytical sensitivity as lower limit of analytical measurement range on TDM test must be measured with zero standard rather than an isotonic saline sample and type 1 reagent DW for reducing matrix effects within interactions between different materials in a mixture.

  • PDF

강재의 단면형상에 따른 내화피복두께 산정 연구 (Study on the Determination of Fire Protection Thickness based on Section Factor)

  • 정청운;지남용;권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.139-142
    • /
    • 2003
  • Traditionally, the thickness of fire protection materials of structural elements such as beam and column have been decided by fire test using the predominant steel section of $H-300{\times}300{\times}10{\times}15$ for column and $H-400{\times}200{\times}8{\times}13$ for beam in Korea. But this way of determination of fire protection thickness yields very unduly results. Because the temperature-increment rate of structural steel elements depends mainly on magnitude of their cross-areas. In general, the thicker size of cross-areas for structural elements, the lower temperature shows up. It had already proved that the fire protection thickness only depends on the size of cross-areas and the fire protection method for three-fide or four-side exposed conditions in European countries, the United State of America and so on. To demonstrate there would be differences among various cross-areas for structural elements, we conducted several fire tests with full-scale specimens of beams and columns. For the determination of critical temperature for steel section when the fire resistant performance is needed to be decided, we conducted with a loaded fire test for beam and column, respectively. The small column in 1.0 meter length and beam in 1.5 meter length were used in order to deprive the rational fire protection thickness of structural elements such as beam and column, respectively. After test, we could obtain there were significant temperature lass between higher cross-areas and lower cross-areas. The critical temperature of steel as a criterion is used 538$^{\circ}C$ for column and 593$^{\circ}C$ for beam which is from ASTM E 119 because we don't make provisions as critical temperature by elements. We could consider that the best way of determination of fire protection thickness is using the following multi-regression equation which was deprived from several fire tests using the concept of section factor, FR(column) = 0.17 +5191.49t A/Hp + 40.77t, FR(beam) = 0.25 +6899.31t A/Hp + 32.60t(where, FR means fire resistant time, t means thickness, A means cross-area and Hp means heated parameter).

  • PDF

고속 블록 정합 움직임 측정을 위한 십자-다이아몬드-삼각 탐색 알고리즘 (A Cross-Diamond-Triangle Search Algorithm for Fast Block-Matching Motion Estimation)

  • 김성훈;신재민;오승준;안창범;박호종;심동규
    • 방송공학회논문지
    • /
    • 제10권3호
    • /
    • pp.357-371
    • /
    • 2005
  • 본 논문에서는 CDS(Cross-Diamond Search algorithm) 및 CDHSs(Cross-Diamond-Hexagonal Search algorithms)의 성능을 향상시키기 위하여 탐색 영역의 위치에 따라 최적의 탐색 형태를 적용하는 CDTS(Cross-Diamond-Triangle Search algorithm)를 제안한다. CDTS에서 탐색 영역의 위치에 따라 최적의 탐색 형태를 적용하기 위하여 다양한 실험 영상들의 움직임 분포를 먼저 분석하였다. 분석된 움직임 분포에 근거하여 CDTS 구현 시 탐색 영역 중심부에서는 십자 탐색 형태와 다이아몬드 탐색 형태를 적용하고, 나머지 탐색 영역에서는 삼각 탐색 형태와 다이아몬드 탐색 형태를 적용한다. CDTS에서 제안하는 삼각 탐색 형태는 기존 탐색 알고리즘에서 사용하는 대칭형 구조와는 다르게 비대칭형 구조를 가지고 탐색점을 더욱 감소시키는 효과를 제공하면서도 화질을 유지할 수 있다. CDTS를 CDS 및 CDHSs와 비교하였을 때 화질 열화 없이 각각 평균 16.22$\%$ 및 3.09$\%$ 정도의 탐색점 감소 효과가 나타났다.

SI기법을 이용한 변단면 PSC 거더의 층상화 단면해석 (Layered Section Analysis for PSC Girder with Variable Cross Section Using SI Technique)

  • 김병화;박대효;전혜관
    • 대한토목학회논문집
    • /
    • 제30권6A호
    • /
    • pp.581-590
    • /
    • 2010
  • 본 연구는 곡선배치 텐던을 갖는 변단면 PSC의 전단을 고려한 층상화 단면해석기술을 소개한다. 곡선배치 텐던의 전단평형을 고려하기 위해서, 각 층상화 단면에서 전단응력을 직접 산출 할 수 있는 새로운 방법과 각 층상화 단면의 변형률 산정시 기존의 반복법보다 수렴 속도가 효율적인 시스템인식기법을 적용하였다. 제안기법은 변단면 PSC보의 정재하실험 결과와 비교분석 되었으며, 추정된 구조응답과 실험결과가 잘 일치하고 있다. 또한, 동일 조건에서 변단면 PSC보와 균등단면 PSC보의 거동특성이 비교분석되었다. 분석결과을 살펴보면, 휨강성은 변단면과 균등단면이 동일하지만, 전단강성은 변단면이 균등단면 보다 크다. 더욱이, 변단면의 자중이 균등단면보다 크지만 변단면의 최대처짐이 균등단면 보다 작다.

검정교배 기법을 이용한 두 계통 잉어 종묘의 동시생산 (A Production Method for Two Strains of Common Carp (Cyprinus carpio) Using Test-cross at a Breeding Trial)

  • 김동수;서재은;오승용;조재윤
    • 한국양식학회지
    • /
    • 제12권2호
    • /
    • pp.163-165
    • /
    • 1999
  • A production method for scaled and scaleless strain of common carp (Cyprinus carpio) at a breeding trial is developed by test-cross technique. When the fish with scaleless (Israeli strain of common carp) were crossed with scaled strain (hybrid fish between oriental and Israeli strain of the species), we can easily obtain 2 types of common carp with or without scale. The frequency of scaleless fish in this experiment was about 40% in the population, however, their growth rate was slightly higher than scaled fish after 3 months of this experiment.

  • PDF

R407C 및 R410B 적용 창문형 에어컨의 성능에 관한 실험적 연구 (An experimental study on the performance of a window system air-conditioner using R407C and R410B)

  • 김만회;신정섭;김권진
    • 설비공학논문집
    • /
    • 제9권4호
    • /
    • pp.536-544
    • /
    • 1997
  • This study presents test results of a residential window system air-conditioner using R22 and two potential alternative refrigerants, R407C and R410B. A series of performance tests was performed for the basic and liquid-suction heat exchange cycle in a psychrometric calorimeter test facility. For R407C, the same rotary compressor was used as in the R22 system. However, compressor for the R410B system was modified to provide the similar cooling capacity. The evaporator circuit was changed to get a counter-cross flow heat exchanger to take advantage of zeotropic mixture's temperature glide, and liquid-line suction-line heat exchange cycle was also considered to improve the performance of the system. Test results were compared to those for the basic R22 system.

  • PDF