• Title/Summary/Keyword: Test-bed data

Search Result 438, Processing Time 0.031 seconds

The Effects of Medical Staffing Level on Length of Stay (의료 인력의 확보가 환자 입원일수에 미치는 영향)

  • Lee, Han-Ju;Ko, Yu-Kyung;Kim, Mi-Won
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.17 no.3
    • /
    • pp.327-335
    • /
    • 2011
  • Purpose: The objective of this study was to analyze the effects of medical staffing level as bed-to-medical staff ratio on patient outcomes as length of stay (LOS) among hospitals in Korea. Methods: Two hundred and fifty one hospitals participated in the study between January and March 2008. Data for the study was requested by an electronic data interchange from the Health Insurance Review Agency in 2008. In data analysis, SPSS WIN 15.0 program was utilized for descriptive statistics, t-test, ANOVA, Pearson correlation coefficients, and multiple regression. Results: The mean score for length of stay was 13.6 days. The mean of operating bed-to-nurse ratio was 7.93:1. The predicting factors for LOS were bed-to-nurse's aide ratio, bed-to doctor's ratio, severely ill patient rate, and hospital type. These factors explained 28.9% of the variance in patient outcomes. Conclusion: This study results indicate that the relationship between medical staffing level and patient outcomes is important in the improvement of the quality of patient care. Thus, improvements in the quality of the nurse practice environment could improve patient outcomes for hospitalized patients.

The Impact on the accuracy of the basic CPR according to position and foot-board height of the basic CPR provider (심폐소생술 제공자의 발판 높이와 자세가 기본심폐소생술의 정확도에 미치는 영향)

  • Choi, Eun-Sook;Cho, Keun-Ja
    • The Korean Journal of Emergency Medical Services
    • /
    • v.12 no.3
    • /
    • pp.27-41
    • /
    • 2008
  • Purpose : The purpose of this study was to supply basic data for the impact on the accuracy of basic CPR according to position and foot-board height of basic CPR provider. Methods : Study design was within - group design. Subjects were 25 EMT-P Students in K city. Interventions was basic CPR performed on a resuscitation manikin placed on a hospital bed, kneeling on the bed adjacent to the manikin. Data was analyzed using descriptive statistics and Friedman test. Results : In case of the basic CPR performed on a resuscitation manikin placed on a hospital bed, ventilation accuracy was the highest in less than 160 cm height, foot-board height : $34.2{\pm}1.48cm$, 91.4% and in 161-165 cm height, foot-board height : $26.0{\pm}2.14cm$, 88.4% and in 171-175 cm height, foot-board height : $23.0{\pm}1.41cm$, 91.3% and in the above 176 cm, kneeling on the bed, 95%. Chest compression accuracy was the highest in less than 160 cm height, foot-board height : $30.2{\pm}1.48cm$, 95.6% and in 161-165 cm height, kneeling on the bed, 97.6% and in 171-175 cm height, kneeling on the bed, 98.5% and in the above 176 cm, kneeling on the bed, 98.7% and foot-board height : $20.5{\pm}1.91cm$, 98.7%. Chest compression error was due to too weak : 2.0-35.4 times. There were ststistically significant differences in 191-195 cm group according to chest compression mean depths($x^2=10.824$, p = .013) and chest compression error (p = .040). Conclusion : In contrast to current guidelines, the position and foot-board height of basic CPR provider are very important to the accuracy of the basic CPR. Furthermore, we recommend that a using real time audiovisual feedaback system significantly improve the quality of chest compression and ventilation during resuscitation.

  • PDF

A Study on the Optimization of Power Consumption Pattern using Building Smart Microgrid Test-Bed (Building Smart Microgrid Test-Bed를 이용한 전력사용량 패턴 최적화방안 연구)

  • Lee, Sang-Woo;Kang, Jin-Kyu;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • The microgrid system is the combination of photovoltaic(PV) array, load, and battery energy storage system. The control strategies were defined as multi-modes of operation, including rest operation without use of battery, power charging, and power discharging, which enables grid connected mode or islanded mode. Photovoltaic power is a problem of the uniformity of power quality because the power generated from solar light is very sensitive to variation of insolation and duration of sunshine. As a solution to the above problem, energy storage system(ESS) is considered generally. There fore, in this study, we did basic research activities about optimization method of the amount of energy used, using a smart microgrid test-bed constructed in building. First, we analyzed the daily, monthly and period energy pattern amount of power energy used, and analyzed PV power generation level which is built on the roof. Utilizing building energy pattern analysis data, we was studied an efficient method of employing the ESS about building power consumption pattern and PV generation.

WIRELESS SENSOR NETWORK BASED BRIDGE MANAGEMENT SYSTEM FOR INFRASTRUCTURE ASSET MANAGEMENT

  • Jung-Yeol Kim;Myung-Jin Chae;Giu Lee;Jae-Woo Park;Moon-Young Cho
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1324-1327
    • /
    • 2009
  • Social infrastructure is the basis of public welfare and should be recognized and managed as important assets. Bridge is one of the most important infrastructures to be managed systematically because the impact of the failure is critical. It is essential to monitor the performance of bridges in order to manage them as an asset. But current analytical methods such as predictive modeling and structural analysis are very complicated and difficult to use in practice. To apply these methods, structural and material condition data collection should be performed in each element of bridge. But it is difficult to collect these detailed data in large numbers and various kinds of bridges. Therefore, it is necessary to collect data of major measurement items and predict the life of bridges roughly with advanced information technologies. When certain measurement items reach predefined limits in the monitoring bridges, precise performance measurement will be done by detailed site measurement. This paper describes the selection of major measurement items that can represent the tendency of bridge life and introduces automated bridge data collection test-bed using wireless sensor network technology. The following will be major parts of this paper: 1) Examining the features of conventional bridge management system and data collection method 2) Mileage concept as a bridge life indicator and measuring method of the indicator 3) Test-bed of automated and real-time based bridge life indicator monitoring system using wireless sensor network

  • PDF

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

Test-bed Design for the Evaluation of Wireless Communication System on Small Launch Vehicle (소형 발사체 무선 통신시스템 검증을 위한 테스트 베드 설계)

  • Lee, Dae-Hyun;Oh, TaeckKeun;Park, Dong-Hwa;Lee, Hong-Ki;Park, Dong-Hyun;Song, Ho-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.4
    • /
    • pp.311-318
    • /
    • 2018
  • In this paper, test-bed for the evaluation of wireless communication system on a small launch vehicle is proposed. The proposed test-bed consists of antenna test-coupler, RF attenuators, and RF switch modules. The antenna test-coupler isolates antennas for each band and transmits / receives wireless signals. The RF attenuator and switch are used for path selection of testing signal path. In design and measurement result of the antenna test-coupler, the antenna test-coupler has shielding effect higher than 39.3, 47.1, 56.1 dB at UHF-, S-, X-band. Through testing on small launch vehicle wireless communication system, we were able to successfully transmit and receive data between each test system and launch vehicle with antenna path switching.

Test Bed Design of Fire Detection System Based on Multi-Sensor Information for Reduction of False Alarms (화재감지 오보 감소를 위한 다중정보기반 시스템의 Test Bed 설계)

  • Lee, Kijun;Kim, Hyeong Gweon;Lee, Bong Woo;Kim, Tae-Ok;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.107-114
    • /
    • 2012
  • Fire detection system is used for detection and alarm-generation of danger in case of fire. Most fire detection systems being used these days often malfunction from false positive and false negative errors. To improve detection reliability, an integrated fire detection algorithm using multi-senor information of heat, smoke and carbon monoxide detectors is suggested, then built and tested using the LabVIEW environment. Simulated using sensor measurement data offered by National Institute of Standards and Technology (NIST), possibility of reducing false positive and false negative errors is verified.

Feasibility Test with IoT-based DCPT system for Digital Compaction Information of Smart Construction (스마트건설 디지털 다짐정보 구축을 위한 IoT 기반 DCPT 시스템 현장실증)

  • Kim, Donghan;Bae, Kyoung Ho;Cho, Jinwoo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.40 no.5
    • /
    • pp.421-428
    • /
    • 2022
  • The earthwork is a core process of all constructions, and compaction measurement of earthwork play an important role in improving productivity. The analog tests such as Plate Bearing Test and Sand-cone occupy current compaction measurement techniques. Due to advanced 4th Industrial Revolution, research on analog tests combined smart construction technology are actively conducted. DCPT (Dynamic Cone penetration Test), simpler and faster than conventional tests, has recently on rise. However, it is also an analog that measures data manually and has several disadvantages such as history management and data verification. The IoT-based DCPT system developed in this study combines digital wire sensors, mobile phones, and Bluetooth with conventional DCPT. Compare to conventional test methods, IoT-based DCPT has advantages such as performance time, single-person measurement, low cost, mobile-based management, and real-time data verification. In addition, a test bed was built to verify IoT-based DCPT. The test bed was built under similar conditions to the actual earthworks site through roller equipment. DCPT data obtained from 322 stations. As a result, IoT-based DCPT showed good performance, and the test bed was also showed stable results as the compaction was carried out.

Effects of Nurse Staffing Level on In-hospital Mortality and 30-day Mortality after Admission using Korean National Health Insurance Data (간호사 확보수준이 입원 환자의 병원사망과 입원 30일 이내 사망에 미치는 영향)

  • Kim, Yunmi;Lee, Kyounga;Kim, Hyun-Young
    • Journal of Korean Clinical Nursing Research
    • /
    • v.28 no.1
    • /
    • pp.1-12
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate the association between the nurse staffing level and the patient mortality using Korean National Health Insurance data. Methods: The data of 1,068,059 patients from 913 hospitals between 2015 and 2016 were analyzed. The nurse staffing level was categorized based on the bed-to-nurse ratio in general wards, intensive care units (ICUs), and hospitals overall. The x2 test and generalized estimating equations (GEE) multilevel multivariate logistic regression analyses were used to explore in-hospital mortality and 30-day mortality after admission. Results: The in-hospital mortality rate was 2.9% and 30-day mortality after admission rate was 3.0%. Odd Ratios (ORs) for in-hospital mortality were statistically lower in general wards with a bed-to-nurse ratio of less than 3.5 compared to that with 6.0 or more (OR=0.72, 95% CI=0.63~0.84) and in ICUs with a bed-to-nurse ratio of less than 0.88 compared to that with 1.25 or more (OR=0.78, 95% CI=0.66~0.92). ORs for 30-day mortality after admission were statistically lower in general wards with a bed-to-nurse ratio of less than 3.5 compared to that with 6.0 or more (OR=0.83, 95% CI=0.73~0.94) and in ICUs with a bed-to-nurse ratio of less than 0.63 compared to that with 1.25 or more (OR=0.85, 95% CI=0.72~1.00). Conclusion: To reduce the patient mortality, it is necessary to ensure a sufficient number of nurses by improving the nursing fee system according to the nurse staffing level.

Development of a Test Facility for Cold-air Performance of Small Axial Turbine (소형 축류터빈의 상온 성능시험기 개발)

  • 손창민;차봉준;이대성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1780-1786
    • /
    • 1995
  • The main goal of the present study is to establish the techniques and methodolgies of turbine performance test through evaluating the objective turbine test piece, and checking the reliability of the self-developed test facility by performing a series of turbine tests under ambient temperature condition. A high speed coupling, a lubrication system and a test bed of the test facility were modified through a series of preliminary test in order to reduce the vibration and oil leakage. The flowrate control of the test facility and data acquisition were accomplished by using a software called "Labview" The measurement of shaft horse power and control of rotational speed according to the conditions of turbine rotation were performed by a separate system. The preliminary evaluation of the measured data suggests that the developed test facility and the test technique can be used reliably for the performance test of turbines with the minor improvement.provement.