• Title/Summary/Keyword: Test research

Search Result 38,171, Processing Time 0.061 seconds

Determination of Cyclogram for Liquid-Propellant Rocket Engine

  • Ha, Seong-Up;Kwon, Oh-Sung;Lee, Jung-Ho;Kim, Byoung-Hun;Kang, Sun-Il;Han, Sang-Yeop;Cho, In-Hyun;Lee, Dae-Sung
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.3 no.2
    • /
    • pp.59-66
    • /
    • 2002
  • A vertical test stand based on launcher propulsion system was constructed and several tests for the determination of cyclogram were carried out. To make an accurate estimation, static and dynamic pressures were measured and analyzed. Especially, static pressure measurements using fast response sensors without extension tubes were used to determine operation sequence more evidently. The standard operation times of final valves were determined in cold flow tests with an engine head, and fire formation time in combustion chamber was checked in an ignition test with an ignitor only. On the basis of these tests, ignition sequence was established and combustion test cyclogram was finally determined. According to combustion test, test results were well matched with the determined cyclogram within 0.05 sec.

A configuration plan and future expectation of a power distribution test (배전실증시험장의 구성 방안 및 운용 예상효과 분석)

  • Jeong, Yeong-Ho;Kim, Sang-Joon;Park, Sang-Man
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.829-831
    • /
    • 1997
  • We investigated configuration plan and future expectation of the power distribution test center. The example of foreign country's test center was analyzed, and the required test facilities, test line, and power source for the operation of our test center were proposed.

  • PDF

Certificate Test on Crystalline Silicon Photovoltaic Module (결정질 실리콘 태양전지모듈의 인증시험 현황)

  • Kim, Kyung-Soo;Kang, Gi-Hwan;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.27-30
    • /
    • 2009
  • In this paper, we introduce the status of certificate test on crystalline silicon photovoltaic module in Korea. Up to 3. 2009, about 149 models have passed certificate test under KS C IEC61215 standard. Most products are from Korea, Japan, China. And some are from USA, German and Taiwan. A few environmental test items' results and standard test methods will be discussed. The detail discussion will be shown in the following paper.

  • PDF

A Practical Power System Stabilizer Tuning Method and its Verification in Field Test

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Baek, Seung-Mook;Choy, Young-Do;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.400-406
    • /
    • 2010
  • This paper deals with parameter tuning of the Power System Stabilizer (PSS) for 612 MVA thermal power plants in the KEPCO system and its validation in a field test. In this paper, the selection of parameters, such as lead-lag time constants for phase compensation and system gain, is optimized using linear and eigenvalue analyses. This is then verified through the time-domain transient stability analysis. In the next step, the performance of PSS is finally verified by the generator's on-line field test. After the field test, measured and simulated data are also compared to prove the effectiveness of the models used in the simulations.

INTEGRAL BEHAVIOR OF THE ATLAS FACILITY FOR A 3-INCH SMALL BREAK LOSS OF COOLANT ACCIDENT

  • Choi, Ki-Yong;Park, Hyun-Sik;Cho, Seok;Euh, Dong-Jin;Kim, Yeon-Sik;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • v.40 no.3
    • /
    • pp.199-212
    • /
    • 2008
  • A small-break loss of coolant accident (SB-LOCA) test with a break size equivalent to a 3-inch cold leg break of the APR1400 was carried out as the first transient integral effect test using the ATLAS (Advanced Thermal-hydraulic Test Loop for Accident Simulation). This was the first integral effect test to investigate the integral performance of the test facility and to verify its simulation capability for one of the design-basis accidents. Reasonably good thermal hydraulic data was obtained so that an integral performance of the fluid sub-systems was identified and control performance of the ATLAS was confirmed under real thermal hydraulic conditions. Based on the measured data, a post-test calculation was carried out using the best-estimate thermal hydraulic safety analysis code, MARS 3.1, and the similarity between the expected and actual data was investigated. On the whole, the post-test calculation reasonably predicts the major thermal hydraulic parameters measured during the SB-LOCA test. The obtained data will be used to enhance the simulation capability of the ATLAS and to improve an input model of the ATLAS for simulation of other target scenarios.

An Integration Study of the Firing Test Stage at the Acceptance Test for the Propelling Charge (추진장약 수락시험의 시험단계 통합 연구)

  • Kim, Jaekab;Kim, Jaehoon;Na, Taeheum;Kim, Bokyun;Park, Noseok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • In this paper, the integration of the firing test stages at the acceptance test of the propelling charge has been studied using statistical analysis on the basis of the test data of K676 and K677 propelling charge for K9 self propelled howitzer. Acceptance test of K676 / K677 propelling charge consists of 3 stages and each stage is charge assessment test, charge uniformity test and charge proving ground test. Many of rounds are fired and much money is spent to prove the charge performance at each stage. The result of t-test shows that there is no difference between charge uniformity and charge proving ground test stage of K676 and K677 propelling charge.

Validation of Suitability on Proficiency Testing Samples for Acute Toxicity Test with Daphnia magna (생태독성 숙련도 시료의 적절성 평가)

  • Shin, Kisik;Park, Woosang;Lee, Jungseo;Yu, Soonju;Park, Taejin;Kim, Jongmin
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.49-54
    • /
    • 2015
  • Acute toxicity test with Daphnia magna has a variety of factors such as incubation condition of test species, food quality and proficiency of laboratory workers. Therefore, proper proficiency testing samples were required for evaluating the competence of laboratory workers. This study aims to propose some appropriate proficiency testing samples for laboratory workers of acute toxicity test with Daphnia magna. Proposed four kinds of standard samples (Sample A, B, C, and D) for proficiency testing were selected from reference materials which were recommended from Canada and USA WET(Whole Effluent Toxicity) authorities. Proposed standard samples were tested by trial application of proficiency testing, homogeneity and stability checks using repeatability test. Sample A, C and D were estimated ad the suitable candidates for proficiency test standard samples except for Sample B. In addition, Sample A was proved to be the most suitable sample.

A survey on the infection rate of Dirofilaria immitis of dogs in Daegu area (대구지역 개의 심장사상충 감염실태)

  • Lim, Hyun-Sook;Cho, Yoo-Joung;Suh, Dong-Kyun;Song, Dong-Jun;Lee, Chun-Sik;Bae, Young-Chan
    • Korean Journal of Veterinary Service
    • /
    • v.26 no.2
    • /
    • pp.129-134
    • /
    • 2003
  • A survey of canine heartworm(Dirofilaria immitis) infections among dogs in Daefu area was performed from February 2000 to October 2002 using a microfilarial test and an antigen test(AGEN$^{TM}$ Canine heartworm). The infection rate of 220 dogs(96 males, 124 females) was 23.2%(51/22) by the microfilarial test, but was 23.6%(52/220) by the antigen test, revealing that 1 of 52 antigen-positive dogs were microfilaria-negative in the peripheral blood. All dogs that were microgilaria-positive were also antigen-positive. The infection rates of heartworm in dogs at the age of < 1, 1-3, 4-6, 7-11 and 12-15 years were 2.7%, 17.4%, 41.0%, 42.9% and 57.1%, respectively. Based on the fact that the antigen test is more accurate than the microfilaria test. The infection rates of heartworm in dogs by housing of indoor and outdoor were 6.9% and 46.4%, respectively. Based on the fact that outdoor housing is more infectious than indoor housing.

Performance Test for the SIGMA Communication System

  • Jeong, Seonyeong;Lee, Hyojeong;Lee, Seongwhan;Shin, Jehyuck;Lee, Jungkyu;Jin, Ho
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.4
    • /
    • pp.335-344
    • /
    • 2016
  • Scientific CubeSat with Instruments for Global Magnetic Fields and Radiations (SIGMA) is a 3-U size CubeSat that will be operated in low earth orbit (LEO). The SIGMA communication system uses a very high frequency (VHF) band for uplink and an ultra high frequency (UHF) band for downlink. Both frequencies belong to an amateur band. The ground station that communicates with SIGMA is located at Kyung Hee Astronomical Observatory (KHAO). For reliable communication, we carried out a laboratory (LAB) test and far-field tests between the CubeSat and a ground station. In the field test, we considered test parameters such as attenuation, antenna deployment, CubeSat body attitude, and Doppler frequency shift in transmitting commands and receiving data. In this paper, we present a communication performance test of SIGMA, a link budget analysis, and a field test process. We also compare the link budget with the field test results of transmitting commands and receiving data.

The Experimental Study of SPM(Selectively Permeable Membrane Materials) by using Aerosol Test Instrument (에어로졸 시험장비를 이용한 방호 의복 소재의 여과 효율에 대한 연구)

  • Kwon, Tae Geun;Seo, Hyeon Kwan;Kim, Jin Won;Kang, Jae Sung;Kang, Ki Tae;Ahn, Kang Ho;Choi, Jin Soo;Cho, Jae Ho;Kwon, Yong Taek;Park, Hyen Bae
    • Particle and aerosol research
    • /
    • v.10 no.3
    • /
    • pp.109-117
    • /
    • 2014
  • In Korea, permeable protection clothes for chemical agent is being developed and distributed. But permeable protection clothes are vulnerable for biological agent of particle type. Therefore selective permeable membranes are being developed to protect chemical agent and biological agent simultaneously. In this study, aerosol collection efficiency test was performed to validate the protection performance of permeable clothes and selective permeable membranes. Aerosol collection efficiency test was performed by using the aerosol test equipment that could test aerosol particle diameter from $0.005{\mu}m$ to $3.0{\mu}m$. This study shows the test method and performance test results for collection efficiency by using the aerosol test equipment.