• Title/Summary/Keyword: Test program set

Search Result 517, Processing Time 0.029 seconds

The Effects of McKenzie Exercise on Forward Head Posture and Respiratory Function

  • Kim, SeYoon;Jung, JuHyeon;Kim, NanSoo
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.6
    • /
    • pp.351-357
    • /
    • 2019
  • Purpose: This study sought to investigate the effects of the McKenzie exercise program on forward head posture and respiratory function. Methods: Thirty adult men and women with forward head posture, aged 20-29 years, were randomly assigned to the experimental group (N=15) or the control group (N=15). Subjects in the experimental group performed the McKenzie exercises three times a week for four weeks, while subjects in the control group did not receive any intervention. Craniovertebral angle (CVA) was measured to quantify forward head posture, and forced vital capacity (FVC), FVC % predicted, forced expiratory volume at one second (FEV1), and FEV1 % predicted were measured to determine changes in respiratory function. The Mann-Whitney U-test was used to analyze pre-test differences in forward head posture and respiratory function between the two groups, and the Wilcoxon signed-rank test was used to analyze differences in forward head posture and respiratory function within the groups before and after intervention. The significance level (α) was set to 0.05. Results: A comparison of pre- and post-test measures showed that CVA significantly increased in the experimental group (p=0.001) denoting postural improvement, whereas no significant difference was found in the control group (p=0.053). All respiratory measures, i.e.,FVC, FVC %pred, FEV1, and FEV1 %pred, were significantly improved in the experimental group, whereas there were no significant differences in the control group. Conclusions: McKenzie exercise can be effective in improving forward head posture and respiratory function.

Evaluation of strength according to surface abrasion of lithium disilicate glass ceramic by 3-point bending strength test (3점 굽힘강도 시험을 통한 Lithium disilicate glass ceramic의 표면 연마 정도에 따른 강도 평가)

  • Lee, Ha-Na;Kim, Eo-Bin;Kang, Seen-Young;Lee, Kyung-Eun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.1
    • /
    • pp.9-15
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of lithium disilicate glass ceramic polishing on the strength of the final prosthesis. Methods: Fourteen lithium disilicate glass ceramic specimens were prepared. These were randomly divided into two groups of seven(LPG: low polishing group, HPG: high polishing group). In LPG, SiC paper was sequentially polished using 300, 600, 800, 1000 grit, and the specifications of the test piece were adjusted. HPG was sequentially polished using 300, 600, 800, 1000, 1200, 1500, and 2000 grit. Two groups of specimens are executed 3- point bending test. Using the statistical program SPSS 22.0, the average values of the strengths of the two groups were compared in the Mann-Whiteney test. The significance level was set at 0.05. Results: The mean strength value of HPG was measured at $307.14{\pm}23.28MPa$ significantly higher than LPG(p<0.001). Conclusion : The final polishing of the prosthesis is aesthetically important but has proven to play an important role in the flexural strength, early fracture, and prolongation of the prosthesis.

Implementation of ATE to Maintain Pre-Amplifier of Thermal Imaging System (열상장비 전단증폭부 정비용 ATE의 구현)

  • Park, Jai-Hyo;Kim, Han-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.80-87
    • /
    • 2012
  • We have developed the ATE(Automatic Test Equipment) system for the performance test of pre-amplifier of thermal imaging devices. The device regenerates the electronic signals of photon detection module which is normally in weak energy, for the image signals processing. Previous ATE system was primarily and actively developed in the field of semiconductor devices quality parts inspection. Recently, it has been studied in the field of performance testing of equipment. In the field of thermal performance test equipment, however, it lacks the study of ATE compared to other areas, which causes the maintenance related to the core of military thermal imaging system maintenance to be limited. In this paper, a new study of ATE in the field of thermal imaging system is done. It is designed to be used universally for the ATE system with different types of circuit card of thermal imaging system by adopting matrix relays. Using the developed ATE measuring the pre-amplifier amplitude, an average amplified amplitude of 2.71Vpp was measured which confirms that it is within the range of theoretical analysis and also verifies the good performance of the developed ATE.

The Effects of Upper and Lower Limb Coordinated Exercise of PNF for Balance in Chronic Stroke Patients (고유수용성신경근촉진법의 상하지 협응 운동이 만성 뇌졸중 환자의 균형 능력에 미치는 효과)

  • Cho, Hyuk-Shin;No, Hyun-Jeong
    • PNF and Movement
    • /
    • v.13 no.1
    • /
    • pp.9-16
    • /
    • 2015
  • Purpose: This study aimed to examined the effects of upper and lower limb coordinated exercise of proprioceptive neuromuscular facilitation (PNF) on static and dynamic balance ability. Methods: The subjects of this study were 18 patients who had been diagnosed with a stroke and hospitalized and who had received rehabilitation treatment at D rehabilitation hospital located in J city. They were randomly and equally assigned to a PNF upper and lower limb coordinated exercise group and an ordinary central nervous system development and treatment group, and they conducted exercises for eight weeks. They carried out exercise three times per week, for 30 minutes per each time. After each four minutes of exercise, each participant was given a and rest for one minute after exercise for four minutes was given. In order to test the subjects' static and dynamic balance ability and their dynamic balance ability, frailty and injuries,: a cooperative studyies of intervention techniques (FICSIT-4) test, a four- step square test (FSST), a timed up and go test (TUG), and a TWT3M tests wasere conducted before and after the exercise. Descriptive statistics were taken for the general characteristics of the subjects, and an independent t-test was conducted both before and after the exercise in order to examine differences between the two groups before and after the exercise were conducted. The A statistical significance level was set at p= 0.05. Results: In all the tests (of FICSIT-4, FSST, TUG, and TWT3M), both the experimental group and the control group saw more improved results, but the experimental group's results were significantly higher than those of the control group, and the size of the effects was larger in the experimental group than in the control group, with statistically significant results. Conclusion: PNF upper and lower limb coordinated exercise applied to chronic stroke patients produced brought significant results in static and dynamic balance ability. PNF and is considered as an important intervention program to improve stroke patients' balance ability.

Development of Model for 「The Survey on School Foodservice Program」 (「학교급식 실태조사」를 위한 모형 개발)

  • Lee, Hae-Young;Yi, Bo-Sook;Cha, Jina;Ham, Sun-Ok;Park, Moon-Kyung;Lee, Mi-Nam;Kim, Hye-Young;Kang, Haeng-Hwa;Kwon, Jin-Wook;Jeong, Yun-Hui
    • Korean Journal of Community Nutrition
    • /
    • v.24 no.1
    • /
    • pp.60-76
    • /
    • 2019
  • Objectives: The purpose of this study was to develop a systematic and standardized "The Survey on School Foodservice Program" that can identify the current status of school meals on the nationwide level. Methods: This study was carried out in six steps of the analysis of report/investigation data related to school foodservice in metropolitan and provincial offices of education, analysis of preceding research related to the actual status of school foodservice, field verification of the actual condition of the school foodservice site, development of a draft of "The Survey on School Foodservice Program", pilot study of a draft of "The Survey on School Foodservice Program", and suggestions of a final model of "The Survey on School Foodservice Program" from August to December, 2017. Statistical analysis was performed for frequency analysis and descriptive analysis using the SPSS program ver. 23. Results: A draft of "The Survey on School Foodservice Program" was developed by analyzing the current status of report/research data on school meals in metropolitan and provincial offices of education, analyzing the preceding research on school meals, and identifying the actual conditions at school foodservice sites. To verify the validity of the school foodservice survey questionnaire, 1,031 schools were sampled from a total of 10,251 schools and the pilot test of '2017 School Foodservice Survey' was conducted. The final model of "The Survey on School Foodservice Program" consisted of 12 survey sections, 29 survey categories, and 433 survey items, and the survey cycle was set for one year and three years for each survey item. Conclusions: Based on the objective statistical data through "The Survey on School Foodservice Program", it is possible to develop the school foodservice policy, which will help establish the reliability of the school meals.

Comparison on the Performance of Soil Improvement in Thick Soft Ground Using Single-Core and Double-Core PBD (단일 및 이중 코어 PBD에 의한 대심도 연약지반 개량 효과에 관한 비교연구)

  • Yang, Jeong-Hun;Hong, Sung-Jin;Kim, Hyung-Sub;Lee, Woo-Jin;Choi, Hang-Seok
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.8
    • /
    • pp.33-45
    • /
    • 2009
  • The conventional single-core PBDs have been widely used in order to accelerate consolidation settlement of soft grounds. When using the single-core PBD in a thick clay deposit, a delay of consolidation may occur due to high confining pressure in the thick deposit and necking of drains. This study is to compare the performances of soil improvement by the single-core and double-core PBD installed at a site in Busan New Port which exhibits approximately a 40m-thick clay layer. An in-situ test program was performed at the test site where a set of the double-core PBDs and single-core PBDs were installed to compare the efficiency of each drain. In addition, the discharge capacity of each PBD has been measured using the modified Delft Test. A series of laboratory tests for estimating in-situ soil properties have also been performed in order to obtain input parameters for a numerical program ILLICON. The discharge capacity of the double-core PBD is higher than that of the single-core PBD in the modified Delft Test. However it is observed from the comparative in-situ test and numerical analysis that there is no difference in the performance of ground improvement between the two drain systems. This discrepancy comes from the fact that the amount of water released during consolidation in most common field conditions is much smaller than the capacity of even the single core PBD. And thus, considering actual field conditions, it can be concluded that the single-core PBD has enough discharge capacity even in the thick clay deposit such as this test site.

Fast Combinatorial Programs Generating Total Data (전수데이터를 생성하는 빠른 콤비나토리얼 프로그램)

  • Jang, Jae-Soo;Won, Shin-Jae;Cheon, Hong-Sik;Suh, Chang-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1451-1458
    • /
    • 2013
  • This paper deals with the programs and algorithms that generate the full data set that satisfy the basic combinatorial requirement of combination, permutation, partial permutation or shortly r-permutation, which are used in the application of the total data testing or the simulation input. We search the programs able to meet the rules which is permutations and combinations, r-permutations, select the fastest program by field. With further study, we developed a new program reducing the time required to processing. Our research performs the following pre-study. Firstly, hundreds of algorithms and programs in the internet are collected and corrected to be executable. Secondly, we measure running time for all completed programs and select a few fast ones. Thirdly, the fast programs are analyzed in depth and its pseudo-code programs are provided. We succeeded in developing two programs that run faster. Firstly, the combination program can save the running time by removing recursive function and the r-permutation program become faster by combining the best combination program and the best permutation program. According to our performance test, the former and later program enhance the running speed by 22% to 34% and 62% to 226% respectively compared with the fastest collected program. The programs suggested in this study could apply to a particular cases easily based on Pseudo-code., Predicts the execution time spent on data processing, determine the validity of the processing, and also generates total data with minimum access programming.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Pharmacophore Modeling and Molecular Dynamics Simulation to Find the Potent Leads for Aurora Kinase B

  • Sakkiah, Sugunadevi;Thangapandian, Sundarapandian;Kim, Yong-Seong;Lee, Keun-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.3
    • /
    • pp.869-880
    • /
    • 2012
  • Identification of the selective chemical features for Aurora-B inhibitors gained much attraction in drug discovery for the treatment of cancer. Hence to identify the Aurora-B critical features various techniques were utilized such as pharmacophore generation, virtual screening, homology modeling, molecular dynamics, and docking. Top ten hypotheses were generated for Aurora-B and Aurora-A. Among ten hypotheses, HypoB1 and HypoA1 were selected as a best hypothesis for Aurora-B and Aurora-A based on cluster analysis and ranking score, respectively. Test set result revealed that ring aromatic (RA) group in HypoB1 plays an essential role in differentiates Aurora-B from Aurora-A inhibitors. Hence, HypoB1 used as 3D query in virtual screening of databases and the hits were sorted out by applying drug-like properties and molecular docking. The molecular docking result revealed that 15 hits have shown strong hydrogen bond interactions with Ala157, Glu155, and Lys106. Hence, we proposed that HypoB1 might be a reasonable hypothesis to retrieve the structurally diverse and selective leads from various databases to inhibit Aurora-B.

Approximate Shape Optimization Technique by Sequential Design Domain (순차설계영역을 이용한 근사 형상최적에 관한 연구)

  • 김우현;임오강
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.1
    • /
    • pp.31-38
    • /
    • 2004
  • Mechanical design process is generally accomplished by design, analysis, and test. Designers use programs fitting purpose, and obtain repeatedly a response of a simulation program, a sub-program for optimization. In this paper, shape optimization using approximate optimization technique is carried out with sequential design domain(SDD). In addition, algorithm executing Pro/Engineer and ANSYS automatically are adopted in the approximate optimization program by SDD. It is difficult for design problem to be approximated accurately for the whole range of design space. However, more or less accurate approximation is constructed if SDD is applied to that case. SDD starts with a certain range which is off-seted from midpoint of an initial design domain and then SDD of the next step is determined by a move limited. Convergence criterion is defined such that optimal point must be located within SDD during the two steps. Also, the PLBA(Pshenichny-Lim-Belegundu-Arora) algorithm is used to solve approximate optimization problems. This algorithm uses the second-order information and the active set strategy, in order to seek the direction of design variables.