• Title/Summary/Keyword: Test plan

Search Result 1,800, Processing Time 0.036 seconds

A Study on Planning of Waterfront Belt in Busan Coastal Area (부산 해안지역 친수공간벨트계획에 관한 연구)

  • Lee, Han-Seok;Lee, Jung-Woo;Ahn, Woong-Hi
    • Journal of Navigation and Port Research
    • /
    • v.31 no.10
    • /
    • pp.885-890
    • /
    • 2007
  • The purpose of this study is for providing a strategic plan of waterfront belt development at the coastal area of Busan city that might enhance the possibility on healthy use of spare time of the residents and demand of tourism, together with raising the potential and the value added effect of coastal space. This study is one of a series of studies for developing waterfront belt at Busan coastal area. In this study we suggest the new concepts of waterfront belt, waterfront cluster and waterfront greenway. And then we present a model of making waterfront belt through waterfront cluster, which is an aggregate of individual waterfront spaces, using waterfront greenway. After that we apply this model to Haeundae coastal area and test the applicability of the model.

The Construction of Planning Objectives for School Facilities: An Empiric Case Study in Chunan Chungnam, Korea (학교시설(學校施設) 계획(計劃)의 목표(目標) 설정(設定): 천안(天安)의 경험적(經驗的) 사례(事例) 연구(硏究))

  • Min, Chang-Kee
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.6 no.3
    • /
    • pp.36-46
    • /
    • 1999
  • This paper seeks to show the factors, such as area and building conditions, exterior spatial conditions, and educational equipment, which affect student learning and rest activities in the school facilities. It also develops the order for the factors related to the activities. It collected available data at Shangyoung and Bongsoa Middle Schools in Chunan Chungnam, Korea. Using a t-test and multiple regression analyses, it found the factors affecting activities in different schools. It found that the facility and equipment conditions of the two schools are different. It also found that the planning objectives such as the adaptability of the facilities and equipment, information technology of the equipment, student supervision, and convenience of use of the facilities, in order, are important for planning for new buildings in urban area. And the planning objectives such as the adaptability of the facilities and equipment, the safety of the building, the convenience of use of the facilities, aesthetics, information technology of the equipment, the degree of health benefits are important in order to plan for the renovation of school buildings in urban areas. Thus, it asserts that, considering the planning objectivies developed above, a planner can construct planning objectives for new constuction or renovation of school buildings.

  • PDF

Statistical Approach for Corrosion Prediction Under Fuzzy Soil Environment

  • Kim, Mincheol;Inakazu, Toyono;Koizumi, Akira;Koo, Jayong
    • Environmental Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • Water distribution pipes installed underground have potential risks of pipe failure and burst. After years of use, pipe walls tend to be corroded due to aggressive soil environments where they are located. The present study aims to assess the degree of external corrosion of a distribution pipe network. In situ data obtained through test pit excavation and direct sampling are carefully collated and assessed. A statistical approach is useful to predict severity of pipe corrosion at present and in future. First, criteria functions defined by discriminant function analysis are formulated to judge whether the pipes are seriously corroded. Data utilized in the analyses are those related to soil property, i.e., soil resistivity, pH, water content, and chloride ion. Secondly, corrosion factors that significantly affect pipe wall pitting (vertical) and spread (horizontal) on the pipe surface are identified with a view to quantifying a degree of the pipe corrosion. Finally, a most reliable model represented in the form of a multiple regression equation is developed for this purpose. From these analyses, it can be concluded that our proposed model is effective to predict the severity and rate of pipe corrosion utilizing selected factors that reflect the fuzzy soil environment.

Preliminary Design of Korea's First mobile SLR system

  • Jo, Jung-Hyun;Seo, Yoon-Kyung;Lee, Jin-Young;Yim, Hong-Seo;Lim, Hyung-Chul;Park, Eun-Seo;Park, Jang-Hyun;Park, Jong-Uk
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.36.2-36.2
    • /
    • 2010
  • Followed the System Design Review (PDR) of a mobile SLR (Satellite Laser Ranging) system, a successful preliminary design review was finished in 2009. With the completion of this mobile SLR system, KASI (Korea Astronomy and Space Science Institute) can perform a series of test observation and calibration/validation procedures. After the operation performance of the whole system reaches the nominal design, a regular scheduled observation will be executed. However, the project has been disturbed by the frequent change of working staff, budget profile, and plan as well as the inexperienced man power. In this study, the contents and the issues of PDR are briefly reviewed and several items of SLR system are suggested. This mobile SLR system will push Korea's Space Geodetic study further and will make us jump to another step to the Space Science in Korea.

  • PDF

Transmission System Expansion Planning by Nodal Delivery Marginal Rate Criterion -II (모선수송전달능력(母線輸送傳達能力) 신뢰도 기준에 의한 송전계통(送電系統)의 광역설계(擴充計劃) -II)

  • Park, Jeong-Je;Shi, Bo;Jeong, Sang-Hun;Choi, Jae-Seok;Mount, Timothy;Thomas, Robert
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.574-575
    • /
    • 2007
  • This paper proposes a method for choosing the best transmission system expansion plan using nodal/bus delivery marginal rate criterion ($BMR_k$) defined newly in this paper. The objective method minimizes a total cost which is an investment budget for constructing new transmission lines subject to the $BMR_k$ which means a nodal deterministic reliability level requirement at specified load point. The proposed method models the transmission system expansion problem as an integer programming problem. It solves for the optimal strategy using a branch and bound method that utilizes a network flow approach and the maximum flow-minimum cut set theorem. Test results on an existing 21-bus system are included in the paper. It demonstrated the suitability of the proposed method for solving the transmission system expansion planning problem in competitive electricity market environment.

  • PDF

Risk Assessment of Integrated Leak Rate Test(ILRT) Extension for Korea Standard Nuclear Power Plant (한국표준형원전의 격납건물종합누설률 시험 주기연장에 대한 리스크 평가)

  • Chi, Moon-Goo;Hwang, Seok-Won;Oh, Ji-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.99-104
    • /
    • 2011
  • An ILRT Interval for a nuclear power plant in Korea was extended from once in five years to once in ten years. Therefore, it is necessary to evaluate risk impact for ILRT interval extensions. In this paper, input data were generated for the reference plants, KSNP, using raw data such as meteorological data, population distribution data and source term data. And, using MACCS II code the risk impact assessment was performed based on the two methodologies of NUREG-1493 and NEI Interim Report. The risk impact derived from an ILRT interval extension was identified not to be significant. It is considered to apply this study and results to making an accident management plan and safety goal, and to the field of public acceptance.

A Study on the Technology Development and Application Plan for making an Integrated Digital Map of an Electronical Navigational Chart and a Digital Terrain Map (육.해도 통합수치도 제작 기술 개발과 응용 방안+)

  • 이기철;정희균;박창호;서상현;김정희
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.347-356
    • /
    • 1999
  • This study is to develop the technology and the ways of the practical use of the integrated digital map of and Electronical Navigational Chart(ENC) and Digital Terrain Map(DTM) for the effective and scientific based conservation, development and management. In this study, as preliminary studies to make eventual integrated maps, the concept of coastal areas are defined and the characteristics of digital maps developed by Korean Geography Institute and National Marine Investigation Institute are carefully analyzed. A test coastal map was developed based on the integrated digital map, a high resolution satellite image and Global Positioning System. Results from the edge matching analysis of coastal lines shows 8 meters difference in maximum. The problems, causes and solutions for the edge matched differences are described. Furthermore, the practical value of utilization, future use and various field of application are described based on the integrated digital map data base of coast area.

  • PDF

Condition Evaluation Method of Satellite Communication Facilities for Hydrological Observation (수문관측용 위성통신설비 상태평가 기법)

  • Shin, Gang-Wook;Hong, Sung-Taek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.3030-3037
    • /
    • 2013
  • Life time of facilities is different In case of operating environment and frequency of use. So, the durable year of the facilities is only considered to replace the facilities at present. Thus, system management is needed economical assesment based on condition evaluation through performance analysis of facilities. This research makes a proposal for scientific condition evaluation table through physical assessment, performance analysis assessment, durable years assessment about satellite communication facilities being used in K-water. Consequentially, reasonable replacement plan is established for satellite communication facilities.

A Study on Performance Characteristics with the Control System of CNG Regulator (CNG 레귤레이터의 제어 방식에 따른 성능특성 연구)

  • Seo, Ji-Won;Yang, Jeong-Jik;Kim, Jin-Ho;Lim, Jong-Wan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.3
    • /
    • pp.33-38
    • /
    • 2017
  • The domestic vehicles remodeling the "CNG Bi-fuel Kit" are mostly in operation with installing the mechanical regulator applying the Diaphragm. However, due to the material characteristics of Diaphragm and characteristics of mechanical pressure control method, various problems are happening. This study tries to deduce the improvement plan through the checking of performance characteristics according to the pressure control method of CNG regulator and progress of comparative analysis. According to the test result, the decompression method applying the Diaphragm has advantage compared to the method applying the Piston. Furthermore, it was confirmed that through the electronic pressure control, it is possible to improve the general performance of the regulator.

Daily Unit Commitment Scheduling of Power System with Energy Storage System (전력저장장치를 고려한 일간 최적 기동정지계획 수립연구)

  • Song, Ha-Na;Jang, Se-Hwan;Kim, Hyeong-Jung;Roh, Jae-Hyung;Park, Jong-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.717-725
    • /
    • 2011
  • In the power system with an electric storage system that can increase utilization rate of the source of such new renewable energy, this paper introduces the approach on the daily unit commitment scheduling that determines simultaneously optimum operational condition and output of thermal generators and electric storage device. The unit commitment is one of the most important issues in economic operation and security of short-term operational plan of the power system. It is to determine on/off status of generator to minimize operational cost during the given period. The committed generator should satisfy various operational limitation such as estimated demand by system, spinning reserve condition within minimum operational cost. In order to determine on/off or charge/discharge/idle condition and output level of units and electric storage system, the MILP(Mixed Integer Linear Programming) is suggested. The proposed approach is the mixed method between LP(Linear Programming) and IP(integer programming) which seeks the value of real number and integer that maximize or minimize function objective within given condition. The daily unit commitment problem with the electric storage system is applied to MILP algorithm through linearization and formulation process. The proposed approach is applied to the test system.