• 제목/요약/키워드: Test method for resistance to root penetration

검색결과 5건 처리시간 0.017초

생태교량 적용을 위한 방수·방근공법의 Mock-up 시험 연구 (A Study on the Mock-up Test of Waterproofing/Root Penetration Resistance Technology for the Application to an Eco-bridge)

  • 선윤숙;최수영;김명지;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.230-231
    • /
    • 2014
  • This study is concerned with the root penetration resistance competence and constructability of a waterproofing and root penetration resistance layer of an eco-bridge which is applied with various types of seeding. For the review of root penetration resistance competence, the competence was tested using herbs, woody plants, and tall trees. As a result, there was no tear of or damage to the waterproofing and root penetration resistance layer as well as the sweeping-down phenomenon of a waterproofing and root penetration resistance layer by soil. Also, the effect of the root growth of herbs, woody plants, and tall trees on the root penetration resistance system was confirmed.

  • PDF

인공지반녹화용 멤브레인 방수 및 방근재료의 방근성능 평가 방법 제안 연구 (A Standard Test Methods of Resistance to Root Penetration for Waterproofing and Rootproofing Membrane Using Green Roof System)

  • 이정훈;선윤숙;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.141-148
    • /
    • 2009
  • The purpose of this paper is to propose a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. Green roof system is considered to be an important subject in construction industry for green growth project. At the same time, we have to consider the counterplan for protection the damage of waterproofing layer and concrete substrate from the penetration of plant root. But many kinds of materials for protection from root penetration are using in construction field. But the performance of those materials is not clear, and there is not test methods for the evaluation of performance. So in this paper, based on the research results of 4 institutes during four years and foreign cases, we made a standard test methods of resistance to root penetration for waterproofing and rootproofing membrane using green roof system. This test method deals with about environmental condition of laboratory, experimental facilities, kinds of plant, specimen of test, management methods, evaluation duration and documents, etc.

  • PDF

옥상 및 인공지반녹화용 방근재의 성능기준 설정을 위한 방근성 시험방법에 관한 연구 (A Study on Test Methods for Performance Appraisal of Root Barrier Appling to Green Roofs)

  • 오상근;곽규성;선윤숙;권시원
    • 한국건축시공학회지
    • /
    • 제7권1호
    • /
    • pp.79-84
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we would suggest 5 items of test methods considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, size of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

옥상녹화 및 인공지반녹화용 구리시트 방근재의 성능평가에 관한 연구 (A Study on the Performance Appraisal for Copper Sheet as Root Barrier Material Appling to Green Roof System)

  • 조일규;권시원;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.5-8
    • /
    • 2007
  • Selection of proper root barrier as destination part of greening is very important in Root penetration resistance plan. To select proper root barrier, it need to understand composition of greening part, size, kind of plant, connection with waterproofing layer. In this point of view, we have establish greening on the roof or concrete structure, not been understand the structural mechanism. It means that we misunderstood about purpose of greening and using it. So, chosen materials and construction method was not proper for greening, it caused water leakage and decrease performance of concrete structure. Therefore, we examine the practical use of copper sheet considering environmental condition for green roof. Watertightness by water of greening part, root penetration resistance test by root penetration, bacteria resistance by must or bacteria in soil, chemical resistance by rain and chemical agent of fertilizer, and load resistance by soil depth, sire of plant. These suggested test methods could be referred as guideline to test in green roof system because of not exist any performance appraisal guideline or standard. Consequently, it should be analysis as technical and institutional subdividing test methods and it need to study constantly as varied angles.

  • PDF

조경 녹화용 방수.방근층의 방근 성능평가 시험방법에 관한 연구 - 모의 바늘과 지하경을 이용한 방근 성능평가 시험방법 - (A Study on Test Method for Evaluating Root Resistance in Waterproofing and Root Resistance Membrane Used in Landscape Architecture - A Test Method for Evaluating Root Resistance that Use a Simulated Needle and a Rhizome -)

  • 이준호;표순주;신진학;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 산업계
    • /
    • pp.89-97
    • /
    • 2009
  • As landscaping building roofs and concrete structures increase gradually for low carbon green growth policy of government, But waterproofing membranes of those structures are effecting by root penetration of landscape plant. 80, we progressed study about test method for fast evaluating root resistance of waterproofing materials jointly with Tokyo Institute of Technology. The result of the study is as follows: (1) The penetrating load of the needle at the displacement speed of 1mm/min was measured for various membrane to basis and lap joints of membrane, the load force was $3{\sim}50$ N by material variously. (2) According to the test method of deriving rhizomes of bamboo grass to basis and lap joints of membrane, there were no penetrated membrane until present, but need persistent observation. (3) Test method of deriving rhizomes of bamboo grass to basis and lap joints of membrane can shorten from period of 2 years to 1 year for testing. Because rhizomes of bamboo grass can grow from May to September, test is possible in same period.

  • PDF