• Title/Summary/Keyword: Test for Resistance to Cracking

Search Result 152, Processing Time 0.03 seconds

Full-scale testing on the flexural behavior of an innovative dovetail UHPC joint of composite bridges

  • Qi, Jianan;Cheng, Zhao;Wang, Jingquan;Zhu, Yutong;Li, Wenchao
    • Structural Engineering and Mechanics
    • /
    • v.75 no.1
    • /
    • pp.49-57
    • /
    • 2020
  • This paper presents a full-scale experimental test to investigate the flexural behavior of an innovative dovetail ultra-high performance concrete (UHPC) joint designed for the 5th Nanjing Yangtze River Bridge. The test specimen had a dimension of 3600 × 1600 × 170 mm, in accordance with the real bridge. The failure mode, crack pattern and structural response were presented. The ductility and stiffness degradation of the tested specimens were explicitly discussed. Test results indicated that different from conventional reinforced concrete slabs, well-distributed cracks with small spacing were observed for UHPC joint slabs at failure. The average nominal flexural cracking strength of the test specimens was 7.7 MPa, signifying good crack resistance of the proposed dovetail UHPC joint. It is recommended that high grade reinforcement be cooperatively used to take full advantage of the superior mechanical property of UHPC. A new ductility index, expressed by dividing the ultimate deflection by flexural cracking deflection, was introduced to evaluate the post-cracking ductility capacity. Finally, a strut-and-tie (STM) model was developed to predict the ultimate strength of the proposed UHPC joint.

Evaluation of durability of an ECC(Engineered Cementitious Composite) designed with ground granulated blast furnace slag (고로슬래그 미분말이 혼입된 ECC(Engineered Cementitious Composite)의 내구성 평가)

  • Kim, Jeong-Su;Kim, Yun-Yong;Kim, Jin-Keun;Ha, Gee-Joo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.329-332
    • /
    • 2006
  • This paper presents the experimental results for durability of an ECC designed with ground granulated blast furnace slag (BFS) through the test method of chloride ion resistance and freezing-thawing resistance. In order to compare with ECC, normal mortar was also tested. Test results showed that BFS ECC exhibited higher durability performance than ordinary mortar. These results suggest that by adding BFS in ECC, its matrix density is increased which results in decreased of deterioration and it also adds to the fiber bridging that contributes in control of cracking.

  • PDF

A Study on Stress Corrosion of Al-8ti-1B Alloys by Mechanical Alloying (기계적 합금화한 Al-8Ti-1B 합금의 응력부식에 관한 연구)

  • 김기주;강성군;백영남
    • Journal of the Korean institute of surface engineering
    • /
    • v.27 no.4
    • /
    • pp.215-222
    • /
    • 1994
  • The role dispersoids has been studied in a number of researches as a key point for the high strength application of dispersion strengthened aluminum alloy. The mechanical alloying(MA) process with high mechanical properties of dispersion strengthened MA Al-8Ti-1B alloys were invested in order to evaluate their stress corrosion cracking(SCC) application. SCC properties of the mechanically alloyed Al-8Ti-1B were studied using slow strain rate test(SSRT). In this study Al-8Ti-1B alloy were more susceptible to SCC in solutions of pH=2.01 and 13.2 than pH=6.81 solution. In this study Al-8Ti-1B alloys by MA had more SCC resistance than Al-8Ti alloys or Al 7075-T73 alloys. So Al-8Ti-1B alloys by MA had more resistance in SSRT SCC susceptinility test than any other above alloying metals.

  • PDF

Effect of corrosion environment on the SCC of Al-brass tube for vessel (선박용 Al-황동세관의 SCC에 미치는 부식환경의 영향)

  • 임우조;정해규
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.4
    • /
    • pp.291-297
    • /
    • 2003
  • Al-brass is usually used as the tube material of vessel's heat exchanger for seawater cooling system because it has high thermal conductivity and good mechanical properties and high corrosion resistance due to cuprous oxide (Cu20) layer against seawater. However, Al-brass tubes of heat exchanger for vessel at the actual environment is reported that local corrosion such as stress corrosion cracking occurred by synergism effect between mechanical factor and corrosion environment In this paper, the effect of corrosion environment on the stress corrosion cracking of Al-brass in various NH4OH of 3.5% NaCl solution, under flow by constant displacement tester. Based on the test results, the behavior of polarization, stress corrosion crack propagation and dezincification phenomenon of Al-brass are investigated. The main results are as follows:(1) Increasing range of potential from open circuit potential to repassivation gets lower, as the contain rate of NH4OH gets higher. (2) As contain rate of NH4OH gets higher, SCC of Al-brass is become activation but the protection film(Cu20) of Al-brass is created in 3.5% NaCl solution. (3) According as content of NH4OH increases in 3.5% NaCl solution, the dezincifiction area is spread. It is concluded that dezincification occurred by localized preferential anodic dissolution at stress focusing region.

Assessment of Hydraulic Conductivity of Modified Bentonite and Local Soil Mixture under Salt Water Condition (개량 벤토나이트와 현장토 혼합 차수층의 염수조건하에서의 투수성 평가)

  • Xu, Xin;Oh, Myounghak;Park, Junboum
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.11
    • /
    • pp.97-104
    • /
    • 2017
  • A bentonite mixing with local soil widely used as liner layer for landfill should have low permeability less than $1{\times}10^{-7}cm/s$. But there are several limitations of bentonite used as liner layer, such as drying shrinkage cracking, ineffective waterproof ability under salt water condition like flocculation under sea water. The purpose of this research is the development of a salt resistance bentonite by mixing sepiolite and guar gum to overcome the weak points of bentonite to get high water resistance capacity and permeability coefficient below $1{\times}10^{-7}cm/s$ under salt water condition. After having performed drying shrinkage cracking test, swelling index test, compaction test, and hydraulic conductivity test we confirmed the optimal mixing ratio of materials and evaluated the performance of materials.

Stress Corrosion Cracking Behavior of Alloy 690 in Crevice Environment (Pb + S + Cl) in a Steam Generator Tube (증기발생기 전열관 틈새복합환경(Pb+S+Cl)에서 Alloy 690의 응력부식균열거동)

  • Shin, Jung-Ho;Lim, Sang-Yeop;Kim, Dong-Jin
    • Corrosion Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • The secondary coolant of a nuclear power plant has small amounts of various impurities (S, Pb, and Cl, etc.) introduced during the initial construction, maintenance, and normal operation. While the concentration of impurities in the feed water is very low, the flow of the cooling water is restricted, so impurities can accumulate on the Top of Tubesheet (TTS). This environment is chemically very complicated and has a very wide range of pH from acidic to alkaline. In this study, the characteristics of the oxide and the mechanism of stress corrosion cracking (SCC) are investigated for Alloy 690 TT in alkaline solution containing Pb, Cl, and S. Reverse U-bend (RUB) specimens were used to evaluate the SCC resistance. The test solution comprises 3m NaCl + 500ppm Pb + 0.31m $Na_2SO_4$ + 0.45m NaOH. Experimental results show that Alloy 690 TT of the crevice environment containing Pb, S, and Cl has significant cracks, indicating that Alloy 690 is vulnerable to stress corrosion cracking under this environment.

The Properties of Dielectric Breakdown and Thermal Stresses below 22.9[kV] Class XLPE Power Cable (22.9[kV]이하 XLPE 전력케이블의 열 충격 시험 및 절연파괴 특성)

  • Kim, Young-Seok;Shong, Kil-Mok;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.54-60
    • /
    • 2008
  • It is impossible to database(DB) the patterns of power cable events and cause analysis of faulted cable because the product liability(PL) law have been enforced in Korea, since 2002. In additions, simulation and pattern of power cable events are needed for DB system under accelerated deterioration. In this paper, we tested for resistance to cracking of cable below the 22.9[kV] class due to thermal stresses. This method of exam is following IEC 60811-3-1(Common test methods for insulating and sheathing materials of electric cables). From the results, The 22.9[kV] class A power cable was discolored on the surface and significantly reduced in the longitudinal direction. As the thermal weight properties of A power cable was definitely varied, we are able to guess the problem of manufacture. If the cable was defect by the manufacture, the victims would be able to claim for damage in the PL system.

Change of Mechanical Properties of Clad Steel According to the Welding Process Design (용접 공정 디자인에 따른 클래드강의 기계적 성질 변화)

  • Lee, Jung-Hyun;Park, Jaw-Won
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.372-379
    • /
    • 2013
  • In this study, we investigated the traits of the clad metals used in hot-rolled clad steel plates. We examined the sensitization and mechanical properties of STS 316 steel plate and carbon steel (A516) under the specific circumstances of post heat treatment and whether a weld was multilayered and thick or repeated because of repairs. The test conditions were as follows. The clad steel plates were butt-welded using FCAW/SAW, and the heat treatment was conducted at $625^{\circ}C$, for 80, 160, 320, 640, or 1280 min. The change in the corrosion resistance was evaluated in these specimens. In the case of the carbon steel (A516), as the heat treatment time increased, the annealing effect caused the tensile strength to decrease. The micro- hardness gradually increased and then decreased after 640 min. The elongation and contraction of the area increased gradually. An oxalic acid etch test and EPR test on STS316, a clad metal, showed a STEP structure and no sensitization. From the test results for the multi-layered and repair welds, it could be concluded that there is no effect on the corrosion resistance of clad metals. In summary, the purpose of this study was to suggest some considerations when developing on-site techniques and evaluate the sensitization of stainless steels.

State of Art Report on the Trends of Welding Consumable Development for Higher Strength Steels

  • Kim, H. J.
    • International Journal of Korean Welding Society
    • /
    • v.2 no.1
    • /
    • pp.52-56
    • /
    • 2002
  • This report was prepared to give informations on a proper way to develop new consumables for the steels with improved weldability. Traditionally, hydrogen control has been pursued mainly for suppressing the HICC in HAZ but it also has contributed to HICC in weld metal. Facing the limitations in reducing the hydrogen content, it is now important to consider the microstructural control approach in order to improve the HICC resistance of weld metal . It has been shown that changes in alloy design, and hence composition and microstructure, was quite effective in producing high strength weld metal with improved resistance to cold cracking. Besides the economic test methods for evaluating susceptibility of multipass weld metal is essential to promote the development of welding consumables.

  • PDF

Evaluation of Underwater-Curing Coating Materials

  • Nah, Hwan-Seon;Kim, Kang-Seok;Kim, Kang-Sik;Lee, Chul-Woo;Baker, Randy
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.68-73
    • /
    • 2009
  • An evaluation of underwater - repair coating materials was based on the premise that defective areas of the existent epoxy coating such as blistering and cracking will be repaired on spot under submerged condition. Tests include the clarification as to whether they are compatible between as-built coating and new repair coating on each concrete specimen. Candidate coating materials for repair were tested in a laboratory to scrutinize their suitability to perform the needed function satisfactorily. The qualification tests performed are as a minimum as follows: Integrated radiation tolerance test, chemical resistance test (submerged condition in deionized water), hardness test and adhesion test of the repair materials. The proper repair coating materials were selected and approved from this test results.