• Title/Summary/Keyword: Test and installation standards

Search Result 71, Processing Time 0.024 seconds

Installation and Shipboard Tests of the Ballast Water Treatment System Electro-Cleen (Electro-Cleen 선박평형수 처리장치의 실선 설치 및 선상시험)

  • Kim, Eun-Chan;Cho, Jin-Suk;Park, Yong-Seok;Lee, Jong-Wook
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.3
    • /
    • pp.209-216
    • /
    • 2009
  • IMO has established International Convention for the Control and Management of Ships' Ballast Water and Sediment 2004 in February 2004 in order to prevent transfer of aquatic organisms through ballast water. According to the Convention, Each countries are preparing ratification and legislation process and encouraging the development of treatment system to satisfy the performance standard in the Convention. This Electro-$Cleen^{TM}$ treatment system was granted IMO basic approval in March 2006, and final approval in October 2008. The Type Approval Certificate was issued in December 2008 by the Government of Republic of Korea. This paper considers the matter of principle mechanism, overview of the system, installation on shipboard and shipboard test results for the Electro-$Cleen^{TM}$. Shipboard tests with the 8300 GT M/V Yokohama and 27,000 DWT M/V Greenwing have already been conducted. These tests confirmed that the Electro-$Cleen^{TM}$ system satisfies all of the IMO standards and is suitable for installation in new and existing ships.

  • PDF

Performance Evaluation of Lane Keeping Assistance System (도로주행환경을 고려한 차선유지지원장치 성능 평가)

  • Woo, Hyungu;Yong, Boojoong;Kim, Kyungjin
    • Journal of Auto-vehicle Safety Association
    • /
    • v.6 no.2
    • /
    • pp.29-35
    • /
    • 2014
  • Lane Keeping Assistance System(LKAS) is a kind of Advanced Driver Assistance Systems(ADAS) which are developed to automate/ adapt/ enhance vehicle systems for safety and better driving. The main system function of LKAS is to support the driver in keeping the vehicle within the current lane. LKAS acquires information on the position of the vehicle within the lane and, when required, sends commands to actuators to influence the lateral movement of the vehicle. Recently, the vehicles equipped with LKAS are commercially available in a few vehicle-advanced countries and the installation of LKAS increases for safety enhancement. The test procedures for LKAS evaluations are being discussed and developed in international committees such as ISO(the International Organization for Standardization). In Korea, the evaluations of LKAS for vehicle safety are planned to be introduced in 2016 KNCAP(Korean New Car Assessment Program). Therefore, the test procedures of LKAS suitable for domestic road and traffic conditions, which accommodate international standards, should be developed. In this paper, some bullet points of the test procedures for LKAS are discussed by extensive researches of previous documents and reports, which are released in public in regard to lateral test procedures including LKAS and Lane Departure Warning System(LDWS). Later, it can be helpful to make a draft considering domestic traffic situations for test procedures of LKAS.

Analysis between Computer Simulation and Real-car Crash Test of Energy Absorption Facilities for Various Road Environments (다양한 환경에 적용 가능한 충격흡수시설의 시뮬레이션 분석 및 실물충돌시험 결과 분석)

  • No, Min Hyung;Park, Jea Hong;Seo, Chang Won;Sung, Jung Gon;Yun, Duk Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.399-407
    • /
    • 2022
  • Energy absorption facilities installed on roads should follow the performance standards of the real-car crash test of 'Installation and Maintenance Guidelines for Roadside Safety Facilities'. However, due to different installation conditions, such as differing structure widths on roads, some energy absorption facilities do not provide adequate performance. In order to apply varied environments on roads, an energy absorption structure was designed in this study with 150 mm height and four layers of W-shape guardrail at 200 mm intervals, and the performance was verified using LS-DYNA computer simulation. Through a real-car crash test, the performance of the facility designed by LS-DYNA was tested and was found to meet the performance of the CC2 category for crash cushions. The conclusion of the comparison demonstrates that the simulation and the real-car crash tests are both significant.

The Study on Antenna Performancet Test for Surion Radio Installation and Optimal Positioning (수리온 통신 안테나 장착 및 최적위치 선정을 위한 안테나 성능시험에 관한 연구)

  • No, Sangwan;Lee, Soonyoung;Kim, Minsoo
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.5
    • /
    • pp.122-129
    • /
    • 2020
  • Surion is required to install radios (U/VHF-AM, VHF-FM) capable of omni-directional communication. Therefore, this paper demonstrates the antenna performance test for the installation of the Surion communication antenna and the selection of optimal location. A simulation pattern analysis was performed employing the antenna, and a coupling test was performed by creating a new evaluation criterion. In addition, the results of the pattern flight test conducted at the previously suggested 1:20 turn and separation distance ratio were observed to be normal. However, the occurrence of voice cutoff was noted in the long-distance flight test. Therefore, in this paper, 1:300 (15 NM) is proposed as a new optimal ratio for predicting the long-distance flight test results in advance. Finally, the effectiveness of the proposed evaluation criteria was verified through long-distance flight tests. Consequently, it is expected to reduce the development schedule and cost by reducing the trial and error of the performance test for the Surion model. Also, the results of this study are expected to be used as standards for the installation of communication antenna and quality tests for other helicopters.

A Study on the Assignment of the Vibration Classes to the Power Transformers in Operation (154[kV])

  • Kim, Young-Dal
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.52-60
    • /
    • 2009
  • High reliability is essential for power transformers, and their fault causes are reportedly more related to mechanical causes than electrical ones. The transformer soundness judgment currently depends only on the electrical insulation characteristic and the chemical test of the insulation oil, so that there are few fundamental measures against the frequent mechanical damages and failures in transformers. The mechanical soundness judgment techniques are conducted through processes that include structural analysis and vibration resistance treatment during the manufacturing process of each manufacturer, but the vibration is not tested during the design, manufacturing, and operating processes since there are no detailed technical standards and procedures on the vibration problem, which are important in terms of maintenance. Therefore, in this study, vibration phenomena were measured from the 32 power transformers in operation in the substations under the Daejeon Power Transmission District Office of the Korean Electric Power Corporation (KEPCO). The vibration was measured at 24 sections ($6{\times}4$) on one side, and only the maximum values were selected from the measured vibration values. This was because the maximum vibration values more significantly affect the soundness of the transformer than the average vibration values. The vibration classes were given considering the maximum vibration based on ISO 10016-1 (2001).

Current Issues on the Oil UST Management and Future Directions for the Prevention of the Subsurface Contamination (현행 주유소 지하유류저장시설 관리의 문제점과 토양${\cdot}$지하수 오염 방지를 위한 개선방안 연구)

  • Kim Meejeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.4
    • /
    • pp.62-73
    • /
    • 2004
  • The current status and problems of UST management in gas stations were reviewed, and suggestions were made for possible improvement of UST management. Regulations and programs relevant through the whole life cycle of the UST, such as construction, installation, operation, and disclosure are insufficient to prevent oil release. The UST requirements are less stringent compared to those of the U.S. and EU members. Current soil test does not seem to be practically effective in detecting soil contamination caused by oil release. The potential for subsurface contamination due to oil release from the UST is estimated from available data other than soil test results. Much higher following future directions and suggestions are made to improve current unsatisfactory UST management: Firstly, increasing the UST requirements - establishing more stringent standards for new UST facilities, and adding new regulatory requirements for existing UST facilities; secondly, replacing current soil test with the tank and piping tests; thirdly, reinforcing programs for supervising the tank construction and installation; fourthly, constructing a system in which independent gas stations can properly manage the USTs; and lastly, educating UST owners and operators, and constructing DB of UST facilities.

Evaluation of S-100 ECDIS Based on S-10X Digital Maritime Safety Information

  • CHOI, HyunSoo;OH, SeWoong;KANG, DongWoo;Yoon, MyongO
    • Journal of Navigation and Port Research
    • /
    • v.44 no.5
    • /
    • pp.375-381
    • /
    • 2020
  • The IMO has established a regulation for the ECDIS installation on ships based on the IHO S-57 standards. The ECDIS supports sailors in achieving a safe voyage by using ENCs and monitoring the information of their ship. However, the S-57 standards were developed as edition 3.1 and prohibited revision for more than 20 years. So, the IHO developed a new standard as S-100 into the hydrography and maritime field instead of updating the S-57 to edition 4.0. In this study, the new S-100 ECDIS was developed and verified with ENCs and the digital maritime safety information by using a ship steering simulator and by conducting an on-board sea-trial test. It evaluated the impact on ship operations if the next-generation navigation support system is introduced. Based on this research, the S-100 ECDIS will generate improvements such as safe voyages by providing various of real-time safety information and up-to-date data to ship and sailors.

A Study on Development of Crash Cushion (도로 충격흡수시설의 개발에 관한 연구)

  • Choi, Ki-Jun;Kwon, Yong-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.7-12
    • /
    • 2011
  • The crash cushion has drawn a great attention because of its versatility, efficiency and simplicity in reducing the mortality and damages from traffic accidents. However, the existing cushion systems are high priced or have limited functions. The purpose of the study was to devise an improved crash cushion which can offer higher safety compared to the available ones at present. In addition, the conformity of the cushion with the facility standards was assessed through computer simulation for collision with vehicles. The novel cushion system adopts the used tires as shock absorber, which can not only secure cushioning effect but also reduce the production cost. Moreover, it is highly durable and easy to maintain and repair the damaged parts. According to the simulation using BARRIER VII program, the novel cushion system showed PHD of 17.4 g and 10.1 g for a frontal collision and a side collision, respectively. Based on the results, it could be concluded that the novel cushion system met the test standards in the guideline for road safety facility installation and management.

Field Test for Absorption Energy and Displacement of Rockfall Protection Net (낙석방지울타리 망의 변위량 및 성능검증을 위한 실물낙석시험)

  • Seo, JinHyuk;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.12
    • /
    • pp.17-21
    • /
    • 2020
  • Over 60% of South Korea's land consists of mountainous topography, and recently, due to earthquakes, localized heavy rains and road development, the risks of rockfalls are getting higher. As of now, rockfall prevention facilities are being constructed in 70% of Korean roads cut slope and rockfall protections account for about 20% of them. Rockfall protection's supporting capacity is defined by combining performance of wire mesh, pillars and wire ropes. For the existing constructed rockfall protection, standards of pillars that can absorb 48~61 kJ amount of energy, wire ropes and wire mesh are presented in Guidelines for the installation and management of traffic safety facilities, Rockfall prevention facilities by Ministry of Land, Transport and Maritime Affairs (2008). However, each factor's correlation of absorption energy is not presented so it is uncertain. This study will conduct vertical drop test and identify adequacy of rockfall protection net of displacement quantity calculation factor which is delta and evaluate rockfall protection net's absorbable energy through standards of overseas performance evaluation criteria.

A Study on the Evaluation of Field Installation Damage and Strength Reduction Factor of Geogrid for Reinforced Retaining Wall (보강토 옹벽용 지오그리드의 현장 내시공성 및 강도 감소계수 평가에 관한 연구)

  • Park, Juhwan;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.7
    • /
    • pp.5-12
    • /
    • 2012
  • Recently the installation of reinforced earth retaining walls in the domestic construction site has increased, surpassing conventional RC walls. These reinforced walls have various types depending on the reinforcing material, installation method and the form of face panel. However, there are difficulties in design and construction management due to the unproved safety of construction method. In case of reinforcing materials, despite the fact that they come in all different sizes and types produced by small businesses or partially imported with cheap price and low quality, no proper standards for designing the walls have been suggested. In order to apply reinforced retaining wall system to broad cases and design the walls effectively considering site conditions, specific design and construction guidelines for efficient construction management are needed. In conclusion, this study verified that reduction factors can be greatly affected by grain sizes and stiffness of backfill materials and granularity range, therefore in case of relatively large construction site, it is required to redesign the reinforced retaining wall by evaluating site installation resistance test, applying respective reduction factors to each backfill material and select the right geogrid depending on the usage of retaining wall so as to enhance the safety of reinforced earth retaining walls with efficiency.