• Title/Summary/Keyword: Test Unit

Search Result 3,993, Processing Time 0.031 seconds

Characteristic Test of High Force Linear Motor Feed Unit for High Speed Machine Tool (고속가공기용 고추력 리니어모터 이송계의 특성 평가)

  • 송창규;황주호;박천홍;이후상;정재한
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.977-981
    • /
    • 2000
  • Direct drive linear motors have large potential for use as high speed machine tool feed units since they can increase machining rates and improve servo accuracy by eliminating gear related machining problems. So, in this paper, characteristic of 2-axis linear motor feed unit are studied and control gain are adjusted considering positioning, velocity, acceleration and static stiffness. We confirm linear motor feed unit are affected value of control gain sensitively, because drive directly. From the experiment, this feed unit has l${\mu}{\textrm}{m}$ micro step resolution, 5.7${\mu}{\textrm}{m}$ positioning accuracy and under 60${\mu}{\textrm}{m}$ circularity.

  • PDF

An Experimental Study on the Rule Based Fault Detection and Diagnosis System for a Constant Air Volume Air Handling Unit (룰 베이스를 이용한 정풍량 공조기 고장 검출 및 진단 시스템의 실험적 연구)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.872-880
    • /
    • 2004
  • The fault detection and diagnosis technology may be applied in order to decrease the energy consumption and the maintenance cost of the air-conditioning system. In this study, an air handling unit fault test apparatus was built and fault diagnosis algorithms were applied to diagnose various faults of an air handling unit. Test results showed the good diagnosis for applied faults. Therefore, these algorithms may be effectively used to develope the real time fault detection and diagnosis system for the air handling unit.

Testing for a unit root in an AR(p) signal observed with MA(q) noise when the MA parameters are unknown

  • Jeong, Dong-bin;Sahadeb Sarkar
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.2
    • /
    • pp.165-187
    • /
    • 1998
  • Shin and Sarkar (1993, 1994) studied the problem of testing for a unit root in an AR(p) signal observed with MA(q) noise when the MA parameters are known. In this paper we consider the case when the MA parameters are unknown and to be estimated. Test statistics are defined using unit root parameter estimates based on three different estimation methods of Hannan and Rissanen (1982), Kohn (1979) and Shin and Sarkar (1995). An AR(p) process contaminated by MA(q) noise is a .estricted ARMA model, for which Shin and Sarkar (1995) derived an easy-to-compute Newton- Raphson estimator The two-stage estimation p.ocedu.e of Hannan and Rissanen (1982) is used to compute initial parameter estimates in implementing the iterative estimation methods of both Shin and Sarkar (1995) and Kohn (1979). In a simulation study we compare the relative performance of these unit root tests with respect to both size and power for p=q=1.

  • PDF

A Study on Characteristics of the Unit Skin Friction Using the Wall Roughness in the Soft Rock (연암부 벽면거칠기를 이용한 단위주면마찰력 특성에 관한 연구)

  • Hong, Seok-Woo;Hwang, Geun-Bae
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.12
    • /
    • pp.7-13
    • /
    • 2019
  • In the case of the drilled shaft, one of the methods for calculating unit skin friction stress of rock socket parts is to measure the roughness of the excavated face. This method is to estimate the unit skin frictional resistance using a device which measures the roughness shape of the excavated face in the excavation step. In this study, the roughness shapes of the face of the rock socket part in the drilled shaft were measured directly in the perforated hole and the results are used to identify the characteristics of the unit skin friction of the bedrock. In addition, the static load test and the load transfer test were performed on the same pile to verify the result of the roughness test.

Experimental Study on Compaction Effect of Hydraulic Fill Soils (실내실험을 통한 수중 매립토의 다짐효과 분석)

  • Lee, Haeng-Woo;Chang, Pyoung-Wuck;Chang, Woong-Hee;Bong, Tae-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.301-310
    • /
    • 2006
  • A series of laboratory tests was carried out for analyzing compaction characteristics of hydraulic fill soils(or hydraulically filled soils). Hydraulic fill soils were settled down by the weight of soil particle itself in water and consolidated by the extraction of water from the soil structures. Water content and dry unit weight were observed as the depth of sedimentation and consolidation soil. It was found from the result that the optimum water content $(W_{cpt})$ of the maximum unit weight$(\gamma_{dmax})$ is higher than that of laboratory compaction test(KS F 2312 A method). It was due to difference in compaction energy and compaction effect between two methods. And the maximum dry unit of hydraulic fill soil is smaller than that of laboratory compaction test. Especially in terms of compaction effect, the maximum relative compaction degrees$(R_{cmax})$ of Seamangum dredged sand, river sand and mixed sand, half and half of dredged and river sands, were 85%, 91% and 86%, respectively. It means that the compaction effect can be $85\sim91%$ of the maximum unit weight in laboratory compaction test.

  • PDF

Effects of Radiation Safety Management Education with the Use of a Booklet for Intensive Care Unit Nurses (중환자실 간호사를 대상으로 소책자를 활용한 방사선 안전관리 교육의 효과)

  • Lee, Jeong Eun;Kim, Sang Hee
    • Journal of Korean Critical Care Nursing
    • /
    • v.10 no.2
    • /
    • pp.1-13
    • /
    • 2017
  • Purpose: This study investigated the effects that the use of a booklet for intensive care unit nurses had on radiation safety management education (knowledge about and behaviors in radiation safety management, and awareness of anxiety caused by radiation hazards). Methods: A randomized control group pretest-posttest design was used. A booklet about radiation safety management developed by the authors was used as educational material. Participants (N=42) were intensive care unit nurses of P hospital in B city. Training was provided to the experimental group (N=21). Knowledge about and behaviors in radiation safety management and awareness of anxiety caused by radiation hazards were measured by questionnaires before and after the intervention. Data was analyzed by an $X^2$-test, non-paired t-test, and paired t-test. Results: There was a significant difference between groups in knowledge of (t=-14.932, p<.001) and behaviors in (t=-8.297, p<.001) radiation safety management and awareness of anxiety caused by radiation hazards (t=9.378, p<.001). Conclusion: The levels of knowledge about and behaviors in radiation safety management and awareness of anxiety generated by radiation hazards of intensive care unit nurses increased after receiving one session of radiation safety management education using the booklet. Therefore, providing radiation safety management training is suggested as an effective strategy for improving radiation safety management.

  • PDF

Development and Evaluation of a Nursing Handoff Protocol for Intensive Care Units (중환자실 간호 인수인계 프로토콜의 개발 및 평가)

  • Cho, Young Shin;Kwon, Sun Ju;Yun, Mi Young;Lee, Mi Hwa;An, So Hee;Kong, Yu Jeong
    • Journal of Korean Critical Care Nursing
    • /
    • v.9 no.2
    • /
    • pp.1-12
    • /
    • 2016
  • Purpose: This study aimed to develop a nursing handoff protocol for intensive care units and test its relevance. Methods: This is a methodological research to develop a protocol. A preliminary protocol was developed by composing items and testing content validity through literature review and experts' review. We revised and complemented the preliminary protocol following practical relevance assessment of 38 intensive care unit nurses at a university hospital to test content validity and to assess practical relevance of the final protocol. Results: On the basis of the content validity test for the final protocol, 40 items were adopted. The scores for the practical relevance of the final protocol increased significantly for items such as accuracy of handoff, reduction of handoff-related errors, convenience in using the protocol, reduction in handoff time, and simplification of handoff. Conclusions: The nursing handoff protocol for intensive care units in this study is expected to improve nursing performance with a standardized handoff in intensive care units, promote patient safety, and improve communication among the medical staff.

  • PDF

Correlation between Compressive Strength and Unit Weight of Lightweight Foamed Controlled Low Strength Material (CLSM) Using Coal Ash (석탄회를 활용한 경량기포 CLSM의 압축강도와 단위중량의 상관관계)

  • Lee, Jong-Hwi;Lee, Hye-Jin;Chun, Byung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.1
    • /
    • pp.39-47
    • /
    • 2013
  • With the increase in the application of CLSM using coal ash, we performed a basic research on CLSM material, laying focus on the correlation between compressive strength and unit weight of lightweight foamed CLSM. The unconfined compression strength is a criterion for the judgment of the possibility of re-excavation and an important factor determining the economy, efficiency, and excavation character. However, to know the quantitative compression strength value takes a certain amount of time, because the applicability of unconfined compression strength of CLSM is judged by the standard of 28days. Therefore, in this study the relation between compressive strength and unit weight (foam slurry unit weight, apparent unit weight) is analyzed focusing on lightweight foamed CLSM. We also suggested a formula which can easily predict the 28-day compressive strength only using unit weight value without the need to cure the slurry for 28 days.

A Study on the Water Quality Changes of TMDL Unit Watershed in Guem River Basin Using a Nonparametric Trend Analysis (비모수 경향분석법 적용을 통한 금강수계 총량관리 단위유역의 수질변화 연구)

  • Kim, Eunjung;Kim, Yongseok;Rhew, Doughee;Ryu, Jichul;Park, Baekyung
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.2
    • /
    • pp.148-158
    • /
    • 2014
  • In order to assess the effect of TMDLs management and improve that in the future, it is necessary to analyze long-term changes in water quality during management period. Therefore, long term trend analysis of BOD was performed on thirty monitoring stations in Geum River TMDL unit watersheds. Nonparametric trend analysis method was used for analysis as the water quality data are generally not in normal distribution. The monthly median values of BOD during 2004~2010 were analyzed by Seasonal Mann-Kendall test and LOWESS(LOcally WEighted Scatter plot Smoother). And the effect of Total Maximum Daily Loads(TMDLs) management on water quality changes at each unit watershed was analyzed with the result of trend analysis. The Seasonal Mann-Kendall test results showed that BOD concentrations had the downward trend at 10 unit watersheds, upward trend at 4 unit watersheds and no significant trend at 16 unit watersheds. And the LOWESS analysis showed that BOD concentration began to decrease after mid-2009 at almost all of unit watersheds having no trend in implementation plan watershed. It was estimated that TMDLs improved water quality in Geum River water system and the improvement of water quality was made mainly in implementation plan unit watershed and tributaries.

Marginal and internal discrepancy of 3-unit fixed dental prostheses fabricated by subtractive and additive manufacturing (절삭 및 적층 가공법으로 제작된 3본 고정성 국소의치의 변연 및 내면 적합도에 관한 연구)

  • Choi, Jae-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.7-13
    • /
    • 2020
  • Purpose: This study was to evaluate marginal and internal discrepancy of 3-unit fixed dental prostheses (FDP) fabricated by subtractive manufacturing and additive manufacturing. Materials and methods: 3-unit bridge abutments without the maxillary left second premolar were prepared (reference model) and the reference model scan data was obtained using an intraoral scanner. 3-unit fixed dental prostheses were fabricated in the following three ways: Milled 3-unit FDP (MIL), digital light processing (DLP) 3D printed 3-unit FDP (D3P), stereolithography apparatus (SLA) 3D printed 3-unit FDP (S3P). To evaluate the marginal/internal discrepancy and precision of the prosthesis, scan data were superimposed by the triple-scan protocol and the combinations calculator, respectively. Quantitative and qualitative analysis was performed using root mean square (RMS) value and color difference map in 3D analysis program (Geomagic control X). Statistical analysis was performed using the Kruskal-Wallis test (α=.05), MannWhitney U test and Bonferroni correction (α=.05/3=.017). Results: The marginal discrepancy of S3P group was superior to MIL and D3P groups, and MIL and D3P groups were similar. The D3P and S3P groups showed better internal discrepancy than the MIL group, and there was no significant difference between the D3P and S3P groups. The precision was excellent in the order of MIL, S3P, and D3P groups. Conclusion: Within the limitation of this study, the 3-unit fixed dental prostheses fabricated by additive manufacturing showed better marginal and internal discrepancy than the those of fabricated by subtractive manufacturing, but the precision was poor.