• Title/Summary/Keyword: Test Temperature

Search Result 10,040, Processing Time 0.034 seconds

A Study on the Strain-Rate Sensitivity According to the Temperature for Steel Sheets of an Auto-Body (차체용 강판의 온도에 따른 변형률속도 민감도 연구)

  • Lee, H.J.;Song, J.H.;Cho, S.S.;Park, S.H.;Huh, H.
    • Transactions of Materials Processing
    • /
    • v.15 no.2 s.83
    • /
    • pp.132-137
    • /
    • 2006
  • This paper is concerned with the thermo-mechanical behavior including temperature dependent strain-rate sensitivity of steel sheet for an auto-body. In order to identify the temperature dependent strain-rate sensitivity of SPRC35R and SPRC45E, uniaxial tension tests are performed with the variation of the strain-rates from 0.001 /sec to 200 /sec at environmental temperatures varied from $-40^{\circ}C\;to\;200^{\circ}C$. The thermo-mechanical response at the quasi-static state is obtained with the static tensile test and at the intermediate strain-rate is from the high speed tensile test. Experimental results show that the strain-rate sensitivity increases at low temperature. It represents that as the strain-rate increases, the variation of flow stress becomes sensitive on the temperature. The results indicate that the flow stress of SPRC35R is more dependent on the changes of strain-rate and temperature than those of SPRC45E.

Measurement of the Moderator Temperature Coefficient of Reactivity for Pressurized Water Reactors

  • Yu, Sung-Sik;Kim, Se-Chang;Na, Young-Whan;Kim, H. S.;J. Y. Doo;Kim, D. K.;S. W. Long
    • Nuclear Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.488-499
    • /
    • 1997
  • The measurements of the moderator temperature coefficient (MTC) are performed to demonstrate that the calculational model produces results that are consistent with the measurements. Since negative MTC is also a technical specification value that may limit the cycle length, it is important to measure it as accurately as possible. In this report, preferred choice of test method depending on the time in cycle, best power indication and temperature definition in MTC calculation were determined based on the MTC test results taken during initial startup testing and at 2/3 cycle burnup in the Yonggwang nuclear power plant. The results show that the ratio and rodded methods provided good agreement with the predictions during initial startup testing. However, near end-of-cycle the depletion method gives better results, and so is suggested to be used in the MTC measurements at 2/3 cycle burnup. The use of primary Delta T power as a power indicator in the MTC calculations is highly advisable since it responds with good consistent results very quickly to changes unlike secondary calorimetric power. For the appropriate temperature definitions used in the MTC calculations, it is considered that the arithmetic average temperature measured simply by inlet and outlet thermocouples is preferred. Although volumetric average temperature provides better results, the improvement is not sufficient to compensate for the simplicity of calculations by arithmetic average temperature.

  • PDF

Sn58Bi Solder Interconnection for Low-Temperature Flex-on-Flex Bonding

  • Lee, Haksun;Choi, Kwang-Seong;Eom, Yong-Sung;Bae, Hyun-Cheol;Lee, Jin Ho
    • ETRI Journal
    • /
    • v.38 no.6
    • /
    • pp.1163-1171
    • /
    • 2016
  • Integration technologies involving flexible substrates are receiving significant attention owing the appearance of new products regarding wearable and Internet of Things technologies. There has been a continuous demand from the industry for a reliable bonding method applicable to a low-temperature process and flexible substrates. Up to now, however, an anisotropic conductive film (ACF) has been predominantly used in applications involving flexible substrates; we therefore suggest low-temperature lead-free soldering and bonding processes as a possible alternative for flex-on-flex applications. Test vehicles were designed on polyimide flexible substrates (FPCBs) to measure the contact resistances. Solder bumping was carried out using a solder-on-pad process with Solder Bump Maker based on Sn58Bi for low-temperature applications. In addition, thermocompression bonding of FPCBs was successfully demonstrated within the temperature of $150^{\circ}C$ using a newly developed fluxing underfill material with fluxing and curing capabilities at low temperature. The same FPCBs were bonded using commercially available ACFs in order to compare the joint properties with those of a joint formed using solder and an underfill. Both of the interconnections formed with Sn58Bi and ACF were examined through a contact resistance measurement, an $85^{\circ}C$ and 85% reliability test, and an SEM cross-sectional analysis.

Analysis on the performance characteristics of a variable-speed, roller-type vane compressor operating at low evaporating temperature (낮은 증발온도에서 운전되는 가변속 롤러형 베인 압축기의 성능특성에 관한 분석)

  • 김봉훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.193-204
    • /
    • 1999
  • Performance of a variable-speed, roller-type vane compressor was evaluated at low evaporating temperature. First, an experimental investigation was conducted to examine the performance variation as functions of both outdoor temperature and rotating speed. For this purpose, a typical heat pump was implemented as a test apparatus to measure mass flow rate and power input. Secondly, computational investigations corresponding to the heat pump test conditions were performed to predict compressor performance using ORNL Map-Based compressor model. Results obtained from the heat-pump experiments showed that both mass flow rate and power consumption were sensitively dependent on both evaporating temperature and compressor speed as was predicted from the computational results. From the comparisons of both experimental and computational results, it was well recognized that the ORNL model was subjected to larger error in the accuracy of prediction as outdoor temperature decreased. When the outdoor temperature was above $-5^{\cire}C$, errors of predicted values corresponding to both mass flow rate and power consumption were estimated as $\pm$10% and $\pm$ 15%, respectively. Finally, it is suggested that the ORNL model needs to be re-evaluated if compressor map data tested below $-5^{\cire}C$(in evaporating temperature) are available.

  • PDF

Effects of Forced Air Warming on Body Temperature, Shivering and Pain in Laparoscopic Cholecystectomy Patients (공기가온요법이 복강경 담낭절제술 환자의 체온, 전율 및 통증에 미치는 효과)

  • Park, Sung Joo;Kim, Sook Young
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.22 no.3
    • /
    • pp.287-296
    • /
    • 2015
  • Purpose: The purpose of this study was to examine the effects of forced air warming on intraoperative and postoperative body temperature, postoperative shivering and pain in patients undergoing laparoscopic cholecystectomy. Methods: A quasi-experimental design with nonequivalent control group was utilized. Fifty eight patients scheduled for laparoscopic cholecystectomy were recruited and assigned to the experimental group (n=29) or control group (n=29). For the experimental group, forced air warming was applied from right after induction and up to one hour after surgery. Body temperature, shivering score and pain score were measured in both groups at 15 minute intervals. Data were collected from September, 2013 to April, 2014. Data were analyzed using t-test, Bonferroni test and repeated measures ANOVA. Results: The experimental group showed higher body temperature than the control group during surgery. After surgery the experimental group showed higher body temperature, lower shivering and less pain compared to the control group. Conclusion: Results show that forced air warming is effective in enhancing body temperature and reducing shivering and pain. Therefore, forced air warming is recommended as an operative nursing intervention.

Strength Evaluation and Life Prediction of the Multistage Degraded Materials (다단계 모의 열화재의 재료강도 평가와 수명예측)

  • 권재도;진영준;장순식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2271-2279
    • /
    • 1993
  • In the case of life prediction on the structures and machines after long service, it is natural to consider a degradation problems. Most of degradation data form practical structures are isolated data obtained at the time of periodical inspection or repair. From such data, it may be difficult to obtain the degradation curve available and necessary for life prediction. In this paper, for the purpose of obtaining a degradation curves, developed the simulate degradation method and fatigue test and Charpy impact test were conducted on the degraded, simulate degraded and recovered materials. Fatigue life prediction were conducted by using the relationship between fracture transition temperature (DBTT : vTrs) obtained from the Charpy impact test through the degradation process and fatigue crack growth constants of m and C obtained from the fatigue test.

Wear and Friction Characteristics of SiC Reinforced Aluminium 6061 Alloy Composites (SiC 보강 A16061 복합재료의 마멸 및 마찰특성에 관한 연구)

  • 권재도;안정주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2122-2132
    • /
    • 1995
  • There are some cases which require to grasp the abrasion resistance property in the fields of the high-technology to be required the high specific strength and modulus. In this study, wear test with the various test temperature and velocity were performed in the SiCw/A16061 composite and A16061 matrix using the wear test machine of the ring-on-disc type. As the results, the friction and wear properties by various test temperature and velocity were examined. The worn surface has observed by scanning electron microscope in order to examine the wear mechanism.

Study on the Accelerated Test Condition of Pneumatic Cylinder (공기압 실린더 가속시험 조건에 대한 연구)

  • Kang, Bo-Sik;Kim, Hyoung-Eui;Gobin, Remi
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1648-1651
    • /
    • 2007
  • The goal of this paper is to introduce two methods to determine a model for the accelerated factor equation for pneumatic cylinder according to the Black equation shape. The loads consist of working pressure and temperature and we adjust these two parameters to reduce the test time but keeping the true behavior of deterioration. The first part will introduce a method using accelerated factor coming from experimental results to determine the coefficient of the Black equation by the method of the least square theory. The second part will introduce another method based on various conditions of test with the assumption that the effect of temperature and the effect of pressure on the life of pneumatic cylinder are independent. In these two cases, the results are the unknown coefficients of the Black equation.

  • PDF

Development of Accelerated Life Test Method for UHF RFID Tags for Medicine Supply Management (의약품 유통 관리용으로 사용되는 UHF 대역 RFID Tag의 가속수명시험법 개발)

  • Yang, Il Young;Yu, Sang Woo;Park, Jung Won;Joe, Won-Seo
    • Journal of Applied Reliability
    • /
    • v.14 no.2
    • /
    • pp.93-96
    • /
    • 2014
  • RFID (Radio Frequency IDentification) system is recognition technology which can maintain various object's information. Reliability of RFID tags is the most important factor in RFID system. In this paper, we proposed ALT (Accelerated Life Test) method for UHF RFID tags. Temperature and humidity were adopted as stress factors and the accelerated life tests were conducted in three different conditions. We performed failure analysis for identifying failure mechanism and statistical analysis of test data. In the statistical analysis, we employed Inverse Power law for relationship between tag's life and stress. Through the statistical analysis, we proposed acceleration factor for several levels of temperature-humidity. The reliability qualification test plans were also designed for the tag's target reliability.

Linear Structural Analysis and Simple Tensile Test of Plastic Injection Molding Tensile Specimen (플라스틱 사출인장시편의 단순인장시험 및 선형구조해석)

  • Lee, D.M.;Han, B.K.;Lee, Sung-Hee
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.05a
    • /
    • pp.230-233
    • /
    • 2006
  • In this study, the effects of residual stress induced by plastic injection molding process on the tensile behavior of plastic tensile test specimen were investigated. To manufacture plastic tensile test specimens, an injection mold based on the international standard system was designed and made. Cavity pressure and temperature sensors were installed inside of the presented mold to monitor pressure and temperature values during the cycle of injection molding. Injection molding simulation was performed with the same condition of experiment and linear structural tensile analysis was also performed with the initial condition of the residual stress. It was shown that the residual stress induced by injection molding has an effect on the experiment of tensile test and linear structural tensile simulation.

  • PDF