• 제목/요약/키워드: Test Temperature

검색결과 10,026건 처리시간 0.038초

철도차량용 제동디스크의 온도 변화 측정 및 물성치 변화에 관한 연구(I) (A study on the Mechanical Properties of the Braking Disk due to the Temperature Change(I))

  • 김재훈
    • 한국철도학회논문집
    • /
    • 제8권3호
    • /
    • pp.222-227
    • /
    • 2005
  • This study investigates the change of the temperature and mechanical properties of the braking disk for the railway vehicle. The average temperature is measured about $100^{\circ}C$ and the maximum temperature is measured over $200^{\circ}C$ by non-contact sensor from Seoul to Chun-an. As a result of measuring, we determine the temperature of test(tensile and J-integral) at $20^{\circ}C,\;100^{\circ}C,\;200^{\circ}C$ and $300^{\circ}C$. In the test, the material values are decreased by the increasing of the temperature. But ratio of decreasing is the largest at $200^{\circ}C$, the tensile test value is decreased about $10\%$ and the J-integral test value is decreased $30\%$. The mechanical properties of this material are mostly changed at $200^{\circ}C$.

인코벨 690 증기발생기 세관의 고온 마모 거동 (High Temperature Wear Behavior of Inconel 690 Steam Generator tube)

  • 홍진기;김인섭;김형남;장기상
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.59-62
    • /
    • 2001
  • Flow induced vibration in steam generators has caused dynamic interactions between tubes and contacting materials resulting in fretting wear . Series of experiments have been performed to examine the wear properties of Inconel 690 steam generator tubes in various environmental conditions. For the present study, the test rig was designed to examine the fretting wear and rolling wear properties in high temperature(room temperature - 290。C) water. The test was performed at constant applied load and sliding distance to investigate the effect of test temperature on wear properties of the steam generator tube materials. To investigate the wear mechanism of material, the worn was observed using scanning electron microscopy. The weight loss increase at higher test temperature was caused by the decrease of water viscosity and the mechanical property change of tube material. The mechanical property changes of steam generator tube material, such as decrease of hardness or yield stress in the high temperature tests. From the SEM observation of worn surfaces, the severe wear scars were observed in specimens tested at the higher temperature.

  • PDF

내환경 온도시험의 촉진시간에 관한 연구 (A Study on the Promotion Time in Environmental Temperature Test)

  • 한철호;김경훈;김형의
    • 대한기계학회논문집A
    • /
    • 제35권3호
    • /
    • pp.325-331
    • /
    • 2011
  • 내환경 시험시 시험물체가 요구시험온도가 되게 온도시험조를 가열 또는 냉각하는 계단형 온도시험 프로파일에서 적정 촉진온도 유지시간을 예측하는 집중용량법에 의한 새로운 해석적 방법을 제안하였다. 해석은 주어진 온도시험조건에 대해 시험시간을 줄이고 에너지를 절약하는 촉진시간이 존재함을 보여주고 있다. 이론결과는 작업소재로 강을 사용한 몇 가지 실험결과와 비교적 잘 부합하고 있다. 제안된 적정촉진시간은 동일재료에 대해 시편의 질량/표면적비와 근사적으로 비례한다.

Evaluation of Fracture Strength and Material Degradation for Weldment of High Temperature Service Steel Using Advanced Small Punch Test

  • Lee, Dong-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제18권9호
    • /
    • pp.1604-1613
    • /
    • 2004
  • This paper presents an effective and reliable evaluation method for fracture strength and material degradation of the micro-structure of high temperature service steel weldment using advanced small punch (ASP) test developed from conventional small punch (CSP) test. For the purpose of the ASP test, a lower die with a minimized ${\Phi}$1.5 mm diameter loading ball and an optimized deformation guide hole of ${\Phi}$3 mm diameter were designed. The behaviors of fracture energy (E$\_$sp/), ductile-brittle transition temperature (DBTT) and material degradation from the ASP test showed a definite dependency on the micro-structure of weldment. Results obtained from ASP test were compared and reviewed with results from CSP test, Charpy impact test, and hardness test. The utility and reliability of the proposed ASP test were verified by investigating fracture strength, behavior of DBTT, and fracture location of each micro-structure of steel weldment for test specimen in ASP test. It was observed that the fracture toughness in the micro-structure of FL+CGHAZ and ICHAZ decreased remarkably with increasing aging time. From studies of all micro-structures, it was observed that FGHAZ microstructure has the most excellent fracture toughness, and it showed absence of material degradation.

XKT-1(수출형 KT-1) 항공기 열 환경시험에 관한 연구 (Study on Thermal Environmental Test for XKT-1 (KT-1 Export Version) Aircraft)

  • 김진석
    • 항공우주시스템공학회지
    • /
    • 제15권3호
    • /
    • pp.105-113
    • /
    • 2021
  • 본 논문은 MIL-STD-810 시험법 501(고온 시험법)과 시험법 502(저온 시험법)를 기반으로 XKT-1(수출형 KT-1) 항공기 고객의 운용 환경과 요구사항에 적합하도록 시험조건과 시험절차를 최적화하여 열 환경시험 프로파일을 제시하였다. 또한, 이렇게 최적화된 고온 및 저온시험 프로파일을 환경시험 종합평가 계획서에 반영하여 국방과학연구소의 기후환경 챔버에서 시험수행 하였다. 본 고온 및 저온 환경시험 프로파일로 XKT-1(수출형 KT-1) 항공기의 고온 및 저온 환경시험수행 결과, 고객 환경 요구사항을 만족하고 혹독한 열 환경에서 신뢰성 있음을 확인하였다. 특히 본 논문에서 제안된 고온 및 저온 환경시험절차와 프로파일은 더 혹독한 환경시험 조건의 수출형 항공기 환경시험에도 응용할 수 있다.

154kV 전력용 변압기의 온도분포에 관한 연구 (The Study on the Temperature Distribution for 154kV Power Transformers)

  • 우정욱;구교선;곽주식;김경탁;권동진
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.56-61
    • /
    • 2011
  • The temperature of power transformers is very important factor for power system operation in substation because load capacity and limited lifetime of power transformers are determined by winding temperature. Also, The temperature of power transformers varies with the structure, capacity, operation condition and manufacturers. Thus, it is necessary for temperature distribution to be exactly investigated because of efficient load management and prediction of limited lifetime. Nevertheless, there was no case of analysis as well as measurement of the temperature of power transformers. In this paper, we manufactured the 154kV standard power transformer for the test. And we measured the temperature by the heat run test and analyzed the temperature distribution of transformer.

디젤차량 연비시험에 있어 시험온도 및 냉각팬 조건이 미치는 영향분석에 관한 연구 (A Study on the Influence of Test Temperature & Cooling Fan Condition on the Fuel Test of Diesel Vehicle)

  • 김현진;김성우;임재혁;노경하;이정천;김기호;오상기
    • 동력기계공학회지
    • /
    • 제21권6호
    • /
    • pp.46-55
    • /
    • 2017
  • Due to the arise of natural disasters caused by global warming, consumers have more interest in the fuel efficiency of their vehicles, and fuel efficiency became an important factor in comparing vehicles. In this market situation, methods to measure fuel efficiency has become one of the main interests of vehicle related organizations and laboratories, and the current method to measure fuel efficiency is to follow the notification established by the ministry of trade, industry and energy, ministry of environment, and the ministry of land, infrastructure and transport. In this study, we analyze the influence of vehicle fuel efficiency according to test temperature and cooling fan condition which have the possibility to cause difference in fuel efficiency. The analysis results of the influence of the fuel efficiency according to the test temperature, the difference of the fuel efficiency of the test temperature ($21{\sim}29^{\circ}C$) within the allowable range of the notification showed a maximum difference of 2.9%. Therefore, it is necessary to consider the introduction of a test method that permits only the temperature change based on the reference point as the allowable range even in the test within the allowable range. The analysis of the influence of the fuel efficiency according to the cooling method showed no significant effect, and it seems reasonable to maintain the test method of the current notification.

내압력.온도센서를 갖는 표준 인장시편용 사출금형설계 및 성형 (Design of Injection Mold with Cavity Pressure/Temperature Sensors and Molding for Standard Tensile Test Specimen)

  • 이도명;한병기;이옥성;이성희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1416-1419
    • /
    • 2005
  • Design and manufacturing of plastic injection mold with cavity pressure/temperature sensors were performed in the present study for tensile test specimen. Standards of mold-base and tensile test specimen were used to design an injection molding system. Cavity pressure and temperature sensors were placed on the side of fixed platen of injection mold machine to prevent them from external impact damage. Injection molding experiments with variations of injection speed and melt temperature were performed and polycarbonate tensile specimens were prepared for the tensile test. It was shown that injection molding processing parameters can have effect on the mechanical properties of the plastic injection molded part.

  • PDF

ROSA/LSTF test and RELAP5 code analyses on PWR 1% vessel upper head small-break LOCA with accident management measure based on core exit temperature

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • 제50권8호
    • /
    • pp.1412-1420
    • /
    • 2018
  • An experiment was performed using the large-scale test facility (LSTF), which simulated a 1% vessel upper head small-break loss-of-coolant accident with an accident management (AM) measure under an assumption of total-failure of high-pressure injection (HPI) system in a pressurized water reactor (PWR). In the LSTF test, liquid level in the upper head affected break flow rate. Coolant was manually injected from the HPI system into cold legs as the AM measure when the maximum core exit temperature reached 623 K. The cladding surface temperature largely increased due to late and slow response of the core exit thermocouples. The AM measure was confirmed to be effective for the core cooling. The RELAP5/MOD3.3 code indicated insufficient prediction of primary coolant distribution. The author conducted uncertainty analysis for the LSTF test employing created phenomena identification and ranking table for each component. The author clarified that peak cladding temperature was largely dependent on the combination of multiple uncertain parameters within the defined uncertain ranges.

석영 가열램프의 열 유속 특성 파악을 통한 고온 구조시험의 열 하중 설계에 관한 연구 (A Study on Heat Flux Characteristics of Tubular Quartz Lamp for Thermal Load Design of High Temperature Structural Test)

  • 김준혁
    • 한국군사과학기술학회지
    • /
    • 제25권4호
    • /
    • pp.355-363
    • /
    • 2022
  • Development of supersonic flying vehicle is one of the most latest issue in modern military technology. Specifically, structural integrity of supersonic flying vehicle can be verified by high temperature structural test. High temperature structural test is required to consider thermal load caused by aerodynamic heating while applying structural load simultaneously. Tubular quartz lamps are generally used to generate thermal load by emitting infrared radiation. In this study, modified heat flux model of tubular quartz lamp is proposed based on existing model. Parameters of the proposed model are optimized upon measured heat flux in three dimensions. Finally, thermal load of plate specimen is designed by the heat flux model. In conclusion, it is possible to predict heat flux applied on plate specimen and desired thermal load of high temperature structural test can be obtained.