소형 펀치시험에 의한 강용접부의 파괴강도 평가에 관한 연구 2

  • 류대영;송기홍;정세희
    • Journal of Welding and Joining
    • /
    • 제7권4호
    • /
    • pp.56-67
    • /
    • 1989
  • In this study, the possibility of evaluating the peculiar fracture strength of weldment in high strength steels was investigated by means of a small punch(SP) test. In order to obtain the ductile-brittle transition temperature(DBTT) of SP energy by which the fracture strength of weldment in structural steels such as SS41 and SM53B steels had been evaluated in our preceding publication, the effects of notches and loading rates on SP energy were discussed. It was found that the correspondence of SP energy to critical COD at test temperature -196.deg. C showed a linear relation with some deviation. The empirical correlation with scatter band, Esp/(Esp)p = 1.67[.delta./(.delta./sub c//(.delta./sub c/)/sub p/]-0.55, was developed between the SP energy ratio and critical COD ratio of each weld structure compared with parent material at test temperature -196.deg. C. In addition, there did not appear to be a significant effect of test materials and specimen size etc. on the correlation.

  • PDF

반도체장비용 오링의 종합 신뢰성 평가기술에 관한 연구 (A Study on the Reliability Evaluation System for O-ring of Semiconductor Equipments)

  • 김동수;김광영;최병오;박화영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.613-617
    • /
    • 2001
  • The test items like as endurance, air leakage and oil endurance test is requested for reliability evaluation about O-ring which is a kind of core machinery accessories of semi-conduct manufacturing equipment. For verification of these, we design and manufactured a test system for endurance, air leakage and oil endurance of O-ring for semi-conduct manufacturing equipment, and also performed the test for two kinds of O-ring, as it were Viton and Kalretz. The characteristics of this test equipment consist in realization of the test conditions of semi-conduct manufacturing equipment and satisfying the test method. The test conditions are cut gas, vacuum grade, temperature and revolution numbers in the endurance test system, vacuum grade and temperature in the air leakage test system, temperature and time in the oil endurance test system. The separating test results for wearing which is an oil endurance test item, the wearing index of domestic produced Viton O-ring is higher than foreign product by 2%, wearing rate of Kalretz O-ring better than Viton O-ring by 17%, and particles existed in various place. The test result of air leakage which is measured through the RGA sensor used Helium, the vacuum grade was $10^-3$Torr. And the test result of oil endurance, the volume change rate was 7~15%. Hereafter, we intend to analysis the reliability test evaluation and to utilize for domestic manufacturing companies by establishing data base and developing reliability softwares.

  • PDF

가온요법을 받은 노인 수술 환자의 체온과 영향요인 (Factors Influencing Body Temperature in Elderly Surgical Patients)

  • 권미희;변영순
    • 기본간호학회지
    • /
    • 제20권2호
    • /
    • pp.108-117
    • /
    • 2013
  • Purpose: The purpose of this study was to identify the factors that affect body temperature in elderly operation patients using a warming method and to examine differences in post operative body temperature by characteristics of the patients. Methods: Data were collected from 200 patients, aged 65 years or more undergoing surgery with a warming method. The data were analyzed using descriptive statistics, t-test, ANOVA, Scheffe's test and multiple regression with the SPSS 18.0 Program. Results: The mean score for body temperature of elderly operation patients using a warming method after surgery was $36.1{\pm}0.6^{\circ}C$ including 74 patients with hypothermia and 126 patients with normal body temperature. The body temperature according to general characteristics differed by age and whether the surgery was emergency surgery or not. The body temperature according to surgery-related factors differed by anesthesia type, length of operation, anesthesia time, magnitude of surgical procedure, amount of fluid, transfusion requirements, and preoperative body temperature. Factors influencing body temperature were age, BMI, transfusion requirements and preoperative body temperature. Conclusion: The results indicate that age, BMI, transfusion requirements and preoperative body temperature significantly influenced on body temperature after surgery. Thus preoperative body temperature needs to be maintained through pre-warming as a nursing intervention.

외기온도 및 시험체 크기를 고려한 콘크리트의 간이-단열온도 상승시험에 관한 실험적 연구 (An Experimental Study on the Semi-Adiabatic Temperature Rise Test of Concrete Considering Outside Temperature and Specimen Size)

  • 온정권;김영선;문형재;남정수;김규용
    • 한국건축시공학회지
    • /
    • 제21권6호
    • /
    • pp.563-571
    • /
    • 2021
  • 최근 초고층 아파트 및 주상복합 건축물의 증가로 두께 3m이상의 메가급 매스콘크리트 부재의 설계가 다수 수행되고 있다. 초고층 주상복합 건축물은 기초부재 뿐만 아니라 특수한 구조형태로 전이 보 및 슬라브 등과 같은 매스콘크리트 시공이 증가하고 있어 매스콘크리트의 온도균열저감에 관한 연구가 수행되고 있다. 매스콘크리트의 온도균열을 검토하기 위해서는 콘크리트 열특성 검토가 중요하나 현장에서 단열온도상승 시험기를 활용하기는 어렵기 때문에 간이-단열온도상승시험을 주로 활용한다. 본 연구에서는 간이-단열온도상승시험에 의한 콘크리트 열특성 결과의 정밀도를 향상시키기 위해 열손실을 보정하기 위한 방안과 열손실 보정에 미치는 다양한 요인을 검토하여 제시하였다.

기초화장용 제품 중 크림과 로션제의 안정성 평가방법 (Stability Test for the Cream and Lotion Among the Cosmetic Foundations)

  • 조혜영;이석;백승희;최후균;이용복
    • Journal of Pharmaceutical Investigation
    • /
    • 제33권4호
    • /
    • pp.293-298
    • /
    • 2003
  • This study was attempted to develop the physicochemical ad morphological stability test methods for the cream and lotion formulations among the cosmetic foundations and to provide the guidance for the stability methods with respect to basic emulsions and creams. With these developed stability test methods, we can evaluate the expired date or life time of the available basic cosmetics, especially basic lotions ad creams. Also, the stability test methods established in this study can be used as a guideline to test physical and morphological stability of cosmetics in the future. Thus, we selected two types of basic cosmetics such as lotions and creams made by four different cosmetic companies ad applied them to the stability test methods depending on the temperature changes such as temperature cycling and freezing-thawing cycling test. After the temperature changes, the conductivity, turbidity, particle size, creaming ratio and pH changes of the creams and lotions were evaluated and morphological changes such as crystal formation, odor, color and feeling of the creams and lotions were also tested. As the results of the stability tests, all the tested creams and lotions except for one lotion were stable. Therefore, it may be concluded that these short-term accelerated stability tests as physical stability test depending on the temperature change study were suitable for the stability testing methods for the basic cosmetics and may be useful for the establishment of the guideline for the stability test of cosmetics.

지하처분연구시설(KURT)에서의 시추공 히터 시험 (Borehole Heater Test at KAERI Underground Research Tunnel)

  • 권상기;이창수;윤찬훈;전석원;조원진
    • 터널과지하공간
    • /
    • 제21권3호
    • /
    • pp.225-234
    • /
    • 2011
  • 본 연구에서는 암반에서의 열 전달과 관련된 열-역학적 거동을 평가하기 위한 현장 히터시험을 국내 최초로 실시하였다. 현장시험을 위해 현장조건과 시험 목적에 부합하는 시추공 히터시험을 설계하고 히터장치, 관측용 센서, 데이터로깅 시스템의 설치가 이루어졌다. 시험 구간에서의 노출면 조사를 통해 고경사 절리가 우세하게 분포함을 알 수 있었으며 암석코아에 대한 실험실 실험을 통해 히터시험구간에서의 주요 열, 역학적 암반 물성을 결정하였다. 암반의 온도분포 변화를 통해 암반 내에 존재하는 절리의 영향과 터널 벽면으로의 열손실을 파악할 수 있었으며 히터온도가 $90^{\circ}C$로 유지되는 경우, 히터공에서 0.3 m 떨어진 암반의 온도는 최대 $40^{\circ}C$까지 상승함을 알 수 있었다.

아두이노를 이용한 온도시험 장비 오동작 감시 시스템 설계 및 구현 (A Design and Implementation of the Temperature Testing Equipment Malfunction Monitoring System Using Arduino)

  • 윤명섭;박구락;고창배
    • 디지털융복합연구
    • /
    • 제14권5호
    • /
    • pp.317-323
    • /
    • 2016
  • 본 논문에서는 아두이노를 이용하여 온도시험 장비의 오동작이 발생이 되면, 이를 검출하여 주변에 이 정보를 알려 고가의 정밀 전자제품의 훼손을 방지할 수 있는 시스템을 제안한다. 정밀 전자제품은 출고전에 온도시험 장비를 이용하여 극저온, 극고온 온도 상황하에서 정상동작 여부를 확인하게 된다. 만약 이 상황하에서 장비의 오동작이 발생되면 고가의 제품이 손상을 입어 폐기하는 경우가 생긴다. 이 시스템은 특히 야간에 담당자가 없이 자동으로 시험이 진행될 때에 온도시험 장비 내에 온도 센서를 부착하여 시험 대상인 제품이 실제로 받고 있는 온도 정보를 아두이노를 이용하여 실시간으로 감시한다. 만약 시험자가 설정한 온도구간을 벗어날 경우 아두이노의 출력단에서 High 신호를 출력하여 경보 구동회로가 온도시험 장비의 전원을 차단하고 야간 근무부서의 근무자에게 이 정보를 알려, 온도 시험 중 발생할 수 있는 극고온 혹은 극저온 상황에서 고가의 시험대상 제품의 훼손을 방지할 수 있도록 설계 및 구현을 하였다. 본 논문에서 제안한 시스템은 장비의 제조사에 관계없이 모든 온도시험 장비에 적용가능하고, 저비용으로 제작 가능하다.

빙해선박 강재의 저온 소성경화 구성방정식 (Low Temperature Plastic Hardening Constitutive Equation for Steels of Polar Class Vessels)

  • 민덕기;허영미;조상래
    • 대한조선학회논문집
    • /
    • 제49권3호
    • /
    • pp.227-231
    • /
    • 2012
  • In this study, a plastic hardening constitutive equation for steels of polar class vessels at low temperature is proposed. The equation was derived using the experimental data obtained from tensile tests at room and low temperatures. Tensile tests at low temperature are both costly and time consuming because an expensive cold chamber is necessary and it takes too much time to cool down a specimen to set temperature. Using the proposed plastic hardening constitutive equation the plastic hardening characteristics of steels for polar class vessels at low temperature can be easily predicted from the tensile test results at room temperature.

핵융합로 블랭킷용 저방사화 철강재료 TIG 용접부의 강도특성 (Strength Characteristics of Reduced Activation Ferritic Steel for Fusion Blanket by TIG Welding)

  • 윤한기;이상필;김동현
    • Journal of Welding and Joining
    • /
    • 제21권1호
    • /
    • pp.87-92
    • /
    • 2003
  • JLF-1 steel (Fe-9Cr-2W-V-Ta), reduced activation ferritic steel, is one of the promising candidate materials for fusion reactor applications. Tensile properties of JLF-1 base metal and its TIG weldments has been investigated at the room temperature, $400^{\circ}C$ and $600^{\circ}C$. The tensile strength of base metal (JLF-1) showed the level between those of weld metal and the Heat Affected Zone (HAZ). When the test temperature was increased from room temperature to high temperature ($400^{\circ}C$ and $600^{\circ}C$), both strength and ductility decreased or base metal, weld metal and the HAZ. The longitudinal specimens of base metal represented similar strength and ductility at room temperature and high temperature, compared to those of transverse specimens. Little anisotropy for the rolling direction was observed in the base metal of JLF-1 steel.

Epoxy 수지의 경화 온도 의존성 (Hardening Temperature Dependence of Epoxy Resin)

  • 김태성;여인선;정화근;이진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.499-503
    • /
    • 1987
  • The electrical characteristics of Epoxy Robin vary with temperature. In this study, the variation of the electric characteristics of Epoxy Resin with various hardening temperature was studied. Epoxy Resin used as samples are Epotohto YD-128 of Diglycidyl Ether of Bisphenol A (DGEBA) series and hardener, Goodmide G-240. It's mixing rate is 3 to 1. Hardening temperature was varied from 25[$^{\circ}C$] to 50[$^{\circ}C$] by 5[$^{\circ}C$]. During the hardening progress, illumination, resistivity and the internal temperature of material which were dependet on the variety of hardening temperature were measured. The electrical properties of hardened samples were examined by means of X-ray diffraction, tan $\delta$ test, TG-DTA analysis and treeing test. On this basis, optimal hardening temperature in insulation characteristics was examined.

  • PDF