• Title/Summary/Keyword: Test Socket

Search Result 119, Processing Time 0.028 seconds

Acute Myeloid Leukemia Identified Incidentally in Patient with Infected Extraction Socket through Preoperative Screening Blood Test: A Case Report

  • Yuha, Jeong;Minwoo, Kang;Shin Young, Hyun;Jong-Ki, Huh;Jae-Young, Kim
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.141-146
    • /
    • 2022
  • Leukemia is a neoplastic disease with an excessive proliferation of immature white blood cells and their precursors. Common oral manifestations of acute myeloid leukemia (AML) include ulceration, petechiae, spontaneous bleeding, and gingival hyperplasia. The estimated prevalence of AML is 19 per 100,000 populations, the median age of diagnosis is over 65 years, and of all the subtypes of leukemia, AML accounts for the highest percentage of leukemic deaths. The purpose of this study is to report the case of a 77-year-old female patient, who visited our outpatient clinic due to consistent inflammatory findings. Though she received surgical treatment, she was diagnosed with AML by chance after a preoperative blood test. We also discuss the necessity of performing a preoperative blood test prior to invasive dental procedures such as tooth extraction or biopsy.

Study on Large Diameter Steel-cased Piles Socketed in Weathered and Fresh Rocks (풍화암과 연암에 근입된 대구경 말뚝의 축하중지지 거동에 관한 연구)

  • Nam Moon-Seok;Lee Min-Hee;Choi Yong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.3
    • /
    • pp.5-11
    • /
    • 2006
  • Two large diameter steel cased piles (TS-1 and TS-2) were installed and load-tested with the maximum load of 2000 ton at Kwang-An grand bridge. One of the test piles (TS-1) was socketed into the fresh rock and the other test pile (TS-2) was socketed into the weathered rock. Most loads were carried by the weathered rock layer at the maximum applied load for the test piles. In addition, numerical studies were performed using PENTAGON 3D and ROCKET. Based on this study, the weathered rock layer provided sufficient side resistances and possibility of an alternative embedded layer if weathered rocks are deeply layered over fresh rock, which caused difficulties and cost in construction.

Development of Internet-Based Propeller Design System (인터넷 기반 프로펠러 설계 시스템 개발)

  • 이왕수;박범진;이창섭
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.6
    • /
    • pp.69-79
    • /
    • 2003
  • Existing large-scale complex programs usually reside In a single computer, and the user has to be physically in contact with the computer. With the wide spread use of the internet, the need to carry out the design and analysis tasks geographically away from the main computer is increasing. In this paper existing Windows-based propeller design and analysis package is separated into the server-client modules and the protocol program is developed to implement the communication between multi-client computers and a single server computer. A new protocol packet is designed to use the Windows socket and the server/client programs control the receive/send operations using the information transmitted in the packet. Test runs show that the remote user, connected to the server computer through the internet only, can perform the required tasks.

Design and Implementation of NNI Interworking Protocol of OBP Satellite B-ISDN

  • Park, Seok-Cheon;Kang, Sung-Young;Kim, Jung-Hoon;Nam, Ki-Mo;Park, Jae-Kyun;Seo, Dong-Woon
    • Proceedings of the IEEK Conference
    • /
    • 2000.07b
    • /
    • pp.719-722
    • /
    • 2000
  • It is essential to develop the internetworking strategies between the OBP satellite B-ISDN and the terrestrial B-ISDN for the economical and efficient implementation of the future network infrastructure. We have considered the implementation issues of the emerging B-ISDN, especially interworking strategies of the terrestrial B-ISDN with the OBP satellite B-ISBN. We proposed interworking model between terrestrial B-ISDN and OBP satellite B-ISDN NNI signaling protocol, and describes the design and verification of the interworking protocol. For the verification, interworking protocol is modeled by Predicate/Action Net derived from Petri Net and the designed model is analyzed by reachability tree. Using Unix socket, the verified interworking protocol is implemented in two workstations and implemented interworking protocol is tested by local test method which is outstanding in error detection and recommended by ISO.

  • PDF

Case Study on the Vertical Capacity of the Repaired Large Diameter Rock-Socketed Stool Pipe Pile (보수된 대구경 암반 소켈강관말뚝의 연직지지력에 관한 사례연구)

  • 최용규;김승종;김병희;이광욱;김상일
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.185-192
    • /
    • 1999
  • It had found that, as a result of cross-hole tonic logging test, concrete was not filled partially within the bottom 2.0 m of the large diameter (Ø= 2,500mm) rock socketed pile, MP20-P11(socket diameter (Ø= 2,200mm), which was a pile among piles group supporting a pier of Kwangan Grand Bridge. The pile was repaired by the combined cement grout injected through the pipes for the cross-hole sonic logging test and the bore holes for core samples. A month after the cement grouting, repairing was checked by coring and cross-hole sonic logging then 3 times of grouting and 2 times of coring were, in turns, peformed, then repairing was completed successfully. The vertical compressive capacity of the repaired large diameter socketed pile was evaluated by several formulas and software ROCKET, and was more conservative than design load (1,882 ton) of MP20-P11. It is expected that, in the case of the battered socketed piles, it could be more reasonable to analyze the behaviors of a battered pile using 3-D model. A 3-D analysis will be peformed in the future study.

  • PDF

Clinical animal test for development of osseointegration implant;application for beagle tibia (골융합 임플란트 개발을 위한 동물임상실험;비글견 경골 적용)

  • Choi, Kyong-Joo;Kim, Shin-Ki;Mun, Mu-Seong;An, Jae-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1373-1377
    • /
    • 2003
  • Current prostheses for amputees are generally extrinsic wearing socket type that the coupling between body stump and appliance wraps the soft tissue and this structure causes several problems :applying direct weight to soft tissue such as skin and muscle, skin trouble of contacting area and pain. In this study, osseointegration implant is a method to directly connect prosthesis to the residual stump skeletal tissue of arm, finger and leg through surgical operation. Technology presented in this paper essentially solves the problems of pain and abnormal weight transfer system indicated above and recovers the functions of the amputated arm and leg. In this paper, implant shape was designed for the first step for the development of osseointegration implant and then we studied the possibility to apply this osseointegration implant to human body by performing implant insertion operation to beagle tibia for the clinical animal test and normal beagle's gait analysis was executed in order to quantitatively verify the beagle's skeletal functions after the implant insertion.

  • PDF

Prediction of EFT/B Signal Transfer Characteristics in Mobile Charging Circuit (모바일 충전회로에서 EFT/B 신호의 전달특성 예측에 대한 연구)

  • Song, SeungJae;Kim, Kwangho;Jo, Jeongmin;Lee, Seungbae;Kim, So-young;Nah, Wansoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.10
    • /
    • pp.895-906
    • /
    • 2015
  • This paper presents a methodology and a model that can analyze the high frequency transfer characteristics from socket in the AC power port to the 5 V DC output port in the mobile charging circuit. This is to predict the output signals coming from the IEC(International Electrotechnical Commission) Standard(IEC 61000-4-4), EFT/B(Electric Fast Transient and Burst) immunity test for mobile charging circuit. Since the mobile charging circuit is energized from the AC power socket from the power line, it is necessary to know the high frequency transfer characteristics with activated AC power line. A simple CDN(Coupling-Decoupling Network) is designed and manufactured for measuring S-parameters of mobile charging circuit with and without AC power line activated. The result shows that the S-parameters of the specific mobile charging circuits are almost the same, independent of AC power line activation. Consequently, the S-parameters without AC line could be used to predict the output response to the EFT/B signals, and it was shown that the proposed methodology predicts the output responses quite accurately, which proves the validness of the methodology presented in this paper.

Design of a Service Broker for Large Scale Connections to Support Pubsub QoS between TOS and Mobile Devices (TOS와 Mobile device 간의 펍섭 QoS를 지원하는 대량 커넥션 서비스 브로커 설계)

  • Jeon, Young-Jun;Hwang, Hee-Joung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.5
    • /
    • pp.137-142
    • /
    • 2016
  • A two-step open system(TOS) was proposed to relay between a healing platform and a repository of personal health documents. TOS was designed by taking into consideration the pubsub service based on large scale connections to monitor a provider's access/request process for health documents in real time. TOS, however, uses WebSocket as a communication protocol in case of pubsub. Given the operational environment of low quality wireless networks for mobile devices that are user terminals in a healing platform, there is a need to add a messaging protocol to support QoS as well as a transmission protocol. As a light messaging protocol optimized for mobile devices, MQTT defines reliable messaging QoS to consider a wireless network situation of low speed/low quality. This study designed an MQTT protocol-based message broker to support QoS in case of large scale connections and pubsub by taking into consideration mobile devices that are user terminals in a healing platform. After designing a model between TOS and MQTT message broker, the study implemented a prototype based on the proposed design and compared it with its counterparts from previous studies based on the performance indicators in a load-test with the MQTT client tool.

The Resistance Characteristics and Reliability Evaluation of an Insulation Ring Type of Corrugated Stainless Steel Tubing(CSST) (절연링형 금속플렉시블호스(CSST)의 저항 특성 및 신뢰성 평가)

  • Lee, Jang-Woo;Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.25-31
    • /
    • 2016
  • This paper has analyzed the structure, applicable regulations and the resistance characteristics of insulation ring type of CSST (Corrugated Stainless Steel Tubing for Gas). With the flammability test conducted in accordance with KS C IEC 60811-1-1, the evaluation of insulation resistance, temperature characteristics, and reliability has been conducted. An insulation ring type CSST consists of protective coating, tube, nut, insulation ring, packing, socket, and ball valve. Connecting an insulation ring type CSST to gas tubings for gas appliance is not permitted, moreover, the product shall be installed inside a sleeve pipe in case of buried installation such as the ceiling. Damages on protective coating and tube were detected when fire was applied to the test sample with a portable torch for 60 seconds. The insulation resistance of a normal product was $49.59M{\Omega}$, while that of the product completed the flammability test reduced to $9.21M{\Omega}$. The mean insulation resistance within the confidence Interval of 95% using the mini tap program 17 was $49.59M{\Omega}$ and the mean insulation resistance within the confidence interval reduced to $9.21M{\Omega}$. In the normal distribution analysis of 95% confidence interval, the value-P of the normal product was stable at 0.075 and AD(Anderson-Darling) statistic value was turned out to be 0.063, which is very normal, and the standard deviation was analyzed as 0.2586. The value P of the product completed the flammability test resulted in 0.005, the AD was 1.355 and the standard deviation reduced to 0.07908.

The effect of alendronates administration duration on the healing of extraction socket in rats: pilot study (알렌드로네이트의 투여기간이 발치와의 치유에 미치는 영향: 예비실험)

  • Kim, Jee-Hwan;Hong, Jong-Hwan;Choi, Hyun-Min;Park, Young-Bum;Moon, Hong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.3
    • /
    • pp.175-182
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the effect of different administration duration of alendronate on initial wound healing and new bone formation of extraction socket in rats. Materials and methods: Fifteen male Sprague-Dawley rats (body weight 130-140 g, 4 weeks old, male) were divided into control group (no alendronate administration) and experimental group (alendronate administration). Experimental group was subdivided into 1 week administrated group, 2 week administrated group, 4 week administrated group and 6 week administrated group according to duration of administration. For the experimental groups, during the designated time period (at the time of extraction, 1 week before extraction, 3 week before extraction and 5 week before extraction) till 1 week after extraction, rats were subcutaneously injected with Alendronate at the dose of 1.0 mg/Kg three times a week. Each specimen from 6 week experimental group and control group were used for microarray analysis, and other specimens were used for histological analysis. The rate of new bone formation within the extraction site and bone loss activity was analyzed using TRAP staining. Statistical analysis was performed using Kruskal Wallis test. (${\alpha}=.05$) Results: After one week from the time of extraction, the rate of new bone formation within extraction site for the control group ($16.77%{\pm}1.36%$) compared to the 4 week experimental group ($14.99%{\pm}6.26%$) was lower. However, no statistically significant difference was found. Increase in the number of inactive lacuna (empty lacuna) and decrease in the number of TRAP positive cell were identified with increased duration of administration. There was no significant difference. Conclusion: The results of this study showed as the duration of Alendronate administration increased the rate of new bone formation decreased with loss of bone activity and reduced number of osteoclast.