• Title/Summary/Keyword: Test Socket

Search Result 119, Processing Time 0.028 seconds

Research on the Performance Test of System in Package Chips for the Digital Broadcasting Receiver (디지털 방송 수신용 System in Package 칩의 성능 검사에 관한 연구)

  • Kim, Jee-Gyun;Lee, Heon-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2228-2233
    • /
    • 2008
  • This research paper aims to establish a test process of the AFE SiP chip. It measured the sensitivity, current consumption and power consumption both on the evaluation socket board and Catalyst load board. As a result, the sensitivity became deteriorated with an average of 0.2[dBm] at the channel 62 only, the current consumption increased to an average of 0.57[mA] and the power consumption increased to an average of 1.76[mW], But all characteristics incomes the tolerance of the measurement, it also keeps almost the same level. Therefore this design of the test process improved a valid design.

Evaluation and Performance Test of Ball and Socet type Suspension Insulator for 300 kN Ultra High Voltage (300kN 초고압용 초고압용 볼소켓형 현수애자의 성능평가)

  • Kim, S.S.;Kim, K.U.;Her, J.C.;Cho, H.G.;Park, T.G.;Seo, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2026-2028
    • /
    • 2000
  • As the results of evaluation of its performance for 300 kN Ball and Socket type suspension insulators. There was electrically internal puncture of the solid insulating body of the insulating due to the steep front impulse voltage, which usually occurs puncture before external flash-over of insulators, moreover we have obtained satisfactory results in power arc test of 7.2kA cycle fatigue test with high qualify control index of 4.6, especially we have obtained more satisfactory results than that before improvement of its materials.

  • PDF

Patterns and Characteristics of Corrugated Stainless Steel Tubing for a Yellow Insulation Ring Type by Artificially Deteriorated (인위적으로 열화된 황색절연링형 금속플렉시블호스의 패턴 및 특성)

  • Lee, Jang-Woo;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.1-6
    • /
    • 2018
  • This study is to analyze the characteristics of the yellow insulation ring type of the CSST used for tubing when it is artificially deteriorated and damaged by burning. The CSST for tubing consists of a tube, protective coating, nut, yellow insulation ring, packing, and socket. In addition, it is thought that a yellow insulation ring and rubber packing were used to connect the tube and socket in order to improve the airtightness and insulation performance. The result of the verification of the data acquired from the tests in the 95% confidence interval shows that the Anderson-Darling (AD) and P value were analyzed to be 0.945 and 0.015, respectively. This confirms that the test data of the CSST for tubing is reliable. The analysis of the arithmetic mean of the insulation resistance of a CSST showed that the CSST damaged by burning by a torch, and the one damaged by electrical burning, was $16.7k{\Omega}$ (the greatest relatively) and $208{\Omega}$ (the lowest), respectively, while it was $1.72k{\Omega}$ in the case of a normal product. Therefore, the analysis result of the insulation resistance of the CSST collected from the scene of a fire can be utilized to examine the cause of damage by burning. In addition, it was found that when the maximum current of 97 A was applied to the CSST for about 5 s using a Primary Current Injection Test System (PCITS) the protective film and insulation ring of the CSST has no difference from that of a normal product. However, a part of the metal tube was melted.

Effect of resorbable membrane on immediate placement of implant in extraction socket during periradicular surgery (치근단 수출 시 형성된 골결손 부위를 가진 치아의 발치 후 즉시 식립 임플란트에서 골 접촉률에 대한 흡수성 차폐막의 효과)

  • Yang, Seung-Min;Kye, Seung-Beom;Shin, Seung-Yun
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.4
    • /
    • pp.603-610
    • /
    • 2008
  • Purpose: The guided bone regeneration (GBR) technique is widely used in periradicular surgery. However, there is still some controversy regarding the effectiveness of GBR in promoting bone healing after periradicular surgery. The purpose of this study was to evaluate the resorbable membrane on the osteointegration of immediate implants in sites with periradicular lesion that had been removed by periradicular surgery. Materials and methods: Six roots of lower second premolars and 15 roots of lower third and fourth premolars of dogs were used as control and experimental teeth, respectively. Periradicular lesions were induced only in the experimental teeth. Twelve weeks later, the control and experimental teeth were extracted and implants were placed immediately. Periradicular lesions were removed with osteotomy, curettage and saline irrigation. Resorbable membranes were used in experimental group 1 but not in experimental group 2. After 12 week of healing period, the implants were clinically not mobile and showed no signs of infection. Data obtained by histomorphometric analysis were analyzed by Kruskal-Wallis test. Results: The control group showed a significantly higher bone to implant contact (BIC) ($74.14{\pm}16.18$) than experimental group 1 ($40.28{\pm}15.96$) and 2 ($48.70{\pm}17.75$)(p<0.05). However, there was no significant difference between experimental group 1 and 2. Conclusion: Although BIC in experimental groups were lower than in control group, immediate implant can be successfully placed at extraction socket with periradicular lesion and osseous defect. However, the use of resorbable membrane in bony defect created during periradicular surgery was questioned.

An Evaluation of Multimedia Data Downstream with PDA in an Infrastructure Network

  • Hong, Youn-Sik;Hur, Hye-Sun
    • Journal of Information Processing Systems
    • /
    • v.2 no.2
    • /
    • pp.76-81
    • /
    • 2006
  • A PDA is used mainly for downloading data from a stationary server such as a desktop PC in an infrastructure network based on wireless LAN. Thus, the overall performance depends heavily on the performance of such downloading with PDA. Unfortunately, for a PDA the time taken to receive data from a PC is longer than the time taken to send it by 53%. Thus, we measured and analyzed all possible factors that could cause the receiving time of a PDA to be delayed with a test bed system. There are crucial factors: the TCP window size, file access time of a PDA, and the inter-packet delay that affects the receiving time of a PDA. The window size of a PDA during the downstream is reduced dramatically to 686 bytes from 32,581 bytes. In addition, because flash memory is embedded into a PDA, writing data into the flash memory takes twice as long as reading the data from it. To alleviate these, we propose three distinct remedies: First, in order to keep the window size at a sender constant, both the size of a socket send buffer for a desktop PC and the size of a socket receive buffer for a PDA should be increased. Second, to shorten its internal file access time, the size of an application buffer implemented in an application should be doubled. Finally, the inter-packet delay of a PDA and a desktop PC at the application layer should be adjusted asymmetrically to lower the traffic bottleneck between these heterogeneous terminals.

Shear Tests Under Constant Normal Stiffness for Granite-concrete Interface (화강암 절단면과 콘크리트 부착면에 대한 일정강성도 전단시험)

  • 조천환;이명환;유한규
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.1
    • /
    • pp.5-12
    • /
    • 2004
  • The purpose of this paper is to make an understanding of fundamental mechanism of shear behaviour between rock and concrete interfaces in the pile socketed into granite. The interface of pile socketed in rock can be modeled in laboratory tests by resolving the axi-symmetric pile situation into the two dimensional situation under CNS(constant normal stiffness) direct shear condition. In this paper, the granite core samples were used to simulate the interface condition of piles socketed in granite in our country. The samples were prepared in the laboratory to simulate field condition, roughness(angle and height), stress boundary condition, and then tested by CNS direct shear tests. This paper describes shearing behaviour of socket piles into domestic granite through the analysis of CNS test results. It was found out that the peak shear strength increases with the angle of asperity and CNS value, and also the dilation increases with the angle of asperity but decreases with the CNS value.

Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography

  • Yousefi, Faezeh;Shokri, Abbas;Farhadian, Maryam;Vafaei, Fariborz;Forutan, Fereshte
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose: This study aimed to compare the accuracy of 3-dimensional(3D) printed models derived from multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) systems with different fields of view (FOVs). Materials and Methods: Five human dry mandibles were used to assess the accuracy of reconstructions of anatomical landmarks, bone defects, and intra-socket dimensions by 3D printers. The measurements were made on dry mandibles using a digital caliper (gold standard). The mandibles then underwent MDCT imaging. In addition, CBCT images were obtained using Cranex 3D and NewTom 3G scanners with 2 different FOVs. The images were transferred to two 3D printers, and the digital light processing (DLP) and fused deposition modeling (FDM) techniques were used to fabricate the 3D models, respectively. The same measurements were also made on the fabricated prototypes. The values measured on the 3D models were compared with the actual values, and the differences were analyzed using the paired t-test. Results: The landmarks measured on prototypes fabricated using the FDM and DLP techniques based on all 4 imaging systems showed differences from the gold standard. No significant differences were noted between the FDM and DLP techniques. Conclusion: The 3D printers were reliable systems for maxillofacial reconstruction. In this study, scanners with smaller voxels had the highest precision, and the DLP printer showed higher accuracy in reconstructing the maxillofacial landmarks. It seemed that 3D reconstructions of the anterior region were overestimated, while the reconstructions of intra-socket dimensions and implant holes were slightly underestimated.

Bit Register Based Algorithm for Thread Pool Management (스레드 풀 관리를 위한 비트 레지스터 기반 알고리즘)

  • Shin, Seung-Hyeok;Jeon, Jun-Cheol
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.2
    • /
    • pp.331-339
    • /
    • 2017
  • This paper proposes a thread pool management technique of an websocket server that is applicable to embedded systems. WebSocket is a proposed technique for consisting a dynamic web, and is constructed using HTML5 and jQuery. Various studies have been progressing to construct a dynamic web by Apache, Oracle and etc. Previous web service systems require high-capacity, high-performance hardware specifications and are not suitable for embedded systems. The node.js which is consist of HTML5 and jQuery is a typical websocket server which is made by open sources, and is a java script based web application which is composed of a single thread. The node.js has a limitation on the performance for processing a high velocity data on the embedded system. We make up a multi-thread based websoket server which can solve the mentioned problem. The thread pool is managed by a bit register and suitable for embedded systems. To evaluate the performance of the proposed algorithm, we uses JMeter that is a network test tool.

Development of the Spherical Flange used in a Cryogenic High Pressure Pipe (극저온 고압 배관용 구형 플랜지 개발)

  • Moon, Il-Yoon;Moon, In-Sang;Yoo, Jae-Han;Lee, Soo-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.283-288
    • /
    • 2011
  • The spherical flange was designed to apply to a cryogenic high pressure pipe of the Liquid Rocket Engine. It is designed that the spherical flange is able to be assembled and kept airtight upto $2.5^{\circ}$ of the axial misalignment between the combined components. It increases the degree of freedom of the engine assembly. The spherical flange is composed of a ball and socket joint, a metal seal and spherical type bolts, washers. The prototype was verified by leak test at the room temperature and the cryogenic temperature. Additionally the strength test and the destructive test were performed at the room temperature.

  • PDF

Development of the Spherical Flange Used in a Cryogenic High Pressure Pipe (극저온 고압 배관용 구형 플랜지 개발)

  • Moon, Il-Yoon;Moon, In-Sang;Yoo, Jae-Han;Lee, Soo-Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.3
    • /
    • pp.64-69
    • /
    • 2011
  • The spherical flange was designed to apply to a cryogenic high pressure pipe of a liquid rocket engine. It is designed that the spherical flange is able to be assembled and kept airtight up to $2.5^{\circ}$ of the axial misalignment between the combined components. It increases the degree of freedom of the engine assembly. The spherical flange is composed of a ball and socket joint, a metal seal, spherical type bolts and washers. The prototype was verified by leak test at the room temperature and the cryogenic temperature. Additionally the strength test and the destructive test were performed at the room temperature.