• Title/Summary/Keyword: Test Report

Search Result 2,944, Processing Time 0.038 seconds

Subscriber Line Maintenance Operations System (SLMOS) (전화국 시험실업무 자동화 시스템개발)

  • 강성수;김동수
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1983.10a
    • /
    • pp.118-123
    • /
    • 1983
  • A minicomputer system with the purpose of automations the operations of a Repair Service Bureau is described. SLMOS automates three major functional areas-administration, testing, and report senerations In the administration of repair sevice SLMOS performs a database maintenance functions alons with trouble collection and tracking. Trough ALT, automated testing of customer lines is performed, and the results of the test are utilized to dertermine the action taken to effect a repair. Certain problem areas may be detected and corrected by using the reports senerated by Trouble Report statics and Analysis System.

  • PDF

Analysis on the Propulsive Performance of Full Scale Ship (실선의 추진성능 해석기법에 관한 연구)

  • Yang, Seung-Il;Kim, Eun-Chan
    • 한국기계연구소 소보
    • /
    • s.9
    • /
    • pp.183-191
    • /
    • 1982
  • This report describes the analysis method of the full-scale propulsive performance by using the data of model test and the full-scale speed trial. The model test data were analyzed by the computer program "PPTT" based on "1978 ITTC Performance Prediction Method for Single Screw Ships." Also the full-scale speed trial data were analyzed by the computer program "SSTT" based on the newly proposed “SRS-KIMM Standard Method of Speed Trial Analysis." An analysis of model and full-scale test data was carried out for a 60.000 DWT Bulk Carrier and the correlation between model and full-scale ship was stuied.

  • PDF

Reliability Tests on SpatiaLight's LCOS Microdisplays

  • Shin, Dong-Soo;Sun, Raymond;Jin, Michael
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.951-954
    • /
    • 2004
  • We report the recent reliability test results of SpatiaLight's liquid crystal on Silicon (LCOS) microdisplays. Two different types of reliability tests have been performed: 1) thermal and 2) thermal with high intensity UV light. Various important device parameters were regularly monitored including the contrast ratio, color uniformity, and switching time. The test data shows that there are no degradations that fail the pass criteria. Lifetime estimations are given from the test data.

  • PDF

Adhesive Performance of Waterproofing System on Concrete Substrate with Moisture Condition (콘크리트 표면 함수비에 따른 교면방수재료의 인장접착성능)

  • 박성기;심재원;이병덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.979-984
    • /
    • 2001
  • Poor water-proofing integrity is related to many factors : site procedure, workmanship, weather. substrate conditions, installation(including asphalt application) conditions. The evaluation of adhesive properties tested by concrete surface moisture and asphalt application was based on laboratory test and observations. This report describes the pull-off test results of waterproofing systems currently used for installing and reparing for concrete bridge decks. The test results showed that the moisture condition fully affected the adhesive properties of sheet membranes and sealer but partially for liquid membranes.

  • PDF

Tendency of Calibration and Test for Acoustic Field in KRISS (KRISS에서 수행된 음향관련 교정 및 시험 동향)

  • 서재갑;권휴상;정성수;조문재;서상준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.448-452
    • /
    • 2002
  • We report the number of calibration and test for acoustic field which were conducted in KRISS between the year of 1990 and 2001. The items contain sound level meter and calibrator for calibration and sound absorption coefficient, transmission loss, sound pressure level of siren, sound pressure level and power of acoustic instrument and relative accessories for test. The data show that the number of them have been increased continuously.

  • PDF

A case report of Benign Paroxymal Positional Vertigo Patient (귀비탕가미방(歸脾湯加味方) 복용 후 호전된 양성 돌발성 체위성 현훈 환자 1례)

  • Jeong, Dal-Lim;Hong, Seung-Ug
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.21 no.2
    • /
    • pp.198-205
    • /
    • 2008
  • Objective : We report a case of BPPV responded to the Guibitang, Spleen Tonifying Sa-Am Acupuncture and Canalith Reposition Therapy. Methods : 1. Diagnosis and Evaulation: Bithermal Caloric test, Video Nystagmography, Dix-Hallpike test, VAS 2. Treatment: Guibitang, Acupuncture, Canalith Reposition Therapy. Results : We can observe remarkable improvement evaulated by VAS. Conclusion : It is considered that Guibitang and Acupuncture can be applied to the treatment of BPPV.

  • PDF

Dirofilaria immitis infection in wild raccoon dogs, Nyctereutes procyonoides (야생너구리 (Nyctereutes procyonoides)의 개 심장사상충 (Dirofilaria immitis) 감염)

  • Song, Kun-Ho;Lee, Il-Berm;Kim, Duck-Hwan
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.4
    • /
    • pp.545-550
    • /
    • 2002
  • The raccoon dog (Nyctereutes procyonoides) may be infected by Dirofilaria immitis. However, there has been no report on dirofilarial infection in the raccoon dog in Korea. In this study, we report on D. immitis infection in two wild raccoon dogs captured in the Daejeon area. The two raccoon dogs were referred to the Veterinary Teaching Hospital, Chungnam National University for diagnosis of D. immitis infection. The modified Knott's test for the detection of blood D. immitis microfilariae was positive, and serological test (FASTest$^{(R)}$ HW Antigen ELISA kit, Diagnostik Mega Cor, Austria) for D. immitis was positive as well. Additionally, D. immitis microfilariae were differentiated from other microfilariae by using acid phrnphatase histochemical staining (Leucognost-SP$^{(R)}$kit, Diagncstica MERCK, Germany). The two raccoon dogs were necropsed and D. immitis infection was confirmed.

Subclinical Hypothyroidism during Quetiapine Treatment : A Case Report (Quetiapine 치료 중 발생한 무증상 갑상선 기능저하증 1례)

  • Na, Kyeong-Sae;Kim, Yong-Ku
    • Korean Journal of Biological Psychiatry
    • /
    • v.14 no.1
    • /
    • pp.68-71
    • /
    • 2007
  • Quetiapine is an atypical antipsychotic drug with a benign side effect profile. However, recent studies have reported that thyroid dysfunction is associated with quetiapine treatment. The authors report a patient with DSM-IV bipolar I disorder who developed subclinical hypothyroidism during quetiapine treatment. The patient showed no significant clinical symptoms, but only abnormal thyroid function test findings including antithyroglobulin antibody. The abnormal thyroid function test findings were normalized after discontinuation of quetiapine. The subclinical hypothyroidism developed during quetiapine treatment may be associated with autoimmune process.

  • PDF

Test Rally to Exchange Product Model (제품 모델 교환 테스트 랠리)

  • 박상호;이병훈;김준형;한순흥;유상봉
    • Korean Journal of Computational Design and Engineering
    • /
    • v.9 no.1
    • /
    • pp.11-18
    • /
    • 2004
  • CAD systems have been developed with network technology and it is needed to exchange product data among them. STEP becomes world-wide international standard to exchange CAD data among various heterogeneous CAD systems in manufacturing industrial fields. We report results to test errors that can happen when exchanging STEP files of product model through the STEP translator of different commercial CAD systems. Also the tests of Korean Character, Hangul, have been carried out. And also we report the STEP rallies held twice in Korea and several rounds abroad, and their testing results are shown as tables and graphs. The tested results can be used for exchanging product models to the next domestic STEP Rally and extended to Northeastem Asian STEP rally by steadily contacting with the organizations for Asian STEP centers such as JSTEP(Japan) and CSTEP(China). Finally we expect that the result can be used to specify STEP standardization in the field of managing product data.

Manufacturing and Dynamic Performance test for Prototype Bogie of half Maglev vehicle (자기부상열차 시험용 1/2차량 대차제작과 주행성능 실험)

  • Lee, Nam-Jin;Han, Hung-Suk;Lee, Wan-Sang;Kim, Chul-Geun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1575-1580
    • /
    • 2009
  • Maglev vehicle has two kinds of suspension system such as a secondary suspension with air-spring and a primary suspension as electromagnetic suspension which composed of electromagnet, magnet driver, controller and sensors. The interaction between each dynamic component of vehicle and track effects the stability and running performance. To achieve the specified performance of vehicle, many various approaches of research were tried, then as the result of these efforts, the first commercial operating with Maglev will start soon. The bogie for revenue service from 2012 has some significant modifications compared to the previous one, and to verify the changes the half prototype vehicle was manufactured and took the running performance test. In this report, we will introduce the stage of manufacturing and report results of dynamic performance tests to verify new concept of bogie mechanism.

  • PDF