• 제목/요약/키워드: Test Plant

검색결과 3,798건 처리시간 0.03초

석탄화력발전소 보일러 연료제어 알고리즘과 분산제어시스템의 개발 (The Development of Boiler Fuel Control Algorithm and Distributed Control System for Coal-Fired Power Plant)

  • 임건표;이흥호
    • 전기학회논문지P
    • /
    • 제62권1호
    • /
    • pp.36-44
    • /
    • 2013
  • This paper is written for the development and application of boiler fuel control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. Fuel control algorithm has the upper algorithm and it is boiler master control algorithm that controls the fuel, feed water, air by generation output demand. Generation output demand by power load influences fuel control. Because fuel can not be supplied fast to the furnace of boiler, fuel control algorithm was designed adequately to control the steam temperature and to prevent the explosion of boiler. This control algorithms were coded to the control programs of distributed control systems which were developed domestically for the first time. Simulator for coal-fired power plant was used in the test step. After all of distributed control systems were connected to the simulator, the tests of the actual power plant were performed successfully. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.

석탄화력발전소 보일러 노내압력 제어알고리즘과 분산제어시스템의 개발 (The Development of Boiler Furnace Pressure Control Algorithm and Distributed Control System for Coal-Fired Power Plant)

  • 임건표;허광범;박두용;이흥호
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.117-126
    • /
    • 2013
  • This paper is written for the development and application of boiler furnace pressure control algorithm and distributed control system of coal-fired power plant by the steps of design, coding, simulation test, site installation and site commissioning test. The control algorithms were designed in the shape of cascade control for two parts of furnace pressure control and induced draft fan pitch blade by standard function blocks. This control algorithms were coded to the control programs of distributed control systems. The simulator for coal-fired power plant was used in the test step and automatic control, sequence control and emergency stop tests were performed successfully like the tests of the actual power plant. The reliability was obtained enough to be installed at the actual power plant and all of distributed control systems had been installed at power plant and all signals were connected mutually. Tests for reliability and safety of plant operation were completed successfully and power plant is being operated commercially. It is expected that the project result will contribute to the safe operation of domestic new and retrofit power plants, the self-reliance of coal-fired power plant control technique and overseas business for power plant.

자기베어링 지지 모터-발전기 시스템 개발 (Development of An Active Magnetic Bearing-based Motor-Generator System)

  • 김종문;김춘경;김국헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.127-129
    • /
    • 1997
  • In this paper, an active magnetic bearing-based motor-generator(M-G) system is designed and controlled by using DSP devices. Several experiments including start-up test, impulse test, whirl test, and generator load test are conducted using digital PID algorithm and AC power of about 58Hz, 100V, 0.8A can be generated from the M-G set.

  • PDF

LNG 시험 플랜트의 정량적 위해도 평가를 위한 화재 및 폭발사고 해석 (Fire and Explosion Analysis for Quantitative Risk Assessment on LNG Test Plant)

  • 한용식;김명배;도규형;김태훈;최병일
    • 한국연소학회지
    • /
    • 제20권1호
    • /
    • pp.1-5
    • /
    • 2015
  • Fire and explosion analysis are performed for the quantitative risk assessment on the LNG test plant. From the analysis for a case of fire due to large leakage of LNG from the tank, it is obtained that loss of lives can be occurred within the radius of 60 m from the fire origin. Specially, wind can extend the extent of damage. Because the LNG test plant is not enclosed, the explosion overpressure is less than 6 kPa and the explosion has little effect on the integrity of the LNG test plant.

구제역 백신의 국가출하승인검정을 통한 품질 평가 (Evaluation for foot-and-mouth disease vaccines in South Korea by the test for national lot release)

  • 김문현;서민구;이향심;김지연;김지예;김용상;김연희
    • 한국동물위생학회지
    • /
    • 제42권4호
    • /
    • pp.285-288
    • /
    • 2019
  • Foot-and-mouth disease (FMD) causes economic problems in livestock industry because of fast spread and inducing low productivity. FMD outbreaks occurred in South Korea over the period from 2000 to 2019. Vaccination is the most practical and effective means of controlling or preventing these outbreaks, and a national vaccination policy has been in place for all FMD-susceptible animals since 2010. To prevent and control of FMD, South Korea has been using vaccines imported from the United Kingdom, Argentina, and Russia. The Animal and Plant Quarantine Agency of South Korea oversees continuous quality control of imported FMD vaccines. FMD vaccines were evaluated characteristics, sterility, pH, inactivation, safety, potency test by Korean FMD vaccine standard assay (Test for National Lot Release). The 6 company vaccines (A~F) were used Test for National Lot Release by each method. We evaluated quality of each FMD vaccine from 2015 to 2019. All batch of vaccine showed good quality control and were passed the Test for National Lot Release. The serotypes of vaccine are increasingly changing to multiple vaccine because the FMD was outbreak by various serotype virus in South Korea. Furthermore, this data may be useful as a basis for ensuring the quality of FMD vaccines and for base data to manage them. Additional study is required to simple approach for rapid evaluation of quality and antigen content identification in vaccines.

시스템엔지니어링 방법론을 적용한 소프트웨어 테스트 케이스 개발에 관한 연구 (A Study on the Software Test Case Development using Systems Engineering Methodology)

  • 살림셀리;신중욱;김진일
    • 시스템엔지니어링학술지
    • /
    • 제14권2호
    • /
    • pp.83-88
    • /
    • 2018
  • Software has become an integral part of almost any system, triggered by the ever-growing demand for automation and artificial intelligent throughout engineering domains. The complexities of software-centric systems are also increasing, which make software test efforts become essential in software development projects. In this study, we applied systems engineering methodology in generating software test cases. We found out the similarities between requirements analysis and traceability concept of systems engineering and test specification contents of software test. In terms of acceptance test, software test cases could be considered as validation requirements. We also suggested a method to determine test order using a SysML modeling tool.

Correlations in the results of virus neutralization test, hemagglutination inhibition test, and enzyme-linked immunosorbent assay to determine infectious bronchitis virus vaccine potency

  • Park, Mi-Ja;Joh, Seong-Joon;Choi, Kang-Seuk;Kim, Aeran;Seo, Min-Goo;Song, Jae-Young;Yun, Seon-Jong
    • 대한수의학회지
    • /
    • 제56권3호
    • /
    • pp.189-192
    • /
    • 2016
  • The virus neutralization (VN) test was used to determine potency of the infectious bronchitis (IB) vaccine. The results of VN, hemagglutination inhibition (HI), and enzyme-linked immunosorbent assay (ELISA) were compared with those of the IBV M41. The $r^2$ values between VN and HI titers and the ELISA antibody titer were 0.8782 and 0.0336, respectively, indicating a high correlation between VN and HI, but not VN and ELISA. The Cohen's kappa coefficient between the VN titer of 2 $log_{10}$ and HI titer of 5 $log_2$ was 0.909. Our results showed that VN could be replaced with HI for testing the potency of IBV M41.

국내 가축에서 브루셀라병에 대한 혈청학적 모니터링 (Serological monitoring on brucellosis in livestock of Korea)

  • 성소라;김지연;허문;이기찬;강성일;이향근;조효림;이진주;정석찬
    • 대한수의학회지
    • /
    • 제54권4호
    • /
    • pp.197-201
    • /
    • 2014
  • In Korea, brucellosis has been reported periodically in cattle and rarely in dogs; however, it has not previously been screened in domestic animals such as elk, pigs and goats. To investigate the serological prevalence, serum samples were taken from the aforementioned animals annually during 2007-2013 and screened by the rose-bengal test (RBT) or modified RBT, after which positive sera were evaluated by the standard tube agglutination test (STAT). Finally, RBT and STAT-positive sera were confirmed by competitive-ELISA. Brucella abortus biovar 1 was isolated from three elk that were shown to be positive serologically in 2008. There was no evidence of brucellosis in pigs. Based on serological monitoring and investigation of etiological agents, there is no evidence of outbreak of brucellosis in elk, pigs or goats of Korea since 2008. However, the possibility for brucellosis from cattle to affect these other livestock exists; therefore, extensive and continuous serological monitoring is required to maintain their brucellosis-free status.

신규 화력발전소의 성능 시험을 통한 터빈 효율의 평가에 관한 연구 (A Study on the Evaluation of Turbine Efficiency through the Performance Test of New Power Plant)

  • 권영수;정희택;정양범
    • 동력기계공학회지
    • /
    • 제5권1호
    • /
    • pp.11-20
    • /
    • 2001
  • Super-critical type steam power plant, which operates with steam pressure above the super-critical point, has a good reputation recently and is adopted as a new standard of the Korean Electric Power Corporation. The reason for the good reputation lies in it's superior power efficiency. However, the field data of the new power plant for the verification of it's performance are still insufficient, and more empirical data are needed to acquire technologies on the effective operation of it. In this study, the authors analyzed the field test data on power efficiencies got in a super-critical type steam power plant, and evaluated the excellency of the new plant by comparing the efficiency data with the one got in a conventional sub-critical type steam power plant.

  • PDF