• 제목/요약/키워드: Test Limit

Search Result 2,150, Processing Time 0.031 seconds

Experimental study on fatigue behavior of innovative hollow composite bridge slabs

  • Yang Chen;Zhaowei Jiang;Qing Xu;Chong Ren
    • Steel and Composite Structures
    • /
    • v.46 no.6
    • /
    • pp.745-757
    • /
    • 2023
  • In order to study the fatigue performance of the flat steel plate-lightweight aggregate concrete hollow composite bridge slab subjected to fatigue load, both static test on two specimens and fatigue test on six specimens were conducted. The effects of the arrangement of the steel pipes, the amplitude of the fatigue load and the upper limit as well as lower limit of fatigue load on failure performance were investigated. Besides, for specimens in fatigue test, strains of the concrete, residual deflection, bending stiffness, residual bearing capacity and dynamic response were analyzed. Test results showed that the specimens failed in the fracture of the bottom flat steel plate regardless of the arrangement of the steel pipes. Moreover, the fatigue loading cycles of composite slab were mainly controlled by the amplitude of the fatigue load, but the influences of upper limit and lower limit of fatigue load on fatigue life was slight. The fatigue life of the composite bridge slabs can be determined by the fatigue strength of bottom flat steel plate, which can be calculated by the method of allowable stress amplitude in steel structure design code.

A Comparative Study on Liquid Limit Value by Liquid Limit Tests (시험방법에 따른 액성한계치의 비교 연구)

  • Jang Jeong-Wook;Park Choon-Sik;Ha Joo-Hwa;Chung Youn-In
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.17 no.2
    • /
    • pp.80-85
    • /
    • 2005
  • This study, Using Pusan clay, examined a relationship between Dynamic and Static Liquid Tests. The Static Liquid Tests were carried out based on BS and JIS. The results of the study are summarized as follows. (1) The result of the Dynamic Liquid Limit Test showed that the liquid limit values of Natural condition soil were greater than those of oven-dried soil by $4\%\~15\%$. (2) The liquid limit value of the Static Liquid Limit Test was greater than that of the Dynamic Liquid Limit Test by $2\%\~9\%$. The following equations show the relationship between tile two values. WL, Fall(JIS)=0.961$\cdot$WL, Cas+4.209, WL, Fall(BS)=0.969$\cdot$WL, Cas+5.024, (3) The liquid limit value of BS was greater than that of JIS by $1\%\~6\%$. The following equation shows the relationship between the two values. WL, Fall(BS)=0.976WL, Fall(JIS)+2.638.

Test Gases for Gas Burning Appliances of New Gas Group (새 가스그룹의 가스기기 시험가스)

  • Ha, Young-Cheol;Kim, Sung-Min;Lee, Chang-Eon;Choi, Kyoung-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.439-444
    • /
    • 2011
  • To determine the test gases for gas appliances of new gas group, the interrelation between gas interchangeability, including thermal efficiency, of 13A gas appliances and present 13A test gases was experimentally investigated. The test results show that the Wobbe indices in the case of incomplete combustion and the flame lifting limit gas for the new gas group are respectively 2% higher than the upper limit and 1% lower than the lower limit of the Wobbe index range. The most suitable composition of R gas is 96 mol% of methane and 4 mol% of propane; LNG could be also used as R gas. Further, analysis results showed that the hydrogen concentration of flash back limit gas could be lowered from 30 vol% to 23 vol%.

A Study on the Static Test of Rudder Control System for a Basic Trainer (기본훈련기 방향타 조종장치 정적하중 시험에 관한 연구)

  • Jeon, Chan-Won;Lee, Su-Yong;Gang, Gyu-Seop
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.115-121
    • /
    • 2002
  • This report summarized the static test of the rudder system for the KTX-1 basic trainer. The test loads are applied up to the limit and ultimate loads in a stepping sequence. Test loads and test results matt the strength and stiffness requirements of the rudder control system.. Using #004 full scale structure test airframe.

Evaluation on Ground Characteristics of Weathered Granite Masses by Pressuremeter Test (공내재하시험에 의한 화강 풍화암의 지반 특성 평가)

  • Lee, Kwang-Hee;Bae, Kyung-Tae;Chang, Seo-Man;Lee, Chong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.831-838
    • /
    • 2004
  • To study on mechanical characteristics of weathered granite masses are difficult because of undisturbanced sampling and in-situ test. Generally, pressuremeter test is widely used to investigate the behavior of weathered rock masses. However, it has many problems to get a limit pressure because of cavity collapse, membrane damage, ete. This study aims to evaluate the mechanical characteristics of weathered granite masses using in-situ pressuremeter test and numerical analysis depending on the ratio of length and diameter of the membrane(L/D=5, 8, 10, 15, 20). Test results and data are shown that strength parameters are reduced exponentially varing weathering degree, and numerical analysis results are approximately coincided with the test results. And the ratio of length and diameter of the membrane arc not affected the parameters such as modulus of pressuremeter, shear modulus, etc. But limit pressure is increased decreasing membrane length based on numerical analysis. On the other hand, increasing the membrane length, yield pressure is decreased and plastic radius is increased in the case of same weathering degree.

  • PDF

The Measurement of the Explosion Limit and the Minimum Oxygen Concentration of Gasoline According to Variation in Octane Number (옥탄가 변화에 따른 가솔린의 폭발한계 및 최소산소농도 측정)

  • Kim, Won-Kil;Kim, Jung-Hun;Ryu, Jong-Woo;Choi, Jae-Wook
    • Korean Chemical Engineering Research
    • /
    • v.55 no.5
    • /
    • pp.618-622
    • /
    • 2017
  • Gasoline is a widely used product as a source for energy in homes, the automotive industry, and for industrial power generation, and it is also a product with a high risk of fire and explosion. In this study, to examine the risk for explosion for gasoline, PG, MG and RG, which are categorized according to octane number, were used as test specimens to measure their explosion limit according changes in oxygen concentration. The explosion limit for 21% oxygen concentration in air were confirmed to be 1.5~10.9%, 1.4~8.1%, and 1.3~7.6%, respectively, and the MOC for each of the test sample were confirmed to be 10.9%. The explosion limit measured in the test performed in this study confirmed between a 1.2%~7.6% wider explosion limit for the currently accepted MSDS for gasoline, and therefore it is considered that the results of this study can provide significant reference for preventing fires and explosions for process used gasoline.

Evaluation of Soil Properties using Pressuremeter Test (공내재하시험을 이용한 지반정수 평가)

  • 한상연;장서만;전성곤;이종규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.175-182
    • /
    • 2001
  • The PMT test results are compared with other in situ test such as Standard Penetration Test (SPT), Cone Penetration Test (CPT), Field Vane Test (FVT) and the laboratory test in order to investigate the correlationships for the strength parameters obtained from Busan and Incheon areas. Many proposed correlation formulas also make a comparative study and new correlation formulas for domestic soils are introduced. Limit pressure ( $P_1$) could be determined by P-log($\Delta$V/V) and Relative volume Method. PMT for the granular soils showed relatively high correlation with SPT, while CPT has good correlation with PMT for cohesive soil. The predicted undrained shear test ( $S_{u}$) by the PMT test results for Incheon and Busan samples showed low correlativity with proposed equations, therefore, new correlation formulas are proposed for domestic soils.s.

  • PDF

A Study on the Consistency Measurement of Weathered Granite Soil (화강암질풍화토(花崗岩質風化土)의 Consistency 측정(測定)에 관한 연구(硏究))

  • Kang, Yea Mook;Cho, Seung Seup;Hong, Soon Pil
    • Korean Journal of Agricultural Science
    • /
    • v.7 no.2
    • /
    • pp.109-118
    • /
    • 1980
  • This test was carried out to present criterion to measure the liquid limit of weathered granite soil by using the flow-table method whose operation is easier and more convenient than slump test. The results are as follows. 1. Since liquid limit of weathered granite soil depends upon the particle size distribution, weatheredness and content of colored minerals, maximum particle size should be prescribed when the testing rule of liquid limit by flow-table method is enacted. 2. If take the averaged water content as liquid limit where the height and width of flow are 1 cm respectively by 10 times dropping, this liquid limit is slightly less than the one by slump test. The differance of liquid limit between flow table method and slump test is about 10%. 3. Correlation curves of flow width-water content and flow hight-water content show similar shapes. Those are straight lines in semi-logarithm paper just as liquid limit test. 4. This flow-table method is more convenient and has less personal error of measurement than slump test does. So flow-table method would be favourably utilized for judging the engineering properties of soil.

  • PDF

Analysis on Application of Limit State Design Method for Bridge Evaluation Considering PSC Beam Bridge Experiment Results (PSC Beam교의 실측실험을 반영한 한계상태설계법 기반 교량 평가법 적용 분석)

  • Kim, Kyunghyun;Yoo, Minsun;Paik, Inyeol;Shin, Soobong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.235-244
    • /
    • 2021
  • This study analyzes the applicability of limit state design method on bridge evaluation by considering the experiment of the existing bridge. The test strength of the member is obtained from the PSC beam bridge experiment. The test strength is compared with the calculated strength obtained from the statistical characteristics of material test strength and the two values are almost the same. The response modification factor and dynamic impact factor are obtained from the vehicle loading test. The rating factor is calculated by applying limit state design method as well as current evaluation method and the results are compared. The reliability index of the test bridge is calculated by using the statistical properties of the member strength obtained from material test and simulation. When the statistical properties of the PSC beam tested in this study are applied, the reliability index with a larger value was obtained than the reliability index obtained with the statistical properties of the design code.

Correlation between Casagrande Test and Fall Cone Test Methods and their Applicability in Ground Improvement (카사그란데방법과 원추관입시험방법의 상관관계와 지반개량제의 적용성에 대한 연구)

  • Ko, Kun-Woo;Yeo, Dong-Jun;Kim, Kyung-Min;Lee, Byung-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.2
    • /
    • pp.5-17
    • /
    • 2023
  • In this study, a classification and uniaxial compression test of soil was conducted on 15 collapsed sites to use ground improvement with excellent protection effect owing to the increase of localized heavy rain in Korea. The Casagrande method and fall cone test were performed on the field soil to derive an expression for comparing liquid limit and plastic limit values, soil classification, and correlation between each other. By deriving the optimal mixing ratio of the ground improvement agent using uniaxial compressive strength for each soil classification, the classification of the fine-grained soil was not clear owing to the proficiency difference and test error. However, after classifying using the fall cone test, it was possible to suggest a clear optimal mixing ratio.