Development of Ozone Generator with using DC Voltage for Swinery (돈사 적용용 DC전압을 이용한 오존발생장치 개발에 관한 연구)

  • 문승일;채재우;이대엽;장기현;정태균
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.77-84
    • /
    • 2003
  • HS, Ammonia, CH$_4$, VOCs, Microorganism, Bacteria etc produced from swineries or henhouses are known to prevent the growth of livestock. Moreover, they give an unpleasant feeling to the workers. In this study, a methodology to remove odors and toxic gases by oxidation of ozone was thus accomplished. However, most ozone generators which use the atmospheric surrounding air have problems of contamination of electrode for discharge. Therefore in this work, a wire-cylinder type plasma reactor with DC voltage has been used both in a laboratory scale test and in the real swinery to solve the existing problems. About 6 cm of electrode gap could decrease the attachment of dusts, humid aerosols and other polymers, which are contained in the air. This compact designed device could produce ozone to oxidize and remove the air pollutants. But the amount of ozone was not large enough to be harmful to human Health. Also, the concentration of ozone was able to be varied by the input voltage. which makes it available for the proposed system to be installed in various kinds of pig houses. With this device, at maximum 43 mg/㎥ (20 ppm) of ozone could be produced at 40 ㎸ input voltage (consumed energy was 0.1 Wh/㎥). A program was also made in this work to calculate the optimum parameters for design of a plasma reactor in wide range of conditions.

Experimental Study on the Flame Stable Region of Natural Gases from Various Producing Districts (산지별 천연가스의 화염 안정영역에 관한 실험적 연구)

  • Lee, Chang-Eon;Hong, Sung-Chang;Jeong, Young-Sik;You, Hyun-Seok;Lee, Seung-Jun;Her, Jae-Young;Hwang, Cheol-Hong
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.69-75
    • /
    • 2007
  • In this study, the difference of flame stability zone for natural gases from producing districts was studied experimentally using a new type of flame stability diagram. The similarity of stable flame zone between a domestic appliance and an interchangeability test(IT) burner is also examined. As a result, the stable flame zones expressed by limits curves of flame lifting and yellow tipping show the similar results in a domestic gas range and IT burner. Furthermore, IT burner can reproduce the flash back phenomena and show the distinct difference of fuel type as the burner diameter is increased. To suggest the new type of flame stability diagram in the respect of fuel interchangeability, the air flowrate and Wobbe fuel flowrate were adopted as axis coordinates. It can be identified that the new diagram can provide the useful information on the difference of flame stability zone, heat input rate and air-fuel ratio when a fuel is altered to other fuels under the identical operating conditions. Finally, the stable flame zones for natural gas of 6 type are compared, and the detailed information to use as the interchangeability fuels of standard natural gas is provided using the new type of flame stability diagram.

  • PDF

A Study on Thermal Characteristics on Polymeric Floorings (고분자물질 바닥재의 열적특성에 관한 연구)

  • Lee, Nae-Woo;Kim, Nam-Seok;Moon, Byoung-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.38-45
    • /
    • 2006
  • Polymeric floorings mainly consisted of PVC are easily decomposed by many kinds of hot environmental factors, then generate hazardous asphyxiate gases and/or toxic gases etc. Therefore the mechanism of decomposition and quantitative toxic indices of products are very important for preventing safety and health disasters, especially in case of confined area. So we have investigated decomposition kinetics, numbers of process involved, toxicity indices of product and so on, using DSC, TGA, FT-IR and Pyrolyzer-GC/MS. The thermal decomposition process of polymeric floorings can be mainly divided by dehydrochlorinated reaction and polyene decomposition step, and activation energies of those are approximately $53.93{\sim}62.42kcal/mol$. Especially lethal concentration($LC_{50}$), fractional effective dose (FED) are calculated by measuring the amount of decomposition product. The values on $LC_{50}$ of sample G are ranged $2,003{\sim}2,019(mg/m^{3})$ in case of sample K and H are $1,877,\;1,998(g/m^{3})$ respectively. Even if the results are estimated by calculation method without animal test and/or clinical demonstration, these values could be very useful data for occupational health, hygiene and safety control.

Characterization of Al2O3 Thin Film Encasulation by Plasma Assisted Spatial ALD Process for Organic Light Emitting Diodes

  • Yong, Sang Heon;Cho, Sung Min;Chung, Ho Kyoon;Chae, Heeyeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.234.2-234.2
    • /
    • 2014
  • Organic light emitting diode (OLED) is considered as the next generation flat panel displays due to its advantages of low power consumption, fast response time, broad viewing angle and flexibility. For the flexible application, it is essential to develop thin film encapsulation (TFE) to protect oxidation of organic materials from oxidative species such as oxygen and water vapor [1]. In many TFE research, the inorganic film by atomic layer deposition (ALD) process demonstrated a good barrier property. However, extremely low throughput of ALD process is considered as a major weakness for industrial application. Recently, there has been developed a high throughput ALD, called 'spatial ALD' [2]. In spatial ALD, the precursors and reactant gases are supplied continuously in same chamber, but they are separated physically using a purge gas streams to prevent mixing of the precursors and reactant gases. In this study, the $Al_2O_3$ thin film was deposited by spatial ALD process. We characterized various process variables in the spatial ALD such as temperature, scanning speed, and chemical compositions. Water vapor transmission rate (WVTR) was determined by calcium resistance test and less than $10-^3g/m^2{\cdot}day$ was achieved. The samples were analyzed by x-ray photoelectron spectroscopy (XPS) and field emission scanning electron microscope (FE-SEM).

  • PDF

Friction and Wear of Nitrogen Incorporated Diamond-like Carbon Films Under a Vacuum

  • Yoon, Eui-Sung;Kong, Hosung;Lee, Kwang-Ryeol;Oh, Jae-Eung
    • Tribology and Lubricants
    • /
    • v.11 no.5
    • /
    • pp.59-65
    • /
    • 1995
  • Tribological behaviors of nitrogen incorporated amorphous diamond-like carbon films were experimentally measured under a vacuum ($3 \times 10^{-5}$ Torr) using a ball (AISI 52100 steel)-on-disk wear-rig. Nitrogen incorporated DLC films were deposited by r.f. plasma assisted chemical vapor deposition method. Mixtures of benzene and ammonia or nitrogen gases were used as the reaction gases for the r.f. PACVD, and Si (100) wafer was used as the substrate. In the tribo-test, effects of DLC film thickness and normal load in friction were measured and discussed. Results showed that friction of nitrogen incorporated DLC films from a mixture gas of benzene and ammonia was lower than that of 100% benzene, specially in the measurement of minimum coefficient of friction. Differences in frictional characteristics of nitrogen incorporated DLC films were explained with the changes in chemical structures of the films. Result also showed that friction of DLC films increased with the sliding contact cycle, which remarkably accompanied with roll-shaped wear debris. Mechanisms and roles of the polymer-like wear debris were presented and discussed.

Orientation dependence of GM-type pulse tube refrigerator (GM형 맥동관 냉동기의 저온부 경사도에 따른 냉각 성능 특성 연구)

  • Ko, Jun-Seok;Kim, Hyo-Bong;Park, Seong-Je;Hong, Yong-Ju;Yeom, Han-Kil;Lee, Chung-Soo;Kang, In-Su;Koh, Deuk-Yong
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.3
    • /
    • pp.48-52
    • /
    • 2012
  • This paper describes experimental study on the orientation dependence of GM-type pulse tube refrigerator with helium and neon as working gas. A pulse tube refrigerator generates refrigeration work with gas expansion by gas displacer in the pulse tube. The pulse tube is only filled with working gas and there exists secondary flow due to large temperature difference between cold-end and warm-end. The stability of secondary flow is affected by orientation of cold-head and thus cooling performance is deteriorated by gas mixing due to secondary flow. In this study, a single stage GM-type pulse tube with orifice valve as a phase control device is fabricated and tested. The fabricated pulse tube refrigerator is tested with two different working gases of helium and neon. First, optimal valve opening and operating frequency are determined with experimental results of no-load test. And then, the variation of no-load temperature as orientation angle of cold-head is measured for two different working gases. Effect of orientation dependence of cold-head as working gas is discussed with experimental results.

Performance Test of Silicone Rubber Membrane by Gas Permeation Method (기체투과에 의한 Silicone Rubber Membrane의 기능성 시험)

  • Lee, Seung-Bum;Hong, In-Kwan
    • Elastomers and Composites
    • /
    • v.33 no.1
    • /
    • pp.37-43
    • /
    • 1998
  • The permeation of gas through polymer membrane at temperatures above its glass transition, generally occurs by a solution-diffusion mechanism. This mechanism is performed by the affinity difference between polymeric materials and gas molecules, and various technologies, such as copolymerization, impregnation and so on, have been researched to improve the affinity of polymeric material for the gases. In this study, permeability and selectivity for some gases were obtained from steady-state rates of gas permeation through silicone rubber membrane which is prepared by supercritical fluid extraction method. The permeability was measured by the volumetric method proposed by Barrer. Permeability was increased generally with temperature and permeation pressure. Silicone rubber membrane shows a higher permeability to $CO_2$ than to $O_2$, $N_2$. This results probably reflect the relatively high solubility of CO_2 in silicone rubber membrane, which is due to the affinity of $CO_2$ molecules. Since separation powers of $CO_2/N_2$, $CO_2/O_2$ were more than 200, and 100, respectively, it is able to separate $CO_2$ from the air, and the optimum temperature and pres-sure was 328.15 K, 60 cmHg respectively. In future, it is possible that the silicone rubber membrane can be used for separation or concentration of $CO_2$ through experiment for mixed gas separation.

  • PDF

Experimental Study on Thermoelectric Generator Performance for Waste Heat Recovery in Vehicles (자동차 배기폐열 회수용 열전발전 시스템의 성능에 관한 연구)

  • Lee, Dae-Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.6
    • /
    • pp.287-293
    • /
    • 2014
  • Internal combustion engines release 30~40% of the energy from fossil fuels into the atmosphere in the form of exhaust gases. By utilizing this waste heat, plenty of energy can be conserved in the auto industry. Thermoelectric generation is one way of transforming the energy from engine's exhaust gases into electricity in a vehicle. The thermoelectric generators located on the exhaust pipe have been developed for vehicle applications. Different experiments with thermoelectric generators have been conducted under various test conditions as following examples: hot gas temperature, hot gas mass flow rate, coolant temperature, and coolant mass flow rate. The experimental results have shown that the generated electrical power increases significantly with the temperature difference between the hot and the cold side of the thermoelectric generator and the gas flow rate of the hot-side heat exchanger. In addition, the gas temperature of the hot-side heat exchanger decreases with the length of the thermoelectric generator, especially at a low gas flow rate.

Design of High Intensity Acoustic Test Facility to Generate Required Sound Pressure Level and Spectrum (설정 음압 및 스펙트럼 재현을 위한 음향 환경 시험 챔버의 기본 설계 변수 선정)

  • 김영기;우성현;김홍배;문상무;이상설
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.867-872
    • /
    • 2002
  • A high intensity acoustic test facility is constructed at Korea Aerospace Research Institute (KARI) by 2003. The reverberant chamber of the facility has a volume of 1,228 cubic meters and shall provide an acoustic environment of 152 dB over the frequency range of 25 Hz to 10,000 Hz. The facility consists of a large scaled reverberant chamber, acoustic power generation systems, gases nitrogen supply systems, and acoustic control systems. This paper describes how the basic parameters of a chamber and power generation systems are controlled to meet the requirement of the test. The volume of a reverberant chamber is controlled by the size of test objects and the reverberant characteristics of a chamber. The capacity of acoustic power generation systems is determined by the energy absorption of a chamber and the efficiency of acoustic modulators. Simple math is employed to calculate the required power of acoustic modulators. Moreover, the paper explains how the distribution of sound pressure level at low frequency is checked by analytical and numerical methods.

  • PDF

Performance test of Vitiated Air Heater with High Temperature and High Pressure I (고온 고압 공기가열기 성능시험 I)

  • Lee, Jungmin;Na, Jaejeong;Hong, Yunky;Kang, Kyungtaik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.301-303
    • /
    • 2017
  • This study is the performance test of the vitiated air heater with high temperature and high pressure. The vitiated air heater to provide hot air about 2000 K was designed, and the performance test is carrying out. The designed vitiated air heater uses methane, oxygen, and mixing air by working gases, and uses mixing air for cooling of the bottom of a mixing head. By this reason, the vitiated ar heater has to be designed with heat-resistance from hot frame, and to be tested for its proof. In this paper the performance of he vitiated air heater is analyzed to some test results.