• 제목/요약/키워드: Test Equipments

검색결과 744건 처리시간 0.024초

HVDC DC CT 선형성 최적화 및 시스템 적용에 대한 연구 (Linearity Optimization of DC CT and a Study on the Application of HVDC System)

  • 최용길;이은재;최호석;이욱화
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.758-763
    • /
    • 2014
  • These days, the advantages of DC power system are consistently stand out in korea that was a small power loss and high stability. Needs of DC power transmission technology is focused In the midst of a smart grid and environment friendly generation technology boom that is needed for next generation technology. Researches and businesses for HVDC(High Voltage Direct Current) system has been began. But, Needs of HVDC equipment and system commissioning technology are not on the rise until now. In particular, South Korea's HVDC technology is after the foot runner of advanced country and company. In addition, There is no experience for equipment verification and commissioning technology. And Experts of HVDC are rare. Who has been fully understood hardware and system as a whole, and identified all the equipment's characteristic. Recently, Academia and industry are recognized a needs of HVDC technology. But it does not received a recognition of technical value. In this paper, introduce issues when we apply the IEEE's verification method for HVDC system, especially DC current measurement system, DC CT(Direct Current Transformer), among the HVDC equipments. And Proposes remedial methods on the issue in order to recognize the necessity that was HVDC equipments's verification and commissioning technology research should be focused on.

항전 비행운용프로그램 검증을 위한 단일 PC 기반 소프트웨어 시험환경 SW 설계 (Design of STE SW Running on a Single PC to Verify Avionics OFP)

  • 차상철;이두환;김정열
    • 한국항공우주학회지
    • /
    • 제46권11호
    • /
    • pp.969-973
    • /
    • 2018
  • 항공전자 비행운용프로그램은 임무컴퓨터에서 실행되면서 각종 항전장비와의 연동을 통해 운용된다. 비행운용프로그램을 검증하기 위해서는 임무컴퓨터와 연동하는 실장비가 탑재된 SIL 또는 STE가 필수적이나 일반적으로 특정 항공기 체계개발 시 사용되는 SIL은 OFP 개발 일정과 상당 부분 중첩되므로 OFP 개발과정 후반부 또는 SW 통합 시점에 SIL이 개발자에게 제공되며 개발과정 중 개발자가 SW를 검증하기 위한 도구가 제공되지 않는 경우가 많다. 대부분의 경우 SIL은 한 세트만 제작하기 때문에 다수의 개발자가 하나의 SIL을 이용해서 SW 검증을 해야 하므로 시험단계에서 병목현상이 발생할 수밖에 없어 개발 일정 준수에 위험요소로 작용한다. 본 논문에서는 실장비가 탑재된 SIL 또는 STE 대신 개발자 PC와 임무컴퓨터만을 이용하여 OFP 기능을 검증할 수 있는 STE SW 설계에 대해 기술한다.

벤트 홀을 통한 격실 내부 압력 하강 시험 결과 분석

  • 옥호남;라승호;최상호;김인선
    • 항공우주기술
    • /
    • 제4권1호
    • /
    • pp.150-161
    • /
    • 2005
  • 발사체의 노즈 페어링 벤트 홀 크기 결정 기법의 정확도를 검증하기 위한 시험을 수행하였다. 한국항공우주연구원 우주비행시험그룹이 보유한 열진공 챔버(Bake-Out Chamber)를 이용하여 챔버 내부 압력을 대기압에서 진공으로 떨어뜨렸으며, 그 속에 다양한 벤트홀이 설치된 모델을 넣고 모델 내외부의 압력 및 온도 변화를 측정하였다. 시험 과정에서 나타난 시험 설비 및 측정 장비의 특성을 검토하고 이들이 얻어진 시험 데이터의 정확도 및 신뢰도에 미치는 영향을 분석하였다. 설비 및 측정 장비의 한계 내에서 최대한의 정확도를 얻을 수 있도록 데이터를 처리하였으며, 이렇게 얻어진 시험 결과로부터 벤트 홀 면적 및 배치에 따르는 영향을 분석하였다.

  • PDF

350km/h 본선 주행시험을 통한 한국형 고속열차 판토그라프의 접촉력 특성 평가 연구 (A Study on the Evaluation of Dynamic Characteristics of the Pantograph for the Korean High-Speed Train through 350km/h Trial Running Test)

  • 이희성;목진용
    • 한국철도학회논문집
    • /
    • 제8권4호
    • /
    • pp.342-347
    • /
    • 2005
  • The Korean High-Speed Train(HSR 350x) had been developed by through 'G7-R&D project' in 1996-2002, and has been testing and evaluating it's reliability on the high-speed line until now. A number of core equipments designed and developed by using domestic technologies were boarded on the HSR 350x. In order to verify the performance of HSR 350x and core equipments such as traction system, brake system and pantograph, sophisticated testing and evaluating procedures should be considered and applied. In this paper, the tested and analysed results about the dynamic characteristics of HSR 350x pantograph are introduced in a view point of the mean contact force and it's variation trend, criterion of current collection, and up-lifting of contact wire when the MSR 350x running up to 350 km/h. Through the test and evaluation, we verified that HSR 350x pantograph had an excellent current collection performance and good dynamic characteristics as it had been designed.

Magnetite-Carbon을 이용한 전자파 흡수형 차폐 시멘트 모르터의 물리적 특성과 차폐효율 (The Physical Properties and Shielding Efficiency of Electromagnetic Wave Shielding Cement Mortar Using Magnetite-Carbon)

  • 박동철;이세현;송태협;심종우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.608-611
    • /
    • 2004
  • As the use of various electronic equipments has been increased recently according to industrialization and information network establishment, concern about electromagnetic wave exposed environment has also been increased. Therefore, this study aims to verify electromagnetic wave absorbing effects of inorganic paint that is made of carbon, electro-conductive materials with regard to its physical characteristics, its electromagnetic wave absorbing rate through a mock-up test for proving its effects in the indoor condition. The results are as follows: The results of running tests on electromagnetic wave absorbing inorganic paints for checking their requirements as painting material such as adherence degree, resistance to fine crack, resistance to washing, alkali-resistance, discoloration-resistance, etc. show that inorganic paints have the physical characteristics meeting the requirements for painting materials. In addition, it shows that the electromagnetic wave absorbing effect, in line with the number of paintings and the thickness of paintings, secures $75\~89\%$ of efficiency. And the mock-up test shows that the electromagnetic wave absorbing effect inside building is directly proportional to the distance from the source of electromagnetic wave such as electronic equipments.

  • PDF

고리원자력 주변 환경방사선 감시를 위한 방사선 측정기의 현장 성능 시험 (Field tests of the radiation detectors for environmental radiation monitoring around KORI nuclear power plants)

  • 최성수;신대용;조규성;하달규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1371-1374
    • /
    • 1997
  • We had developed the on-line environmental monitoring system which has installed around Kori Nuclear Power Plants and will be taken the place of the existing system. The system consists of a main computer and 11 sets of radiation monitoring post equipments. Nal(Tl) scintillation detectro was adopted in addition to ion-chamber detector and implemented with DCU(Dose Conversion Unit) and SCA(Single Channel Analyzer). Compared with the existing system, it has revised feature in the radiation measurements which are detection of artificial radioactivity and 2-ways of the radiatiion detectors. The field test trsults show that the developed radiation detecting equipments can measure environmental radiation withn 5.0% of the theoretical value.

  • PDF

데이터 처리 및 무선통신기능을 갖는 회로차단기 개발 연구 (Development of the Circuit Breaker with Data Processing Function and Wireless-communication Function)

  • 김기현;이상익;신성수;배석명;주남규
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1617-1621
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the circuit breaker which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment is able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the circuit breaker and obtained certification. And we tested the over current, leakage current and arc under the normal condition. This paper will be used to the data for development an cabinet panel which is able to monitor the actual loads.

모바일 이용 가능형 ESMS 기능의 단상 분전반 개발 연구 (Development of Single Phase Cabinet Panel with Electrical Safety Monitoring System by Mobile)

  • 김기현;이상익;신성수;배석명
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.92-96
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the ESMS(electrical safety monitoring system) which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment are able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the ESMS and obtained certification. And we tested the over current, leakage current and arc under the normal condition.

수축형 수차발전기 축진동에 관한 연구(I) (A Study for the Shaft Vibration of the Vertical Type Hydro Electric Power Generator)

  • 이승원
    • 전기의세계
    • /
    • 제13권3호
    • /
    • pp.28-37
    • /
    • 1964
  • It is the intention of this thesis to discriminate and investigate the cause of the shaft vibration of the vertical type hydroelectric power generator with respect to electrical, mechanical and hydraulic aspects, and to analyze the vibration which will occure by the each cause investigated above. In order to test the shaft vibration of No.1 generator in Hwachon, Korea new measurement method and measuring equipments were designed. In practice the shaft vibration of the generator was measured by above equipments and analyzed by the discriminative method. Detailed explanation for the designed measurement method and instruments is presented, and the results which I had tested three times for the generator No.1 in Hwachon power plant are added. As a appendix the mechanism and causes of the thrust bearing's wear and remarks for the runner are written.

  • PDF

170kV GIS용 단로기의 현장 사용 실태 조사 (A Study on the Actual Condition Investigation of the Disconnecting Switchgear of 170kV GIS)

  • 이은석;김종서;천종철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1180-1183
    • /
    • 2003
  • 170kV GIS(Gas Insulated Switchgear) is widely used in large industrial factory-electrical facilities of private use because has many benefits. But Other equipments's failures are occurred by GIS failures and give rise economic problems to user. Therefore we will examine the actual condition of the 170kV GIS-electrical facilities of private use and are able to confirm the distribution characteristic analysis of disconnecting switchgear. In this paper, we presents the actual condition investigation of the disconnecting switchgear of 170kV GIS-electrical facilities of private use by post - failure pattern, inspection method, test equipments and so forth.

  • PDF