• Title/Summary/Keyword: Termination

Search Result 1,169, Processing Time 0.034 seconds

Development of Friction Welded Al to Cn Bimetallic Sleeve for 220kV XLPE Cable Termination & Joint (220kV XLPE CABLE 접속함용 Al-Cu 이종접속슬리브 개발)

  • Kim, Hyun-Ju;Park, Jeong-Ki;Park, Sung-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.93-93
    • /
    • 2010
  • We developed friction welded bimetallic sleeve for 220kV aluminum conductor XLPE cable. Not only friction welded bimetallic sleeve for Termination(EB-A, EB-G) but also friction welded sleeve for Joint of Al to Cu conductor was developed regardless of this project. Generally, friction welded sleeve used to connect Al conductor cable to Cu conductor cable and used for improvement of mechanical property of terminal by offer the copper side of friction welded bimetallic sleeve at the Termination. Connection method for Al-Cu conductor has mainly used friction welding at the solid state, because it is difficult to connect by using conventional welding method. this investigation introduces development of friction welded bimetallic sleeve by friction welding and test result of 220kV Al conductor XLPE cable and accessories using friction welded sleeve.

  • PDF

Thermal Characteristics Analysis by Ambient and Operating Temperature according to the Kinds of Terminations in Underground Power Cable Systems (지중송전케이블 종단접속함 종류에 따른 외기 및 운전온도에 의한 열특성 분석)

  • Jung, Chae-Kyun;Kang, Ji-Won;Lee, Bang-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1154-1160
    • /
    • 2015
  • This paper describes the thermal characteristics of underground power cable system terminations according to the change of ambient temperature as well as operating temperature. Recently, the failure has been gradually increasing in outdoor termination during winter season because the power demand was increased by electricity heating system. The power demand and outdoor temperature is difference between day time and night time. The temperature difference has an influence on conductor extension and shrinkage due to conductor force as well as thermal mechanical characteristics. These phenomena have daily repeated during heating and cooling period of conductors. In these cases, the insulation of outdoor terminations might be degraded by the reduced interface pressure surrounding stress relief cone. Therefore, in this paper, the thermal characteristics are variously analysed by simulation considering power demand and ambient temperature condition during winter season at epoxy type termination as well as slip-on type termination

A Termination Analyzer Including Execution Semantics of Active Rules (능동 규칙의 실행의미를 반영한 종료 분석기)

  • Sin, Ye-Ho;Hwang, Jeong-Hui;Ryu, Geun-Ho
    • The KIPS Transactions:PartD
    • /
    • v.8D no.5
    • /
    • pp.513-522
    • /
    • 2001
  • Active database execute an action of active rule defined in advance which is triggered automatically, whenever an event with the matching event specifications occurs, its condition is evaluated. Because these rules may in turn trigger other rules, the set of rules may be triggered each other indefinitely, Therefore, we propose a termination analysis method to guarantee termination. This proposed method considers composite event as well as rule execution time. Above all, the method not only uses deactivation graph combined to trigger graph for exact analysis, but also improves the complexity of analysis. Also the proposed method enhances accuracy of analysis result.

  • PDF

Reusing Search Window Data and Exploiting Early Termination in Variable Block Size Motion Estimation (가변 블록 크기 움직임 추정 기법에서 탐색 영역 데이터의 재사용과 조기 중단 기법의 적용)

  • Park, Taewook;Hur, Ahrum;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.20 no.1
    • /
    • pp.111-114
    • /
    • 2016
  • In HEVC, motion estimation is performed independently for each variable block size. So it requires several times of search window data, and also it is difficult to exploit early termination. In this paper, a new method is proposed to exploit search window data and early termination in variable block size. When applied to TZS algorithm, it reduces pixel comparison and search window data accesses to 1/3.7 ~ 1/2.9 with negligible image quality degradation.

Did Anti-dumping Duties Really Restrict Import?: Empirical Evidence from the US, the EU, China, and India

  • Choi, Nakgyoon
    • East Asian Economic Review
    • /
    • v.21 no.1
    • /
    • pp.3-27
    • /
    • 2017
  • This paper studied the effects of anti-dumping measures on the imports to investigate whether the trade restriction effect of an anti-dumping duty is dominant. Our results indicate that a 1% increase in the anti-dumping duties decreases the import of the targeted product by about 0.43~0.51%. The actual statistics, however, show that the total import of the targeted products increased by about 30 percent while an anti-dumping duty was in force. That indicates that an anti-dumping duty is just a temporary import relief. This paper also investigated whether an anti-dumping duty is terminated in the case that the injury would not be likely to continue or recur if the duty were removed. The hazards model estimates show that increase in market share, MFN tariff rate, and dumping margin decrease the hazard of termination of an anti-dumping duty, but the increase in value added increases the hazard of termination. Generally speaking, this result indicates that the WTO member countries have regulated the overuse of an anti-dumping measure. The findings of this paper show that there is a country- and industry-wise heterogeneous characteristic in the effect as well as termination of an anti-dumping duty.

Reverse voltage characteristics of 4H SiC Schottky Diode by Edge termination Method (4H 탄화규소 쇼트키 다이오드에서 접합종단기법에 따른 항복전압특성)

  • Cheong, Hui-Jong;Bahng, Wook;Kang, In-Ho;Kim, Sang-Cheol;Han, Hyeon-Sook;Kim, Nam-Kyun;Lee, Yong-Jae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.191-192
    • /
    • 2005
  • The reverse breakdown voltages of 4H-SiC SBD(schottky barrier diode)s with FP(Field Plate) and/or FLR(Field Limiting Ring) as a edge termination, were investigated. The breakdown voltages of SBDs with FP ware investigated varying the overlap width from $1{\mu}m$ to $30{\mu}m$. The maximum average breakdown voltages was 475V. There is no significant changes for the devices with overlap width of between $5{\mu}m\sim30{\mu}m$. It was confirmed that the dielectric breakdown of the thin thermal oxide is main cause of device failure. However, the breakdown voltage of SBD with FLR was 1400V even though the FLR edge termination structure was not optimized.

  • PDF

A Comparative Analysis on Korean Medical and Western Medical Service Usage Tendency of Rotator Cuff Surgery Patients - Using HIRA's Patients Sample Data

  • Khang, Hyun-jin;Lee, Hye-Yoon;Lee, Se-Yeon;Kim, NamKwen;Song, YunKyung
    • The Journal of Korean Medicine
    • /
    • v.42 no.4
    • /
    • pp.133-149
    • /
    • 2021
  • Objectives: To lay the foundation for future research into Korean Medicine treatment for Rotator Cuff repair surgery patients by analyzing Korean Medical and Western Medical service utilization and treatment duration. Methods: Data sampling was performed on 2015's HIRA patient data (confidence level of 97%) to analyze patients' Korean Medical and Western Medical service usage tendency. Sampled groups were divided into two groups: i) Patients who completed their treatment within five months after the rotator cuff surgery (termination group), ii) Patients who were treated for more than five months after the surgery (continuation group). Then the patients' Korean Medical and Western Medical service usage tendency was investigated and information of these patients are arranged. Results: Out of 1,453,486 patients who were gathered for sampling, 2,461 patients in total had gone through rotator cuff repair surgery. The termination group had 517 patients and the continuation group had 541 patients. The proportion of patients who visited a Korean Medicine clinic was lower in the termination group than the continuation group. Conclusion: The continuation group received more treatments (both in Western Medicine and Korean Medicine) and spent more on medical expenses compared to the termination group. Further research is highly recommended for more efficient Western Medicine and Korean Medicine treatments and reduced medical expenditure.

Mutual Authentication and Secure Session Termination Scheme in iATA Protocol

  • Ong, Ivy;Lee, Shirly;Lee, Hoon-Jae;Lim, Hyo-Taek
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.4
    • /
    • pp.437-442
    • /
    • 2010
  • Ubiquitous mobile computing is becoming easier and more attractive in this ambient technological Internet world. However, some portable devices such as Personal Digital Assistant (PDAs) and smart phones are still encountering inherent constraints of limited storages and computing resources. To alleviate this problem, we develop a cost-effective protocol, iATA to transfer ATA commands and data over TCP/IP network between mobile appliances and stationary servers. It provides mobile users a virtual storage platform which is physically resided at remote home or office. As communications are made through insecure Internet connections, security risks of adopting this service become a concern. There are many reported cases in the history where attackers masquerade as legitimate users, illegally access to network-based applications or systems by breaking through the poor authentication gates. In this paper, we propose a mutual authentication and secure session termination scheme as the first and last defense steps to combat identity thief and fraud threat in particular for iATA services. Random validation factors, large prime numbers, current timestamps, one-way hash functions and one-time session key are deployed accordingly in the scheme. Moreover, we employ the concept of hard factorization problem (HFP) in the termination phase to against fraud termination requests. Theoretical security analysis discussed in later section indicates the scheme supports mutual authentication and is robust against several attacks such as verifiers' impersonation, replay attack, denial-of-services (DoS) attack and so on.

An Study on the Cost Allocation Methods for Mobile Access Network in US (미국의 이동망 액세스 구간 비용 처리 방식에 관한 연구)

  • 조은진
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.11a
    • /
    • pp.305-308
    • /
    • 2003
  • It is widely used that a network termination rate is calculated by using a Long Run Incremental Costing model. Interconnection Order issued Ministry of Information and Communication in Korea on December 2002 has declared that termination charges of local, national, payphone, and mobile calls are going to be determined by LRIC costing models after 2004. There are lots of preceding researches on a fixed network costing model for applying to LRIC method but on a mobile network not pretty much of them. Besides, Most important basis of current calculation models for termination charges are access costs to connect subscribers to network such as a local loop. In this paper, we look into being of access costs in mobile network and show the applicable standards for cost allocation of access costs in implementing LRIC costing model.

  • PDF

Electrical Properties of 6.6kV Cable Termination by Mechanical Damage (기계적 손상에 따른 6.6kV케이블 종단부의 전기적 특성)

  • Baek, Seung-Myeong;Choi, JIn-Wook;Kim, Sang-Hyun;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1299_1300
    • /
    • 2009
  • We show results that examine about electrical properties of XLPE insulated 6.6kV cable termination by mechanical damage. The cable used to produce the cable termination is 6/10kV tray XLPE fire retardant electric cable (6/10kV TFR-CV $35SQMM{\times}1C$) which is domestically made. We apply force to XLPE insulator and made mechanical defect using knife. Defected samples go through the withstand voltage test according to the IEEE std. 48 test regulations and lighting impulse (hereunder, IMP) withstand voltage test regulations. Then the effects of the scars shown during the construction process on electric accidents at the end part are analyzed.

  • PDF