• Title/Summary/Keyword: Termination

Search Result 1,176, Processing Time 0.117 seconds

Characteristics of Initiation and Termination of Tibialis Anterior Contraction in Adults With Hemiplegia: A Preliminary Study

  • Chung, Yi-Jung;Lee, Jung-Ah;Shin, Won-Seob;An, Seung-Heon;Lee, Eun-Woo;Jung, Kyoung-Sim
    • Physical Therapy Korea
    • /
    • v.14 no.4
    • /
    • pp.50-57
    • /
    • 2007
  • The purpose of this study was to investigate the relationship between delays in initiation and termination of tibialis anterior contraction through surface electromyographic (sEMG) analysis in adults with hemiplegia and healthy subjects and clinical assessment of lower-limb mobility. EMG activity of 6 long-term survivors of stroke and 5 healthy subjects was recorded during maximal isometric ankle dorsiflexion in 3 seconds beeper signals. It must be done as fast and forcefully as possible. Lower limb mobility was assessed with Modified Emory Functional Ambulation Profile (mEFAP). Delay in initiation and termination of muscle contraction was significantly prolonged in the affected lower limb relative to the unaffected limb. Termination of muscle contraction in the hemiplegic lower limb was significantly delayed than the initiation on the affected sides. Delay in initiation and termination of muscle contraction correlated significantly with a few range of mEFAP. Abnormally delayed initiation and termination of muscle contraction may contribute to hemiparetic lower limb mobility in hemiparetic patients. Consequently, this study showed that abnormal delay of initiation and termination of muscle contraction may contribute to hemiparetic lower limb mobility in adults with hemiplegia. Further studies are needed to demonstrate a treatment effect.

  • PDF

A Study on the Impact Factors for the Difference of Mobile Termination Charges among the Countries (국가간 이동착신접속료 차이의 영향 요인 도출에 관한 연구)

  • Cho, Eun-Jin;Park, Myeong-Cheol;Byun, Jae-Ho;Heo, Tae-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1031-1042
    • /
    • 2009
  • Due to liberalization in the early stage, mobile communications market has grown rapidly in the world. However, some dominant operators set higher termination call charges, and thus the market has been distorted and customer welfare has been reduced a lot. The regulation of mobile termination charges is one of key issues of most regulatory agencies in the world. According to the survey, the level of mobile termination charges are quite different from country to country. Why is it so different? This paper investigated the determinants affecting the mobile termination charges for 28 countries by considering country-specific, industry-specific, and regulatory-specific conditions. We found that some regulatory-specific conditions are the most important factors. The rate of pre-paid contract and period of regulation mostly affect the mobile termination charges.

The design of Ground Flight Termination System for Space Launch Application (위성발사를 위한 지상국비행종단지령장비 설계)

  • Lee, Sung-Hee;Bae, Young-Jo;Oh, Chang-Yul;Lee, Hyo-Keun
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.229-235
    • /
    • 2008
  • The ground flight termination system(GFTS) could be used for the termination of launch vehicle in flight motion when the launch vehicle deviates from the designated route due to the system malfunction or failure as well as the launch vehicle can't be tracked by the ground tracking system. This paper introduces the basic concept and design of the ground flight termination system to be used for KSLV launch mission in NARO space center. In order to design the optimal ground flight termination system for KSLV launch application, the operational concept reflected on the flight trajectory and system characteristics of KSLV launch vehicle should be considered. Moreover the RF link budget analysis, and the analysis for system availability and reliability are done. Based on the analysis above, the each subsystem of ground flight termination to transmit the termination signal in stable is designed for KSLV launch mission.

  • PDF

Termination of mutant T7 RNA polymerases on intrinsic hairpin-independent termination signal (돌연변이 T7 RNA 증합효소의 머리핀 구조가 만들어지지 않는 인자독립형 전사종결 부위에서의 전사종결에 관한 연구)

  • Shin, Ji-Young;Kim, Dong-Hui;Lee, Sang-Soo
    • The Journal of Natural Sciences
    • /
    • v.14 no.1
    • /
    • pp.25-37
    • /
    • 2004
  • T7 RNA polymerase also recognize intrinsic, hairpin-independent termination signal, a conserved 7-base pair sequence (ATCTGTT in the non-template stand) and U-rich sequence downstream of it. These intrinsic, hairpin-independent termination signal were commonly found in PTH and CJ termination sequences. There are two types of mutant T7 RNA polymerases recognizing sensitively(X3, X19, BG8) of insensitively (R173C) the intrinsic termination signals. We determined the T7 transcription activities of these mutants. Compared to wild-type, mutants X4, 19 and BG8 show highly reduced transcription activities (8%, 33%, 34%). On the other hand mutant R173C shows comparable transcription activity of wild-type (112%). Also transcription termination efficiencies at the PTH or CJ termination signals were determined by using mutant RNA polymerases. Temination of mutnats X4, X19 and BG8 are increased compared to wild-type. On the other hadn mutant R173C proceeds through PTH and CJ termination signals.

  • PDF

A Study on Electrical Accident of Distributing Cable Termination with Simulated Badness Construction (평가시공불량을 모의한 배전급 케이블 종단부의 전기적 사고 연구)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun;Kim, Young-Seok;Kim, Sun-Gu;Baek, Seung-Myeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.465-470
    • /
    • 2008
  • This paper introduces experimental investigates of an electrical accident of the distributing cable termination with simulated badness construction. We prepared two termination kites, one is built-up type, the other is heat contraction type. Also, we manufactured cable termination that have simulated defect by badness construction and measured their insulation characteristics such as ac (35kV, 1min) and impulse (95kV, $1.2{\times}50{\mu}s$) withstand test. The influence of defects such as thickness and the gap between stress-con of housing and semi-conductor on insulating properties of the termination have been studied. The thickness decrease of insulator decreases ac breakdown strength. Dielectric breakdown traces of insulator that is damaged by knife displayed other shape. The gap of between housing and semiconductor deteriorates dielectric strength of insulator seriously.

  • PDF

Standardization of Enhanced Flight Termination System in the U.S. (미국의 차세대 비행종단시스템 표준화 동향)

  • Bae, Young-Jo;Oh, Chang-Yul;Lee, Hyo-Keun
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.8 no.1
    • /
    • pp.86-95
    • /
    • 2010
  • Flight termination system(FTS) is used to terminate safely the launch vehicle's flight when it faces an emergency situation by transmitting termination command from ground FTS. RCC standard IRIG tone method has been used widely for FTS commands method in foreign ranges and Naro Space Center, but this method has a weakness for security of command signal. Therefore RCC had studied more secured EFTS standard and chose CPFSK digital modulation method. This paper describes basic concept and types of FTS and FTS types which foreign ranges had applied and describes standardization of EFTS in the U.S. based on RCC EFTS study reports.

  • PDF

A Study on the Resistor Array Networks for the Optimum Termination of a Modified Large TEM Cell (변형 TEM Cell의 최적 종단 처리를 위한 저항 어레이 망 설계에 관한 연구)

  • 이중근;강문수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.2
    • /
    • pp.157-166
    • /
    • 1996
  • This paper presents the optimum termination method of a TEM Cell, which utilizes hybrid distributed termination resistor array networks. Current stream on the septum, and on the terminal end of a TEM Cell is analyzed by numerical analysis. By circuit analysis, the optimum resistor array network is designed based on the result of the analysis, which assures efficient power dissipation, and current stream traveling straight and uniform. Thermovision photos were taken for comparing the conventional termination network on which each resistor is arranged at regular intervals, with the suggested optimum termination network on which each resistor is arranged for current distribution. The comparison of the results of thermovision photos shows a good agreement with those obtained by numerical analysis.

  • PDF

The Effects of Contact Intensity and Relationship Termination Cost as Mediators of Long-Term Relational Retention -Focusing on Relationship between Fashion Retail Store and Customer- (장기적 관계유지의 매개변인으로서 접촉강도와 관계단절비용의 효과 -패션점포와 고객간의 관계를 중심으로-)

  • Ju, Seong-Rae;Chung, Myung-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.7
    • /
    • pp.1107-1118
    • /
    • 2007
  • Relationship marketing research has traditionally focused on the relationship among customer satisfaction, trust, and customer commitment, while assuming that the causal relationship of customer $satisfaction{\rightarrow}trust{\rightarrow}commitment$ is well understand. However, recently many scholars argue that customer satisfaction, trust, commitment can not explain long-term orientation fully, and suggest the need for more extensive researches investigating the determinants of long-term relational retention. The purpose of this study was to explained the relationship development process through the mediation effect of contact intensity and relationship termination cost between customer satisfaction and trust, and between trust and commitment, and an analysis the causal relationship among these variables. The results were as follows. First, the customer satisfaction had both direct and indirect effects on trust mediated by contact intensity. Second, the trust had both direct and indirect effects on commitment mediated by relationship termination cost. Third, the commitment influenced long-term orientation. Finally, the empirical results confirmed that the model add to the concept of mediation with contact intensity and relationship termination cost plays a strong, central role in explaining relationship development process between customer and fashion retail stores.

Effects of Administration of GnRH Alone and Concomitant with PMSG on the Fetus in Pregnant Rats (GnRH를 단독으로 또는 PMSG와 동시에 투여했을 때 임신 랫드의 태아에 미치는 영향)

  • 김영홍;이근우;손창호
    • Journal of Veterinary Clinics
    • /
    • v.19 no.3
    • /
    • pp.322-327
    • /
    • 2002
  • The effect of GnRH alone and concomitant with PMSG on the prevention of implantation. termination of pregnancy, and concentration of plasma progesterone were studied in pregnant rats. GnRH 50, 100 or 200 ug alone and concomitant with PMSG 25 or 50 IU were administered once on day 2 or 9 of gestation, respectively. Rats were autopsied on days 7 or 20. Administration of GnRH on day 2 did not result in the prevention of implantation and termination of pregnancy but resulted in termination of pregnancy administering on day 9. Administration of GnRM concomitant with PMSG on day 2 or 9 resulted in prevention of implantation and termination of pregnancy, but injection of GnRH 50 ug concomitant with PMSG 25 IU on day 9 had only one live fetus. Administration of GnRH alone and concomitant with PMSG on day 2 had no effect on the concentration of plasma progesterone determining on day 7. Administration of GnRH concomitant with PMSG on day 2 resulted in decrease of progesterone level determining on day 20 but GnRH alone was normal level. Administration of GnRH alone and concomitant with PMSG on day 9 resulted in decrease of the concentration of progesterone but was normal concentration administering GnRH 50 ug concomitant with PMSG 25 IU.

Design of Termination Cryostat for HTS Power Cable (고온초전도 케이블 단말용 cryostat 설계)

  • 양형석;김승현;김동락;조승연;김도형;류희석;성기철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.160-162
    • /
    • 2003
  • Termination cryostat for 22.9kV, 1.26kA-class HTS power cable has been designed. The cryostat consists of vacuum vessel, liquid nitrogen vessel, current lead and HTS power cable. The current lead and the HTS power cable are connected in liquid nitrogen vessel cooled by forced-circulation subcooled liquid nitrogen. The maximum total heat load of this cryostat is expected to be 150w. In this paper, the detailed design of the termination cryostat is mentioned.

  • PDF