• 제목/요약/키워드: Terminal velocity

검색결과 151건 처리시간 0.033초

노즐 특성 변화에 따른 미분무수와 화염과의 상호작용에 관한 수치해석 (Numerical Analysis on Interaction between Fire Flame and Water Mist according to the Variation of Nozzle Performance)

  • 배강열;정희택;김형범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2983-2988
    • /
    • 2007
  • In the present study, the numerical investigation on the effects of water-mist characteristics has been carried out for the fire suppression mechanism. The FDS are used to simulate the interaction of fire plume and water mists, and program describes the fire-driven flows using LES turbulence model, the mixture fraction combustion model, the finite volume method of radiation transport for a non-scattering gray gas, and conjugate heat transfer between wall and gas flow. The numerical model is consisted of a rectangular enclosure of $L{\times}W{\times}H=1.5{\times}1.5{\times}2.0m$ and a water mist nozzle that be installed 1.8m from fire pool. In the study, the parameters of nozzle for simulation are the droplet size and the spray velocity. Finally, the droplet size influences to fire flume on fire suppression than spray velocity because of the effect of terminal velocity, and the optimal condition for fire suppression is that the droplet size and the spray velocity are $100{\mu}m$ and 20m/s, respectively.

  • PDF

충돌면과 노즐의 형상이 원형충돌제트에 의한 충돌순음 발생에 미치는 영향 (Effect of Nozzle Configuration and Impinging Surface on the Impinging Tone Generation by Circular Jets)

  • 임정빈;권영필
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.693-700
    • /
    • 2003
  • The effect of the configuration of the nozzle and the impinging surface on the characteristics of the hole-tones has been experimentally investigated. It is found that the plate-tone is a special case of hole-tones, where the hole diameter is zero. The jet velocity range for hole-tones is divided into the low velocity region associated with laminar jet and the high velocity region with turbulent jet. The frequency of the tone is that for the shear layer instability at the nozzle exit or that attainable by a cascade of vortex pairing process with increase of the impinging distance. When the distance is longer than one diameter the frequency decreases to the terminal value near the preferred frequency of the column mode instability, in the range 0.23< $St_d$<0.53, where $St_d$ is the Strouhal number defined by $fd/U_J$, f the frequency, d the nozzle diameter, and $U_J$ the exit velocity. While the convection speed of the downstream vortex, in the present study, is almost constant at low-speed laminar jet, it increases with distance at high-speed turbulent jet. As the frequency increases, the convection speed decreases in the low frequency range corresponding to the preferred mode, in agreement with the existing experimental data for a free jet.

Effects of the Patellar Tendon Strap on Kinematics, Kinetic Data and Muscle Activity During Gait in Patients With Chronic Knee Osteoarthritis

  • Eun-Ji Lee;Ki-Song Kim;Young-In Hwang
    • 한국전문물리치료학회지
    • /
    • 제30권2호
    • /
    • pp.110-119
    • /
    • 2023
  • Background: Osteoarthritis is a common condition with an increasing prevalence and is a common cause of disability. Osteoarthritic pain decreases the quality of life, and simple gait training is used to alleviate it. Knee osteoarthritis limits joint motion in the sagittal and lateral directions. Although many recent studies have activated orthotic research to increase knee joint stabilization, no study has used patellar tendon straps to treat knee osteoarthritis. Objects: This study aimed to determine the effects of patellar tendon straps on kinematic, mechanical, and electromyographic activation in patients with knee osteoarthritis. Methods: Patients with knee osteoarthritis were selected. After creating the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), leg length difference, Q-angle, and thumb side flexion angle of the foot were measured. Kinematic, kinetic, and muscle activation data during walking before and after wearing the orthosis were viewed. Results: After wearing the patellar tendon straps, hip adduction from the terminal stance phase, knee flexion from the terminal swing phase, and ankle plantar flexion angle increased during the pre-swing and initial swing phases. The cadence of spatiotemporal parameters and velocity increased, and step time, stride time, and foot force duration decreased. Conclusion: Based on the results of this study, the increase in plantar flexion after strap wearing is inferred by an increase due to neurological mechanisms, and adduction at the hip joint is inferred by an increase in adduction due to increased velocity. The increase in cadence and velocity and the decrease in gait speed and foot pressure duration may be due to joint stabilization. It can be inferred that joint stabilization is increased by wearing knee straps. Thus, wearing a patellar tendon strap during gait in patients with knee osteoarthritis influences kinematic changes in the sagittal plane of the joint.

X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정 (Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique)

  • 김석;이상준
    • 한국가시화정보학회지
    • /
    • 제4권2호
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF

InSAR-based Glacier Velocity Mapping in the Parlung Zangbo River Basin, Tibetan Plateau, China

  • Ke, Chang-Qing;Lee, Hoonyol;Li, Lan-Yu
    • 대한원격탐사학회지
    • /
    • 제35권1호
    • /
    • pp.15-28
    • /
    • 2019
  • By applying the method of SAR interferometry to X-band synthetic aperture radar (SAR) image of COSMO-SkyMed, detailed motion patterns of five glaciers in the Parlung Zangbo River basin, Tibetan Plateau, in January 2010 have been derived. The results indicate that flow patterns are generally constrained by the valley geometry and terrain complexity. The maximum of $123.9ma^{-1}$ is observed on glacier No.1 and the minimum of $39.4ma^{-1}$ is found on glacier No.3. The mean values of five glaciers are between 22.9 and $98.2ma^{-1}$. Glaciers No.1, No.2, No.4 and No.5 exhibit high velocities in their upper sections with big slope and low velocities in the lower sections. A moraine lake accelerates the speed of mass exchange leading to a fast flow at the terminal of glacier No.3. These glaciers generally move along the direction of decreased elevation and present a macroscopic illustration of the motion from the northwest to the southeast. The accuracy of DEM and registration conditions of DEM-simulated terrain phases has certain effects on calculations of glacier flow direction and velocity. The error field is relatively fragmented in areas inconsistent with the main flow line of the glaciers, and the shape and uniformity of glacier are directly related to the continuous distribution of flow velocity errors.

Optimization fluidization characteristics conditions of nickel oxide for hydrogen reduction by fluidized bed reactor

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Kim, Yong-Ha;Lee, Kwan-Young;Park, Young-Ok
    • Korean Journal of Chemical Engineering
    • /
    • 제35권11호
    • /
    • pp.2321-2326
    • /
    • 2018
  • We evaluated the optimal conditions for fluidization of nickel oxide (NiO) and its reduction into high-purity Ni during hydrogen reduction in a laboratory-scale fluidized bed reactor. A comparative study was performed through structural shape analysis using scanning electron microscopy (SEM); variance in pressure drop, minimum fluidization velocity, terminal velocity, reduction rate, and mass loss were assessed at temperatures ranging from 400 to $600^{\circ}C$ and at 20, 40, and 60 min in reaction time. We estimated the sample weight with most active fluidization to be 200 g based on the bed diameter of the fluidized bed reactor and height of the stocked material. The optimal conditions for NiO hydrogen reduction were found to be height of sample H to the internal fluidized bed reactor diameter D was H/D=1, reaction temperature of $550^{\circ}C$, reaction time of 60 min, superficial gas velocity of 0.011 m/s, and pressure drop of 77 Pa during fluidization. We determined the best operating conditions for the NiO hydrogen reduction process based on these findings.

기계수확을 위한 대추의 물리적 특성 분석 (Physical Properties of Jujube(Zizyphus jujuba Miller) for Mechanical Harvesting)

  • 허윤근;이상우
    • 농업과학연구
    • /
    • 제31권2호
    • /
    • pp.115-122
    • /
    • 2004
  • 본 연구는 대추 수확기 개발을 위한 기초연구로써 수확시기의 대추의탈과력과 종말속도를 구명하기 위하여 대추열매, 잎 및 잎줄기의 물리적 특성과 역학적 특성을 조사 분석하였으며 그 분석결과를 요약하면 다음과 같다. 1.수확시기의 대추열매의 평균 장경, 단경, 부피,무게 및 탈과력은 각각 32.02mm, 23.92mm, $10.0{\times}10^{-6}m^3$, 8.99g, 5.43N으로 나타났다. 2. 대추 열매의 무게가 증가함에 따라 열매의 탈과력은 증가하고, F/W는 감소하는 경향을 나타났다. 3. 대추 잎줄기의 평균 무게는 0.7g 이었고, 잎줄기에 매달린 잎수는 6.6개, 잎줄기 길이는122mm, 줄기부분 및 끝부분의 직경이 각각4.5m, 2.7mm 이었다. 4. 대추 잎의 평균 장 단경은 각각 5.7cm와 3.3cm, 잎면적은 $12.98cm^2$, 무게 및 탈리력은 각각 0.20g 및 4.39N으로 나타났다. 5. 수확시기 대추열매의 무게, 대추잎의 무게 및 대추잎줄기 길이와 종말속도의 상관관계는 매우 낮은 것으로 나타났으나, 대추잎의 면적이 증가하면서 종말속도는 다소 감소하는 결과를 나타났다.

  • PDF

인공 종양대치물을 이용한 사지구제술후의 보행 분석 (Gait Analysis of Patients with Tumor Prosthesis around the Knee)

  • 이상훈;정진엽;김한수;김병성;이한구
    • 대한골관절종양학회지
    • /
    • 제3권1호
    • /
    • pp.18-25
    • /
    • 1997
  • Prosthetic replacement is one of the most common methods of reconstruction after resection of malignant tumor around the knee. Gait analysis provides a relative objective data about the gait function of patients with prosthesis. The purpose of this study was to compare the gait pattern of the patients who underwent limb salvage surgery with prosthesis for distal femur and that of patients with prosthesis for proximal tibia. This study included ten patients (4 males, 6 females, mean age 22.7 years, range 14-36) who underwent a wide resection and Kotz hinged modular reconstruction prosthesis replacement and six normal adult(Control). The site of bone tumor was the distal femur (Group 1) in six patients and proximal tibia (Group 2) in 4 patients. The follow-up period ranged from 15 to 82 months (mean : 33 months). The evaluation consisted of clinical assessment, radiographic assessment, gait analysis using VICON 370 Motion Analysis System. The gait analysis included the linear parameters such as, walking velocity, cadence, step length, stride length, stance time, swing time, single support and double support time and the three-dimensional kinematics (joint rotation angle, velocity of joint rotation) of ankle, knee, hip and pelvis in sagittal, coronal and transverse plane. For the kinetic evaluation, the moment of force (unit: Nm/kg) and power (unit: Watt/kg) of ankle, knee and hip joint in sagittal, coronal and transverse plane. In the linear parameters, cadence, velocity, step time and single support were decreased in both group 1 and group 2 compared with control. Double support decreased in group 2 compared with control significantly(p<.05). In contrast to our hypothesis, there was no significant difference between group 1 and group 2. In Kinematics, we observed significant difference (p<.05) of decreased knee flexion in loading response (G2

  • PDF

측두하악관절내장 환자의 진단분류에 따른 하악운동 특성의 분석 (Analysis of the Mandibular Movements in Patients with Internal Derangement of the Temporomandibular Joint According to Diagnostic Subgroups)

  • 김병연;기우천;최재갑
    • Journal of Oral Medicine and Pain
    • /
    • 제23권1호
    • /
    • pp.21-36
    • /
    • 1998
  • The purpose of this study was analyse the mandibular movements in patients with internal derangement of the temporomandibular joint according to diagnostic subgroups. The author classified patients with internal derangement of the temporomandibular joint into 4 diagnostic subgroups by means of the magnet resonance imagings, and evaluated the clinical signs and the mandibular movements with Mandibular Kinesiograph(MKG) in each subgroups. The mandibular movements, measured in this study, were the types of movement in frontal and sagittal plane, velocities in opening and closing movement, and the opening and closing movement, and the opening and closing velocity pattern. The data were compared between the 5 groups including the normal group. The results were as follows : 1. Pain was more frequently observed in the anterior disc displacement without reduction group than in the anterior disc displacement with reduction group. Sound of joint was more frequently observed in the anterior disc displacement with reduction group, and limitation of mandibular opening movement was more frequently observed in the anterior disc displacement without reduction group. Duration of the anterior disc displacement without reduction group was significantly short compared to that of the anterior disc displacement with reduction group, and duration of the unilateral anterior disc displacement without reduction group was shortest in the experimental group. The frequency of Angle's classifications had not significant correlations between the experimental groups. 2. Active and passive range of the opening movement, maximum protrusive movement, maximum lateral movement toward left side were significantly decreased in the experimental groups compared to the control group, but there was no significant difference in the range of the maximum lateral movement toward right side between the control and experiment groups. In unilateral anterior disc displacement without reduction group, the range of maximum lateral movement toward unaffected side was no significant difference in the range of the maximum lateral movement between toward affected side and toward unaffected side. 3. Maximum opening velocity, maximum closing velocity, average opening velocity, average closing velocity and maximum velocity of terminal tooth contact were significantly decreased in the experimental groups compared to control group. There was no significant difference in maximum opening velocity and maximum velocity of Terminal tooth contact between the subgroups of the experimental group each other, but there was significant difference in maximum closing velocity, average opening velocity and average closing velocity between the subgroups each other. 4. In the frontal plane of the MKG, the frequency of complex deviation type(F-2)pattern was significantly increased in the anterior disc displacement with out reduction group compared to the anterior disc displacement with reduction group and the control group. In the sagittal plane, the frequency of coincident type(S-1)was decreased in the same group. 5. In the maximum opening velocity pattern, the frequency of no-peak type (OV-3)in the unilateral anterior disc displacement with reduction group was significantly increased compared to the control group. The frequency of 1-peak type (OV-1) and 2-peak type (OV-2) was decreased in the anterior disc displacement with out reduction group, but the frequency of no-peak type (OV-3)was increased in the same group. In the maximum closing velocity pattern, the frequency of no-peak type (CV-3) was significantly increased in the anterior disc displacement without reduction group. Compared to the anterior disc displacement with reduction group and the control group. The frequency of 1-peak type (CV-1) and 2-peak type (CV-2) in the anterior disc displacement with reduction group was decreased than that in the control group.

  • PDF

Anti-Sway Control of Container Cranes;Inclinometer, Observers, and State Feedback

  • Kim, Yong-Seok;Hong, Keum-Shik;Sul, Seung-Ki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1365-1370
    • /
    • 2004
  • In this paper, a novel anti-sway control system that uses an inclinometer as a sway sensor is investigated. The inclinometer, when compared with a vision system, is very cheap, durable, and its maintenance is easy. However, it gives almost the same performance. Various observers for estimating the angular velocity of the load and the trolley velocity are presented. A state feedback controller with an integrator is designed. After a time-scale analysis, a 1/4-size pilot crane of the rail-mounted quayside crane is constructed. The performance of the proposed control system was verified with a real rubber-tired gantry crane at a container terminal as well as with the pilot crane constructed. Experimental results are provided.

  • PDF