• Title/Summary/Keyword: Tension-type

Search Result 899, Processing Time 0.031 seconds

Comparison of the Low Potassium Dextran Solution and ET-Kyoto Solution in Rabbit Lung (토끼 폐장 분리관류 모형을 이용한 LPD 폐보존액과 ET-Kyoto 폐보존액의 비교)

  • Lim, Cheong;Kim, Kyung-Hwan;Kim, Young-Tae;Sung, Sook-Whan;Kim, Joo-Hyun
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1159-1166
    • /
    • 1997
  • For Improvement of lung preservation, many tripes of preservation solution were developed and tested. The aim of this study was to compare the effect of the most frequently used extracellular type pieservation solution (Low Potassium Dextran, LPD) with a newly developed trehalose containing extracellular type preservation solution(ET-Kyoto, ETK) on postischemic lung function. Twelve New-Zealand white rabbit lungs were harvested and studied on an isolated, blood-perfused model of lung function after 4 hours of cold ischemia at $10^{\circ}C$ In group I (n=6), lungs were preserved with 100 mL/kg of LPD solution; in group II(n=6), lungs were preserved with 100 mL/kg of ETK solution. A few minutes before flushing with preservation solutions, 20$\mu\textrm{g}$ of PGEI were injected into main pulmonary artery. Functions of the preserved lung were compared with PO2, PA pressure, t acheal air pressure, and drylwet ratio. The pulmonary efferent blood oxygen tension at the end of the 60-minute reperfusion period was higher in group II compacted with group I(486.5 $\pm$ 80.3 mmHg versus $432.5\pm82.9$ mmHg at FiO2 1.0, p-value = NS). The mean pulmonary arterial pressure was similar in both $groups.(33.7\pm2.2$ mmHg versus $35.5\pm2.0$ mmHg, p-value : NS). The peak inspiratory airway pressure was significantly lower in group 11(8.010.6 mmHg versus 11.8 $\pm$ 1.4 mmHg, p-value=0.02) The water content of the lung was lower in group II $(70.2\pm6.9%$ versus 78.5 $\pm6.1%),$ but not significant. These data demonstrate that a newly-developed trehalose-containing ET-Kyoto solution yield equal or slightly superior lung function after reperfusion compared with LPD solution.

  • PDF

Evaluation of Cleanness and Physical Properties of W/O Microemulsion (W/O Microemulsion 세정제의 물성 및 세정성 평가)

  • Lee, Myung Jin;Han, Ji Won;Lee, Ho Yeol;Han, Sang Won;Bae, Jae Heum;Park, Byeong Deog
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.769-777
    • /
    • 2002
  • Using four components - nonionic surfactants, water, hydrocarbon oil and an alcohol as cosurfactant, 12 types of cleaning agents were prepared, and their physical properties such as surface tension, viscosity, electroconductivity and phase stability were measured. As the formulated cleaning agents have low surface tensions(30.5-31.1 dyne/cm) and low viscosities (1.6-7.2 c.p.), they are satisfied with the general physical properties of water-in-oil(W/O) microemulsions for their industrial use. They showed a tendency that their temperature range for stable one-phase microemulsion decreased in accordance with the increase of alcohol/surfactant(A/S) ratio in the formulations. However, the temperature range of one-phase microemulsion was much more affected by hydrophilic lipophillic balance(HLB) value of the nonionic surfactant which increased its temperature range and it increased in accordance with the higher HLB value in the formulations. And the maximum content of water which can keep stable one-phase W/O microemulsion was measured at each sample. In addition, their temperature range for stable one-phase microemulsion was also measured. It was confirmed that the selection of surfactant type was very important for formulating a cleaning agent, since the W/O microemulsion system with the nonionic surfactant of the lower HLB value showed better cleaning efficacy that of the higher HLB value for abietic acid as a soil, which was used for preparing a rosin-type flux. In the formulated cleaning agents with the increase of A/S ratio in the formulations, however, there was no significant difference in cleaning efficacy. It was investigated that the differences of their cleaning efficacy was affected by the change of the condition of temperature and sonicating frequency as important factors in the industrial cleaning. That is, the higher, their cleaning temperature and the lower, their sonicating frequency, the more increased, their cleaning efficacy. Furthermore, using optical instruments like UV/Visable Spectrophotometer and FT-IR Spectrometer, their cleaning efficacy for abietic acid was measured. The removal of soil from the contaminated rinse water was measured by gravity separation method in the rinse bath. As a result, the cleaning agent system having the nonionic surfactant of HLB value 6.4 showed over 85% water-oil separation efficacy at over $25^{\circ}C$. Therefore, it was demonstrated in this work that the formulating cleaning agents were very effective for cleaning and economical in the possible introduction of water recycling system.

A Study on the Correlation Analysis of EEG and Vibraimage due to Auditory and Olfactory Stimulation (청각 및 후각자극에 의한 뇌파(EEG)와 진동이미지기술의 상관성 분석에 관한 연구)

  • Kim, Jung-Min;Kim, Myung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4291-4297
    • /
    • 2015
  • EEG has been used to measure the emotion of amenity and discomfort in the interior space. EEG is limited to the experiment, because it is a equipment of contact type. However, Vibraimage can measure the emotion with a web camera. Because Vibraimage is a equipment of non-contact type, it is more suitable for the interior space than EEG. Therefor, it tries to find a correlation variable between EEG and Vibraimage to measure the human emotions. In this study, it were analyzed correlation of EEG and vibraimage due to variation of loudness 60[dB], 90[dB] and rosemary, jasmine scents. Check the health status of subjects who were selected 3 male students, and the period of this experiment was about months. The condition of the environmental test room was in temperature 25[$^{\circ}C$], relative humidity 50[RH%], air current speed 0.02[m/s] and illuminance 1000[lux]. It were analyzed correlation of twenty-three index of EEG(absolute ${\theta}$, relative ${\theta}$, absolute $S{\alpha}$, relative $S{\alpha}$, absolute ${\alpha}$, relative ${\alpha}$, absolute ${\beta}$, relative ${\beta}$, absolute $\gamma$, relative $\gamma$, absolute $F{\alpha}$, relative $F{\alpha}$, absolute SMR, relative SMR, $SMR/{\theta}$, $SMR+M{\beta}/{\theta}$, absolute $H{\beta}$, relative $H{\beta}$, $H{\beta}/{\alpha}$, absolute $M{\beta}$, relative $M{\beta}$, SEF50, ASEF50) and ten index of Vibraimage(Aggression, Stress, Tension/Anxiety, Suspect, Balance, Charm, Energy, Self regulation, Inhibition, Neuroticism). As a result, I was found that relative ${\gamma}$ index of EEG and neuroticism index of Vibraimage have a high correlation as (${\pm}$).414 and (${\pm}$).424.

Application of Amplitude Demodulation to Acquire High-sampling Data of Total Flux Leakage for Tendon Nondestructive Estimation (덴던 비파괴평가를 위한 Total Flux Leakage에서 높은 측정빈도의 데이터를 획득하기 위한 진폭복조의 응용)

  • Joo-Hyung Lee;Imjong Kwahk;Changbin Joh;Ji-Young Choi;Kwang-Yeun Park
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.17-24
    • /
    • 2023
  • A post-processing technique for the measurement signal of a solenoid-type sensor is introduced. The solenoid-type sensor nondestructively evaluates an external tendon of prestressed concrete using the total flux leakage (TFL) method. The TFL solenoid sensor consists of primary and secondary coils. AC electricity, with the shape of a sinusoidal function, is input in the primary coil. The signal proportional to the differential of the input is induced in the secondary coil. Because the amplitude of the induced signal is proportional to the cross-sectional area of the tendon, sectional loss of the tendon caused by ruptures or corrosion can be identified by the induced signal. Therefore, it is important to extract amplitude information from the measurement signal of the TFL sensor. Previously, the amplitude was extracted using local maxima, which is the simplest way to obtain amplitude information. However, because the sampling rate is dramatically decreased by amplitude extraction using the local maxima, the previous method places many restrictions on the direction of TFL sensor development, such as applying additional signal processing and/or artificial intelligence. Meanwhile, the proposed method uses amplitude demodulation to obtain the signal amplitude from the TFL sensor, and the sampling rate of the amplitude information is same to the raw TFL sensor data. The proposed method using amplitude demodulation provides ample freedom for development by eliminating restrictions on the first coil input frequency of the TFL sensor and the speed of applying the sensor to external tension. It also maintains a high measurement sampling rate, providing advantages for utilizing additional signal processing or artificial intelligence. The proposed method was validated through experiments, and the advantages were verified through comparison with the previous method. For example, in this study the amplitudes extracted by amplitude demodulation provided a sampling rate 100 times greater than those of the previous method. There may be differences depending on the given situation and specific equipment settings; however, in most cases, extracting amplitude information using amplitude demodulation yields more satisfactory results than previous methods.

A study on Palpation of the back-shu points (배유혈(背兪穴) 안진(按診)에 관(關)한 고찰(考察))

  • Hong, Mun-Yeup;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.155-173
    • /
    • 2000
  • The diagnosis in Oriental medicine is done by inspection, auscultation and olfaction, interrogation, four diagnostics of pulse feeling and palpation, and various system of identification like identification according to Qi(vital energy), Xue and body fluids, identification according to fair principles, identification according to principles of Wei, Qi, Ying and Xue, identification according to Sanjiao(the triple heater), identification according to four type physical constitution. Sometimes, symptoms and diagnosis techniques according to symptoms is selectively applied for the diagnosis. Among them the pulse feeling and palpation diagnosis technique using the sense of finger and palm of the hand is divided into feeling of pulse and palpation and pressing maneuver. Pressing maneuver is a diagnosis technique pressing and rubbing the affected part in order to attain data of identification including inside and outside condition of the body with regard to the nature, condition and relative seriousness of disease. There are palpation of the skin, palpation the hand and foot, palpation the chest and the abdomen, palpation shu points in pressing maneuver. The diagnosis of the Back Shu points is a technique to examine the change of disease condition from pressure ache, spontaneous ache, tension, relaxation, solidification revealed through channels and collaterals. I investigates starting disease and an attack of disease of twelve pulse and pulse condition through the study relative to the substance and technique of pressing maneuver, and adjusts diagnosis techniques of a region for acupuncture and matters to be attended. The conclusions are as follows. 1. The Shu or stream points in which pathogenic factors go are important to medical treatment of dormant diseases like bowels disease, cold symptom complex and insufficiency symptom complex. 2. Disease classified by system is diagnosed by the condition of process part like pro-trusion, cave-in, tension, relaxation, pressure ache through palpating the Shu or stream points, that is pressing upward or downward left and right sides of the backbone process by hands. 3. In real clinic pressing maneuver of one's back side is very important to patient's diagnosis treatment. Thus, pressing maneuver of one's back side have to be done without omission. 4. Diagnosis must be accomplished through the perception about the diversity of diagnosis technique of bowels disease, the exact knowledge about pressing maneuver of one's back side for enlargement of treatment range and rising of treatment rate, and pressing maneuver of the Shu or the stream points.

  • PDF

The Influence of High School Students' Entrance Exam Stress on Their Mental Health (대입 준비생의 입시스트레스가 정신건강에 미치는 영향)

  • Lee, Hee-Ja;Park, Yung-Soo
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.8 no.1
    • /
    • pp.43-54
    • /
    • 2007
  • This study aimed at investigating the level of high school students' entrance exam stress and mental health first and also investigating if the entrance exam stress and mental health are related to gender, grade, character type, parenting style and economic status. This is expected to be used as a fundamental data for the development of health education program on high school students' stress and diagnosis of their mental health. To achieve those goals above, the questionnaire was used and the sample consisted of 600 students from general high schools in a large city, C and in a smaller city, A in Chungnam province through questionnaire and the conclusion, which was based on 582 proper questionnaires from the 600 questionnaires, through variable analysis, correlation analysis and multi-regression, is below. First, according to the information provided by respondents, the result showed the relationship between those background variables and the entrance exam stress and mental health level. As the students are more introverted and the parenting style is more authoritative, the entrance exam stress is higher and the mental health level is higher as the parenting style is more authoritative and the economic status is lower. In gender, the entrance exam stress level was high for male students in regard to parents pressure. For female students, it was due to the insufficient free time. In test performance, the good grade group showed high stress level when they don't have enough free time and the poor grade group showed high stress level when they have test tension and poor test performance. In character style, the introverted group showed high stress level in future uncertainty. In parenting style, the authoritative group showed significantly high level in all four sub-factors and there is no significant relationship with the stress level and economic statue. Female students reported higher mental health level than male students in somatization and depression. In academic achievement, the poor grade group showed high level in obsession, fear-anxiety and psychotism. In character style, the introverted group showed high level in sensitivity towards others and depression. And in parenting style, the authoritative group is higher in 9 sub-factors than the other two groups in the factor, economic status. The lower economic status group showed high mental health problem level in this order; in obsession, sensitivity towards others, depression, paranonia and psychotism. Second, the results revealed that there is a significant difference among the groups after comparing and analyzing the relationship between the mental health level according to the three groups, the first, second and third group divided by the degree of entrance exam stress. And the higher the entrance exam stress is, the higher the mental health problem level is. Verification showed that there was obvious difference among the groups. the entrance exam stress was positively correlated with the mental health level. The lack of free time, future uncertainty, test anxiety/poor test performance and parents pressure, these factors, in that order, were correlated with the mental health level. when the prediction variables which influenced on mental health are analyzed, test-anxiety/poor test performance was found to be related to mental health most. And after the factor, test-anxiety, future uncertainty and the lack of free time were listed(ranked), however results did not show any correlation with parents' pressure.

  • PDF

Effects of Encapsulation Layer on Center Crack and Fracture of Thin Silicon Chip using Numerical Analysis (봉지막이 박형 실리콘 칩의 파괴에 미치는 영향에 대한 수치해석 연구)

  • Choa, Sung-Hoon;Jang, Young-Moon;Lee, Haeng-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Recently, there has been rapid development in the field of flexible electronic devices, such as organic light emitting diodes (OLEDs), organic solar cells and flexible sensors. Encapsulation process is added to protect the flexible electronic devices from exposure to oxygen and moisture in the air. Using numerical simulation, we investigated the effects of the encapsulation layer on mechanical stability of the silicon chip, especially the fracture performance of center crack in multi-layer package for various loading condition. The multi-layer package is categorized in two type - a wide chip model in which the chip has a large width and encapsulation layer covers only the chip, and a narrow chip model in which the chip covers both the substrate and the chip with smaller width than the substrate. In the wide chip model where the external load acts directly on the chip, the encapsulation layer with high stiffness enhanced the crack resistance of the film chip as the thickness of the encapsulation layer increased regardless of loading conditions. In contrast, the encapsulation layer with high stiffness reduced the crack resistance of the film chip in the narrow chip model for the case of external tensile strain loading. This is because the external load is transferred to the chip through the encapsulation layer and the small load acts on the chip for the weak encapsulation layer in the narrow chip model. When the bending moment acts on the narrow model, thin encapsulation layer and thick encapsulation layer show the opposite results since the neutral axis is moving toward the chip with a crack and load acting on chip decreases consequently as the thickness of encapsulation layer increases. The present study is expected to provide practical design guidance to enhance the durability and fracture performance of the silicon chip in the multilayer package with encapsulation layer.

Successful 20 hours Canine Allograft Preservation with new Solution Containing Triiodothyronine - Development of new lung preservation solution II - (삼요드티로닌을 포함한 폐보존액을 이용한 20시간 폐보존 - 새로운 폐 보존액의 개발 II -)

  • 성숙환;김영태;김주현
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.413-421
    • /
    • 1999
  • Background: Ischemia reperfusion injury is known to contribute to the major causes of the early graft failure in lung transplantation. Triiodothyronine (T3) has been suggested to ameliorate ischemia reperfusion injury from both in vivo and in vitro experiments of various organs. Prospecting its beneficial effect for pulmonary allograft preservation, we made a new solution by adding T3 into the extracellular type dextran solution. Material and Method: Twelve adult mongrel dogs underwent left lung allotransplantation. Six donor dogs were flushed with the new solution(Group 1, n=6), and the remaining six were flushed with Euro-Collins solution to serve as controls(Group 2, n=6). Allografts were stored in each preservation solution for 20 hours at 4$^{\circ}C$. Left single lung transplantations were performed. The right pulmonary artery and the right main bronchus were clamped at 15 minutes after the reperfusion and maintained throughout the experiment to evaluate the transplanted left lung function. Result: Arterial carbon dioxide tension was better in group 1 than in group 2 throughout the experiment period and the difference was statistically significant at 2 hours after reperfusion(28.0${\pm}$3.0 mmHg and 53.1${\pm}$17.4 mmHg, p<0.05). The differences of arterial oxygen partial pressure, peak airway pressure and pulmonary vascular resistance showed no statistical significance. The malondialdehyde(MDA) level, measured from tissue obtained at 120 minutes after reperfusion showed no statistically significant difference. The tissue wet/dry ratio of group 1(649${\pm}$27 %) was significantly lower than that of group 2(686${\pm}$71 %, p<0.05). The microscopic examination revealed varying degrees of injury represented mainly by findings such as perivascular neutrophil infiltration, capillary hemorrhage and interstitial congestion. These findings were less severe in group 1 than those in group 2. Conclusion: The new solution demonstrated superior allograft preservation after 20 hour ischemia compared to Euro-Collins solution in canine single left lung transplantation model, these results suggest that T3 might be a promising agent for pulmonary allograft preservation.

  • PDF

A Study of the Distinctive Characteristics of Government Funded Research Institutes Engaged in Technological Cooperation with SMEs (중소기업의 기술협력에서 출연연의 차별적 특징에 관한 연구)

  • Jun, Seung-pyo;Park, Hun;Yoo, Jae Young
    • Journal of Korea Technology Innovation Society
    • /
    • v.20 no.3
    • /
    • pp.607-641
    • /
    • 2017
  • Recently, there has been an increase in government-wide demand for technological cooperation between government funded research institutes (GFRIs) and small and medium-sized enterprises (SMEs), while there remain a tension between positive and negative views regarding the support given by GFRIs to encourage the technological innovation of SMEs. Although preceding studies have found that the support given by GFRIs to SMEs tends to have the effect of enhancing the technological innovation outcomes of SMEs, this study examines the question of why the agent that provides technological cooperation to SMEs should be limited to GFRIs. To answer this question, in this study, we first examined the qualitative changes in the external technological cooperation behavior of SMEs over time, from 2007 to 2014. Next, we performed cluster analysis to examine whether there were distinctive characteristics of SMEs that engage in technological cooperation with GFRIs, compared to the various other alternatives available as technological cooperation partners for SMEs. Lastly, to help us identify the characteristics of the companies that technologically cooperate with GFRIs and to facilitate the administrative or practical effort to find companies that would be strong candidates for technological cooperation with GFRIs, we used discriminant analysis to define a discriminant formula for such companies likely to engage in technological cooperation. The results of this study were as follows. First, GFRIs were the most competitive -- as demonstrated by the highest level of satisfaction, etc. - compared to the other alternatives for external technological cooperation available to SMEs. This confirmed the necessity for GFRIs to provide technological cooperation to SMEs. Secondly, the issue of whether the small and medium-sized enterprise had engaged in technological cooperation specifically with GFRIs was found not to be a very significant factor in distinguishing these companies. It was found, however, that SMEs engaged in technological cooperation were distinctive, regardless of the type of institution involved in the technological cooperation. Thirdly, SMEs that were in technological cooperation with GFRIs had the characteristics of being already active in joint research and already familiar with utilizing the systems available for governmental support. The findings of this study offers various insights relevant to establishing national R&D strategies using GFRIs and improving the efficiency of policies and administrative practices intended to help GFRIs assist SMEs.

Patterns of Retear After Repair of the Rotator Cuff - MRI Analysis of 109Cases - (회전근 개 봉합술 후 발생한 재파열의 양상 - 109예의 자기 공명 영상 검사 분석 -)

  • Tae, Suk-Kee;Kim, Young-Sung;Lee, Ho-Min;Park, Pan-Kun
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.1
    • /
    • pp.16-24
    • /
    • 2012
  • Purpose: This study was designed to investigate the rate of incidence, location and the clinical value of the rotator cuff retear by analyzing MRI scans, which was taken after an arthroscopic rotator cuff repair. Materials and Methods: This study included a total of 109 patients, who underwent a shoulder MRI scan after an average of 10.6 months later from the arthroscopic rotator cuff repair. We only defined the 'retear' when the Sugaya type IV and V was observed in the sagittal section of the MRI. The location of the retear was divided into the medial and lateral areas by the site, which was 1 cm medial to the anchor insertion. We investigated the incidence rate and the location of the retear, in terms of the age, sex, initial tear size and the suture method. Also, we compared the functional score of the retear group and the non-retear group, after an average of 13.9 months follow-up. Results: There were 38 of the 109 patients that showed the rotator cuff retear. Of these patients, 25 were male patients, and 13 were female patients. Of the 38 patients with the rotator cuff retear, 21 patients were included in the <3 cm retear group, and 17 were included in the ${\geqq}3$ cm retear group. At the end of the follow up period, all 109 patients showed a statistical significant improvement in the shoulder functional score. Conclusion: According to the follow up of the MRI scan, which was taken after the rotator cuff repair, the retear rate reached 34.9 %, and there were no significant differences on the age and the suture method. More rotator cuff retear occurred in male patients, and the initial tear size was positively correlated with the incidence rate of the rotator cuff retear. Also, the retear was more frequently observed at the medial side. That is because when the suture was performed, excessive tension was loaded on the medial side of the suture site.