• Title/Summary/Keyword: Tendon transfer

Search Result 94, Processing Time 0.03 seconds

Tendon Transfer with a Microvascular Free Flap in Ijured Foot of Children (건 이전술 및 유리피편 이식술을 이용한 소아 외상성 족부 손상의 재건)

  • Hahn, Soo-Bong;Lee, Jin-Woo;Jeong, Jae-Hun
    • Archives of Reconstructive Microsurgery
    • /
    • v.5 no.1
    • /
    • pp.112-120
    • /
    • 1996
  • We peformed tendon transfer with a microvascular free flap for recovery of handicapped function and reconstruction for the skin and soft tissue loss. We review the clinical data of 11 children who underwent these operation due to injured foot by pedestrian accident from January, 1986 to June, 1994. The mean age of patients was 5.6 years old(3-8). Five cases underwent tendon transfer and microvascular free flap simultaneously. Another 6 cases underwent operations separately. The time interval between tendon trasnfer and microvascular free flap was average 5.6 months(2-15 months). The duration between initial trauma and tendon transfer was average 9.6 months(2-21 months). The anterior tibial tendon was used in 6 cases. Among these, the technique of splitting the anterior tibial tendon was used in 5 cases. The posterior tibial tendon was used in 3 cases and the extenosr digitorum longus tendon of the foot in 2 cases. Insertion sites of tendon transfer were the cuboid bone in 3 cases, the 3rd cuneiform bone in 3 cases, the 2nd cuneiform bone in 1 case, the base of 4th metatarsal bone in 1 case, and the remnant of the extensor hallucis longus in 3 cases. The duration of follow-up was average 29.9 months(12-102 months). The clinical results were analysed by Srinivian criteria. Nine cases were excellent and 2 cases were good. The postoperative complications were loosening of the tranferred tendon in 2 cases, plantar flexion contracture in 1 case, mild flat foot deformity in 1 case and hypertrophic scar in 2 cases. So we recommend the tendon transfer with a microvascular free flap in the case of injured foot of children combined with nerve injury and extensive loss of skin, soft tissue and tendon.

  • PDF

Monitoring of tension force and load transfer of ground anchor by using optical FBG sensors embedded tendon

  • Kim, Young-Sang;Sung, Hyun-Jong;Kim, Hyun-Woo;Kim, Jae-Min
    • Smart Structures and Systems
    • /
    • v.7 no.4
    • /
    • pp.303-317
    • /
    • 2011
  • A specially designed tendon, which is proposed by embedding an FBG sensor into the center king cable of a 7-wire strand tendon, was applied to monitor the prestress force and load transfer of ground anchor. A series of tensile tests and a model pullout test were performed to verify the feasibility of the proposed smart tendon as a measuring sensor of tension force and load transfer along the tendon. The smart tendon has proven to be very effective for monitoring prestress force and load transfer by measuring the strain change of the tendon at the free part and the fixed part of ground anchor, respectively. Two 11.5 m long proto-type ground anchors were made simply by replacing a tendon with the proposed smart tendon and prestress forces of each anchor were monitored during the loading-unloading step using both FBG sensor embedded in the smart tendon and the conventional load cell. By comparing the prestress forces measured by the smart tendon and load cell, it was found that the prestress force monitored from the FBG sensor located at the free part is comparable to that measured from the conventional load cell. Furthermore, the load transfer of prestressing force at the tendon-grout interface was clearly measured from the FBGs distributed along the fixed part. From these pullout tests, the proposed smart tendon is not only expected to be an alternative monitoring tool for measuring prestress force from the introducing stage to the long-term period for health monitoring of the ground anchor but also can be used to improve design practice through determining the economic fixed length by practically measuring the load transfer depth.

Management of the paralyzed face using temporalis tendon transfer via intraoral and transcutaneous approach Temporalis tendon transfer

  • Choi, Ji Yun;Kim, Hyo Joon;Moon, Seong Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.24.1-24.6
    • /
    • 2018
  • Temporalis tendon transfer is a technique for dynamic facial reanimation. Since its inception, nearly 80 years ago, it has undergone a wealth of innovation to produce the modern operation. Temporalis tendon transfer is a relatively minimally invasive technique for the dynamic reanimation of the paralyzed face. This technique can produce significant and appropriate movement of the lateral oral commissure, more closely mimicking the normal side. The aim of this article is to review the technique of temporalis tendon transfer involving transferring of the coronoid process of the mandible with the insertion of the temporalis tendon via intra-oral and transcutaneous approach.

Proximal Flexor Hallucis Longus Tendon Transfer for the Ossification of the Achilles Tendon (A Case Report) (근위 장 무지 굴근건 이전술을 이용한 아킬레스건 골화증의 치료(1예 보고))

  • Kim, Hyong-Nyun;Jo, Min-Young;Park, Yong-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.110-113
    • /
    • 2011
  • Ossification of the Achilles tendon is a rare condition that is characterized by the presence of an ossific mass contained within the substance of the tendon. The ossified mass is usually asymptomatic but when it grows large and painful, it deteriorates the function of Achilles tendon. We report a case of ossification of the Achilles tendon, which was successfully treated by removal of the ossific mass and proximal flexor hallucis longus (FHL) tendon transfer.

Treatment of Old Achilles Tendon Rupture using Modified Flexor Hallucis Longus Tendon Transfer (변형된 장 족무지 굴건 이전술을 이용한 진구성 아킬레스 건 파열의 치료)

  • Kim, Hyong-Nyun;Suh, Il-Woo;Park, Yong-Wook
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.133-137
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the clinical results of the old Achilles tendon rupture treated with modified flexor hallucis longus (FHL) tendon transfer. Materials and Methods: Seventeen patients with old Achilles tendon rupture treated with modified FHL tendon transfer between March 2004 and February 2008 were enrolled in this study. Technically FHL was pass through the distal portion of the ruptured tendon instead of the drilled hole made on the calcaneus. The mean age of the patients was 37 years (range, 22~67 years), mean follow-up period was 28 months (range, 12~30 months). Patients' subjective satisfaction, calf circumferential diameter, range of motion of ankle and AOFAS ankle-hind foot score and Arner-Lidholm score was evaluated. Results: The average gap between the ruptured tendon was 52 mm (range, 47~56 mm). The AOFAS score improved from 47 pre-operatively to 91 points at the last follow-up. Sixteen patients were satisfied with the result free from discomfort, a patient had mild discomfort who had DM. fourteen patients had decreased range of motion less than 5 degrees while 2 patients had more than 7 degrees decrease compared to the intact side but had no discomfort in daily activities. Nine patients had less than 1 cm calf circumferential diameter difference and 7 patients had 1 to 3 cm diameter difference compared to the intact side. One who had more than 3 cm diameter difference had deteriorated muscle strength. Conclusion: Modified FHL tendon transfer can be a useful technique for the treatment of old Achilles tendon rupture when the gap is with large gap placed too proximal.

  • PDF

Arthroscopic-assisted Latissimus Dorsi Tendon Transfer for the Management of Irreparable Rotator Cuff Tears in Middle-aged Physically Active Patients

  • Lim, Tae Kang;Bae, Kyu Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • Background: Latissimus dorsi (LD) tendon transfer is used as a treatment option for massive irreparable posterosuperior rotator cuff tears, and recently, an arthroscopic-assisted technique was introduced. This study was undertaken to evaluate the clinical and radiological outcomes of arthroscopic-assisted LD tendon transfer for the management of irreparable rotator cuff tears in active middle-aged patients. Methods: The records of five patients (two males) with irreparable tears involving the supraspinatus and infraspinatus tendons managed by arthroscopic-assisted LD tendon transfer were retrospectively reviewed. Clinical outcomes were assessed using the visual analogue scale (VAS) pain scale, American Shoulder and Elbow Surgeon's (ASES) scores, the University of California Los Angeles (UCLA) scale, and ranges of motion. Postoperative integrities of transferred tendon were evaluated by magnetic resonance imaging in 4 patients and by ultrasound in one. Results: Mean patient age was 55 years (range, 48-61 years), and mean follow-up period was 20 months (range, 12.0-27.2 months). Mean VAS score significantly improved from $6.6{\pm}2.6$ preoperatively to $1.8{\pm}2.5$ postoperatively (p=0.009), mean ASES score increased from $67.6{\pm}9.2$ to $84.6{\pm}15.1$, and mean UCLA score from $18.0{\pm}1.4$ to $28.8{\pm}8.5$ (all p<0.001). Postoperative imaging of the transferred LD tendon showed intact repair in 4 patients. The remaining patient experienced LD transfer rupture and a poor outcome. Conclusions: Arthroscopic-assisted LD tendon transfer improved shoulder pain and function in patients with massive, irreparable rotator cuff tears, and may be an option for this condition, especially in physically active patients.

Anterolateral Mini-open Fixation with a Patch Augmentation for Latissimus Dorsi Tendon Transfer in Irreparable Rotator Cuff Tears: Technical Note

  • Kim, Du-Han;Kim, Dong-Hu;Cho, Chul-Hyun
    • Clinics in Shoulder and Elbow
    • /
    • v.18 no.4
    • /
    • pp.269-271
    • /
    • 2015
  • Latissimus dorsi tendon transfer is a well-established method for treatment of irreparable posterosuperior rotator cuff tears. We report on an anterolateral mini-open technique with a porcine dermal patch augmentation for latissimus dorsi tendon transfer. Use of this technique would result in avoidance of deltoid damage by anterolateral mini-open approach and reduction of failure rate by patch augmentation.

Mid-term Clinical and Radiological Outcomes of Latissimus Dorsi Tendon Transfer in Massive Rotator Cuff Tears

  • Suh, Dongwhan;Ji, Jong-Hun;Tankshali, Kirtan;Kim, Eung-Sic
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.4
    • /
    • pp.220-226
    • /
    • 2019
  • Background: This retrospective study was undertaken to evaluate mid-term clinical and radiological outcomes of lattisimus dorsi (LD) tendon transfer in patients with irreparable massive rotator cuff tears (MRCT). We hypothesize that LD tendon transfer would provide safe and satisfactory clinical outcomes at mid-term follow-up. Methods: From November 2008 to December 2016, 23 patients ($57.5{\pm}4.4years$; 20 male, 3 female) who underwent LD tendon transfer for massive tears, were enrolled. Inclusion criteria were irreparable MRCT. Exclusion criteria included full thickness subscapularis tear, rotator cuff arthropathy, anterosuperior rotator cuff tear, and osteoarthritis. Mean follow-up period was $4.7{\pm}4.0years$ (range, 2-12 years). Clinical assessment (American Shoulder and Elbow Surgeons [ASES], University of California, Los Angeles [UCLA], Simple Shoulder Test [SST]) and radiographic assessment (osteoarthritis [OA], acromiohumeral distance [AHI]) were evaluated. Results: ASES, UCLA and SST scores, and range of motion (ROM), except internal rotation, improved significantly at the last followup (p<0.05). Also, AHI was significantly improved at the last follow-up, from 6.6 mm to 8.2 mm (p=0.008). At the final follow-up, the radiologic stages of the glenohumeral osteoarthritis were determined as stage 1 in 9 patients, stage 2 in 10 patients, stage 3 in 2 patients, and stage 4 in 2 patients. Complications were observed in 21.7% cases: 3 re-tears and 2 infections were noted in our study. Conclusions: LD tendon transfer for irreparable MRCT provides satisfactory clinical outcomes at mid-term follow-up. Mild degenerative osteoarthritis (stage 1, 2) of the shoulder joint are common at the mid-term follow-up. Also, complications such as tear, infection should be considered.

An Experimental Study on Transfer Length of Domestic CFRP Tendon (국내 CFRP 긴장재의 전달길이에 관한 실험적 연구)

  • Jung, Woo-Tai;Park, Young-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.303-310
    • /
    • 2009
  • CFRP(carbon fiber reinforced polymer) tendons can be used as an alternative to solve the corrosion problem of steel tendons. Material properties of CFRP tendons such as bond strength, transfer length, and development length should be determined in order to apply to concrete structures. First of all, in case of application for pretension concrete members with CFRP tendons, transfer length is an important factor. A total of 9 beams have been cast to determine transfer length and development length of domestic CFRP tendon in this paper. Test results revealed that transfer length of the prestressing 25% and 50% are 34D, 55D respectively. Also, transfer length has increased as the prestressing force has increased. A change was observed in transfer length of developed CFRP tendon after 9 weeks. ${\alpha}_t$ of developed CFRP tendon was 2.3 similar to the steel strand.

Development of a Computer Graphics-Based Prototype CAD Tool for Planning Tendon Paths in Hand Rehabilitative Surgery (손 재활수술을 위한 힘줄경로 설계용 컴퓨터그래픽스 기반의 프로토타입 CAD 툴 개발)

  • Yoon, In-Mo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.12
    • /
    • pp.3435-3446
    • /
    • 1999
  • The application of Computer Aided Design (CAD) tool to rehabilitative surgery of the hand is a new field of endeavor. It is considered that there are currently no existing systems designed to assist the orthopedic surgeon in planning complex procedures such as tendon transfer operations. Most tendon transfer operations are performed by surgeons on the basis of knowledge and experience gained through years of practice. However, with the help of this computer graphics-based CAD tool for planning tendon paths, the planning and the evaluation for the best operation on patients' hands also may be possible. The purpose of this study was to model kinematically the structure of the hand and design a prototype tendon path planning tool with a standard computer graphics library, in order for surgeons to perform tendon transfer surgery more objectively and quantitatively.

  • PDF