• Title/Summary/Keyword: Tendon system

Search Result 219, Processing Time 0.023 seconds

Anterior Cruciate Ligament Augmentation Using Autogenous Semitendinosus Tendon (자가 반건양건을 이용한 전방 십자 인대 보강술)

  • Choi, Nam-Yong;Han, Chang-Hwan;In, Yong;Moon, Chan-Woong;Choi, Seung-Woog;Jin, Sung-Ki
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.12-17
    • /
    • 2008
  • Purpose: This study presents clinical results of anterior cruciate ligament(ACL) augmentation using autogenous two-strand semitendinosus tendon in the treatment of partial ACL tears with preservation of residual portion. Materials and Methods: From January 2004 to June 2006, twenty two patients who had an ACL injury underwent ACL augmentation using autogenous two-strand semitendinosus tendon were enrolled in this study. We evaluated the clinical results with regard to clinical findings(range of motion, Lachman test, pivot shift test), standard knee scales(Lysholm, Modified Feagin Scoring System), and KT-1000 arthrometer testing. Results: At minimum one year postoperatively, there was no limitation of range of motion. Lachman and pivot shift tests were negative in all knees. On instrumented anterior laxity test by KT-1000 arthrometer, mean side to side difference was improved from 4.6mm preoperatively to 1.7mm postoperatively. Average Lysholm score was improved from 70 to 92. Ninety one percent of cases were rated as good or excellent in Modified Feagin Scoring System. Conclusion: Augmentation using autogenous two-strand semitendinosus tendon with preservation of residual portion of the ACL seems to be an acceptable method for restoring knee stability and proprioceptive function.

  • PDF

Evaluation of Corrosion Resistance with Grout Type and Tendon (그라우트 품질을 고려한 텐던의 부식저항성 평가)

  • Ryu, Hwa-Sung;An, Ki-Hong;Koh, Kyung-Taek;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.76-82
    • /
    • 2018
  • Grout in duct is very effective protection from tendon corrosion in PSC(Prestressed Concrete) structure. In the work, durability and mechanical tests are performed for two types of grout which are conventionally used one and the improved grout with reduced w/c (water to cement) ratio and silica fume. Tendon system with 1000mm height is prepared and various tests including strength, flow, absorption, and bleeding ratio are conducted. ICM(Impressed Current Method) is adopted for corrosion acceleration in tendon with 12.7mm diameter inside grout. For 2 and 4 days, corrosion acceleration is performed for 2 different type of grout and corrosion amount is investigated. The improved grout shows higher compressive strength by 10 MPa and lower absorption ratio by 50% than the conventional one. It also provides an excellent corrosion reduction to 39.8 %~48.2 % for 2~4 days of acceleration period.

Evaluation on the Lost Prestressing Force of an External Tendon Using the Combination of FEM and HGA: II. Experimental Verification and Field Applications (FEM과 HGA의 조합을 이용한 외부 긴장재의 손실 긴장력 평가: II. 실험적 검증 및 현장적용)

  • Jang, Hang-Teak;Noh, Myung-Hyun;Park, Kyu-Sik;Park, Taehyo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.5 s.57
    • /
    • pp.121-132
    • /
    • 2009
  • This paper introduces an experimental verification and a field application of the proposed technique using the combination of FEM and HGA about the loss prestressing force of an exteranl tendon by above same authors. The vibration tests have been conducted by using a laboratory models and the externally prestressed tendon at the field and the natural frequencies are extracted from the vibration tests. The proposed technique based on the extracted natural frequencies is applied. It is seen that the errors in the tension and lost prestressing force by proposed technique are about 4% from a laboratory model test. For the model verification at field, exact modeling has beem made with Rayleigh damping. It is seen that the error in the tension by proposed technique is less than 1% and the estimated lost prestressing force converges less than the exact value.

Embedded EM Sensor for Tensile Force Estimation of PS tendon of PSC Girder (PS 긴장재 긴장력 계측을 위한 PSC 거더 내부 매립용 EM 센서)

  • Park, Jooyoung;Kim, Junkyeong;Zhang, Aoqi;Lee, Hwanwoo;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.691-697
    • /
    • 2015
  • In this paper, an embedded EM sensor was researched to estimate prestressing force of PS tendon in PSC girder. Recent methodologies for managing prestressing force loss were staying on verifying a applying prestressing force under construction, namely the loss management can not be controlled after construction. To estimate the tensile force of PS tendon during lifetime of PSC girder, this research proposed a bobbin-type embedded EM sensor that can be embedded in PSC girder is designed and fabricated considering the shape properties of anchorage zone and sheath. To verify the proposed sensor, a small PSC girder test was performed. The embedded EM sensor was connected to a sheath and anchor block, and the concrete was poured. After curing, the change of the permeability of PS tendon under tensile forces of 200, 710, 1070, 1300kN was measured using embedded EM sensor. The permeability of PS tendon had decreased according to the increment of applied tensile force. Also it is confirmed that the change of permeability due to applied tensile force could resolve the applied tensile force values. As a result, proposed embedded EM sensor could be embed into the PSC girder and it could be used to estimate the tensile force variation during lifetime of PSC girder.

A Study on the Determination of Prestressing Force Considering Frictional Loss in Prestressed Concrete Structures (프리스트레스 콘크리트 구조물의 마찰손실을 고려한 긴장력 산정에 관한 연구)

  • 조병완;이재형;태기호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.645-650
    • /
    • 2000
  • In the prestressed concrete structures, the effective prestressing force of tendon is basically most important item for structural safety and serviceability. The frictional loss is one of the major items for determinating the effective prestressing force and depend on the construction accuracy of the structures. In this thesis, it will be analyzed and found through measured hydraulic jack pressure, tendon elongation and prestressing control system that the tendancy of apparent curvature friction coefficient, the ratio of jacking force and required prestressing force, the ratio of initial jacking force and required prestressing force and compatibility of specified friction loss coefficient. The specified control limit for curvature friction coefficient of prestressing control system is about 0.25 and wobble friction coefficient 0.005. Thus, the control limit should be modified according to changed vale of friction coefficient.

  • PDF

Wireless Impedance Sensor with PZT-Interface for Prestress-Loss Monitoring in Prestressed Concrete Girder

  • Nguyen, Khac-Duy;Lee, So-Young;Kim, Jeong-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.6
    • /
    • pp.616-625
    • /
    • 2011
  • Ensuring the designed prestress force is very important for the safety of prestressed concrete bridge. The loss of prestress force in tendon could significantly reduce load carrying capacity of the structure. In this study, an automated prestress-loss monitoring system for prestressed concrete girder using PZT-interface and wireless impedance sensor node is presented. The following approaches are carried out to achieve the objective. Firstly, wireless impedance sensor nodes are designed for automated impedance-based monitoring technique. The sensor node is mounted on the high-performance Imote2 sensor platform to fulfill high operating speed, low power requirement and large storage memory. Secondly, a smart PZT-interface designed for monitoring prestress force is described. A linear regression model is established to predict prestress-loss. Finally, a system of the PZT-interface interacted with the wireless sensor node is evaluated from a lab-scale tendon-anchorage connection of a prestressed concrete girder.

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.

Seismic performance of prefabricated bridge columns with combination of continuous mild reinforcements and partially unbonded tendons

  • Koem, Chandara;Shim, Chang-Su;Park, Sung-Jun
    • Smart Structures and Systems
    • /
    • v.17 no.4
    • /
    • pp.541-557
    • /
    • 2016
  • Prefabricated bridge substructures provide new possibility for designers in terms of efficiency of creativity, fast construction, geometry control and cost. Even though prefabricated bridge columns are widely adopted as a substructure system in the bridge construction project recently, lack of deeper understanding of the seismic behavior of prefabricated bridge substructures cause much concern on their performance in high seismic zones. In this paper, experimental research works are presented to verify enhanced design concepts of prefabricated bridge piers. Integration of precast segments was done with continuity of axial prestressing tendons and mild reinforcing bars throughout the construction joints. Cyclic tests were conducted to investigate the effects of the design parameters on seismic performance. An analytical method for moment-curvature analysis of prefabricated bridge columns is conducted in this study. The method is validated through comparison with experimental results and the fiber model analysis. A parametric study is conducted to observe the seismic behavior of prefabricated bridge columns using the analytical study based on strain compatibility method. The effects of continuity of axial steel and tendon, and initial prestressing level on the load-displacement response characteristics, i.e., the strain of axial mild steels and posttensioned tendon at fracture and concrete crushing strain at the extreme compression fiber are investigated. The analytical study shows the layout of axial mild steels and posttensioned tendons in this experiment is the optimized arrangement for seismic performance.

Effects of Somatosensory Stimulation on Lower-Limb Joint Kinetic of Older Adult During Stair Descent (계단 하강 보행 동안 체성감각 자극이 노인의 하지 관절 역학에 미치는 영향)

  • Kwak, K.Y.;So, H.J.;Kim, S.H.;Yang, Y.S.;Kim, N.G.;Kim, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.93-104
    • /
    • 2011
  • The purpose of this study was to investigate lower-limb joint torque of the two groups as it changed by somatosensory stimulation during the descent down three stairs of different heights and to describe the difference between the two groups, which are young people group and elderly people group. Subjects of each groups climbed down a stair at four stimulation conditions, which are non-stimulation, tibialis anterior tendon stimulation, achilles tendon stimulation, tibialis anterior - achilles tendon stimulation. Motion capture data were collected using 3D optoelectric motion tracking system that utilizes active infrared LEDs, near infrared sensor and force plate. The obtained motion capture data was used to build 3D computer simulation model. The results show that lower-limb joint torque of the two groups changed with somatosensory stimulation as they descended the stairs and the joint torque of the two groups differed from each other.