• 제목/요약/키워드: Tenax-TA

검색결과 37건 처리시간 0.019초

Comparison on Usefulness of Sampling Methods of Indoles in Airs from Swine Facility by Tenax-TA and SPME

  • Yu, Mee-Seon;Lee, Jae-Chun;Yang, Sung-Bong;Kim, Doo-Hwan;Cho, Sung-Back;Whang, Ok-Wha
    • 한국환경과학회지
    • /
    • 제22권12호
    • /
    • pp.1539-1549
    • /
    • 2013
  • The purpose of this study is to compare the sampling methods for monitoring indoles (phenol, p-cresol, indole and skatole) in airs of swine facility. As the collecting methods of indoles in air, Tenax-TA adsorption tube and solid phase microextraction (SPME) were examined. For the preparation of calibration curves of indoles concentrated in Tenax-TA, the standard indoles solutions were spiked in each of Tenax-TA tubes and thermally desorbed (ATD) into a gas chromatograph combined with mass detector (GC/MS). And for the preparation of calibration curves by SPME, indoles in the standard gaseous solution prepared by evaporating the aqueous solution that contained indoles into a polyester sampling bag were extracted with SPME fiber and subsequently analyzed by the GC/MS. Two sampling methods were evaluated for extracting indoles present in swine building environments. Results indicated that the SPME method using Polydimethylsiloxane/ Divinylbenzene (PDMS/DVB) fiber was more effective than Tenax-TA method in extracting indoles. The gas chromatographic analysis showed that the linearities of calibration curves and detection limits were useful for detection of indoles in swine airs. The field tests also showed that considerably different levels of indoles were present in various parts of the swine building.

환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구 (A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere)

  • 손은성;서영교;이동현;이민도;한진석;백성옥
    • 한국대기환경학회지
    • /
    • 제25권6호
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

흡착관/열탈착 GC/MS 방법에 의한 모사시료 중의 미량 페놀 분석에 관한 평가 (Evaluation of the Measurement of Trace Phenols by Adsorption/Thermal Desorption/Gas Chromatography/Mass Spectrometry (ATD/GC/MS) in Artificial Air)

  • 허귀석;이재환;황승만;정필갑;유연미;김정우;이대우
    • 한국대기환경학회지
    • /
    • 제18권2호
    • /
    • pp.127-137
    • /
    • 2002
  • Phenolic compounds in air are toxic even at their low concentrations. We had evaluated a total of five phenolic compounds (Phenol, o-Cresol, m-Cresol, 2-Nitrophenol and 4-Chloro-3-methylphenol) in artificial air using a combination of ATD/GC/MS. To compare the adsorption efficiency of these phenolic compounds, three adsorbents (Tenax TA, Carbotrap and Carbopack B) were tested. Tenax TA adsorbent was most effective of all the adsorbents used for the efficiency test. Five phenolic compounds were found to be very stable on adsorbent tubes for 4 days at room temperature. Detection limit of five phenolic compounds ranged from 0.05 to 0.08 ppb (when assumed to collect 10 L air). The calibration curve was linear over the range of 22∼ 164 ng. The reproducibility was less than 4%. Sampling of duplicate pairs (DPs) was made to demonstrate duplicate precision and sampling efficiency.

삼림욕 향기 성분 분석 (Analysis of the aromatic components of the forest bathing)

  • 노택우;윤석신
    • 대한화장품학회지
    • /
    • 제17권1호
    • /
    • pp.29-38
    • /
    • 1991
  • As the suitable place of the forest bathing, Two places of the needle-leaf trees, which are located in the Oh-Saek mineral spring near place from the Sorak mountain, were selected. And then, Headspace gas trapping apparatus were setted in that two places and the aromatic components of the forest were adsorbed by Tenax-TA column for 24 hours. And Tenax-TA column were analyzed by the GC SE GC-MS. The analyzed components were found to contain up to between 70-80% of pollutants, which are Toluene, Methyl Chloride, Hexane, p-Xylene, Benzene, ... etc. On the other hand, the aromatic components of the forest, which give aromatheraphitical effectness, are as follow: alpha-Pinene, Limonene, 1, 8-Cin-eol, Benzaldehyde, . . . etc.

  • PDF

반응표면 분석에 의한 볶음들기름의 향기성분 포집조건 최적화 (Optimization of Dynamic Headspace Purge Conditions for Concentration of Volatile Flavor Compounds of Roasted Perilla Seeds Oil by Response Surface Methodology)

  • Kim, Suk-Ju
    • 한국식품영양학회지
    • /
    • 제17권2호
    • /
    • pp.220-228
    • /
    • 2004
  • Tenax-TA와 동적 headspace 향 포집방법을 이용하여 볶음들기름의 향기성분을 농축하였다. 이때 반응표면분석법을 이용하여 Tenax-TA에 결합한 향기성분의 탈착에 의한 손실을 최소화하고 휘발성이 낮은 화합물의 포집 효율을 극대화시키는 최적조건을 결정하였다. 독립변수로 향 포집 온도와 시간 및 시료량을 설정하였고 총 peak 면적, 탈착율, 휘발성이 가장 낮은 화합물인 perilla ketone의 면적을 종속변수로 하였다. 등고선 그림을 겹친 결과 0.6 g의 볶음들기름을 48$^{\circ}C$에서 12분 동안 포집시키는 것이 최적조건이었으며 Tenax-TA에서 탈착되는 주요한 휘발성 화합물은 2-propanone, 2-butanone, acetic acid 및 2-methyl propanal이었다.

GC/MS를 이용한 화재증거물속의 인화성물질 분석에 관한 연구 (Analysis of Ignitable Liquid Residues from Fire Debris Samples with GC/MS)

  • 이성룡;한동훈
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2010년도 추계학술발표회 자료집
    • /
    • pp.148-151
    • /
    • 2010
  • 화재증거물 속의 인화성물질을 분석하는 기술은 현재 다양한 추출 및 농축법을 활용한다. 본 연구에서는 Tenax TA를 이용하여 화재증거물 속의 인화성물질을 농축한 후 자동열탈착 장비를 사용하여 Tenax TA관 속에 농축되어 있는 인화성물질을 자동열탈착시켜 GC로 보낸 후 MS 분석하는 기술을 소개한다. 이러한 전처리과정을 사용하여, 화재증거물속의 인화성물질(경유, 등유 등)을 분석하였는데, 물로 화재증거물을 물을 이용하여 소화하여도, 시간이 오래지난 화재증거물이라도 열탈착 장비를 이용한 분석은 경유, 등유등을 확인하는데 유용하였다.

  • PDF

김해시 동지역 휘발성유기화합물의 지역별 시간에 따른 농도 특성에 관한 연구

  • 봉상훈;박흥재;정성욱;김선영
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2006년도 추계 학술발표회 발표논문집
    • /
    • pp.500-502
    • /
    • 2006
  • 본 연구에서는 김해시 동지역을 중심으로 생활형태별로 상업지역, 주거지역, 도로지역, 공단지역으로 구분하여 Tenax TA로 3시간 간격으로 포집하여 일간 변화를 측정하였다. 이를 GC/MS를 이용하여 정량분석하여 생활형태별 일간 농도변화를 관측하였다. 생활형태별로 휘발성유기화합물의 농도는 도로지역, 공단지역, 상업지역, 주거지역 순으로 나타났으며, 시간에 따른 농도 변화는 오존전구 물질인 휘발성유기화합물의 반응이 빠른 낮시간보다 밤시간에 상대적으로 높게 검출되었다.

  • PDF

마이크로 챔버와 20 L static chamber를 이용한 도어트림 암레스트로부터 방출되는 휘발성 유기화합물 평가 (Evaluation of volatile organic compounds emitted from door-trim armrest using micro chamber and 20 L static chamber)

  • 이익희;유지호;김만구
    • 분석과학
    • /
    • 제24권4호
    • /
    • pp.290-297
    • /
    • 2011
  • 현재 자동차 실내공기질을 평가하는 방법이 ISO, 중국, 일본에서 개발 중에 있으며, 우리나라에서도 관리기준이 2010년 7월 1일 이후 생산한 신규제작자동차부터 적용되고 있다. 자동차 실내공기질을 관리하기 위해서는 자동차 실내의 내장부품으로부터 방출되는 휘발성 유기화합물을 평가하는 것이 중요하다. 이 연구에서는 모듈단위부품인 도어트림 모듈의 구성부품인 도어트림 암레스트를 ISO 12219-5방법에 따라 완제품을 평가 하였으며, ISO 12219-3방법으로 절단부품과 도어트림 구성소재를 평가하였다. Tenax TA가 충진된 스테인리스 튜브를 이용하여 VOC를 채취하여 TD-GC/MS를 이용하여 분석하였다. 두 시험방법을 비교한 결과 도어트림 암레스트로부터 방출되는 물질의 비율이 차이가 있음을 확인하였고, 도어트림 암레스트의 소재를 평가한 결과 PP substrate과 adhesive가 도어트림 암레스트에서 주요 방출원인 소재로 나타났다.

Mulberry Paper Bag μ-Solid Phase Extraction for the Analysis of Five Spice Flavors by Gas Chromatography-Mass Spectrometry

  • Yoon, Ok-Kyung;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.35-42
    • /
    • 2009
  • Headspace micro solid phase extraction using mulberry paper bag (HS-MPB-$\mu$-SPE) has been developed and validated for the analysis of volatile flavor compounds from five spice by gas chromatography-mass spectrometry (GC/MS). HS-MPB-$\mu$-SPE was performed with adsorbent particles enclosed inside a mulberry paper bag. Four different kinds of adsorbents such as Tenax TA, Porapack Q, dimethylpolysiloxane and polyethylene glycol were tested. The extraction solvents compared were petroleum ether, methylene chloride, and chloroform. Better results were obtained when Tenax TA and petroleum ether were used. The limit of detection (LOD) and the limit of quantitation (LOQ) were in the range of 1.3 ng/mL and 4.3 ng/mL, respectively, for o-cymene as a model compound of monoterpene. Proposed method showed good reproducibility (3.3%, RSD) and good recoveries (94.0%). The HS-MPB- μ-SPE is very simple to use, inexpensive, rapid, requires small sample amounts and solvent consumption. Because the solvent for extraction is reduced to only a very small volume (0.6 mL), there is minimal waste or exposure to toxic organic solvent and no further concentration step. This method allows successful characterization of the headspace in contact with the five spice sample. Strong trans-anethole from star anise or fennel is a characteristic flavor of five spice powders. HS-MPB-$\mu$-SPE combined with GC/MS can be a promising technique for the broad spectrum measurement of volatile aroma compounds from solid spices.

Identification of Volatile Organic Compounds in Several Indoor Public Places in Korea

  • Seo, Sooyun;Lim, Soogil;Lee, Kiyoung;Seo, Young-Kyo;Baek, Sung-Ok
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권4호
    • /
    • pp.192-201
    • /
    • 2014
  • A comprehensive profile of volatile organic compounds (VOCs) in public spaces is needed for interpreting indoor air measurements. Seasonal differences in profiles are critical for epidemiological study and risk assessment. The purposes of this study were to establish profiles for individual VOCs in 50 indoor public places in Korea and to determine seasonal variations in their concentrations. Air samples were taken during working hours. Seventy-two of the 91 targeted VOCs were identified using multiple standards. Six VOCs detected in all summer and winter samples were toluene, acetone, m,p-xylenes, ethylbenzene, benzene, and styrene. In summer, methyl ethyl ketone and 1-butanol were also found in all samples. In both seasons, the dominant indoor VOCs were toluene, m,p-xylenes, ethylbenzene, acetone, and isopropyl alcohol. Other chemicals associated with gasoline emissions were dominant in summer. Limonene was dominant only in winter due to the consumption of tangerines. The nine VOCs with the highest concentrations comprised 64.8% and 49.6% of the TVOC in summer and winter, respectively. Comparing two types of adsorbent tube, a single adsorbent tube with Tenax-TA had similar detection performance as a double adsorbent tube with Tenax and Carbotrap.