• Title/Summary/Keyword: Temporal Coherence

Search Result 91, Processing Time 0.03 seconds

Impact of Sea Surface Scattering on Performance of QPSK (해면산란이 QPSK 성능에 미치는 영향)

  • Xue, Dandan;Seo, Chulwon;Park, Jihyun;Yoon, Jong Rak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1818-1826
    • /
    • 2014
  • Time-variant sea surface causes a forward scattering and Doppler spreading in received signal on underwater acoustic communication system. This results in time-varying amplitude, frequency and phase variation of the received signal. In such a way the channel coherence bandwidth and fading feature also change with time. Consequently, the system performance is degraded and high-speed coherent digital communication is disrupted. In this paper, quadrature phase shift keying (QPSK) performance is examined in two different sea surface conditions. The impact of sea surface scattering on performance is analyzed on basis of the channel impulse response and temporal coherence using linear frequency modulation (LFM) signal. The impulse response and the temporal coherence of the rough sea surface condition were more unstable and less than that of the calm sea surface condition, respectively. By relating these with time variant envelope, amplitude and phase of received signal, it was found that the bit error rate (BER) of QPSK are closely related to time variation of sea surface state.

Coherence Analysis of Jaw and Neck Muscle Coordination during Chewing in Healthy Adults

  • Ho-Jun Song;Sang-Ho Han;Ji-Yeon Kim;Yeong-Gwan Im
    • Journal of Oral Medicine and Pain
    • /
    • v.48 no.4
    • /
    • pp.159-168
    • /
    • 2023
  • Purpose: Coordinated activity between the jaw and neck muscles is important in oral motor tasks such as chewing. This study examined coherence between the jaw and neck muscles during chewing in healthy adults. Methods: A total of 12 healthy adults underwent electromyography (EMG) of the jaw and neck muscles during right-sided chewing at a frequency of 1 Hz. Surface electrodes were placed over the temporalis (TA), masseter (MS), anterior digastric (DA), and sternocleidomastoid (SM) muscles on the right side. EMG signals were processed for coherence and phase analysis using advanced signal processing techniques. Results: The MS and TA muscle pair exhibited high synchronization when chewing (median coherence=0.992). Contrarily, the coherence values between the MS and DA, as well as the MS and SM muscle pairs, were relatively low (median coherence=0.848 and 0.957, respectively). Phase analysis revealed minimal temporal differences between the MS and TA muscle pair and the MS and SM muscle pair, whereas substantial phase shifts were observed between the MS and DA muscle pair. Conclusions: During chewing in healthy adults, the TA muscle works synergistically whereas the DA muscle antagonistically with the MS muscle, and the SM muscle supports the activity of the MS muscle. The observed synchrony and coordination provide insights into the intricate interplay among these muscles during oral motor tasks.

Analysis of Characteristics of Air Pollution Over Asia with Satellite-derived $NO_2$ and HCHO using Statistical Methods (환경 위성관측자료의 통계분석을 통한 동아시아 대기오염특성 연구)

  • Baek, K.H.;Kim, Jae Hwan
    • Atmosphere
    • /
    • v.20 no.4
    • /
    • pp.495-503
    • /
    • 2010
  • Satellite data have an intrinsic problem due to a number of various physical parameters, which can have a similar effect on measured radiance. Most evaluations of satellite performance have relied on comparisons with limited spatial and temporal resolution of ground-based measurements such as soundings and in-situ measurements. In order to overcome this problem, a new way of satellite data evaluation is suggested with statistical tools such as empirical orthogonal function(EOF), and singular value decomposition(SVD). The EOF analyses with OMI and OMI HCHO over northeast Asia show that the spatial pattern show high correlation with population density. This suggests that human activity is a major source of as well as HCHO over this region. However, this analysis is contradictory to the previous finding with GOME HCHO that biogenic activity is the main driving mechanism(Fu et al., 2007). To verify the source of HCHO over this region, we performed the EOF analyses with vegetation and HCHO distribution. The results showed no coherence in the spatial and temporal pattern between two factors. Rather, the additional SVD analysis between $NO_2$ and HCHO shows consistency in spatial and temporal coherence. This outcome suggests that the anthropogenic emission is the main source of HCHO over the region. We speculate that the previous study appears to be due to low temporal and spatial resolution of GOME measurements or uncertainty in model input data.

Unequal-path Low-coherence Interferometry Using Femtosecond Pulse Lasers for Surface-profile Metrology (펨토초 레이저를 이용한 형상 측정용 비동일 광경로 저결 맞음 간섭계)

  • Oh, Jeong-Seok;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.9 s.186
    • /
    • pp.102-110
    • /
    • 2006
  • We discuss two possibilities of using femtosecond pulse lasers as a new interferometric light source for enhanced precision surface-profile metrology. First, a train of ultra-fast laser pulses yields repeated low temporal coherence, which allows unequal-path scanning interferometry, which is not feasible with white light. Second, the high spatial coherence of femtosecond pulse lasers enables large-sized optics to be tested in nonsymmetric configurations with relatively small-sized reference surfaces. These two advantages are verified experimentally using Fizeau and Twyman-Green type scanning interferometers.

Design and Fabrication of Optical Element for Speckle Reduction in Laser Projector (레이저 프로젝터의 스페클 저감을 위한 광학 소자 설계 및 제작)

  • Lee, Jae-Yong;Kim, Young-Joo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.10 no.2
    • /
    • pp.55-60
    • /
    • 2014
  • Laser projector has many advantages of high brightness, high resolution and small size, but the huge drawback of image degradation called speckle which generated by coherence of laser and roughness of surface interrupts their general use. There are many methods to reduce speckle pattern, but they need effective optical systems to realize display to the far field with huge volume. We designed speckle reduction element by using microlens with controlled curvature to reduce spatial coherence. Vibration element was also applied to reduce temporal coherence which considered response time of eye. Designed element was fabricated by simple reflow method and imprinting method. From the results, the fabricated element performed 48.33% of speckle reduction efficiency and 41.29% of optical efficiency with a single doublet lens.

Unequal-path Low-coherence Interferometry Using Femtosecond Pulse Lasers (펨토초 레이저를 이용한 비동일 광경로 저결맞음 간섭계)

  • Oh J.S.;Kim S.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.204-207
    • /
    • 2005
  • We discuss two possibilities of using femtosecond pulse lasers as a new interferometric light source fer enhanced precision surface profile metrology. First, a train of ultra-fast laser pulses yields repeated low temporal coherence, which allows performing unequal-path scanning interferometry that is not feasible with white light. Second, high spatial coherence of femtosecond pulse lasers enables to test large size optics in non-symmetric configurations with relatively small size reference surfaces. These two advantages are verified experimentally using Fizeau and Twyman-Green type scanning interferometers.

  • PDF

Stereo Video Retargeting with Representative Seams in a Group of Stereoscopic Frames

  • Nguyen, Hai Thanh;Won, Chee Sun
    • ETRI Journal
    • /
    • v.35 no.6
    • /
    • pp.980-989
    • /
    • 2013
  • The important requirements for stereo video retargeting are threefold: keeping temporal coherence, preventing depth distortion, and minimizing shape distortions of the retargeted video. To meet these requirements, the left and right video sequences are divided into groups of frames (GoFs), where the GoF is a basic unit for the seam carving and we assign a set of fixed seams for all frames within the GoF. To determine the fixed seams for each GoF, we need to find the GoF boundary in the video first. Then, the representative frame for each GoF is generated by considering the spatial saliency and temporal coherence. Also, the confidence of the stereoscopic correspondence between the left and right frames is considered to prevent depth distortion.

An Extensive Analysis of High-density Electroencephalogram during Semantic Decision of Visually Presented Words

  • Kim, Kyung-Hwan;Kim, Ja-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.170-179
    • /
    • 2006
  • The purpose of this study was to investigate the spatiotemporal cortical activation pattern and functional connectivity during visual perception of words. 61 channel recordings of electroencephalogram were obtained from 15 subjects while they were judging the meaning of Korean, English, and Chinese words with concrete meanings. We examined event-related potentials (ERP) and applied independent component analysis (ICA) to find and separate simultaneously activated neural sources. Spectral analysis was also performed to investigate the gamma-band activity (GBA, 30-50 Hz) which is known to reflect feature binding. Five significant ERP components were identified and left hemispheric dominance was observed for most sites. Meaningful differences of amplitudes and latencies among languages were observed. It seemed that familiarity with each language and orthographic characteristics affected the characteristics of ERP components. ICA helped confirm several prominent sources corresponding to some ERP components. The results of spectral and time-frequency analyses showed distinct GBAs at prefrontal, frontal, and temporal sites. The GBAs at prefrontal and temporal sites were significantly correlated with the LPC amplitude and response time. The differences in spatiotemporal patterns of GBA among languages were not prominent compared to the inter-individual differences. The gamma-band coherence revealed short-range connectivity within frontal region and long-range connectivity between frontal, posterior, and temporal sites.

An Efficient z-Buffer Algorithm using Temporal Coherence (시간 일관성을 이용한 효율적인 z-버퍼 알고리즘)

  • Oh, Kyung-Su;Shin, Yeong-Gil;Shin, Byeong-Seok
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.1
    • /
    • pp.13-22
    • /
    • 2000
  • We present a method that enhances the rendering speed of z-buffer algorithm using temporal coherence between two contiguous frames on fixed viewing conditions. Conventional z-buffer algorithm stores depth value for each pixel on a view plane while rendering some polygons, then it determines the visibility of the remaining polygons based on the stored depth values. If we can get color and depth information for some polygons without rendering, it is possible to generate an image by rendering only the remaining ones. In case of high frame rate, we can find the fact that sets of static polygons of the two contiguous frames are almost the same. This temporal coherence enables us to get the color and depth information of static polygons efficiently. Our algorithm stores color and depth information of static polygons and reuses it for generating the next frame. This method can be easily implemented since it does not require complex data structure and modification for conventional z-buffer algorithm. Also it is adequate for hardware implementation.

  • PDF

Measurement of the degree of second order temporal coherence $g_s^{(2)}({\tau})$ of a laser speckle backscattered from a rotating randomly rough metal surface (회전하는 거친금속표면에서 후방산란되어 형성된 레이저 스펙클의 세기의 시간상관함수 $g_s^{(2)}({\tau})$의 측정)

  • 안성준;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.161-166
    • /
    • 1992
  • The s-polarized laser beam is incident with an angle ~$-30^{\circ}$ to a uniformly rotating rough metal surface and the degree of second order temporal coherence $g_{s}^{(2)}(\tau)$ of the backscattered wave, which has the same polarization with the incident laser beam, is measured. The contribution of shot noise involved in the measurement of $g_{s}^{(2)}(0)$ is subtracted from the photoelectric signal to obtain the accurate value of $g_{s}^{(2)}(0)$.At each scattering angle$\theta_{s}$에서$g_{s}^{(2)}(\tau)$ is almost consistent with the function {1+exp($-\tau^2/\tau_0^2$)}, which is the same result with the case of the laser speckle formed by scattering on the rotating ground glass suface. In addition, a peak in the angular distribution of $\tau_0$ is observed with the maximum at$\theta_s=34^{\circ}$.It is found that the rough metallic scattering with multiple scattering over than 10% has the same function of the degree of second order temporal coherence with that of the ground glass surface scattering where the multiple scattering is ignorably small.

  • PDF