• Title/Summary/Keyword: Temperature visualization

Search Result 356, Processing Time 0.026 seconds

Real-time Monitoring of Temperature and Relative Humidity and Visualization of Pest Survey Data for Integrated Pest Management in Collection Storage Area (유물 공간의 종합적 유해생물 관리(Integrated Pest Management)를 위한 실시간(Real-Time) 온습도 모니터링 및 유해 생물 조사 자료의 시각화)

  • Im, Ik-Gyun;Lim, Seong-Duk;Han, Gyu-Seong
    • Journal of Conservation Science
    • /
    • v.37 no.5
    • /
    • pp.440-450
    • /
    • 2021
  • Temperature and humidity data collection using real-time sensors and data loggers was conducted for integrated pest management in the collection storage and exhibition space of the Jeongnimsaji Museum, Buyeo. The real-time temperature and humidity monitoring system collected measurement data every 30 minutes and enabled real-time confirmation of the data through a linked application. If the temperature and humidity data measured in the real-time temperature and humidity monitoring system exceeds the set range, a push notification was sent to the mobile phone of the person in charge to provide status information to establish a continuous management system. Through this, it was possible to immediately recognize and take action when the temperature range exceeded the recommended relic temperature in August. We performed data visualization on the concentration of airborne fungus in the storage area and the inflow path and density of insects. Based on the recommended criteria presented by the National Institute of Cultural Heritage, The data on the spatial and temporal concentration of airborne fungus inside the collection storage were found to be maintained at a value below the standard recommended by the National Institute of Cultural Heritage (80 CFU/m3). Also, as a result of the insect inflow survey, no insects were captured inside the storage area, and in the case of the exhibition space, insects such as Scutigera coleoptrata, Loxoblemmus arietulus, Diestrammena asynamora, Koreoniscus racovitzai were captured. Based on this, as a result of visualization according to the individual density of captured insects by area, it was confirmed that the main inflow paths of insects were the external entrance and the toilet area.

Study of Different Radial Temperature Gradient Effect on Taylor-Couette Flow Instability (온도구배가 Taylor-Couette유동의 불안정성에 주는 영향에 관한 연구)

  • Cha, Jae-Eun;Liu, Dong;Tu, Xin Cheng;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.3
    • /
    • pp.35-40
    • /
    • 2010
  • We have investigated different radial temperature gradient effect on the stability of Taylor-Couette flow. The radius ratio and aspect ratio of the model was 0.825 and 48, respectively. Two heating exchangers were used for generating different temperature gradient along the radial direction. The change of flow regime in the Taylor-Couette flow was studied by increasing the Reynolds number. The results showed that: as Gr is increased in helical vortex flow regime, the vortices with the same direction of convection flow increased in size, and the vortex moving velocity also increased. It is also shown that the presence of temperature gradient obviously increased the flow instability when the Richardson number is larger than 0.0045.

Experimental Study of the Axial Slit Wall and Radial Temperature Gradient Effect on Taylor-Couette Flow (Taylor-Couette 유동에서 축방향 홈과 반경방향 온도구배의 영향에 대한 실험적 연구)

  • Lee, Sang-Hyuk;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.6 no.2
    • /
    • pp.33-38
    • /
    • 2008
  • The effect of the radial temperature gradient and the presence of slits in the wall of outer of two cylinders involved in creating a Taylor-Couette flow was investigated by measuring the velocity field inside the gap. The slits were azimuthally located along the inner wall of the outer cylinder and the number of slits used in this study was 18. The radius ratio and aspect ratio of the models were 0.825 and 48, respectively. The heating film wrapped around the inner cylinder was used for generating the constant heat flux and we ensured the constant temperature condition at the outer space of the outer cylinder. The velocity fields were measured by using the PIV(particle image velocimetry) method. The refractive index matching method was applied to remove image distortion. The results were compared with plain wall configuration of Taylor-Couette flow. From the results, the presence of slits in the wall of outer cylinder and temperature gradient increased the flow instability.

Acoustic characteristics of Anchovy schools, and visualization of their connection with water temperature and salinity in the Southwestern Sea and the Westsouthern Sea of South Korea (서해 남부와 남해 서부의 한 정점에서 수온 및 염분과 멸치 어군의 특징의 관련성 시각화)

  • Kang, Myounghee;Choi, Seok-Gwan;Hwang, Bo-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.1
    • /
    • pp.39-49
    • /
    • 2014
  • Morphological and positional characteristics of anchovy aggregations, confirmed by trawling, were examined in two locations of the southern part of theWest Sea (T1) and the western side of South Sea (T11) of South Korea. Morphological characteristics (mean length, height and area) of the anchovy aggregations at T1 were smaller than those at T11, however the positional characteristics (distributional depth and bottom depth) of the aggregations at T1 were larger than those at T11. Diverse dataset such as the ship's cruise track, the cruse map, and interpolated three-dimensional-like water temperature were visualized in multiple dimensions. For a comprehensive understanding of the anchovy aggregations within their surrounding circumstances, the interpolated water temperature transferred to the location of anchovy aggregations at both stations were visualized based on geospatial information. Using quantitative investigation, the overall range of change in water temperature and salinity of anchovy aggregations at stations was considerably small. However, the water temperature and salinity of anchovy aggregations at T11 were somewhat higher than those at T1.

Real-time SCR-HP(Selective catalytic reduction - high pressure) valve temperature collection and failure prediction using ARIMA (ARIMA를 활용한 실시간 SCR-HP 밸브 온도 수집 및 고장 예측)

  • Lee, Suhwan;Hong, Hyeonji;Park, Jisoo;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.1
    • /
    • pp.62-67
    • /
    • 2021
  • Selective catalytic reduction(SCR) is an exhaust gas reduction device to remove nitro oxides (NOx). SCR operation of ship can be controlled through valves for minimizing economic loss from SCR. Valve in SCR-high pressure (HP) system is directly connected to engine exhaust and operates in high temperature and high pressure. Long-term thermal deformation induced by engine heat weakens the sealing of the valve, which can lead to unexpected failures during ship sailing. In order to prevent the unexpected failures due to long-term valve thermal deformation, a failure prediction system using autoregressive integrated moving average (ARIMA) was proposed. Based on the heating experiment, virtual data mimicking temperature range around the SCR-HP valve were produced. By detecting abnormal temperature rise and fall based on the short-term ARIMA prediction, an algorithm determines whether present temperature data is required for failure prediction. The signal processed by the data collection algorithm was interpolated for the failure prediction. By comparing mean average error (MAE) and root mean square error (RMSE), ARIMA model and suitable prediction instant were determined.

Study on cooling performance and isothermal maintenance of cylindrical type lithium-ion battery cell using phase change material (상변화물질을 활용한 원통형 리튬이온 배터리 셀의 냉각성능 및 등온유지성에 관한 연구)

  • Jae Hyung Yoon;Su Woong Hyun;Hee Jun Jeong;Dong Ho Shin
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.34-45
    • /
    • 2023
  • When lithium-ion batteries operate out of the proper temperature range, their performance can be significantly degraded and safety issues such as thermal runaway can occur. Therefore, battery thermal management systems are widely researched to maintain the temperature of Li-ion battery cells within the proper temperature range during the charging and discharging process. This study investigates the cooling performance and isothermal maintenance of cooling materials by measuring the surface temperature of a battery cell with or without cooling materials, such as silicone oil, thermal adhesive, and phase change materials during discharge process of battery by the experimental and numerical analysis. As a result of the experiment, the battery pack filled with phase change material showed a temperature reduction of 47.4 ℃ compared to the case of natural convection. It proves the advanced utility of the cooling unit using phase change material that is suitable for use in battery thermal management systems.

A Fundamental Study on the Investigation of Bubbling Phenomenon in the Injector for the Development the LPDi Engine (액상 LPG 직접 분사식 기관 개발을 위한 인젝터 내 기포발생현상의 원인 규명에 관한 기초연구)

  • Noh, Ki-Chol;Lee, Jong-Tai
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.1-8
    • /
    • 2006
  • One of the most important subjects to develop a LPDi engine is to suppress the bubble generated inside the liquid LPG direct injector. For the purpose of this, the analogy visualization injector to visualize the generation and behaviors of bubble is manufactured, and the bubbling phenomenon and behaviors of bubble are visualized and investigated according to the change of the temperature around an injector wall, fuel pressure and a needle configuration. As results, it was found that the bubble inside the injector is generated around an injector hole and after rising by buoyancy it disappears around the top of a nozzle. The number of bubbles generated is little changed regardless of the lapse of time but it remarkably increases as the temperature around the injector increases. Also, it was known that as the sac volume in LPDi injector decreases the generation of bubble is more active and the rising velocity of bubble generated is increased.

A Study on Quantitative Visualization and Measurement of Physical Properties of Radial Symmetric Fluids Using Electronic Speckle Pattern Interferometry (전자 스체클 패턴 간섭법을 이용한 반경방향 대칭 유체의 정량적 가시화 및 물성치 측정에 관한 연구)

  • Gang, Yeong-Jun;Chae, Hui-Chang;Kim, Gyeong-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.2
    • /
    • pp.217-224
    • /
    • 2002
  • It is very important to measure and visualize the changes in the physical properties of fluid flow because this is the foundation of measurement techniques used in aerodynamics, heat transfer, plasma diagnostics, and stress analysis of transparent models. The optical methods are advantageous over probe-based techniques in the optical methods are of high speed, non-contact and are capable of providing full-field results with high spatial resolution. Therefore we propose the electronic speckle pattern interferometry(ESPI) that gives us a solution to overcome those limitations. In this paper the experimental results show qualitative and quantitative visualization of changes in the physical properties of the candle and alcohol lamp with 3D plotting. And we obtained the refractive index, mass density and temperature distribution of fluids. The results clearly show the process of flow phenomena and give the feasibility of quantitative interpretation of gasdynamics.

Ethanol Droplet Impact Behavior Visualization on the Flat and 50㎛ grating groove Al Surface (알루미늄 평판 및 50 ㎛ 간격 격자 표면에 대한 에탄올 액적 충돌 거동 가시화)

  • Kang, Dongkuk;Kwon, Daehee;Chun, Doo-Man;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.1
    • /
    • pp.18-25
    • /
    • 2020
  • The droplet impact behavior is dominated by some parameters such as surface temperature, We number, surface and fluid property. Especially, Leidenfrost effect which prevents the contact between surface and droplet is very powerful phenomenon for determining droplet impact behavior. Due to this effect, the impact regime is divided into contact boiling regime and film boiling regime whether the droplet contact with the surface. Many studies have found that surface micro-structures which processed by surface processing are effective to overcome the Leidenfrost effect. In this study, droplet impact behaviors were compared using ethanol both on flat and laser-ablated Al surface. On the flat surface, impact regime was mainly divided by surface temperature. And there is key dominant parameter for each regime. On the laser-ablated surface, we could see changed impact regime and different impact behavior such as jetting and ejection of tiny droplets despite of same impact conditions.

Temperature Data Visualization for Condition Monitoring based on Wireless Sensor Network (무선 센서 네트워크 기반의 상태 모니터링을 위한 온도 데이터 시각화)

  • Seo, Jung-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.2
    • /
    • pp.245-252
    • /
    • 2020
  • Unexpected equipment defects can cause a huge economic losses in the society at large. Although condition monitoring can provide solutions, the signal processing algorithms must be developed to predict mechanical failures using data acquired from various sensors attached to the equipment. The signal processing algorithms used in a condition monitoring requires high computing efficiency and resolution. To improve condition monitoring on a wireless sensor network(WSN), data visualization can maximize the expressions of the data characteristics. Thus, this paper proposes the extraction of visual feature from temperature data over time using condition monitoring based on a WSN to identify environmental conditions of equipment in a large-scale infrastructure. Our results show that time-frequency analysis can visually track temperature changes over time and extract the characteristics of temperature data changes.