• Title/Summary/Keyword: Temperature test equipment

Search Result 330, Processing Time 0.028 seconds

Influence of Compositions of Sintered Ti-Ni Alloys on their Thermo-mechanical Properties

  • Kyogoku, Hideki;Ikeda, Tetsuya;Komatsu, Shinichiro
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.81-82
    • /
    • 2006
  • This paper presents the influence of the compositions of sintered Ti-Ni alloys on their thermo-mechanical properties. The Ti-Ni alloys having various compositions from 50at%Ni to 51at%Ni were sintered using elemental Ti and Ni powders by a pulse-current pressure sintering equipment. The deformation resistance in stress-strain curves increased with an increase in Ni content. In the case of Ti-50at%Ni, tensile strength and elongation were more than 500 MPa and 7%, respectively. The increase in Ni content also makes the transformation temperatures lower. The deformation resistance at a test temperature change from 293K and 353K in isothermal tensile test increased with elevating test temperature.

  • PDF

Reliability assessment test for heavy sluice gate of hydraulic cylinder (수문용 대형 유압실린더의 신뢰성 평가)

  • 이용범;현동수;김형의;이근호;정동수
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.91-97
    • /
    • 2001
  • These Study are for the development of the reliability assessment test code and test equipment and test procedures of the heavy sluice gate hydraulic cylinder. Because there is no reliability test code for the heavy sluice gate hydraulic cylinder inside and outside of the country, the modified reliability test code is made reference for the related existing standards like as ISO, JIS, MIL, TUV, DIN, KS and etc. In this study, the novel method is proposed to evaluate efficiency of the heavy sluice gate hydraulic cylinder on the loading conditions and established the conditions of the acceleration life test to reduce the testing time and cycles. The testing equipments for life test, lode operating test, high and low temperature test and salt spray test have been established for 8 month, and the reliability tests are accomplished. The test results of the heavy sluice gate hydraulic cylinder which is produced and tested initially in Korea are satisfied the durability life cycle on the using conditions.

  • PDF

Corrosion Analysis of Ni alloy according to the type of molten metal (용융아연도금욕에 적용되는 용탕에 따른 Ni합금의 부식성 분석)

  • Baek, Min-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.459-463
    • /
    • 2017
  • Hot dip galvanizing in the steel plant is one of the most widely used methods for preventing the corrosion of steel materials including structures, steel sheets, and materials for industrial facilities. While hot dip galvanizing has the advantage of stability and economic feasibility, it has difficulty in repairing equipment and maintaining the facilities due to high-temperature oxidation caused by Zn Fume where molten zinc used in the open spaces. Currently, SM45C (carbon steel plate for mechanical structure, KS standard) is used for the equipment. If a part of the equipment is resistant to high temperature and Zn fume, it is expected to improve equipment life and performance. In this study, the manufactured Ni alloy was tested for its corrosion resistance against Zn fume when it was used in the hot dip galvanizing equipment in the steel plant. Two kinds of materials currently used in the equipment, new Ni alloy and Inconel(typical corrosion-resistant Ni alloy), were selected as the reference groups. Two kinds of molten metal were used to confirm the corrosion of each alloy according to the molten metal. Zn fume was generated by bubbling Ar gas from molten Zn in a furnace($500{\sim}700^{\circ}C$) and the samples were analyzed after 30 days. After 30 days, the specimens were taken out, the oxide layer on the surface was confirmed with an optical microscope and SEM, and the corrosion was confirmed using a potentiodynamic polarization test. Corrosion depends on the type of molten metal.

Infrared Temperature Monitoring System based CAN for USN (USN를 위한 CAN 기반 적외선 온도감시 시스템)

  • Kim, Young-Dong;Oh, Guem-Kon;Jeong, Won-Tae;Kang, Won-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.11-17
    • /
    • 2007
  • RWe have developed an infrared temperature monitoring system to measure the temperature of hot iron plate in very harsh environmental conditions as iron making equipment. We performed extensive field test for 3 months at the front side of iron plate rolling process of POSCO in Gwang-Yang. From the experimental test, we have confirmed the reliability of the developed system. We adjust the curve fit method to solve the non-linearity equations of A2TPMI sensor, and establish the under $1[^{\circ}C]$precision ratio and 25[msec] process speed each range. As experimental, we have confirmed the reliability of an infrared temperature monitoring system as POSCO test result and CAN network traffic monitoring of polling method.

A Study on Mechanical Properties Changes to Improve the Confidence of Remaining Life Evaluation for the Weldment of Power Plant Boiler Tube(SA213-T12) (발전설비 보일러 튜브 용접부의 잔여수명평가 신뢰성 향상을 위한 기계적 물성 변화 연구(SA213-T12))

  • Oh, Byungjin;Jang, Joong Soon
    • Journal of Welding and Joining
    • /
    • v.32 no.3
    • /
    • pp.102-107
    • /
    • 2014
  • Boiler equipment in power plant is always being operated in harsh conditions and severely exposed to the extreme environment of high temperature. Therefore periodically the state of devices should be checked, diagnosed, and analyzed to ensure the reliability of the equipment. Traditionally, such a diagnosis is based one or two physical properties of the sample taken from the equipment like hardness, microstructure, etc.. However, to enhance the confidence of the diagnosis, it is necessary to synthesize those properties together. This paper is to propose such a synthetic procedure for SA213-T12(1Cr-0.5Mo) which was developed to be used in $565^{\circ}C$ below condition. Creep test and accelerated degradation test were performed simultaneously, and the physical properties such as microstructure, tensile strength, yield strength, hardness, and indentation properties were measured. This paper proposes a method of determining the remaining life by quantitative comparison. It will provide the basis of evaluating life assessment more objective and reliable.

A Study on Mechanical Properties Changes to Improve the Confidence of Remaining Life Evaluation for the Weldment of Power Plant Boiler Tube (발전설비 보일러 튜브 용접부의 잔여수명평가 신뢰성 향상을 위한 기계적 물성 변화 연구)

  • Oh, Byungjin;Jang, Joong Soon
    • Journal of Welding and Joining
    • /
    • v.31 no.5
    • /
    • pp.26-34
    • /
    • 2013
  • Boiler equipment in power plant is always being operated in harsh conditions and severely exposed to the extreme environment of high temperature. Therefore periodically the state of devices should be checked, diagnosed, and analyzed to ensure the reliability of the equipment. Traditionally, such a diagnosis is based one or two physical properties of the sample taken from the equipment like hardness, microstructure, etc.. However, to enhance the confidence of the diagnosis, it is necessary to synthesize those properties together. This paper is to propose such a synthetic procedure for T23 which was developed to be used in $569^{\circ}C/596^{\circ}C$ condition. Creep test and accelerated degradation test were performed simultaneously, and the physical properties such as microstructure, tensile strength, yield strength, hardness, and indentation properties were measured. This paper proposes a method of determining the remaining life by quantitative comparison. It will provide the basis of evaluating life assessment more objective and reliable.

Tensile Characteristics of A12024-T3 under Rapid Heating (급속가열환경에서 A12024-T3의 인장특성)

  • Kim, Jong-Hwan;Kim, Jae-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.8
    • /
    • pp.101-108
    • /
    • 2004
  • The thermomechanical tensile characteristics were evaluated for A12024-T3 under heating rates from $1^{\circ}C/sec\;to\;30^{\circ}C/sec$ by using an infrared heating equipment to simulate aerodynamic heating. The rapid heating test results were compared with tensile test results after 1/2 hour exposure in terms of yield stress to investigate the influence of heating condition. A heating rate-yield temperature parameter was suggested for rapid heating based on time-temperature parameters, and master yield stress curve was obtained by using these parameter. These test results can be used for margin of safety of supersonic vehicle structures subjected to aerodynamic heating.

An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber (PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구)

  • Joo, Hongjin;Kwak, Heeyoul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

Finite Element Analysis of Warm Peening Process on Spring Steel for Surface Durability Improvement (스프링강 표면 내구수명 향상을 위한 온간 피닝 공정의 유한요소 해석)

  • Lee, Sangwook;Kim, Jaeyeon;Park, Jaiwon;Byeon, Jaiwon
    • Journal of Applied Reliability
    • /
    • v.18 no.1
    • /
    • pp.72-79
    • /
    • 2018
  • Purpose: Numerical and experimental study was performed to evaluate the effect of peening temperature on the residual compressive stress distribution and magnitude of residual compressive stress at the material surface. Methods: A compressive air-propelled warm peening equipment was designed and manufactured for warm peening test. Results: 3D dynamic finite element (FE) model of the warm peening test was proposed and validity of the proposed FE model was verified by comparing the predicted residual stresses with the measured residual stresses in the open literature. Maximum warm peening temperature and a proper peening time were investigated with the proposed FE model. Conclusion: Compressive residual stress increased remarkably with peening temperature increased. But, peening temperature is greater than $350^{\circ}C$, the effect of peening temperature disappeared. Therefore, maximum peening temperature possibly applicable for warm peening industry might be $350^{\circ}C$ and peening time is 45s.

Development of a System for Measuring the Velocity of a Waste-gas Produced from a Melting Process (용해공정에서 배출되는 폐가스 유속 측정 시스템 개발)

  • Park, Jin Soo;Jung, Jae Hak;Sung, Su Whan
    • Korean Chemical Engineering Research
    • /
    • v.46 no.2
    • /
    • pp.340-347
    • /
    • 2008
  • In the case of a melting process, the velocity of waste-gas has been measured to produce the melt of an equal condition and to analyze the combustion situation of the fuel which was inputted in a furnace. Recently, there are many kinds of measuring equipments of gas-velocity on the market. But, the waste-gas produced from a melting process is high temperature, the slow speed and includes much dust. Existent measuring equipments are not suited to these conditions. Therefore, we made the measuring equipment of new method which is enough detailed to react on the slow speed and sustains in high temperature. As shown in the result of field test, the manufactured measuring equipment is so sensitive as to react on a small change of velocity and senses temperature change rapidly, we expect that this equipment helps in temperature control of a melting furnace.