• 제목/요약/키워드: Temperature reversal

검색결과 64건 처리시간 0.022초

Effect of Interface Roughness on Exchange Bias of an Uncompensated Interface: Monte Carlo Simulation

  • Li, Ying;Moon, Jung-Hwan;Lee, Kyung-Jin
    • Journal of Magnetics
    • /
    • 제16권4호
    • /
    • pp.323-327
    • /
    • 2011
  • By means of Monte Carlo simulation, we investigate the effects of interface roughness and temperature on the exchange bias and coercivity in ferromagnetic (FM)/antiferromagnetic (AFM) bilayers. Both exchange bias and coercivity are strongly dependent on interface roughness. For a perfect uncompensated interface a domain wall is formed in the AFM system during FM reversal, which results in a very small exchange bias. However, a finite interface roughness leads to a finite value of the exchange bias due to the existence of pinned spins at the AFM surface adjacent to the mixed interface. It is observed that the exchange bias decreases with increasing temperature, consistent with the experimental results. It is also observed that a bump in coercivity occurs around the blocking temperature.

열화된 광유와 식물성절연유에서 온도, 벤조트리아졸의 유동대전 영향 (Influence of Temperature and Benzotriazole on the Flow Electrification by aging Mineral, Vegetable Oil)

  • 최순호;정중일;허창수
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.338-343
    • /
    • 2011
  • In this paper, the FT-IR, conductivity and flow electrification phenomena of Vegetable oils were discussed. Vegetable oil has high flash point and eco-friendly properties compared to conventional mineral oil. Accelerated aging transformer oil samples produced in the oven at 140[$^{\circ}C$] for 500 hours, 1000 hours, 1500 hours, 2000 hours. Serial device to measure the flow electrification phenomena was designed and fabricated. Pico ammeter and the Labview data measurements were utilized. The effects of Temperature and antistatic agent on fluid flow electrification were investigated. Both Mineral and vegetable oil showed similar trends for temperature change. The polarity reversal occurred in mineral oil with antistatic agent above 10 ~ 30[ppm] and in vegetable oil with antistatic agent above 5[ppm].

IGCC 합성가스 냉각기 GRC의 열유동 및 입자거동 특성에 대한 전산해석 연구 (Numerical Simulations on the Thermal Flow and Particle Behaviors in the Gas Reversal Chamber of a Syngas Cooler for IGCC)

  • 박상빈;예인수;류창국;김봉근
    • 한국연소학회지
    • /
    • 제18권1호
    • /
    • pp.21-26
    • /
    • 2013
  • In the Shell coal gasification process, the syngas produced in a gasifier passes through a syngas cooler for steam production and temperature control for gas cleaning. Fly slag present in the syngas may cause major operational problems such as erosion, slagging, and corrosion, especially in the upper part of the syngas cooler (gas reversal chamber, GRC). This study investigates the flow, heat transfer and particle behaviors in the GRC for a 300 MWe IGCC process using computational fluid dynamics. Three operational loads of 100%, 75% and 50% were considered. The gas and particle flows directly impinged on the wall opposite to the syngas inlet, which may lead to erosion of the membrane wall. The heat transfer to the wall was mainly by convection which was larger on the side wall at the inlet level due to the expansion of the cross-section. In the evaporator below the GRC, the particles were concentrated more on the outer channels, which needs to be considered for alleviation of fouling and blockage.

고온초전도 직류 케이블용 절연재료인 PPLP의 직류 및 임펄스 절연 특성 (DC and Impulse Insulation Characteristics of PPLP for HTS DC Cable)

  • 김우진;방만식;김해종;조전욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제26권7호
    • /
    • pp.545-549
    • /
    • 2013
  • To realize the high-Tc superconducting (HTS) DC cable system, it is important to study not only high current capacity and low loss of conductor but also optimum electrical insulation at cryogenic temperature. A model HTS DC cable system consists of a HTS conductor, semi-conductor, cooling system and insulating materials. Polypropylene laminated paper (PPLP) has been widely adopted as insulating material for HTS machines. However, the fundamental insulation characteristics of PPLP for the development of HTS DC cable have not been revealed satisfactorily until now. In this paper, we will discuss mainly on the breakdown characteristics of 3 sheets PPLP in liquid nitrogen ($LN_2$). The characteristics of the diameter, location of butt-gap, distance between butt-gap length, pressure effect, polarity effect under DC and impulse voltage were studied. Also, the DC polarity reversal breakdown voltage of mini-model cable was measured in $LN_2$ under 0.4 MPa.

Sol-gel법을 이용한 PLZT박막 커패시터의 전기적 특성 (Electrical properties of the PLZT thin film capacitors by the sol-gel method)

  • 박준열;정장호;이성갑;이영희
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권7호
    • /
    • pp.668-673
    • /
    • 1996
  • In this paper, (P $b_{1-x}$ L $a_{x}$)(Z $r_{0.52}$ $Ti_{0.48}$) $O_{3}$ (X=0-13[at%]) thin film were prepared by the Sol-Gel method, Multiple PLZT thin films were spin-coated on the Pt/Ti/ $SiO_{2}$Si substrate. The electrical properties of the films were investigated for varying the annealing temperature. In the PLZT(11/52/48) specimens, the dielectric ocnstant of 1236 and the polarization reversal time of 460[nm] were obtained and the breakdown of the film did not occur up to 1*10$^{10}$ cycles at the voltage of 7[V] by the bipolar acceleration. The remanent polarization and coercive field decreased with increasing the content of La in the range of 0-13[at%] and thin film of the PLZT(11/52/48) showed the value of 2.56[.mu.C/c $m^{2}$] and 21.1[kV/cm], respectively.ly.y.

  • PDF

Why Are Peak Loads Observed during Winter Months in Korea?

  • KIM, JEE YOUNG;OH, HYUNGNA;CHOI, KYUNG-MEE
    • KDI Journal of Economic Policy
    • /
    • 제41권1호
    • /
    • pp.43-58
    • /
    • 2019
  • Since 2009, electricity consumption has developed a unique seasonal pattern in South Korea. Winter loads have sharply increased, and they eventually exceeded summer peaks. This trend reversal distinguishes these load patterns from those in the USA and the EU, where annual peaks are observed during the summer months. Using Levene's test, we show statistical evidence of a rise in temperature but a decrease in variance over time regardless of the season. Despite the overall increase in the temperature, regardless of the season there should be another cause of the increased demand for electricity in winter. With the present study using data from 1991 to 2012, we provide empirical evidence that relatively low electricity prices regulated by the government have contributed significantly to the rapid upward change in electricity consumption, specifically during the winter months in the commercial sector in Korea.

Loss of coolant accident analysis under restriction of reverse flow

  • Radaideh, Majdi I.;Kozlowski, Tomasz;Farawila, Yousef M.
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1532-1539
    • /
    • 2019
  • This paper analyzes a new method for reducing boiling water reactor fuel temperature during a Loss of Coolant Accident (LOCA). The method uses a device called Reverse Flow Restriction Device (RFRD) at the inlet of fuel bundles in the core to prevent coolant loss from the bundle inlet due to the reverse flow after a large break in the recirculation loop. The device allows for flow in the forward direction which occurs during normal operation, while after the break, the RFRD device changes its status to prevent reverse flow. In this paper, a detailed simulation of LOCA has been carried out using the U.S. NRC's TRACE code to investigate the effect of RFRD on the flow rate as well as peak clad temperature of BWR fuel bundles during three different LOCA scenarios: small break LOCA (25% LOCA), large break LOCA (100% LOCA), and double-ended guillotine break (200% LOCA). The results demonstrated that the device could substantially block flow reversal in fuel bundles during LOCA, allowing for coolant to remain in the core during the coolant blowdown phase. The device can retain additional cooling water after activating the emergency systems, which maintains the peak clad temperature at lower levels. Moreover, the RFRD achieved the reflood phase (when the saturation temperature of the clad is restored) earlier than without the RFRD.

Circadian Rhythms of Melatonin, Thyroid-Stimulating Hormone and Body Temperature: Relationships among those Rhythms and Effect of Sleep-Wake Cycle

  • Kim, Mi-Seung;Lee, Hyun J.;Im, Wook-Bin
    • Animal cells and systems
    • /
    • 제6권3호
    • /
    • pp.239-245
    • /
    • 2002
  • Plasma melatonin, thyroid-stimulating hormone (TSH) and body temperature were measured simultaneously and continuously before and after the sleep-wake cycle was shifted in 4 healthy males and changes in the circadian rhythm itself and in the phase relationship among these circadian rhythms were determined. Normal sleep-wake cycle (sleep hours: 2300-0700) was delayed by 10 h (sleep hours: 0900-1700) during the experiment. Even after this shift the typical melatonin rhythm was maintained: low during daytime and high during night. The melatonin rhythm was gradually delayed day by day. The TSH rhythm was also maintained fundamentally during 3 consecutive days of altered sleep-wake cycle. The phase was also delayed gradually but remarkably. The daily rhythm of body temperature was changed by the alteration of sleep-wake cycle. The body temperature began to decrease at the similar clock time as in the control but the decline during night awake period was less steep and the lowered body temperature persisted during sleep. The hormonal profiles during the days of shifted sleep/wake cycle suggest that plasma melatonin and TSH rhythms are basically regulated by an endogenous biological clock. The parallel phase shift of melatonin and TSH upon the change in sleep-wake cycle suggests that a common unitary pacemaker probably regulates these two rhythms. The reversal phase relationship between body temperature and melatonin suggests that melatonin may have a hypothermic effect on body temperature. The altered body temperature rhythm suggests that the awake status during night may inhibit the circadian decrease in body temperature and that sleep sustains the lowered body temperature. It is probable but uncertain that there ave causal relationships among sleep, melatonin, TSH, and body temperature.

몬테-칼로 모의실험을 이용한 대기권 재진입 시스템의 불확실성 성능 평가 (Evaluation of Performance of Atmospheric Re-Entry System for the Uncertainties Using the Monte-Carlo Simulation)

  • 이대우;조겸래;오세종
    • 한국항공우주학회지
    • /
    • 제30권7호
    • /
    • pp.51-60
    • /
    • 2002
  • 통계학적 해석인 몬테-칼로 모의실험은 대기권 재진입 분산의 결과인 낙하예정지역뿐만 아니라 상태변수들의 최종조건들을 조사하는데도 사용된다. 본 논문에서 재진입 분산은 위도, 경도, 고도, 뱅크각, 비행경로각, 기수 오차, 그리고 항속거리로 생성되는 $7\times7$ 공분산 행렬로 한정된다. 감속을 목표로 하는 대기권 재진입시 이것들에 영향을 미치는 오차 원인들은 대기밀도, 온도, 초기오차, 바람, 그리고 항력계수의 추정오차 등에 관련된 불확실성들로서 이들 오차의 $3{\sigma}_n$와 공칭 비행궤적을 사용해서 상태변수의 공분산 행렬은 궤적 오차 해석을 수행함으로 결정될 수 있다. 재진입에 대한 몬테-칼로법의 적용에 있어서 주요 고려할 점은 교란궤적, 뱅크역전, 그리고 이 제적들 각각에 대한 최종 낙하지점의 결정이다. 본 논문은 불확실성에 대한 결과를 공력계수와 뱅크역전의 관점에서 해석한다.