• 제목/요약/키워드: Temperature on the ceiling

Search Result 135, Processing Time 0.036 seconds

The Resistance Characteristics and Reliability Evaluation of an Insulation Ring Type of Corrugated Stainless Steel Tubing(CSST) (절연링형 금속플렉시블호스(CSST)의 저항 특성 및 신뢰성 평가)

  • Lee, Jang-Woo;Kim, Jeom-Sik;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.25-31
    • /
    • 2016
  • This paper has analyzed the structure, applicable regulations and the resistance characteristics of insulation ring type of CSST (Corrugated Stainless Steel Tubing for Gas). With the flammability test conducted in accordance with KS C IEC 60811-1-1, the evaluation of insulation resistance, temperature characteristics, and reliability has been conducted. An insulation ring type CSST consists of protective coating, tube, nut, insulation ring, packing, socket, and ball valve. Connecting an insulation ring type CSST to gas tubings for gas appliance is not permitted, moreover, the product shall be installed inside a sleeve pipe in case of buried installation such as the ceiling. Damages on protective coating and tube were detected when fire was applied to the test sample with a portable torch for 60 seconds. The insulation resistance of a normal product was $49.59M{\Omega}$, while that of the product completed the flammability test reduced to $9.21M{\Omega}$. The mean insulation resistance within the confidence Interval of 95% using the mini tap program 17 was $49.59M{\Omega}$ and the mean insulation resistance within the confidence interval reduced to $9.21M{\Omega}$. In the normal distribution analysis of 95% confidence interval, the value-P of the normal product was stable at 0.075 and AD(Anderson-Darling) statistic value was turned out to be 0.063, which is very normal, and the standard deviation was analyzed as 0.2586. The value P of the product completed the flammability test resulted in 0.005, the AD was 1.355 and the standard deviation reduced to 0.07908.

Improvement of Fire Detection in Rack-type Warehouses using FDS (FDS를 이용한 랙크식 창고의 화재감지 개선에 관한 연구)

  • Choi, Ki-Ok;Park, Moon-Woo;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.55-60
    • /
    • 2019
  • The occurrence of fire in rack-type warehouses may either lead to the warehouses getting entirely burned up or collapsing. This can be attrubuted to the high height of rack-type warehouses, in which combustibles are generally vertically stacked. These characteristics make it difficult to detect a fire early; because detectors are installed on the ceiling, these fires cannot be extinguished at an early stage. In this study, the flow of heat and smoke generated by a fire in a rack-type warehouse was analyzed using a fire dynamic simulator. Through this analysis, the optimal installation conditions of fire detectors for the early detection of fire in rack-type warehouses were confirmed. The analysis results confirmed that complex detection of heat and smoke is required for the early detection of fire in rack type warehouses. Furthermore, it was found that fixed temperature detectors are not suitable for these warehouses, resulting in the need to install heat-smoke hybrid detectors at every three rack levels.

Experimental Study on the Thermal Properties of Materials for Fire Resistive Ceiling Structure at High Temperature (내화천장구조 재료의 고온 열특성 실험 연구)

  • Yeo, In-Hwan;Cho, Bum-Yean;Min, Byung-Yeol;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.334-339
    • /
    • 2011
  • 이 연구에서는 내화천장구조 재료의 고온 열특성을 파악하여, 건축물 화재시 천장구조에 대한 보다 정확한 화재성상예측을 위한 실험적 자료로 제시하고자 한다. 건축물의 화재성상 예측은 내화설계 시 반드시 필요하며, 화재성상예측을 위해서는 화재하중, 작용외력, 안전계수 및 설계용 정수의 합리적인 설정이 중요하다. 화재하중 및 작용외력 등은 건축물의 부재가 지니는 하중조건에 대한 화재시의 부재 안정성 예측에 관계되는 부분이며, 설계 시 필요한 데이터 중 내화천장구조 재료의 고온 열특성 값은 화재발생 구획의 화재온도가 주요 구조부재에 전달되는 정도를 예측할 수 있는 인자로 볼 수 있다. 따라서 내화천장구조 재료의 고온 열특성 값 설정은 화재발생 공간의 온도범위($20{\sim}1000^{\circ}C$)에 걸쳐 평가 및 분석되어야만 정확하고 신뢰성 있는 화재발생 예상 공간의 부재 온도 및 안전성 분석이 가능하다. 이에 국내 건축구조물에 사용되고 있는 대표적인 내화피복 재료인 방화석고보드, 텍스, 암면에 대해서 $20^{\circ}C{\sim}900^{\circ}C$까지의 열전도율을 측정하였다. 실험결과 방화석고보드와 텍스의 경우 약 0.15 W/m K까지 일정하게 증가하였다. 암면의 경우 약 $700^{\circ}C$까지는 방화석고보드나 텍스에 비해 열전도율이 낮게 나타났지만, $800^{\circ}C$ 지점부터 용융 및 탄화가 진행되면서 열전도율이 급격히 상승하는 것으로 나타났다.

  • PDF

TECHNICAL STUDY ON THE CONTROLLING MECHANIQUES OF THE ENVIRONMENTAL FACTORS IN THE MUSHROOM GROWING HOUSE IN CHONNAM PROVINCE (전남지방(全南地方)에 있어서의 양송이 재배(栽培)에 최적(最適)한 환경조건(環境條件) 조절법분석(調節法分析)에 관(關)한 연구(硏究))

  • Lee, Eun Chol
    • Journal of Korean Society of Forest Science
    • /
    • v.9 no.1
    • /
    • pp.1-44
    • /
    • 1969
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demostrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental houses showed a sufficient heat insulation on effect to protect insides of the houses from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar houses to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on-ground type house, and (2) the solar heat generating system should be reconstructed properly. A trial solar heat generating system is shown in Fig. 40. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom houses. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that x is the outside temperature and y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between x and y can be expressed by the following regression lines. Underground iron pipe ventilation system ${\cdots}{\cdots}$ y=0.9x-12.8 Underground earthen pipe ventilation system ${\cdots}{\cdots}$y=0.96x-15.11 Vertical side wall ventilation system${\cdots}{\cdots}$ y=0.94x-17.57 5. The experimental results have shown that the relationships existing between the admitted and expelled air and the $Co_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 1) If it is assumed that x is an air speed cm/sec. and y is an expelled air speed in cm/sec. in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below: 2) If it is assumed that x is an admitted volume of air in $m^3/hr$ and y is an expelled volume of air in $m^3/hr$ in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below. 3) If it is assumed that the expelled air speed in cm/sec and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as x and y, respectively, since the y is a function of the x, the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}$ y=0.54X+0.84 4) If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as x, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as y, in a natural ventilation system, since the y is a function of the x the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}{\cdots}$ y=114.53-6.42x 5) If it is assumed that the expelled volume of air is shown as x and the $CO_2$ concentration which is expressed by multiplying 1000 times the actual of $CO_2$ % is shown as y in a natural ventilation system, since the y is a function of of the x, the relationships that exist between x and y can be expressed by the following exponent equation: G.E. (100%)-C.V. (50%) ventilation system${\cdots}{\cdots}$ $$y=127.18{\times}1.0093^{-X}$$ 6. The experimental results have shown that the ratios of the crass sectional area of the G.E. and C.V. vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: G.E. (admitting vent of the underground ventilation)${\cdots}{\cdots}$ 0.30-0.5% (controllable) C.V. (expelling vent of the ceiling ventilation)${\cdots}{\cdots}$ 0.8-1.0% (controllable) 7. Among several heating devices which were studied in the experiments, the hot-water boilor which was modified to be fitted both as hot-water toiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Environmental Survey to a Ventilation System on the Enclosed Farrowing-nursery Pig House in Winter (무창 분만ㆍ자돈사내에서 환기시스템별 혹한기 환경 조사)

  • 유용희;송준익;정종원;김태일;최희철;양창범;이영윤
    • Journal of Animal Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 2004
  • This study was conducted to improve a ventilation system on the enclosed farrowing-nursery pig house in Korean swine facilities. This survey ventilation system types four major structures. The first structure has planer slot inlet, where air comes in, and these are placed outside the wall under the eave. Then the air from the pig house flows out through the chimney outlet operated by an exhaust fan(V1). The second structure has an air input through the perforated ceiling inlet, then the air from the pig house flows out through the chimney outlet operated by an exhaust fan(V2). Through the circular duct inlet placed inside the juncture of the entry wall, air also comes in(third structure). Then, air from the pig house flows out through the chimney outlet operated by an exhaust fan(V3), Similarly, air comes in through the circular duct inlet placed inside the juncture of the entry wall, but air from the pig house flows out through the side wall by an exhaust fan(V4). Temperature, relative humidity, air velocity and ammonia concentration(NH$_3$) were measured in the interior farrowing-nursery pig house during winter. The results were as follows; Interior temperature at the pig house was not remarkably different in all ventilation systems. The V4 system had low area air velocity, and this was better than other systems. It also had a lower ammonia concentration than other systems. V3 and V4 systems had stable airflow patterns, better than other systems. Therefore, it is suggested that the V3 and V4 ventilation system be applied in the enclosed farrowing-nursery pig house in winter.

  • PDF

The study on enhanced micro climate of the oyster mushroom cultivation house with multi-layered shelves by using CFD analysis (CFD 분석에 의한 느타리버섯 재배사 환경균일성 향상 연구)

  • Lee, Sung-Hyoun;Yu, Byeong-Kee;Lee, Chan-Jung;Lim, Yeong-Taek
    • Journal of Mushroom
    • /
    • v.15 no.1
    • /
    • pp.14-20
    • /
    • 2017
  • The oyster mushroom cultivation house typically has multiple layers of growing shelves that cause the disturbance of air circulation inside the mushroom house. Due to this instability in the internal environment, growth distinction occurs according to the area of the growing shelves. It is known that minimal air circulation around the mushroom cap facilitates the metabolism of mushrooms and improves their quality. For the purpose of this study, a CFD analysis FLUENT R16 has been carried out to improve the internal environment uniformity of the oyster mushroom cultivation house. It is found that installing a section of the working passage towards the ceiling is to maintain the internal environment uniformity of the oyster mushroom cultivation house. When all the environment control equipment - including a unit cooler, an inlet fan, an outlet fan, an air circulation fan, and a humidifier - were operated simultaneously, the reported Root Mean Square (RMS) valuation the growing shelves were as follows: velocity 23.86%, temperature 6.08%, and humidity 2.72%. However, when only a unit cooler and an air circulation fan operated, improved RMS values on the growing shelves were reported as follows: velocity 23.54%, temperature 0.51%, and humidity 0.41%. Therefore, in order to maintain the internal environment uniformity of the mushroom cultivation house, it is essential to reduce the overall operating time of the inlet fan, outlet fan, and humidifier, while simultaneously appropriately manage the internal environment by using a unit cooler and an air circulation fan.

Flame and Carbonization Patterns of Animal-Origin Foods Ignited by Overheating (과열에 의해 발화된 동물성 식품의 화염 및 탄화 패턴에 관한 연구)

  • Lee, Jeong-Hun;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.126-131
    • /
    • 2019
  • Real-scale fire tests were performed on animal-origin foods using a gas stove with no overheating prevention device. When the animal-origin foods were ignited, a large quantity of white smoke and steam was generated from them; however, when they became dry and began to carbonize, a dark smoke was generated. Even after the gas stove was overheated for more than 5400 s, mackerel, pollack, chicken, etc., did not ignite. However, pork, beef, and tuna caught fire after 2643 s, 2819 s, and 6492 s of heating, respectively. The flame patterns of animal-origin foods were in the forms of a mixed laminar flow and a turbulent flow, and a halo pattern was produced. A sand glass form of the flame pattern was generated when a kitchen hood was operated, but a triangular flame pattern was produced when the kitchen hood was not operated. When the tuna in the pot was overheated, it spontaneously ignited after 6492 s, with the surface temperature of the kitchen hood rapidly rising to 464.5 ℃. Moreover, the temperature at the back of the pot, which was 6 cm away from the outer surface of the upper part of the pot, was 869 ℃ after 6660 s because of the radiant heat. The flame formed a sand glass pattern on the kitchen wall. When the kitchen hood was not operated, or when the flame grew lower than the height of the ceiling, a triangular pattern was formed.

Retraction: A numerical study on the fire smoke behavior by operating the fire prevention system in tunnel-type structure (논문 취소: 터널형 구조물의 방재시설 가동에 따른 화재연기 거동에 관한 수치 해석적 연구)

  • Lee, Ho-Hyung;Choi, Pan-Gyu;Lee, Sang-Don;Heo, Won-Ho;Jo, Jong-Bok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.1
    • /
    • pp.189-199
    • /
    • 2019
  • In this study, behaviors of fire smoke in the operation of disaster prevention facilities (smoke damper, jet fan) in a tunnel-type structure (soundproof tunnel) were investigated numerically and results of the investigation were compared and analyzed. Through the simulation and analysis, it was found that there was a significant change in the patterns of fire smoke between the opening of the ceiling of a fire vehicle and the closing, and it was shown that the critical temperatures of PC and PMMA, main materials of a soundproof tunnel were not exceeded. In addition, the simulation of installation intervals of smoke dampers showed that the maximum temperature of a soundproof tunnel without smoke dampers was $552^{\circ}C$ while it reached $405^{\circ}C$ when smoke dampers were installed at the installation interval of 50 m. The simulation of the operation of a jet fan showed that the maximum temperature of a soundproof tunnel without a jet fan was $549^{\circ}C$ while it reached only $86^{\circ}C$ when a jet fan was operating. Therefore, it is highly expected that they could create a favorable environment for evacuation and protection of soundproofing materials, and it would be necessary to promote basic studies on tunnels serving various functions and purposes.

Effects of Different Ventilation Systems on Rearing Growing-finisher and Indoor Environment in a High Rise Hog Building (고상식 돈사내에서 환기시스템별 환경조사 및 육성비육돈 사육 효과)

  • Yoo, Y.H.;Jeong, J.W.;Park, K.H.;Song, J.I.;Ko, Y.G.;Kim, S.W.;Lee, I.B.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.193-204
    • /
    • 2010
  • The goal of this study was to develop a high-rise hog building(HRHB) for growing-fattening stages. HRHB was two story building and was suitable for specific environment in Korea. Manure was treated in a first floor and pigs were raised on the slatted second floor. Three ventilation systems - 1) duct inlet to wall exhaust system(V1), 2) eave inlet to wall exhaust system(V2), and 3) ceiling inlet to wall exhaust system(V3) - were used. This experiment was conducted during winter and from summer to fall. Air temperature, air speed, ammonia, hydrogen sulfide in HRHB, and swine growth rate were measured. During winter, air temperature in V1 system tended to be slightly high without any effect of outside air temperature. Maximum temperature from summer to fall was between 33.4 and $33.8^{\circ}C$ and there was no significant difference among systems. Continuously measured daily temperature was lower in V2 system than other systems and the fluctuation of air temperature was high. Air speed in V1 and V2 systems were similar (0.02~0.21 m/s), and was 0.04~0.15 m/s in V3 during winter. From summer to fall, air speed in V1, V2, and V3 systems were 0.10~0.41 m/s, 0.10~0.83 m/s, and 0.11~0.26 m/s, respectively. V2 system showed bigger fluctuation of air speed than other systems. During winter, the highest concentrations of ammonia in V1, V2, and V3 systems were 7.0, 3.5, and 8.7 ppm, respectively. Hydrogen sulfide was not detected. The highest concentrations of ammonia from summer to winter in V1, V2, and V3 systems were 6.1, 2.8, and 5.6 ppm, respectively. Swine growth showed no statistical significance among systems. However, daily weight gain was approximately 4% higher in V1 and V3 than in V2. Feed intake/daily weight gain was approximately 4% higher in V1 than other systems. From summer to fall, daily weight gain in V1 and V3 tended to approximately 3% higher than other systems, and feed intake/daily weight gain was approximately 2% higher in V1 than other systems. Hence, V2 system for the ventilation system of HRHB should not be utilized.

Assessment on Thermal Transmission Property of Wall Through a Scaled Model Test (축소모형 실험을 통한 벽체의 열관류 측정)

  • Chang, Yoon-Seong;Kim, Sejong;Shim, Kug-Bo;Lee, Sang-Joon;Han, Yeonjung;Park, Yonggun;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.884-889
    • /
    • 2015
  • Appropriate evaluation of thermal insulation property of structural member and valid control of cooling/heating energy are important for improving building's energy efficiency. The typical heating system of house in Korea is the floor heating one. The radiation heating system is not only appropriate to climate and geographic conditions of Korea, but also advantageous to provide emotional comfort by the warm feeling of floor. Based on living conditions in Korea, scaled models of the wooden house and concrete house were designed. The ceiling was made of styrofoam insulation and the four sided walls and bottom were made of plywood and concrete, respectively. The floor was heated by heating film. Indoor vertical temperature distributions by floor heating system were measured by thermocouple, and surface temperatures on walls were measured by infrared thermography. Also, thermal insulation property of wooden wall was evaluated to build database for improving energy efficiency of wooden building. It is expected that collected data during tests of various types of floor and wall composition could be referenced for evaluating thermal environment of actual conditions of houses.