• 제목/요약/키워드: Temperature measurement

검색결과 4,998건 처리시간 0.028초

음향파의 위상 추정을 이용한 실리콘 웨이퍼의 온도 측정 (Temperature Measurement of Silicon Wafers Using Phase Estimation of Acoustic Wave)

  • Joonhyuk Kang;Lee, Seokwon
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권11호
    • /
    • pp.493-495
    • /
    • 2003
  • Accurate temperature measurement is a key factor to implement the rapid thermal processing(RTP). A temperature estimation method using acoustic wave has been proposed to overcome the inaccuracy and contamination problem of the previous methods. The proposed method, however, may suffer from the offset and low resolution problem since it is implemented in the time domain. This paper presents a temperature estimation method using the phase detection of acoustic wave. Based on the frequency domain approach, the proposed technique increases the resolution of the measured temperature and reduces the effect of noise. We investigate the performance of the proposed method via experiments.

LED 기생 커패시턴스를 고려한 접합온도 측정 시스템의 개선 (Improvement the Junction Temperature Measurement System Considering the Parasitic Capacitance in LED)

  • 박종연;유진완
    • 산업기술연구
    • /
    • 제29권B호
    • /
    • pp.187-191
    • /
    • 2009
  • Recently, we have used LEDs to illumination because it has a high luminous efficiency and prolong lifespan. However the light power and lifetime is reduced by junction temperature increment of LED. So it is important to measure the junction temperature accurately. In case of using a electrical method measuring junction temperature of LED. Temperature measurement errors are spontaneously generated because of a parasitic capacitances in LED. In this paper, we proposed a method that reducing LED's parasitic capacitance effects for electrical measurement. It was demonstrated by the experimental result that is more correct than established method.

  • PDF

온돌난방주택의 난방방식별 열 특성에 관한 실험연구 (Experimental Study on the Thermal Characteristics in Ondol Heating Systems)

  • 윤정숙
    • 한국주거학회논문집
    • /
    • 제1권1호
    • /
    • pp.91-102
    • /
    • 1990
  • The aim of this study is to discover thermal characteristics of Ondol heating systems. The housing subjected was categorized into detached single family houses and apartments, reinforced concrete and brick structures, intermittent and continous heating system, and the space subjected was bedroom. In order to understand the thermal characteristics of each floor heating systems, the vertical distribution of indoor temperature and the distribution of surface temperature on the floor were measured. The vertical distribution of indoor temperature except the measurement point 1 largely showed average temperature distribution, and the temperature of the measurement point 1 in the housing surveyed showed the highest temperature in the house "sample A" because of the radiation heating from the floor of the Ondol room. As the result of the measurement, the thermal characteristics of each heating system were more stable distribution in apartments of R.C structure.structure.

  • PDF

Estimation of Insulated-gate Bipolar Transistor Operating Temperature: Simulation and Experiment

  • Bahun, Ivan;Sunde, Viktor;Jakopovic, Zeljko
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.729-736
    • /
    • 2013
  • Knowledge of a power semiconductor's operating temperature is important in circuit design and converter control. Designing appropriate circuitry that does not affect regular circuit operation during virtual junction temperature measurement at actual operating conditions is a demanding task for engineers. The proposed method enables virtual junction temperature estimation with a dedicated modified gate driver circuit based on real-time measurement of a semiconductor's quasi-threshold voltage. A simulation was conducted before the circuit was designed to verify the concept and to determine the basic properties and potential drawbacks of the proposed method.

인광입자(Sr,Mg)2SiO4:Eu2+를 이용한 액체의 온도장 측정에 관한 연구 (Study on Temperature Field Measurement of Fluid using Phophor Particle (Sr,Mg)2SiO4:Eu2+)

  • 송동진;이현창
    • 한국가시화정보학회지
    • /
    • 제17권3호
    • /
    • pp.59-65
    • /
    • 2019
  • Phosphor particles ((Sr,Mg)2 SiO4:Eu2+ were suspended in deionized water in quartz cuvette and used for measuring liquid temperature field by using two-color-ratio method. In the temperature range of 23~77℃, it showed the relative error from 2.4% to 4% and the temperature sensitivity of 0.65 %/℃ at 30℃ and 0.95 %/℃ at 77 ℃. This performance is comparable to measurement techniques using thermographic liquid crystal or laser induced fluorescence or other thermographic phosphor particle. Among investigated potential error sources, the particle number density affected the intensity ratio and the temperature, but the effect of laser fluence was not evident.

온도변화에 따른 백금 실리사이드-엔 실리콘 접합의 전자 터널링 특성 (Electron Tunneling Characteristics of PtSi-nSi Junctions according to Temperature Variations)

  • 장창덕;이정석;이광우;이용재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.87-91
    • /
    • 1998
  • In this paper, We analyzed the current-voltage characteristics with n-type silicon substrates concentration and temperature variations (Room temperature, 50$^{\circ}C$, 75$^{\circ}C$) in platinum silicide and silicon junction. The electrical parameters of measurement are turn-on voltage, saturation current, ideality factor, barrier height, dynamic resistance in forward bias and reverse breakdown voltage according to variations of junction concentration of substrates and measurement temperature variations. As a result, the forward turn-on voltage, reverse breakdown voltage, barrier height and dynamic resistance were decreased but saturation currents and ideality factor were increased by substrates increased concentration variations in platinum silicide and n-silicon junction. In increased measurement temperature (RT, 50$^{\circ}C$, 75$^{\circ}C$), the extracted electrical parameter values of characteristics were rises by increased temperature variations according to the forward and reverse bias.

  • PDF

고온 피로균열 성장거동 관찰을 위한 코팅기술의 응용 (Application of Coating Technique for Measurement of Elevated Temperature Fatigue Crack Growth Behavior)

  • 남승훈;김용일;서창민;김동석
    • 한국해양공학회지
    • /
    • 제16권2호
    • /
    • pp.60-66
    • /
    • 2002
  • The remote measurement system(RMS) as a new experimental method is limited in its application to crack measurement at elevated temperatures because of the oxide layer on the specimen surface. Since TiAIN and Cr coating layers have a high resistance to oxidation and wear, this paper proposed a TiAIN and Cr coating technique for specimens to facilitate the measurement of crack growth behavior using RMS. To investigate the effects of the coating layer, tension and fatigue tests were carried out at room temperature and at $538^{\circ}C$. The test material was 1Cr-1Mo-0.25V steel which is widely used as a turbine rotor material. From the experimental results, it was found that the mechanical properties of the TiAIN and Cr coated specimens were similar to those of the substrate. Accordingly, the TiAIN and Cr coated layer had hardly any influence on the fatigue crack propagation.

고막체온과 액와체온의 비교 연구 - 성인대상자를 중심으로 - (Comparison of Tympanic and Axillary Temperatures)

  • 유재희;조현숙
    • 기본간호학회지
    • /
    • 제16권2호
    • /
    • pp.162-170
    • /
    • 2009
  • Purpose: To verify the usability of tympanic temperature measurement for adults, a comparison of tympanic and axillary temperatures was done. Method: The study was conducted during October 2008, and participants were 110 female nursing students. Axillary temperatures were taken with glass mercury thermometers for 5, 7 and 10 minutes. Tympanic temperatures were taken with Infrared Thermometer IRT 4520 on both ears, twice at a 5-second interval. The data were analyzed using the SPSS 12.0 program. Results: In the 1st measurement, the mean for right tympanic temperatures ($0.06^{\circ}C$) and for left ($0.03^{\circ}C$) were significantly higher than the 2nd. A comparison of mean temperatures for right and left, showed that the mean for the left side on the 1st measurement was significantly higher ($0.01^{\circ}C$) than the right. Also the temperature on left side in the 2nd measurement was higher ($0.04^{\circ}C$) than the right 2nd, but not significantly higher. The mean temperature for right and left tympanic on 1 st and 2nd measurements were significantly higher than axilla for 5 minutes ($0.58^{\circ}C$), for 7 minutes ($0.52^{\circ}C$), and for 10 minutes ($0.43^{\circ}C$). The tympanic temperature was the most closely correlated with the axillary temperature at 10 minutes. Conclusion: Findings indicate that measurement of tympanic temperature is a useful alternative to axillary temperature taken for 10 minutes.

  • PDF

비접촉식 온도센서 어레이를 활용한 온도 계측시스템 개발 (The Development of Temperature Measurement System using Non-Contact Temperature Sensor Array)

  • 김성대
    • 한국정보통신학회논문지
    • /
    • 제19권9호
    • /
    • pp.2087-2092
    • /
    • 2015
  • 산업이 발전함에 따라 제조업 및 서비스 제품 등 다양한 분야에 열전달 장치 및 열전달 시스템이 활용되고 있다. 열전달 시스템의 자동화 및 모니터링 시스템을 통하여 환경을 관리하기 위해서는 온도 측정이 필요한 대상물의 직접적인 온도 및 측정 대상물의 주위 온도에 대한 계측이 필수요소라 할 수 있다. 특히, 이러한 온도 측정에 관한 두 가지 요소에 대하여 본 논문에서는 비접촉온도센서를 활용하여 온도 계측이 필요한 대상물에 센스를 직접 접촉하지 않고 대상물의 표면 온도를 계측할 수 있는 시스템과 대상물 주위 온도를 계측할 수 있는 모듈을 소형 MCU(microcontroller unit) 기반으로 설계하여 계측된 온도 데이터를 USN(Ubiquitous Sensor Network)기반의 지그비(ZigBee) 통신을 활용하여 온도 모니터링 시스템을 제시하고자 한다. 본 논문에서는 대상물의 온도와 주위 온도에 관한 정보를 계측하기 위하여 비접촉온도센서를 활용하여 대상물의 표면 온도 및 주위 온도를 계측할 수 있는 펌웨어 기반의 시스템을 설계하였다. 또한, 계측된 온도 정보 데이터를 지그비 통신을 기반으로 원격으로 온도 데이터를 모니터링 할 수 있는 시스템을 제시하고자 한다.

동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구 (Study on the Partially Premixed Flames Produced by a Coflow Burner as Temperature Calibration Source)

  • 박철웅;한재원;신현동
    • 한국연소학회지
    • /
    • 제5권1호
    • /
    • pp.91-98
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a co flow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.

  • PDF