• Title/Summary/Keyword: Temperature measurement

Search Result 4,995, Processing Time 0.037 seconds

Characteristic Analysis of Transformer Temperature for High Speed Train (고속철도차량의 변압기 온도 특성 분석)

  • Han, Young-Jae;Kim, Ki-Hwan;Kim, Yeong-Guk;Park, Chun-Su;Kim, Seog-Won;Mok, Jin-Yong;Lee, Su-Gil;Lee, Seong-Ho;Kim, Jong-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1595-1597
    • /
    • 2005
  • In this study, temperature sensors were adhered to transformer that is used in KHST(Korean High-Speed Train) to verify variation of temperature characteristics about transformer synthetically and efficiently. In the case that temperature of transformer exceeds reference temperature for running of KHST, overheating of transformer may cause a fatal accident of vehicle. Therefore, after on-line measurement system was constructed in vehicle, oil temperature and tank temperature were measured on real-time. Characteristics and main specifications of transformer in KHST were described in this paper. Also, measurement system for temperature measurement of transformer was explained in brief. Temperature data of transformer was acquired using measurement system, KHRI(Korea Railroad Research Institute) analyzed characteristic in contrast with comparing with temperature of transformer about month, running speed and running time.

  • PDF

Study on the partially premixed flames produced by a coflow burner as temperature calibration source (동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구)

  • Park, Chul-Woung;Hahn, Jae-Won;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.160-167
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a coflow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.

  • PDF

Research on Measurement of Infrared Thermograpphy under High Temperature Condition (고온 환경에서의 적외선 열화상 측정에 관한 연구)

  • Jun-Sik Lee;Jae-Wook Jeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2024
  • This study conducted a measurement method of high temeprature conditions using infrared termography. All objects emit infrared light, and this emissivity has a significant impact on the temperature measurements of infrared thermal imaging (IR) cameras. In order to measure the temperature more accurately with the IR camera, correction equations were derived by measuring the emissivity according to the temperature change of combustible metals in a high-temperature environment. Two combustible metals, Mg and Al, were used to measure emissivity with changing temperature. Each metal was heated, the emissivity was measured by comparing the temperature with IR camera and thermocouples so that the correlation between temperature and emissivity could be anslyzed. As a result of the experiment, the emissivity of the metals increases as the temperature increased. This can be interpreted as a result of increased radiation emission as the thermal movement of internal metal molecules increased.

Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method (원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발)

  • Ryu, Jae-Kyu;Sohn, Chang-Ho;Hwang, Hee-Jung;Kim, Gun-Soo;Choi, Kyong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

A Study on Mechanical Measurement of Motor and Transformer for Korean High-Speed Train

  • Han, Young-Jae;Kim, Seog-Won;Seo, Sung-Il;Kim, Young-Guk;Park, Choon-Soo;Lee, Su-Gil;Kim, Jong-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1720-1723
    • /
    • 2003
  • Recently, as the road capacity reaches a limit and environmental problems becomes serious, there exists a gradually increased need for railway vehicles that are environment-friendly, punctual, reliable and safe. Accordingly, in addition to conventional railroad vehicles, lots of vehicles are being newly developed. Korean High Speed Train has been developed for last 6 years to satisfy the need. Authors developed a measurement system for on-line test and evaluation of performances of Korean High-Speed Train. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A new method to measure temperature was applied to the measurement system. By using the system, measurement and evaluation of the mechanical characteristics of motors and main transformers in Korean High Speed Train was conducted during test running. The measured results for the temperature characteristics of electric devices verify that the measurement system is accurate and reliable.

  • PDF

Development of a multi-sensing technique for temperature and strain field of high-temperature using thermographic phosphors (온도감응형 인광물질을 이용한 온도장 및 열변형 동시 계측 기법 개발)

  • Im, Yujin;Yeom, Eunseop
    • Journal of the Korean Society of Visualization
    • /
    • v.19 no.3
    • /
    • pp.77-83
    • /
    • 2021
  • Solid oxide fuel cell (SOFC) operates at high temperatures in range of 600-800℃. Since layers of SOFC are composed of different substances, different thermal expansion in SOFC can result in defects under high temperature conditions. For understanding relation between temperature field and the thermal deformation in SOFC, temperature and strain field were simultaneously estimated using thermographic phosphors by optical measurement. Temperature fields were obtained by the life-time method, and the temperature differences of one specimen was checked with thermocouple. The thermal deformation was estimated by digital image correlation (DIC) method with extracted phosphorescence images. To investigate the deformation accuracy of DIC measurement, thermographic phosphors were coated with and without grid pattern on aluminum surface. Simultaneous measurement of temperature fields and thermal deformation were carried out for YSZ. This study will be helpful to multi-sensing of temperature field and thermal deformation on SOFC cells.

Investigation of an Infrared Temperature Measurement System for Thermal Safety Verification of Plasma Skin Treatment Devices

  • Choi, Jong-ryul;Kim, Wookeun;Kang, Bongkeun;Song, Tae-Ha;Baek, Hee Gyu;Han, Yeong Gil;Park, Jungmoon;Seo, Soowon
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.500-504
    • /
    • 2017
  • In this paper, we developed a temperature measurement system based on an infrared temperature imaging module for thermal safety verification of a plasma skin treatment device (PSTD). We tested a pilot product of the low-temperature PSTD using the system, and the temperature increase of each plasma torch was well-monitored in real-time. Additionally, through the approximation of the temperature increase of the plasma torches, a certain limitation of the plasma treatment time on skin was established with the International Electrotechnical Commission (IEC) guideline. We determined an appropriate plasma treatment time ($T_{Safe}$ < 24 minutes) using the configured temperature measurement system. We believe that the temperature measurement system has a potential to be employed for testing thermal safety and suitability of various medical devices and industrial instruments.

The calculation and Measurement Methods for G/T of the Telemetry Small Aperture Antenna (원격자료수신장비 소형반사판 안테나 G/T 예측 및 측정)

  • Kim, Chun-Won;An, Na-Gyun;Kim, Dong-Hyun;Cho, Byung-Lok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.9
    • /
    • pp.657-662
    • /
    • 2022
  • In this paper, the calculation using simulation and two measurement methods for G/T of the telemetry are analyzed. Antenna gain and noise temperature are calculated by using ICARA and Antenna Noise Temperature Calculator. System G/T were calculated by using Antenna gain/noise temperature, LNA gain/noise temperature, cable loss. The first G/T measurement method is Y-factor measurement method, which is to calculate G/T by comparing LNA noise temperature and a signal level difference when an antenna and a 50ohm termination are respectively connected to an LNA input terminal Second method is Solar calibration measurement method that is to calculate G/T by comparing noise level difference when looking at the sun and lowest level point. Finally, the accuracy was reviewed by comparing the G/T calculation results with the two measurement methods, and the optimal measurement method according to antenna performance and operating environment was presented.

Hot Leg Temperature Uncertainty due to Thermal Stratification

  • Jang, Ho-Cheol;Ju, Kyong-In;Kim, Young-Bo;Sul, Young-Sil;Cheong, Jong-Sik
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.29-35
    • /
    • 1996
  • For the Reactor Coolant System(RCS) flow rate measurement by the secondary calorimetric heat balance method, the coolant temperature of the hot leg is needed. Several Resistance Temperature Detectors(RTD) are installed in the hot leg to measure the temperature, but the average value of RTDs does not correctly represent the energy-averaged(bulk) temperature because of the thermal stratification phenomenon. Therefore some correction is introduced to predict the bulk temperature, but the correction inevitably contains uncertainty because the stratification is not defined well quantitatively yet. Therefore a large uncertainty for the correction has been used for the conservative estimation. But unrealistically large uncertainty causes degradation of the measurement method and yields difficulty to meet the acceptance criterion in start-up flow measurement test. In this paper, an analytical estimation is made on the correction and the related uncertainty using the measured hot leg velocity profile of System 80 reactor flow model test and the measured temperatures of YGN 3&4 and PVNGS 1&2 start-up tests. The results reveal that the magnitude of the correction uncertainty is much smaller than that used in the previous design. Therefore, the confidence on the flow rate measurement method can be improved and the difficulty in start-up flow measurement test can be lessened if the smaller correction uncertainty obtained through this estimation is applied.

  • PDF

A Study on Non-contact Surface Temperature Field Measurement of a Body Immerged in Water Using Thermographic Phosphor Thermometry (열감지인광온도계를 이용한 물에 잠긴 물체 표면 온도장의 비접촉식 측정에 관한 연구)

  • Park, Yoonseong;Cai, Tao;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.61-68
    • /
    • 2020
  • Thermographic phosphor (TP) thermometry is a noncontact optical measurement method and has been applied in many fields such as combustion and heat transfer. However, due to the limitation of bonding technology and measurement method, most TP thermometry studies were conducted only on the air environment with water-soluble binders. In this paper, a temperature measurement technology in water using TP is proposed by coatings of manganese activated magnesium fluorogermanate (Mg4FGeO6:Mn4+, MFG) with Polydimethylsiloxane (PDMS). Four MFG-PDMS coatings with different thicknesses were prepared. The lifetime of MFG was not affected by the thickness of the coating as a result of the experiment and analysis of phosphor intensity using a photomultiplier tube. To measure the surface temperature field of an immerged body in water, a cylinder-type cartridge heater was coated with MFG doped PDMS. Transient surface temperature field was successfully measured even the initial temperature is higher than the boiling point of water.