Proceedings of the KIEE Conference (대한전기학회:학술대회논문집)
- 2005.07b
- /
- Pages.1595-1597
- /
- 2005
Characteristic Analysis of Transformer Temperature for High Speed Train
고속철도차량의 변압기 온도 특성 분석
- Han, Young-Jae (Korea Railroad Research Institute) ;
- Kim, Ki-Hwan (Korea Railroad Research Institute) ;
- Kim, Yeong-Guk (Korea Railroad Research Institute) ;
- Park, Chun-Su (Korea Railroad Research Institute) ;
- Kim, Seog-Won (Korea Railroad Research Institute) ;
- Mok, Jin-Yong (Korea Railroad Research Institute) ;
- Lee, Su-Gil (Korea Railroad Research Institute) ;
- Lee, Seong-Ho (Korea Railroad Research Institute) ;
- Kim, Jong-Young (Korea Railroad Research Institute)
- 한영재 (한국철도기술연구원) ;
- 김기환 (한국철도기술연구원) ;
- 김영국 (한국철도기술연구원) ;
- 박춘수 (한국철도기술연구원) ;
- ;
- ;
- 이수길 (한국철도기술연구원) ;
- 이성호 (한국철도기술연구원) ;
- Published : 2005.07.18
Abstract
In this study, temperature sensors were adhered to transformer that is used in KHST(Korean High-Speed Train) to verify variation of temperature characteristics about transformer synthetically and efficiently. In the case that temperature of transformer exceeds reference temperature for running of KHST, overheating of transformer may cause a fatal accident of vehicle. Therefore, after on-line measurement system was constructed in vehicle, oil temperature and tank temperature were measured on real-time. Characteristics and main specifications of transformer in KHST were described in this paper. Also, measurement system for temperature measurement of transformer was explained in brief. Temperature data of transformer was acquired using measurement system, KHRI(Korea Railroad Research Institute) analyzed characteristic in contrast with comparing with temperature of transformer about month, running speed and running time.