• Title/Summary/Keyword: Temperature Monitor

Search Result 683, Processing Time 0.025 seconds

Modelization and Optimization of Quality Characteristics of Pork Treated Various Hydrostatic Pressure Conditions

  • Hong, Geun-Pyo;Chun, Ji-Yeon;Lee, Si-Kyung;Choi, Mi-Jung
    • Food Science of Animal Resources
    • /
    • v.32 no.3
    • /
    • pp.274-284
    • /
    • 2012
  • In this study, the effects of physical parameters (30-270 MPa of pressure, 3-57 min of time, and 1-$49^{\circ}C$ of temperature) on pork quality were investigated. Response surface methodology was used in order to monitor and model the changes in pork quality under varied pressure conditions. As quality characteristics, shear force, water holding capacity (WHC) and the CIE color of pork were measured, and optimum pressure conditions were evaluated by statistical modeling. Pressure improved the WHC of pork at relatively low temperature ($<25^{\circ}C$); however, the opposite occurred with increasing temperature. Although pressure and temperature affected the tenderness of the meat, interaction effects among variations were not observed. At pressure levels higher than 200 MPa, the color of pork differed markedly from that of the untreated controls. In particular, differential scanning calorimetry (DSC) revealed marked evidence of myosin denaturation. The present study demonstrates that pork quality varies depending on pressure conditions.

Electro-optical Characteristics of LED Flat Light Source in Low Temperature Condition (LED 평판조명의 저온환경에서의 전기광학특성)

  • Han, Jeong-Min;Seo, Dae-Shik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.61-65
    • /
    • 2011
  • Recently, LCD (liquid crystal display) industry is needed to goods of high reliability and wide range temperature condition and it is interested in products for extremely cold condition without failure of light-up. In this experiment, we made the LED backlight unit for Automotive-navigation under the extremely cold condition. And for making this backlight unit, we used to eight side emitting type white LEDs with 3W high power LED. We could know that this backlight unit releases to 18,000 nit in 24W power consumption and start up voltage time is under the 1ms in the ambient temperature at -40.

Development and Implementation of an Over-Temperature Protection System for Power Semiconductor Devices (전력용 반도체 소자의 과열보호시스템 설계 및 구현)

  • Choi, Nak-Gwon;Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.163-168
    • /
    • 2010
  • This paper presents the practical implementation of an over-temperature protection system for power semiconductor devices. In the proposed system, temperature variation is provided with just using $R_{ds(on)}$ characteristics of power MOSFET, while extra device such as a temperature sensor or an over-temperature detection transistor is needed to monitor the temperature in the conventional method. The proposed protection technique is experimentally tested on IRF840 power MOSFET. The PIC microcontroller PIC16F877A is used for the implementation of the proposed protection algorithm. The built-in 10-bit A/D converter is utilized for detecting voltage variance between a drain and a source of IRF840. The induced temperature-resistance relationship based on the measured drain-source voltage, supplies a gate signal to the power MOSFET. If detected temperature's voltage exceeds any a protection temperature's voltage, the microcontroller removes the trigger signal from the power MOSFET. These test results showed satisfactory performances of the proposed protection system in term of accuracy within 1.5%.

A study on sensing for abnormality of BUS BAR in motor control center (모터컨트롤센터의 BUS BAR 이상 감지를 위한 실험적 연구)

  • Kim, Sung-Dae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5838-5842
    • /
    • 2011
  • The study mainly aims to explore how deterioration of motor control center, namely MCC, and vibration put impact on temperature of bus bar as well as temperature change of bolt-nut joint. The motor control center consists of three internal parts (i.e. R, S, T) which are for motor operation of high capacity. Two dimensional mechanism for measuring temperature was designed and manufactured with infrared temperature sensor. Installing it in inner motor control center enabled researcher to monitor temperature of bus bar as well as amount of change of current regularly. Temperature change of bus bar according to load was primarily examined based on a bolted joint in the experiment. It was clearly verified that temperature change of bus bar was proportional to current consumption. Therefore, installing non-contact two dimensional mechanism for measuring temperature in motor control center would be expected to prevent temperature rise owing to overload current and power outage as well as fire accident which can be triggered by poor electrical contact.

A Real Time Temperature Monitoring System for Plating Process (도금공정 실시간 원격 온도 모니터링 시스템)

  • Jung, Sun-Wung;Choi, Tae-Lin;Yoo, Woosik;Kim, Byung Soo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.72-79
    • /
    • 2015
  • A number of plating companies have been exposed to the risk of fire due to unexpected temperature increasing of water in a plating bath. Since the companies are not able to forecast the unexpected temperature increasing of water and most of raw materials in the plating process have low ignition temperature, it is easy to be exposed to the risk of fire. Thus, the companies have to notice the changes immediately to prevent the risk of fire from plating process. Due to this reason, an agile and systematic temperature monitoring system is required for the plating companies. Unfortunately, in case of small size companies, it is hard to purchase a systematic solution and be offered consulting from one of the risk management consulting companies due to an expensive cost. In addition, most of the companies have insufficient research and development (R&D) experts to autonomously develop the risk management solution. In this article, we developed a real time remote temperature monitoring system which is easy to operate with a lower cost. The system is constructed by using Raspberry Pi single board computer and Android application to release an economic issue for the small sized plating manufacturing companies. The derived system is able to monitor the temperature continuously with tracking the temperature in the batch in a short time and transmit a push-alarm to a target-device located in a remoted area when the temperature exceeds a certain hazardous-temperature level. Therefore, the target small plating company achieves a risk management system with a small cost.

Monitoring System of Rock Mass Displacement and Temperature Variation for KURT using Optical Sensor Cable (광섬유센서케이블을 이용한 지하연구시설의 지반변위 및 온도변화 감시시스템 구축)

  • Kim, Kyung-Su;Bae, Dae-Seok;Koh, Yong-Kwon;Kim, Jung-Yul
    • The Journal of Engineering Geology
    • /
    • v.19 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The optical fiber cable acting as a sensor was embedded in the underground research tunnel and portal area in order to monitor their stability and the spatial temperature variation. This system includes two types of sensing function to monitor the distributed strain and temperature along the line, where sensor cable is installed, not a point sensing. According to the results of one year monitoring around the KURT, there is no significant displacement or movement at the tunnel wall and portal slope. However, it would be able to aware of some phenomena as an advance notice at the tunnel wall which indicates the fracturing in rockmass and shotcrete fragmentation before rock falls accidently as well as movement of earth slope. The measurement resolution for rock mass displacement is 1 mm per 1 m and it covers 30 km length with every 1m interval in minimum. In temperature, the cable measures the range of $-160{\sim}600^{\circ}C$ with $0.01^{\circ}C$ resolution according to the cable types. This means that it would be applicable to monitoring system for the safe operation of various kinds of facilities having static and/or dynamic characteristics, such as chemical plant, pipeline, rail, huge building, long and slim structures, bridge, subway and marine vessel. etc.

High Speed Response Time of Nematic Liquid Crystal Mixtures for LCD Monitor and TV Applications

  • Kim, Y.B.;Hur, I.K.
    • Journal of Information Display
    • /
    • v.2 no.3
    • /
    • pp.32-38
    • /
    • 2001
  • The most important parameter for TV application of LCD is a fast switching time for the display of moving image. To achieve faster switching time, the novel LC single materials with large dielectric anisotropies ($16{\sim}20$), high clearing temperatures ($195.5{\sim}237.4^{\circ}C$), broad nematic ranges (up to 169.9 $^{\circ}C$) and high birefringence ($0.254{\sim}0.2200$) were developed. KUR-series LC mixtures blended these single materials having significantly higher clearing temperatures and dielectric anisotropy values compared with conventional LC mixture. Especially, their clearing temperatures are $10{\sim}30^{\circ}C$ higher than their host mixture. These LC mixtures showing about lOms of high-speed switching time in Tv/Monitor of TFT LCD, is short enough to be addressed in a single time frame of 60Hz (16.7 ms). The threshold voltage $V_{th}$ was low enough to operate at a driving voltage of 5 V. The VHR values were found to be high enough for TFT-LCD in wide temperature range. Our novel LC mixtures are suitable materials for the inclusion in to LC mixtures for TV application of TN-LCD

  • PDF

Fundamental Research on Spring Season Daytime Sea Fog Detection Using MODIS in the Yellow Sea

  • Jeon, Joo-Young;Kim, Sun-Hwa;Yang, Chan-Su
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.4
    • /
    • pp.339-351
    • /
    • 2016
  • For the safety of sea, it is important to monitor sea fog, one of the dangerous meteorological phenomena which cause marine accidents. To detect and monitor sea fog, Moderate Resolution Imaging Spectroradiometer (MODIS) data which is capable to provide spatial distribution of sea fog has been used. The previous automatic sea fog detection algorithms were focused on detecting sea fog using Terra/MODIS only. The improved algorithm is based on the sea fog detection algorithm by Wu and Li (2014) and it is applicable to both Terra and Aqua MODIS data. We have focused on detecting spring season sea fog events in the Yellow Sea. The algorithm includes application of cloud mask product, the Normalized Difference Snow Index (NDSI), the STandard Deviation test using infrared channel ($STD_{IR}$) with various window size, Temperature Difference Index(TDI) in the algorithm (BTCT - SST) and Normalized Water Vapor Index (NWVI). Through the calculation of the Hanssen-Kuiper Skill Score (KSS) using sea fog manual detection result, we derived more suitable threshold for each index. The adjusted threshold is expected to bring higher accuracy of sea fog detection for spring season daytime sea fog detection using MODIS in the Yellow Sea.

Application of Acoustic Emission Technique for On-Line Monitoring of Quench in Racetrack Superconducting Coil at Cryogenic Environment (음향방출기법을 이용한 극저온 환경하에서 초전도 계자코일의 퀀칭탐지 적용에 관한 연구)

  • Lee, Min-Rae;Gwon, Yeong-Gil;Lee, Jun-Hyeon;Son, Myeong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.858-865
    • /
    • 2000
  • It is well recently recognized that quench is one of the serious problems for the integrity of superconducting magnets, which is mainly attribute to the rapid temperature rising in the magnet due to some extrinsic factors such as conductor motion, crack initiation etc. In order to apply acoustic emission(AE)echnique effectively to monitor and diagnose superconducting magnets, it is essential to identify the sources of acoustic emission. In this paper, an acoustic emission technique has been used to monitor and diagnose quenching phenomenon in racetrack shaped superconducting magnets at cryogenic environment of 4.2K. For these purposes special attention was paid to detect AE signals associated with the quench of superconducting magnets. The characteristics of AE parameters have been analyzed by correlating with quench number, winding tension of superconducting coil and charge rate by transport current. In addition, the source location of quench in superconducting magnet was also discussed on the basis of correlation between magnet voltage and AE energy.

DISSOLUTION AND BURNUP DETERMINATION OF IRRADIATED U-Zr ALLOY NUCLEAR FUEL BY CHEMICAL METHODS

  • Kim, Jung-Suk;Jeon, Young-Shin;Park, Soon-Dal;Song, Byung-Chul;Han, Sun-Ho;Kim, Jong-Goo
    • Nuclear Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.301-310
    • /
    • 2006
  • Destructive methods were used for the burnup determination of U-Zr alloy nuclear fuel irradiated in the High-flux Advanced Neutron Application Reactor (HANARO) at KAERI. The dissolution rate of unirradiated U-Zr alloy fuel in $HNO_3$/HF mixtures was investigated for the experimental conditions of a different temperature, and initial concentrations of HF and $HNO_3$. The irradiated U-Zr alloy fuel specimen was dissolved in a mixed acid condition of 3 M HNO3 and 1 M HF at $90^{\circ}C$ for 8 hours under reflux. The total burnup was determined from measurement of the Nd isotope burnup monitors. The method includes U, Pu, $^{148}Nd,\;^P{145}Nd+^{146}Nd,\;^{144}Nd+^{143}Nd$ and total Nd isotopes determination by the isotope dilution mass spectrometric method (IDMS) using triple spikes $(^{233}U,\;^{242}Pu\;and\;^{150}Nd)$. The effective fission yield was calculated from the weighted fission yields averaged over the irradiation period. The results are compared with that obtained by the destructive -spectrometric measurement of the $^{137}Cs$ monitor.