• 제목/요약/키워드: Temperature Load

검색결과 3,066건 처리시간 0.03초

화재하중에 따른 지하생활공간의 화재성상 예측 (Prediction of the Fire Behavior According to the Fire Load in an Underground Life Space)

  • 채한식;석창목;김이성;이지희;김화중
    • 한국화재소방학회논문지
    • /
    • 제21권1호
    • /
    • pp.51-59
    • /
    • 2007
  • 본 연구에서는 대구에 위치한 G 지하생활공간을 대상으로 화재하중에 따른 화재성상을 분석하였다. 화재성상 예측시 화재온도나 화재지속시간을 좌우하는 인자인 화재하중 및 환기계수를 파악하기 위하여, 현장방문을 통하여 가연조건을 조사하고 실의 용도별 가연조건에 대하여 각 재료의 단위발열량을 이용하여 화재하중을 산정하였다. 또한, 산정된 실의 화재하중을 변수로 화재성상분석을 위한 6가지 모델의 축소실험을 행하고 화원의 시간에 따른 온도변화와 화원의 온도상승으로 인한 공간내부로의 열유동 분포를 중심으로 화재성상을 분석하였다.

Design of integral abutment bridges for combined thermal and seismic loads

  • Far, Narges Easazadeh;Maleki, Shervin;Barghian, Majid
    • Earthquakes and Structures
    • /
    • 제9권2호
    • /
    • pp.415-430
    • /
    • 2015
  • Integral abutment bridges have many advantages over bridges with expansion joints in terms of economy and maintenance costs. However, in the design of abutments of integral bridges temperature loads play a crucial role. In addition, seismic loads are readily transferred to the substructure and affect the design of these components significantly. Currently, the European and American bridge design codes consider these two load cases separately in their recommended design load combinations. In this paper, the importance and necessity of combining the thermal and seismic loads is investigated for integral bridges. A 2D finite element combined pile-soil-structure interactive model is used in this evaluation. Nonlinear behavior is assumed for near field soil behind the abutments. The soil around the piles is modeled by nonlinear springs based on p-y curves. The uniform temperature changes occurring at the time of some significant earthquakes around the world are gathered and applied simultaneously with the corresponding earthquake time history ground motions. By comparing the results of these analyses to prescribed AASHTO LRFD load combinations it is observed that pile forces and abutment stresses are affected by this new load combination. This effect is more severe for contraction mode which is caused by negative uniform temperature changes.

지열을 이용한 공조외기부하저감 시스템에 관한 연구 - 공기식 집열기와의 병용에 의한 공조외기부하저감 효과 - (Study on Fresh Air Load Reduction System by Using Geothermal Energy - Reducing Effect of a Fresh Air Load by Combining with Air-heated Solar Collector -)

  • 손원득;이성
    • 설비공학논문집
    • /
    • 제16권12호
    • /
    • pp.1218-1226
    • /
    • 2004
  • This paper presents thermal behaviors and performances of a fresh air load reduction system by using earth tube system combined with air-heated solar collector. The earth tube system reduces a fresh air load by heat exchange with soil throughout the year. In the previous experimental research, it was clarified that the earth tube system was very useful as a fresh air load reduction system. However, since outlet temperature of the fresh air which was heated by earth tube system was below 15$^{\circ}C$ in winter, it is not suitable to introduce the fresh air into the place of residence directly. Therefore, a simulation model using the simple heat diffusion equation was used to examine a rising effect of outlet air temperature in winter by combining with air-heated solar collector. An improvement of annual performance by control of operation is also quantitatively examined. In conclusion, it is confirmed that its performance is improved by control of operation throughout the year and outlet air temperature rose by combining with air-heated solar collector.

An approach for calculating the failure loads of unprotected concrete filled steel columns exposed to fire

  • Wang, Y.C.;Kodur, V.K.R.
    • Structural Engineering and Mechanics
    • /
    • 제7권2호
    • /
    • pp.127-145
    • /
    • 1999
  • This paper deals with the development of an approach for evaluating the squash load and rigidity of unprotected concrete filled steel columns at elevated temperatures. The current approach of evaluating these properties is reviewed. It is shown that with a non-uniform temperature distribution, over the composite cross-section, the calculations for the squash load and rigidity are tedious in the current method. A simplified approach is proposed to evaluate the temperature distribution, squash load, and rigidity of composite columns. This approach is based on the model in Eurocode 4 and can conveniently be used to calculate the resistance to axial compression of a concrete filled steel column for any fire resistance time. The accuracy of the proposed approach is assessed by comparing the predicted strengths against the results of fire tests on concrete filled circular and square steel columns. The applicability of the proposed approach to a design situation is illustrated through a numerical example.

지하거주공간의 연간 열환경에 관한 연구 (A Study on the Yearly Thermal Environmental Characteristics in Underground Space)

  • 정효민;정한식
    • 동력기계공학회지
    • /
    • 제2권3호
    • /
    • pp.27-33
    • /
    • 1998
  • The room temperature and air conditioning load in the underground space have been investigated numerically by the unsteady heat conduction equation. The model room has 3 m in height and 10 m in width, and it's position in the underground depth are 0.5 m to 5 m. When the room was located around surface, the room temperatures were strongly influenced by the atmosphere. But the underground depth is more than 2 m, the yearly temperature amplitude was small and the temperature phase was delayed. Up to 5 m of the depth, the cooling and heating load was decreased rapidly, but over 10 m of the depth, the air conditioning load was constant.

  • PDF

Dynamic responses of laminated beams under a moving load in thermal environment

  • Akbas, Seref D.
    • Steel and Composite Structures
    • /
    • 제35권6호
    • /
    • pp.729-737
    • /
    • 2020
  • The goal of this study is to investigate dynamic responses of laminated composite beams under a moving load with thermal effects. The governing equations of problem are derived by using the Lagrange procedure. The transverse-shear strain and rotary inertia are considered within the Timoshenko beam theory. The material properties of laminas are considered as the temperature dependent physical property. The differential equations of the problem are solved by the Ritz method. The solution step of dynamic problem, the Newmark average acceleration method is used in the time history. A compassion study is performed for accuracy of used formulations and method. In the numerical results, the effects of velocity of moving load, temperature values, the fiber orientation angles and the stacking sequence of laminas on the dynamic responses of the composite laminated beam are investigated.

77K Inertance tube 맥동관 극저온 냉동기에 관한 연구 (An Experimental Study for the 77K Inertance Tube Pulse Tube Cryocooler)

  • 박성제;고득용;김효봉
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.17-27
    • /
    • 1999
  • The experimental results of the 17K inertance tube pulse tube cryocooler for cooling cryosensors are presented in this paper. In prototype experiments, linear compressor is driven by linear motor, and inertance tubes are inserted between one liter reservoir and pulse tube. Design of the inertance tube pulse tube cryo-cooler is conducted by ARCOPTR program of NASA Ames Research Center. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature and refrigeration capacity according to the variations of inertance tube volume, reservoir volume and charging pressure are measured. and the cool down and load characteristics at the particular conditions are presented. As the representative results, no load temperature of the cold end is 52.7K and refrigeration capacity is 5W at 72K..

  • PDF

개발한 국산화 유압 액셜피스톤모터의 특성실험 (Characteristics Experiment of Domestic Developed Hydraulic Axial Piston Motor)

  • 염만오;이상윤
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.70-76
    • /
    • 2007
  • The purpose of this study is to analyze the characteristics of a domestic developed hydraulic axial piston motor. An experimental apparatus was constructed and the output torque, the input oil pressure, the input flow rate, the speed of motor and oil temperature were measured. They were measured under both no load and load conditions. The results are as follows; 1. Motion of motor became steady state conditions after 5 seconds. 2. Output torque of motor was proportional to input oil pressure under both load and unload. 3. Speed of motor decreased with increasing load. 4. Oil temperature was almost constant. The results of this study will offer the basic data in designing and operating hydraulic axial piston motors.

압전특성 및 부하변화에 따른 압전트랜스포머의 전기적 특성 (Electrical Characteristics of the Piezoelectric Transformer as a Function of Piezoelectric Properties and Load Variations)

  • 민석규;윤광희;류주현
    • 한국전기전자재료학회논문지
    • /
    • 제14권4호
    • /
    • pp.289-296
    • /
    • 2001
  • The piezoelectric transformers of 2.0x10x48 ㎣ size were fabricated with PSN-PMN-PZT(T10 and PNW-PMN-PZT(T2) composition ceramics. Effects of micro structural and piezoelectric properties on the electrical characteristics of the piezoelectric transformers were investigated. Under the fixed output power of 6 W, temperature rise of T1 transformer at the optimum load was smaller than T2 one because of fine grain size effect. Voltage step-up ratio of T1 transformer showed higher value than T2 one T1 transformer showed an excellent properties with voltage step-up ratio of 12.41, efficiency of 95.23% and temperature rise of 7.2$^{\circ}C$ at 200㏀ load resistance. And also, T2 transformer showed an excellent properties with voltage step up ratio of 9.81, efficiency of 95.51% and temperature rise of 9$^{\circ}C$ at 150㏀ load resistance.

  • PDF

온도 특성을 고려한 퍼지 선형 회귀 분석 모델 기반 특수일 전력 수요 예측 (A Special-day Load Forecasting with the Characteristics of Temperature based on Fuzzy Linear Regression)

  • 이경진;백영식;송경빈;김문영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.432-434
    • /
    • 2001
  • This paper proposes a special-day load forecasting method with the characteristics of temperature based on fuzzy linear regression. We can obtain a linear regression model from the relation between daily peak load and daily maximum or minimum temperature. Simulation results show that the proposed method can improve an accuracy of a special-day load forecasting.

  • PDF