• 제목/요약/키워드: Temperature Drop Efficiency

검색결과 145건 처리시간 0.028초

정전형여과집진방식에서 여과특성에 관한 연구 (A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter)

  • 천중국;박출재;최금찬
    • 한국대기환경학회지
    • /
    • 제11권4호
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

PDTF를 이용한 석탄가스화 특성 실험 (Pressurized Drop Tube Furnace Tests of Global Gasification Characteristics of Coal)

  • 신용승;최상민;안달홍
    • 에너지공학
    • /
    • 제8권4호
    • /
    • pp.560-566
    • /
    • 1999
  • 가압 조건하에서의 석탄가스화 특성을 규명하기위해 , 온도 압력 , 산소/석탄비, 수증기/석탄비 등을 변화시켜가며 로토탄(sub A)에 대하여 PDTF(Pressuized drop tube furnace)실험을 수행하였다. 실험결과, 상압 조건에서보다 가압조건에서의 가스화가 탄소전환율과 냉가스효율의 측면에서 더 유리한 것으로 측정되었다. 최대의 냉가스효율을 보이는 산소/석탄비의 증가가 냉가스효율의 증가를 가져왔다. 압력이 증가할수록 열분해에 의한 탄소전환의 비중은 감소하고 대신 기고반응에 의한 탄소전환의 비중이 증가하였다.

  • PDF

PDTF를 이용한 석탄가스화 특성 실험 (Pressurized drop tube furnace tests of global gasification characteristics of coal)

  • 신용승;최상민;안달홍
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 춘계 학술발표회 논문집
    • /
    • pp.23-31
    • /
    • 1999
  • 가압 조건하에서의 석탄가스화 특성을 규명하기 위해, 온도, 압력, 산소/석탄비, 수증기/석탄비 등을 변화시켜가며 로토탄(Sub A)에 대하여 PDTF(Pressurized drop tube furnace) 실험을 수행하였다. 실험결과, 상압 조건에서보다 가압조건에서의 가스화가 탄소 전환율과 냉가스효율의 측면에서 더 유리한 것으로 측정되었다. 최대의 냉가스효율을 보이는 산소/석탄비(무게기준)는 0.5∼0.7(g/g)로 측정되었고, 온도가 충분히 높은 경우에만 수증기/석탄비의 증가가 냉가스효율의 증가를 가져왔다. 압력이 증가할수록 열분해에 의한 탄소전환의 비중은 감소하고 대신 기고반응(heterogeneous reaction)에 의한 탄소전환의 비중이 증가하였다.

  • PDF

고온 작동 싸이클론 유체역학적 거동 전산 연구 (A numerical fluid dynamic study of a high temperature operating cyclone)

  • 신미수;김혜숙;장동순
    • 대한환경공학회지
    • /
    • 제31권11호
    • /
    • pp.1033-1040
    • /
    • 2009
  • 고효율 싸이클론의 설계는 압력강하의 최소화와 집진효율의 최대화를 이루는 것이 중요하다. 본 연구는 고온, 고압 조건하에서 신뢰성 있는 컴퓨터 프로그램을 개발하여 싸이클론의 집진효율에 영향을 주는 물리적 메카니즘을 연구하는 것이다. 수치 해석적 연구를 통한 고온, 고압 조건에서의 압력강하 계산은 실험데이터와 비교적 잘 일치하였다. 온도와 압력은 일반적으로 집진효율에 중요한 영향을 미치는데 보통 항력에서 가스의 밀도나 점도 등에 영향을 주어서로 상반되는 결과를 나타낸다. 그러므로 고온 운전에 따른 집진효율의 감소는 고압 조건으로 운전하는 것이 대안이 될 것으로 판단된다. 집진효율에 영향을 주는 인자에 대해 좀 더 세부적인 연구를 위하여 접선방향 속도나 보텍스 파인더의 직경 등과 같은 싸이클론의 설계변수나 운전변수에 따른 연구를 수행하였다. 예상한 바와 같이 접선방향의 속도가 집진효율에 가장 큰 영향을 주었다. 그리고 보텍스 파인더의 직경이 증가할수록 집진효율은 감소하였으며 보텍스 파인더의 길이는 집진효율에 큰 영향을 나타내지 않았다.

2009년 7월 22일 부분일식 발생 시 부산지역 기온과 오존농도의 변화 특성 (Characteristics on Variation of Temperature and Ozone Concentration during the Partial Solar Eclipse Event of 22 July 2009 at Busan)

  • 전병일;오인보
    • 한국환경과학회지
    • /
    • 제20권8호
    • /
    • pp.1049-1059
    • /
    • 2011
  • This paper examines the effects of the partial solar eclipse of 22 July 2009 across the Korean peninsular on surface temperature and ozone concentrations in over the Busan metropolitan region (BMR). The observed data in the BMR demonstrated that the solar eclipse phenomenon clearly affects the surface ozone concentration as well as the air temperature. The decrease in temperature ranging from 1.2 to $5.4^{\circ}C$ was observed at 11 meteorological sites during the eclipse as a consequence of the solar radiation decrease. A large temperature drop exceeding $4^{\circ}C$ was observed at most area (8 sites) of the BMR. Significant ozone drop (18~29 ppb) was also observed during the eclipse mainly due to the decreased efficiency of the photochemical ozone formation. The ozone concentration started to decrease at approximately 1 to 2 hours after the event and reached its minimum value for a half hour to 2 hours after maximum eclipse. The rate of ozone fall ranged between 0.18 and 0.49 ppb/min. The comparison between ozone measurements and the expected values derived from the fitted curve analysis showed that the maximum drop in ozone concentrations occurred at noon or 1 PM and was pronounced at industrial areas.

통신 함체 냉각용 알루미늄과 플라스틱 열교환 소자의 성능 비교 (Aluminum and Plastic Heat Exchange Element : A Performance Comparison for Cooling of Telecommunication Cabinet)

  • 김내현
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.279-288
    • /
    • 2017
  • Heat generation rate in a telecommunication cabinet increases due to the continued usage of mobile devices. Insufficient removal of heat intensifies the cabinet temperature, resulting in the malfunction of electronic devices. In this study, we assessed both aluminum and plastic heat exchangers used for cooling of the telecommunication cabinet, and compared the results against theoretical predictions. The aluminum heat exchanger was composed of counter flow parallel channels of 4.5 mm pitch, and the plastic heat exchangers were composed of cross flow triangular channels of 2.0 mm pitch. Samples were made by installing two plastic heat exchangers in both series and parallel. Results showed that the heat transfer rate was highest for the series cross flow heat exchanger, and was least for the aluminum heat exchanger. The temperature efficiency of the series cross flow heat exchanger was 59% greater than that of the aluminum heat exchanger, and was 4.3% greater than that of the parallel cross flow heat exchanger. In contrast, the pressure drop of the parallel cross flow heat exchanger was significantly lower than other samples. The heat exchange efficiency was also the largest for the parallel cross flow heat exchanger. The theoretical analysis predicted the temperature efficiency to be within 3.3%, and the pressure drop within 6.1%.

입자상물질과 Ash양이 디젤매연여과장치 내의 배압 및 유동균일도에 미치는 영향 (Effect of Particulate Matter and Ash Amount on Pressure Drop and Flow Uniformity of Diesel Particulate Filter Reduction System)

  • 김윤지;한단비;서태원;오광철;백영순
    • 청정기술
    • /
    • 제26권1호
    • /
    • pp.22-29
    • /
    • 2020
  • 최근 미세먼지 증가로 인하여 디젤엔진의 배출 규제가 강화됨에 따라 디젤 매연여과장치에 관심이 급증하게 되었으며, 특히 디젤 배기가스 후처리 장치의 고효율화에 대한 기술개발이 더욱 요구되고 있다. 이에 대한 일환으로서 디젤매연여과장치(diesel particulate filter, DPF) 내 배기가스의 유동 균일도를 향상시키고 배압을 낮추어서 배기가스처리 효율을 높이는 연구가 많이 되고 있다. 본 연구에서는 ANSYS Fluent를 이용하여 직경 12"의 DPF와 디젤산화촉매(diesel oxidation catalyst, DOC)를 장착한 디젤 매연여과장치에서의 배기가스의 유속과 온도, DPF IO ratio, Ash와 PM양에 따른 배압에 미치는 영향을 시뮬레이션 하여 배압을 낮추는 최적화 연구를 하였다. 결과로서 배기가스의 온도와 유속이 낮을수록 배압이 낮아졌으며, PM양이 Ash양보다 배압에 더 큰 영향을 주는 것으로 나타냈다. 또한 비대칭 DPF가 대칭 DPF에 비해 배압이 더 낮게 나타냈으나, 유동 균일도의 경우는 다양한 변수에 관계없이 일정하게 나타냈다. european stationary cycle (ESC), european transient cycle (ETC) 조건에서 PM의 정화효율은 비대칭, 대칭 DPF 관계없이 유사하나, particle number (PN)의 정화효율에서는 비대칭 DPF가 대칭 DPF에 비해 높게 나타냈다.

고온 고압 집진을 위한 역세정 유동장의 특성에 관한 연구 (A Study on the Reverse Cleaning Flow Characteristics for High Temperature and High Pressure Filtration)

  • 김장우;정진도;김은권
    • 한국대기환경학회지
    • /
    • 제19권1호
    • /
    • pp.25-31
    • /
    • 2003
  • Ceramic filter has been demonstrated as an attractive system to improve the thermal efficiency and to reduce the effluent pollutants. Removal of particulates from the hot gas stream is very important in air pollution control. In particular, the elimination of the particulate matters discharged from a gas turbine at high temperature can prevent the corrosion inside the IGCC. In this study, a Lab. scale test and numerical simulation were carried out to comprehend the relationship between pulse jet pressure and recovery of pressure drop and to characterize the reverse cleaning flow through a ceramic fil-ter element under high temperature and high pressure. When the pulse-jet pressures were 2, 3 and 4 kg/$ extrm{cm}^2$, the cleaning effect increase of about 10~30% by recovery of pressure drop caused by pulse pressure. Cleaning effect at 45$0^{\circ}C$ was greater than that at 55$0^{\circ}C$ or 650$^{\circ}$ for the same pulse pressure. According to the result of the present simulation, high pressure has been formed in terminal and central regions in our models and temperature distribution caused by pulse air is to be uniform comparatively on inner surface of filter.

반경방향 분사방식 프리스월 시스템의 프리스월 노즐과 리시버 홀의 상대적 위치에 따른 시스템 성능변화 (System Performance Variation for Relative Location of Pre-swirl Nozzles and Receiver Holes in Radial On-Board Injection Type Pre-swirl System)

  • 이종건;이현규;조건환;조진수
    • 한국항공우주학회지
    • /
    • 제48권1호
    • /
    • pp.43-53
    • /
    • 2020
  • 프리스월 노즐과 리시버 홀의 상대적 위치가 반경방향 분사방식 프리스월 시스템의 성능에 미치는 영향을 분석하였다. 본 연구에서는 5개의 프리스월 노즐 위치와 4개의 리시버 홀 위치 조합을 통해 20개의 설계점에 대한 분석을 진행하여 유량계수와 온도 강하 효율 변화 경향성을 연구하였다. 시스템 유량계수는 프리스월 노즐의 압력비와 비슷한 경향을 보였다. 캐비티 내부의 유동이 벽면의 영향을 크게 받을수록 시스템 성능 변화가 발생하였으며 회전면보다 정지면의 영향력이 더 큰 것을 확인하였다. 형상변수 변화에 따라 기준 설계점 대비 유량계수는 -1.39%~1.25%, 온도강하효율은 -5.41%~2.94% 변화하였다.

Drop Tube Furnace를 이용한 순산소연소 배가스 로내탈황에 관한 연구 (Study on the In-Furnace Desulfurization for Oxy-Fuel Combustion Flue Gases Using Drop Tube Furnace)

  • 안영모;조항대;최원길;박영성;길상인;이형근
    • Korean Chemical Engineering Research
    • /
    • 제47권4호
    • /
    • pp.512-517
    • /
    • 2009
  • 순산소 연소에서 $SO_2$ 농도는 배가스의 재순환으로 인해 기존의 공기연소에 비해 3배 이상 높게 나타나고, $CO_2$ 농도와 $SO_2$ 농도가 높기 때문에 탈황현상이 기존의 공기 연소와는 다르게 나타난다. 본 연구에서는 순산소 연소조건에서 로내탈황 특성을 알아보기 위해 Drop Tube Furnace(DTF)를 이용하여, 반응온도, 유입 $SO_2$ 농도 그리고 Ca/S 비 등의 운전변수에 따른 $SO_2$ 제거효율을 측정하였으며 수분의 영향에 대해서도 알아보았다. 반응온도, 유입 $SO_2$ 농도 그리고 Ca/S 비가 증가함에 따라 $SO_2$ 제거효율은 증가하였고 유입가스 내 수분이 존재할 경우 $SO_2$ 제거효율은 약 4~6% 증가하는 것으로 나타났다.