• 제목/요약/키워드: Temperature Difference Energy

검색결과 1,097건 처리시간 0.027초

SWPV 태양 열-전기 복합생산 모듈 성능평가 연구 (Performance Evaluation Study of Solarwall-Photovoltaic Module to Generate Solar Electric Power)

  • 아메드 나비드;강은철;이의준
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.397-402
    • /
    • 2005
  • Photovoltaic (PV) module can generate electricity using sunlight without causing any environmental degradation. Due to higher fossil fuel prices and environmental awareness, PV applications are becoming more popular as clean source of electricity generation. PV output is sensitive to the operating temperature and can be drastically affected in Building Integrated PV (BIPV) systems. PV Solarwall (SWPV) combination and PV systems have been evaluated in this study for improvement in electrical output and system costs. PV modules under forced ventilation. A 75W polycrystalline silicon PV module was fixed on SW in front of the ventilation fan as it was indicated to be the coolest position on the SW in phoenix simulations. The effectiveness of cooling by means of the forced ventilating air stream has been studied experimentally. The results indicate that there appears to be significant difference in temperature as well as electricity output comparing the SWPV and BIPV options. Electrical output power recovered is about $4\%$ during the typical day of the month of February. RETScreen(R) analysis of a 3kW PV system hypothetically located at Taegu has shown that with typical temperature reduction of $15^{{\circ}C$, it is possible to reduce the simple payback periods by one year. The work described in this paper may be viewed as an appraisal of a SWPV system based on its improved electrical and financial performances due to its ability to operate at relatively lower temperatures.

  • PDF

석탄과 제지슬러지 혼소에 따른 연소특성에 관한 연구 (Characterization on Co-Combustion of Coal and Paper Mill Sludge)

  • 이갑두;류태욱;박상원
    • 한국환경과학회지
    • /
    • 제22권3호
    • /
    • pp.331-339
    • /
    • 2013
  • Efforts were made to determine the activation energy and the reaction order by adopting Kissinger and Flynn-Wall-Ozawa analysis methods. All the data were acquired from TGA thermograms for the mixed fuels with different temperature heating rates. It could be known that both the coal and the mixed fuels decomposed thermally at temperature ranges of $300{\sim}700^{\circ}C$. The temperature at the maximum reaction rate, Tp, could be determined by DTG method, which could be obtained by differentiation of TGA thermogram. Kissinger analysis showed the linear relationship with experimental data, showing the activation energy of $319.64{\pm}4$ kJ/mol. From Flynn-Wall-Ozawa analysis, it was shown that the activation energies and the reaction orders did not undergo any significant changes with both the conversions and the heating rates. It was considered from this facts that the combustion mechanism of the mixed fuels could not be affected by the extent of conversion and heating rate. In the present study, the activation energies showed different values according to the different analysis methods. The difference might be originated from the inconsistency of the mathematical data treatment method. In other words, while the activation energies obtained from the Kissinger method indicated the average values for overall reaction, that from Flynn-Wall-Ozawa method showed the average values for the each conversion around Tp.

고온 발전용 산화물 열전모듈의 설계 (The Design of Oxide Module for High Temperature Thermoelectric Power Generation)

  • 박종원;윤선호;차정의;최승철
    • 마이크로전자및패키징학회지
    • /
    • 제15권4호
    • /
    • pp.93-100
    • /
    • 2008
  • 고온 발전용 열전모듈을 p-type으로는 $Ca_{2.7}Bi_{0.3}Co_4O_9$, n-type으로는 $Ca_{0.96}Bi_{0.04}Mn_{0.96}Nb_{0.04}O_3$을 선택하고 알루미나 기판 위에 1쌍과 2쌍을 제조하였다. 산화물 열전 모듈의 최적화 설계를 위해 먼저 1쌍의 열전모듈의 실험 결과로부터 전극의 접촉저항을 산출하여 2쌍 모듈에 적용함으로써 저항과 출력 특성을 예측하였다. 예측된 2쌍 모듈의 계산 값과 제조된 2쌍 모듈의 실측 값을 비교함으로써 모듈 설계를 위한 접근방법을 검토하였다. 2쌍 모듈의 계산된 저항과 측정된 저항은 각각 $T_h$=833 K에서 0.954 $\Omega$과 1.105 $\Omega$으로 약 0.15 $\Omega$ 정도의 차이로 근접한 결과를 얻었으며, 제시된 방법으로 고온산화물 열전 모듈 제작에 유효하다고 판단된다.

  • PDF

고에너지밀도 캐패시터를 위해 PET 기판에 증착한 TiO2 박막의 특성 (Properties of TiO2 Thin Films Deposited on PET Substrate for High Energy Density Capacitor)

  • 박상식
    • 한국재료학회지
    • /
    • 제22권8호
    • /
    • pp.409-415
    • /
    • 2012
  • $TiO_2$ thin films for high energy density capacitors were prepared by r.f. magnetron sputtering at room temperature. Flexible PET (Polyethylene terephtalate) substrate was used to maintain the structure of the commercial film capacitors. The effects of deposition pressure on the crystallization and electrical properties of $TiO_2$ films were investigated. The crystal structure of $TiO_2$ films deposited on PET substrate at room temperature was unrelated to deposition pressure and showed an amorphous structure unlike that of films on Si substrate. The grain size and surface roughness of films decreased with increasing deposition pressure due to the difference of mean free path. X-ray photoelectron spectroscopy (XPS) analysis revealed the formation of chemically stable $TiO_2$ films. The dielectric constant of $TiO_2$ films was significantly changed with deposition pressure. $TiO_2$ films deposited at low pressure showed high dissipation factor due to the surface microstructure. The dielectric constant and dissipation factor of films deposited at 70 mTorr were found to be 100~120 and 0.83 at 1 kHz, respectively. The temperature dependence of the capacitance of $TiO_2$ films showed the properties of class I ceramic capacitors. $TiO_2$ films deposited at 10~30 mTorr showed dielectric breakdown at applied voltage of 7 V. However, the films of 500~300 nm thickness deposited at 50 and 70 mTorr showed a leakage current of ${\sim}10^{-8}{\sim}10^{-9}$ A at 100 V.

PTC와 평판형 태양열집열기의 성능평가 비교 연구 (The Comparative Study on Performance of PTC and Flat-plate Solar Collector)

  • 김인환;허남수;김만석;이정언
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.28-33
    • /
    • 2010
  • Solar collectors to be applied are mainly flat-plate or vacuum tube collector which is used for hot water supply of house because of low heat value and low temperature. There are a necessity to expand applicable scope of solar collector into the industrial process heat source and air conditioner for coping with renewable energy policy of government and industrial trend. This study is to analysis the performance of PTC solar collector of concentrating type and flat-plate of non-concentrating. For this, temperature difference and heating value as insolation of air outside is measured from these two collectors mounted on 2-axial solar tracking system. It is investigated that temperature profile obtained from PTC solar collector is uniform and collecting heat per unit area is 6.8kcal/$m^2$ min which is about 3 times with compare to flat-plate collector of 2kcal/$m^2$min. Also the amount of heat to be produced from PTC solar collector is 3 Mcal/$m^2$ which is about 2 times with compare to flat-plate collector of 1.5Mcal/$m^2$ as a result of operating these two collectors during one month. Therefore, it is obtained that heat collecting performance of PTC solar collector is superior to flat-plate.

무변압기형 태양광 인버터의 출력 전류 DC offset 제거 방법 (Output Current DC offset Removal Method for Trans-less PV Inverter)

  • 홍기남;최익;최주엽;이상철;이동하
    • 한국태양에너지학회 논문집
    • /
    • 제32권spc3호
    • /
    • pp.255-261
    • /
    • 2012
  • Since PV PCS uses output current sensor for ac output current control, the sensor's sensing value includes unnecessary offset inevitably. If PV inverter is controlled by the included offset value, it's output current will generate DC offset. The DC offset of output current for trans-less PV inverter is fatal to grid, which results in saturating grid side transformer. Usually DSP controller of PV inverter reads several times sensing value during initial operation and, finally, it's average value is used for offset calibration. However, if temperature changes, the offset changes, too. And also, the switch device is not ideal, both each switching element of the voltage drop difference and on & off time delay difference generate DC offset. Thus, to compensate for deadtime and the switch voltage drop, feedback control by output current DC offset should be provided to compensate additional distortion of the output current. The validity of the proposed method is confirmed through PSIM simulation.

Influence of nuclear data library on neutronics benchmark of China experimental fast reactor start-up tests

  • Guo, Hui;Jin, Xin;Huo, Xingkai;Gu, Hanyang;Wu, Haicheng
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3888-3896
    • /
    • 2022
  • Nuclear data is the basis of reactor physics analysis. This paper aim at studying the influence of major evaluated nuclear data libraries, CENDL-3.2, ENDF/B-VIII.0, JEFF-3.3, and JENDL-4.0u, on the neutronics modelling of CEFR start-up tests. Results show these four libraries have a good performance and consistency in the modelling CEFR start-up tests. The JEFF-3.3 results exhibit only an 8 pcm keff difference with the measurement. The difference in criticality is decomposed by nuclide, which shows the large overestimation of CENDL-3.2 is mainly from the cross-section of 52Cr. Except for few cases, the calculation results are within 1σ of measurement uncertainty in control rod worth, sodium void reactivity, temperature reactivity, and subassembly swap reactivity. In the evaluation of axial and radial reaction distribution, there are about 65% of relative errors that are less than 5% and 82% of relative errors that are less than 10%.

Entropy Generation Minimization in MHD Boundary Layer Flow over a Slendering Stretching Sheet in the Presence of Frictional and Joule Heating

  • Afridi, Muhammad Idrees;Qasim, Muhammad;Khan, Ilyas
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1303-1309
    • /
    • 2018
  • In the present paper, we study the entropy analysis of boundary layer flow over a slender stretching sheet under the action of a non uniform magnetic field that is acting perpendicular to the flow direction. The effects of viscous dissipation and Joule heating are included in the energy equation. Using similarity transformation technique the momentum and thermal boundary layer equations to a system of nonlinear differential equations. Numerical solutions are obtained using the shooting and fourth-order Runge-Kutta method. The expressions for the entropy generation number and Bejan number are also obtained using a suggested similarity transformation. The main objective of this article is to investigate the effects of different governing parameters such as the magnetic parameter ($M^2$), Prandtl number (Pr), Eckert number (Ec), velocity index parameter (m), wall thickness parameter (${\alpha}$), temperature difference parameter (${\Omega}$), entropy generation number (Ns) and Bejan number (Be). All these effects are portrayed graphically and discussed in detail. The analysis reveals that entropy generation reduces with decreasing wall thickness parameter and increasing temperature difference between the stretching sheet and the fluid outside the boundary layer. The viscous and magnetic irreversibilities are dominant in the vicinity of the stretching surface.

Effects of inert gas (Ne) on thermal convection of mercurous chloride system of $Hg_2Cl_2$ and Ne during physical vapor transport

  • Choi, Jeong-Gil;Lee, Kyong-Hwan;Kim, Geug-Tae
    • 한국결정성장학회지
    • /
    • 제18권6호
    • /
    • pp.225-231
    • /
    • 2008
  • For an aspect ratio (transport length-to-width) of 5, Pr=1.13, Le=1.91, Pe=4.3, Cv=1.01, $P_B=20\;Torr$, the effects of addition of inert gas Ne on thermally buoyancy-driven convection ($Gr=2.44{\times}10^3$) are numerically investigated for further understanding and insight into essence of transport phenomena in two dimensional horizontal enclosures. For $10K{\leq}{\Delta}T{\leq}50\;K$, the crystal growth rate increases from 10 K up to 20 K, and then is slowly decreased until ${\Delat}T=50\;K$, which is likely to be due to the effects of thermo-physical properties stronger than the temperature gradient corresponding to driving force for thermal convection. The dimensional maximum velocity gratitude reflecting the intensity of thermal convection is directly and linearly proportional to the temperature difference between the source and crystal regions. The rate is first order-exponentially decreased for $2{\leq}Ar{\leq}5$. This is related to the finding that the effects of side walls tend to stabilize convection in the growth reactor. In addition, the rate is first order exponentially decayed for $10{\leq}P_B{\leq}200\;Torr$.

산업용 건축물 내 자동제어반의 냉각효율 향상에 관한 연구 (A Study on the Enhancement of Cooling Efficiency for the Cabinet of Automatic Controller in the Interior of Industrial Building)

  • 김순호;박현정
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.79-87
    • /
    • 2013
  • The improvement of cooling efficiency for the cabinet of automatic controller is the most efficient method of it's application. Therefore, this study has been analyzed and investigated the improvement of cooling efficiency and reduction of energy for the cabinet of automatic controller, respectively. So this study was conducted to enhancement of cooling efficiency for the cabinet of automatic controller by making a structure which produces difference of air pressures in the entrance tube of external air. And the structure has capacity of the pyrogen source (PTC elements) to make temperature range from $145^{\circ}C$ to $155^{\circ}C$. Consequently, temperatures of the upper, the lower in the interior of the cabinet of automatic controller and the exhaust part were revealed $28.57^{\circ}C$, $23.38^{\circ}C$and $36.14^{\circ}C$(average temperature of the exhaust part in case of existing method : $45^{\circ}C$) in target test of this study, respectively. It was found that the cabinet of the automatic controller has better cooling ability than the cabinet of automatic controller by using an existing method.