수평형 지열 히트펌프 난방 성능 분석을 위한 실험적 연구 (Experimental Study for Horizontal Geothermal Heat Pump Heating Performance Analysis)

  • 임병찬;조성우
    • 한국지열·수열에너지학회논문집
    • /
    • 제12권2호
    • /
    • pp.7-12
    • /
    • 2016
  • This study have an objective to suggest basic data and measured result of heating performance on water-water type horizontal geothermal heat pump which is based on heating and cooling load calculation result of small residential house. The average temperature during measured periods is $9.4^{\circ}C$ on primary EWT and is $7.6^{\circ}C$ on primary LWT. The temperature difference shows $1.8^{\circ}C$ as average temperature. Because the average outdoor temperature of peak is lager than on December and than on January, the temperature difference between EWT and LWT is bigger that on January than that on December. The system COP is 3.62.

바닥복사 난방시스템의 실내 열환경 특성에 대한 실험적 연구 (Experimental Study on the Indoor Thermal Characteristics for Floor Radiant Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권3호
    • /
    • pp.1-12
    • /
    • 2021
  • In this study, the effects of various operational conditions for floor radiant heating system were researched by experiments. Hot water supply set temperature, indoor air set temperature and supply water flowrate were considered as operational conditions. The control method for this system is On-Off control of automatic thermostatic valve. The purpose of this study is to evaluate indoor thermal control characteristics and energy performance, respectively. As a result, if lower supply water temperature is applied, the supply and return temperature difference is reduced and energy consumption of heat supply is also reduced.

A practical power law creep modeling of alloy 690 SG tube materials

  • Lee, Bong-Sang;Kim, Jong-Min;Kwon, June-Yeop;Choi, Kwon-Jae;Kim, Min-Chul
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.2953-2959
    • /
    • 2021
  • A new practical modeling of the Norton's power law creep is proposed and implemented to analyze the high temperature behaviors of Alloy 690 SG tube material. In the model, both the stress exponent n and the rate constant B are simply treated as the temperature dependent parameters. Based on the two-step optimization procedure, the temperature function of the rate constant B(T) was determined for the data set of each B value after fixing the stress exponent n value by using the prior optimized function at each temperature. This procedure could significantly reduce the numerical errors when using the power law creep equations. Based on the better description of the steady-state creep rates, the experimental rupture times could also be well predicted by using the Monkman-Grant relationship. Furthermore, the difference in tensile strengths at high temperatures could be very well estimated by assuming the imaginary creep stress related to the given strain rate after correcting the temperature effects on the elastic modulus.

공랭식 변유량 냉매 냉동기를 적용한 수조 온도의 정밀 제어 (Precision Control of Water Bath Temperature using Air Cooled Variable Refrigerant Flow Chiller)

  • 정광주;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.27-34
    • /
    • 2018
  • This study compared constant water bath performances of conventional water-cooled refrigerator and electric heater with an air-cooled VRF chiller and electric heater equipped with optimal control algorithm. In heating mode, the air cooled VRF chiller and electric heater combination reduced the set temperature arrival time by an average of 42 minutes, and energy was also reduced by 18%. In cooling mode, the two systems took 70 minutes to reach the set temperature and showed no difference. Energy was reduced by 33.5% with the new system. For constant temperature maintaining experiment, after reaching the set temperature of $15^{\circ}C$, $20^{\circ}C$ and $22^{\circ}C$, temperature deviations were all in the range of $-0.2^{\circ}C$ to $+0.1^{\circ}C$. Energy was reduced by an average of 84.9%. Through this study, possibility of precise temperature control by an air cooled VRF chiller system was confirmed.

각종 Nozzle을 통하여 저장조내로 유입되는 BUOYANT JETS의 유동해석 (Flow analysis of Buoyant Jets into Storage Tank through Variable Nozzles)

  • 박이동;조운
    • 태양에너지
    • /
    • 제9권2호
    • /
    • pp.42-50
    • /
    • 1989
  • The Buoyant Jets were analysed experimentally changing flow rate (0.0291/s, 0.0371/s, 0.0451/s), ratio of nozzle tip area to throat area (aspect ratio ${\beta}$=0.4, 1.0, 1.9), and also the temperature difference (${\Delta}T=Ti-T{\infty}$) between the temperature of the inflow water into the storage tank ($1m{\times}1m{\times}3m$) and the mean temperature of the water in the storage tank were changed as $25^{\circ}C,\;35^{\circ}C$ and $45^{\circ}C$. The more aspect ratio decreased, the more the trajectories of Buoyant Jets center-line were decreased and not the more the trajectories of Buoyant Jets centerline were influenced by the increment of the difference of the temperature. The more aspect ratio decreased, the more the half widths and dilution ratio of Buoyant Jets were increased and not the more the half widths and dilution ratio of Buoyant Jets were influenced by the increment of the difference of the temperature. Fr number is the factor that can predict the flow pattern over the whole flow field. And yet for the consideration the near field of Buoyant Jets flow pattern is dominated by magnitude of momentum and buoyancy force.

  • PDF

상변화 물질의 용융과정에 있어서 좌표변환을 이용한 온도분포의 해석적 연구 (The finite difference analysis on temperature distribution by coordinate transformation during melting process of phase-change Material)

  • 김준근;임장순
    • 태양에너지
    • /
    • 제5권2호
    • /
    • pp.77-83
    • /
    • 1985
  • An analysis is performed to investigate the influence of the buoyancy force and the thickness variation of melting layer in the containment that is filled with phase-change Material surrounding a cylindrical heating tube during melting process. The phase-change material is assumed to be initially solid at its phase-change temperature and the remaining solid at any given time is still at the phase-change temperature and neglecting the effect of heat transfer occuring within the solid. At the start of melting process, the thickness of melting layer is assumed to be a stefan-problem and after the starting process, the change of temperature and velocity is calculated using a two dimensional finite difference method. The governing equations for velocity and temperature are solved by a finite difference method which used SIMPLE (Semi Implicit Method Pressure linked Equations) algorithm. Results are presented for a wide range of Granshof number and in accordance with the time increment and it is founded that two dimensional fluid flow occurred by natural convection decreases the velocity of melting process at the bottom of container. The larger the radius of heating tube, the higher heat transfer is occurred in the melting layer.

  • PDF

착의량과 실내설정온도 관계에 따른 난방에너지 및 온실가스저감량 평가 연구 (A Study on the Estimation of Heating Energy and CO2 Reduction depending on a Indoor Set Temperature and Clo value)

  • 이철성;윤종호
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.49-54
    • /
    • 2010
  • Most energy using in building part is mainly consumed for heating and cooling to meet occupancy's comfort temperature. Generally, heating energy consumption show high value than cooling energy in Korea because of high temperature difference in winter season as compared with summer in apartment building. The efforts to develope mechanical performance have been studied to reduce energy consumption in building energy field until now. However, the energy consumption in building is impacted by not only system performance but also PMV particularly at temperature and Clo value. This means that energy consumption can be changed by occupancy's comfort setting temperature in apartment building. This study investigated the passibility of overheating in apartment building by occupant' slow Clo and its setting temperature from preceding research and then the heating energy consumption by setting temperature was calculated with ESP-r. The effects of heating energy and $CO_2$ reduction are also evaluated quantitatively with Clo value. The results showed that keeping ISO-7730 standards can reduce heating energy up to 21% in compared with option 2; also, wearing underclothes with ISO-7730 standard can considerably reduce heating energy consumption up to 50%. As compared with option 2, the reduction of $CO_2$ emission for option 3 showed 0.63TCO2 of kerosene, 0.49TCO2 of LNG and 1.09TCO2 of electricity. The option 4 can be reduced by 1.48TCO2 of kerosene, 1.16TCO2 of LNG and 2.57TCO2 of electricity respectively.

파일럿 규모 막 증발 공정 적용을 위한 직접 접촉식 모듈의 투과유속 및 열에너지 이동에 관한 연구 (A Study on the Flux and Heat Transfer of Direct Contact Type Module Applied for a Pilot Scale Membrane Distillation Process)

  • 김승환;김세운;이동우;조진우
    • 상하수도학회지
    • /
    • 제31권3호
    • /
    • pp.229-236
    • /
    • 2017
  • In this study, a direct contact membrane module was manufactured to be used in a pilot scale membrane distillation process to treat $3m^3/day$ of the digestate produced from anaerobic digestion of livestock manure. In order to investigate the performance of the membrane module, permeate flux was measured with and without spacer inside the module under various condition of temperature difference and cross flow velocity (CFV) through the membrane surfaces. Flux recovery rate after chemical cleaning was also investigated by applying three different cleaning methods. Additionally, thermal energy consumption was theoretically simulated based on actual pilot plant operation conditions. As results, we observed flux of the module with spacer was almost similar to the theoretically predicted value because the installation of spacer reduced the channeling effect inside the module. Under the same operating condition, the permeate flux also increased with increasing temperature difference and CFV. As a result of chemical in-line cleaning using NaOCl and citric acid for the fouled membranes, the recovery rate was 83.7% compared to the initial flux when NaOCl was used alone, and 87% recovery rate was observed when only citric acid was used. However, in the case of using only citric acid, the permeate flux was decreased at a rapid rate. It seemed that a cleaning by NaOCl was more effective to recover the flux of membrane contaminated by the organic matter as compared to a cleaning by citric acid. The total heat energy consumption increased with increasing CFV and temperature difference across the membrane. Thus, further studies should be intensively conducted to obtain a high permeate flux while keeping the energy consumption to a minimum for a practical application of membrane distillation process to treat wastewater.

이동식 수소 충전 장비용 수소 밸브의 유체 온도 변화에 따른 유동 특성의 수치해석적 연구 (A Numerical Analysis Study of Hydrogen Valve to Flow Characteristics by Fluid Temperature Variation for Mobile Charging Equipment)

  • 권준영;오승준;최정주;김용기
    • 한국수소및신에너지학회논문집
    • /
    • 제33권6호
    • /
    • pp.769-775
    • /
    • 2022
  • Global efforts to reduce carbon emissions have focused attention on the development of hydrogen energy and the development of various hydrogen mobility requires mobile hydrogen charging stations. In this study, the flow characteristics of the flow control hydrogen valve for mobile hydrogen charging equipment were studied according to the temperature change of hydrogen gas. The inlet pressure was 100 MPa, the outlet pressure to 70 MPa, and temperature condition was set -40℃ to 85℃. As a result, the difference in the valve flow coefficient, which determines the capacity of the valve, showed a difference within 5% depending on the temperature.

Experimental Results of Turbulent Thermal Mixing Phenomena Using Sodium Parallel Jets

  • Lee, Y.B.;Park, S.K.;J.S. Hwang;Kim, Y.K.;H.Y. Nam
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(2)
    • /
    • pp.199-204
    • /
    • 1996
  • In the present the mean temperature and the temperature fluctuation of non-isothermal parallel liquid sodium jets were measured and analyzed changing the temperature difference and mean velocity of the hot and cold sodium. The sampling frequency and sampling time were 420Hz and three seconds, respectively. The wave-form characteristics were discussed in regard to the peak-to-peak amplitudes and the periods provided by a wave analysis. And also the correlations of the temperature fluctuation in rms value and the peak amplitude are derived. The overall mean accuracy ratios of the correlations are 1.07 and 1.08 with a standard deviation of 0.17 and 0.15, respectively.

  • PDF