• Title/Summary/Keyword: Temperature Difference

Search Result 6,996, Processing Time 0.039 seconds

The Characteristics of Air Temperature Distribution by Land-use Type -A case study of around Automatic Weather Station in Seoul- (토지이용 유형에 따른 기온 특성 -서울시 자동기상관측지점 주변을 사례로-)

  • Kwon, Young-Ah;Lee, Hyoun-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.4
    • /
    • pp.281-290
    • /
    • 2003
  • The influence of land-use type on surrounding temperature was studied the relationships between land-use types and the air condition analyzing AWS (Automatic Weather Station) data of Seoul from KMA (Korea Meteorological Administration). The distribution of air temperature by land-use type has been influenced by the different heating and cooling rates. The difference of heating rates depending on the land-use type was largest at 2~3hours after sunrise and the difference of cooling rates was largest from 2hours before sunset to 2hours after sunset with its maximum at sunset. The difference of cooling rates is greatest in a clear and calm weather situation and the large difference in cooling rates between the green areas and built-up area is up to $1.5^{\circ}C/h$. By season, the difference of cooling rates is largest in fall and in turn spring, winter and summer. In a cloudy or rainy day, the difference in heating and cooling rates on land-use type is not distinct but the tendency is similar to a clear day. In all seasons, the rate of difference occurrence of the daily range of temperature between the green areas and built-up area was large, especially fall. In a fall with a clear and calm day, the magnitude of the daily range of temperature between the green areas and built-up area was largest.

Analysis on Po1y(lactic acid) Melt Spinning Dynamics (Poly(lactic acid) 용융방사공정의 동역학 해석)

  • Oh, Tae-Hwan;Kim, Seong-Cheol
    • Clean Technology
    • /
    • v.15 no.4
    • /
    • pp.245-252
    • /
    • 2009
  • Profiles development of melt spinning process of poly(lactic acid) (PLA) was simulated via a numerical method and the radial temperature distribution was calculated using finite difference method. The spinning speed ranged from 1 km/min to 5 km/min was analyzed and the effect of spinning conditions on the radial temperature distribution was investigated. At low spinning speed, the difference between PLA and poly(ethylene terephthalate) (PET) was relatively small. As the spinning speed increased, the difference in velocity profile became prominent. PLA showed a slower spinning speed than PET and solidified more slowly. The temperature difference between the core and surface of the PLA filament reached 4.6 K, which was less than that of PET filament with a difference of 10.4 K. The radial temperature difference increased with increasing the cooling-air velocity and the spinning temperature.

A Study on the Comfort and Skin Temperature on the Clothing Environment in the Taegu City during Years -Concentrated on indoor uniforms- (섬유·패션 산업 DB 구축을 위한 대구지역의 연간 피복환경내의 피부온과 쾌적성 -실내 제복을 중심으로-)

  • Ryo, Duck-Hwan;Lee, Uk-Ja;Kim, Seong-Jin;Song, Min-Kyo;Cho, Ji-Hyun;Jung, Meung-Sun
    • Fashion & Textile Research Journal
    • /
    • v.1 no.4
    • /
    • pp.376-386
    • /
    • 1999
  • The purpose of this study was to determine the physiological responses and the Subjective sensations of the human subjects when 10 human subjects(5 males and 5 females) were tested with selected ensembles, including the uniforms of students, industrial and bank workers. For the study, garment material and design were selected, which was mostly used in Taegu area by the survey. Thermal manikin and the human subject tests were performed. The results were as follows: 1. There was no significant difference among skin temperature of head by season and among that of breast and back by all variables, however, there was a significant difference among that of belly by gender and that of thigh and shank by season. In addition, there was no significant difference among rectal temperature by gender and season, but there was a significant difference by uniform. 2. Mean skin temperature of male subjects was significantly higher than that of female subjects. Specially in lower environmental condition, the difference got larger. 3. There was a significant difference among purse rate of subjects by uniform, but there was no significant difference among those by gender and season. There were no significant difference among maximum and minimum blood pressure by gender, uniform, and season. 4. There was a significant difference in temperature of chest among gender and uniform, and there was no significant difference in temperature of back by season. In addition, There was a significant difference in humidity of back by uniform and season but there were no significant difference in that by gender. 5. There was a significant difference in humidity sensation by gender, comfort sensation by uniform and season, but there was no significant difference thermal sensation by uniform and season. 6. For the result of regression analysis, we got the regression equations as follows: Clo=1.810 Thickness+0.525, Clo=0.475 weight+0.863.

  • PDF

Utilization of Energy in the Sea Water of the Southeastern Yellow Sea (한국남서해의 열 에너지 이용)

  • 장선덕
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.113-116
    • /
    • 1978
  • To ascertain the feasibility of the energy utilization in the sea adjacent to Korea, the distribution of the vertical temperature difference and the seasonal variation in the southeastern Yellow Sea are studied in relation to the sea water circulation. In summer, a region of high vertical temperature difference of approximately 16$^{\circ}C$ was found at a distance of approximately 40 miles from the western coast of Korea. It is located at the west of 125${\circ}$ 30`E and at the north of 34${\circ}$N. The vertical temperature structure is sustained by the inflow of Yellow Sea Warm Current water, the warming of the surface water of the Yellow Sea and the periodical renewal of the Yellow Sea Cold Water. It may be stated that power can be obtained from the sea water by making the use of the temperature difference. The vertical temperature difference was around 14$^{\circ}C$ in the western and southern waters of Jejudo Island. The vertical temperature difference decreases in autumn, and disappears due chiefly to the vigorous convective vertical mixing in winter when the northwest monsoon prevails. The power can be obtained from sea throughout the year, if power generation by the temperature difference is combined with that by wind and wave, and systemized in such a way that the former is employed in the hot season of summer, while the latter in winter and spring.

  • PDF

Geometric Effects on Pressure Distribution in Mechanical Face Seals (기계평면시일의 기하학적 형태가 압력분포에 미치는 영향에 관한 연구)

  • 김청균;이일권
    • Tribology and Lubricants
    • /
    • v.5 no.2
    • /
    • pp.48-54
    • /
    • 1989
  • The effects of angular misalignment, coning and the temperature difference between the primary seal ring and the seal seat on the pressure distribution in mechanical face seals are analyzed. The modified Reynolds equation for the temperature dependent viscosity was solved by a finite difference approximation and Gauss-Seidel method. It is shown that the amplitude of pressure is significantly affected by the misalignment of the seals and a large temperature difference between the rotor and the stator.

DESIGN OF A LOW TEMPERATURE DIFFERENCE STIRLING ENGINE (저온도차 모형 스털링 엔진의 최대출력 설계조건)

  • Jung, P.S.;Won, M.Y.;Kim, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.420-423
    • /
    • 2003
  • A low temperature difference model Stirling engine is a small Stirling engine running with several degree of temperature difference without power output. In this study, the design parameters to give maximum power are discussed. As results, the phase angle is about 100 degree, and compression ratio is 1.5% of the ratio of heat source temperatures at maximum power condition.

  • PDF

Assessment of Temperature Reduction and Evapotranspiration of Green Roof Planted with Zoysia japonica (한국잔디식재 옥상녹화의 온도저감 및 증발산량 평가)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of Environmental Science International
    • /
    • v.22 no.11
    • /
    • pp.1443-1449
    • /
    • 2013
  • This was an experimental study to evaluate temperature reduction and evapotranspiration of extensive green roof. Three test cells with a dimension of $1.2(W){\times}1.2(D){\times}1.0(H)$ meters were built using 4-inch concrete blocks. Ten-centimeter concrete slab was installed on top of each cell. The first cell was control cell with no green roof installed. The second and third cells were covered with medium-leaf type Zoysiagrass (Zoysia japonica) above a layer of soil. Soil thickness on the second cell was 10cm and that on the third cell was 20cm. Air temperature, relative humidity and solar irradiance were measured using AWS (automatic weather system). Temperature on top surface and ceiling of the control cell and temperature on top surface, below soil and ceiling of green roof cells was measured. Evapotranspiration of the green roof cells were measured using weight changes. Compared with temperature difference on the control cell, temperature difference was greater on green roof cells. Between two green roof cells, the temperature difference was greater on the third cell with a thicker soil layer. Temperature differences below soil and on ceilings of green roof cells were found greater than those of the control cell. Between the green roof cells, there was no difference in the temperature reduction effects below soil and on ceilings based on substrate depth. In summary, green roof was found effective in temperature reduction due to evapotranspiration and shading effect.

The Estimation of Defect of Mono Cast Nylon by Infrared Thermography (열화상 기술에 의한 M.C 나일론의 내부 결함에 대한 평가)

  • Han, Jeong-Seb
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.81-86
    • /
    • 2009
  • Infrared thermography was used to determine the location, size, and depth of defects under the surface of M.C nylon. Defects were created in a specimen by back-drilling circular holes. These defects were located at the maximum temperature difference that occurred. The sizes of the defects could be calculated by means of the full width at half of the maximum temperature difference. The depth of a defect could be calculated by the peak time and the maximum temperature difference. The maximum temperature difference between a defect and normal part was decreased with the depth of the defect. And the peak time also slowly appeared with the depth of the defect.

An Effect on the Solution Crystallization Temperature Difference and Cooling Capacity of the Absorption Chiller by a Solution Cooler in the Absorber (흡수기내 용액 냉각기가 흡수식 냉동기의 용액 결정화 온도차와 냉각 용량에 미치는 효과)

  • Chin, Sung-Min;Lee, Jae-Heon;Jurng, Jong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1518-1523
    • /
    • 2003
  • The objective of the present work is to investigate an effect on the solution crystallization temperature difference and the cooling capacity of the absorption chiller by a solution cooler in the absorber. The cooling capacity of the absorption chiller can be higher, with the enhanced performance of the solution heat exchangers. But, because the solution crystallization temperature difference becomes smaller at the absorber inlet, the heat capacity of the solution heat exchangers might be limited by the danger of crystallization, which can cause the serious damages. In this paper, the heat capacity ratio of the solution cooler is defined as the ratio of the heat capacity of the solution cooler to that of the absorber. If it becomes larger in the additional type solution cooler, the solution crystallization temperature difference is augmented and the cooling capacity is also increased.

  • PDF

A Numerical Analysis on Thermal Stratification Phenomenon by In-Leakage in a Branch Piping

  • Park Jong-Il
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2245-2252
    • /
    • 2005
  • Thermal stratification in the branch piping of power plants can be generated by turbulent penetration or by valve leakage. In this study, a numerical analysis was performed to estimate the thermal stratification phenomenon by in-leakage in the SIS branch piping of nuclear power plant. Leakage rate, leakage area and leakage location were selected as evaluation factors to investigate the thermal stratification effect. As a result of the thermal stratification effect according to leakage rate, the maximum temperature difference between top and bottom of the horizontal piping was evaluated to be about 185K when the valve leakage rate was about 10 times as much as the allowed leakage rate. For leakage rate more than 10 times the allowed leakage rate, the temperature difference was rapidly decreased due to the increased mixing effect. In the result according to leakage area, the magnitude of temperature difference was shown in order of $3\%,\;1\%\;and\;5\%$ leakage area of the total disk area. In the thermal stratification effect, according to the leakage location, temperature difference when leakage occurred in the lower disk was considerably higher than that of when leakage occurred in the upper disk.