• Title/Summary/Keyword: Temperature Cooling Effect

Search Result 1,279, Processing Time 0.03 seconds

Characteristics of Meteorological Conditions and Air Pollution in a Valley City on Bad Visibility Days of the Cold Half Year (한후기 계곡지형 내 도시 시정악화 발생일의 기상 및 대기오염 특성 분석)

  • Kang, Jae-Eun;Song, Sang-Keun;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.22 no.6
    • /
    • pp.745-759
    • /
    • 2013
  • The characteristics of meteorological conditions and air pollution were investigated in a valley city (Yangsan) on bad visibility days (from 05:00 to 09:00 LST) of the cold half year (November 2008 to April 2009). This analysis was performed using the hourly observed data of meteorological variables (temperature, wind speed and direction, relative humidity, and 2 m and 10 m temperature) and air pollutants ($NO_2$, $SO_2$, $PM_{10}$, and $O_3$). In addition, visibility data based on visual measurements and a visibility meter were used. The bad visibility days were classified into four types: fog, mist, haze, and the mixture (mist+haze). The results showed that the bad visibility days of the four types in the valley city were observed to be more frequently (about 50% of the total study period (99 days except for missing data)) than (27%) those near coastal metropolitan city (Busan). The misty days (39%) in the valley city were the most dominant followed by the hazy (37%), mixture (14%), and foggy days (10%). The visibility degradation on the misty days in Yangsan was closely related to the combined effect of high-level relative humidity due to the accumulation of water vapor from various sources (e.g. river, stream, and vegetation) and strong inversion due to the development of surface radiative cooling within the valley. On the hazy days, the visibility was mainly reduced by the increase in air pollutant (except for $O_3$) concentrations from the dense emission sources under local conditions of weaker winds from the day before and stronger inversion than the misty days. The concentrations of $NO_2$, $PM_{10}$, and $SO_2$ (up to +36 ppb, $+25{\mu}g/m^3$, and +7 ppb) on the hazy days were a factor of 1.4-2.3 higher than those (+25 ppb, $+14{\mu}g/m^3$, and +3 ppb) on the misty days.

A Study on Crystallographic and Mossbauer Spectroscopic Properties of Magnetic Oxide (산화물 자성체의 결정학적 및 뫼스바우어 분광학적 특성 연구)

  • Park, Seung-Han
    • Korean Journal of Materials Research
    • /
    • v.9 no.7
    • /
    • pp.701-706
    • /
    • 1999
  • The crystal structure and magnetic properties of magnetic oxide system (F $e_2$ $O_3$)$_{5}$(A $l_2$ $O_3$)$_{4-x}$(G $a_2$ $O_3$)$_{x}$)SiO has been studied using X-ray diffraction and Mossbauer spectroscopy The changes of magnetic structure by the Ga ion substitution and the temperature variation have been investigated using Mossbauer spectroscopy, and the results are compared with those of the SQUIB measurements. Results of X-ray diffraction indicated that the crystal structures of the system change from a cubic spinel type to an orthorhombic via the intermediate region. This magnetic oxide system seems to be new kind of spinel type ferrites containing high concentration of cation vacancies. Various and complicated Mossbauer spectra were observed in the samples (x>0.2) at temperatures lower than room temperature. This result could be explained by freezing of the superparamagnetic dusters. On cooling and substitution, magnetic states of the system show various and multicritical properties. Unexpected dip in magnetization curves below 50K was observed in SQUID measurements. It was interpreted as an effect of spin canting including spin freezing or collective spin behavior.ior.r.

  • PDF

Viability and Acrosomal Status Changes Following Post-thawing Canine Spermatozoa (개 정자의 동결융해 후 생존성 및 첨체의 변화)

  • 이영락;이성림;강태영;최상용
    • Journal of Embryo Transfer
    • /
    • v.18 no.1
    • /
    • pp.51-59
    • /
    • 2003
  • This study was carried out to evaluate the effect of different freezing and thawing rates on the viability, motility and acrosomal changes of frozen canine spermatozoa. The ejaculated semen was extended with Tris-egg yolk buffer containing 8% glycerol and equilibrated for 60 min after cooled to 4$^{\circ}C$ for 58 min. The straws were cryopreserved gradually by slow-cooling at different distance(6, 10 and 17 cm, respectively) from the liquid nitrogen (L$N_2$) to achieve temperature rate of 3, 8.9 and 19$^{\circ}C$ /min. Thawing of the straws was performed in a water bath fur 2 min at 37$^{\circ}C$ and 55$^{\circ}C$ , respectively. The motility of frozen-thawed spermatozoa was assessed by phase-contrast microscopy. To assess their viability and acrosome content, spermatozoa were stained with a vital stain and Fluorescence conjugated lectin Pisum Savitum Agglutinin (FITC/PAS), respectively. Concentration of the ejaculated fresh semen was normal range of 3.44 $\times$ 10$^{8}$ /ml. Freezing temperature were reduced to -110, -70 and -35$^{\circ}C$, as higher distance from liquid nitrogen, 6, 10 and 17 cm, respectively. Freezing at 3$^{\circ}C$/min in distance of 17 cm from liquid nitrogen yielded better motility, viability and rate of intact acrosome than 8.9 or 19$^{\circ}C$/min and the optimal thawing was 37$^{\circ}C$ for 2 min.

An experimental study of smoke extraction efficiency along with ventilation building location in the mad tunnel (도로터널 내 환기소 위치별 방재 효율에 관한 실험적 연구)

  • Rie, Dong-Ho;Kim, Ha-Young;Yoon, Chan-Hoon;Kim, Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.3
    • /
    • pp.215-222
    • /
    • 2010
  • An experimental study was carried out on a reduced scale model tunnel to investigate the efficiency of disaster prevention at underground and ground ventilation equipments for the fire in road tunnels. Based on Froude modeling, the 1/50 scaled model tunnel (20 m long) was manufactured. The vertical shafts that are used in the analysis of efficiency of disaster prevention are the two models that had considered when the real tunnels are designed and the amounts of smoke exhaust are applied the miniature of the real tunnels' smoke exhaust, 560 and $280\;m^3/s$. As the result of analysis, it is the possible the emissions of the entire quantity of CO gas through the vertical shafts. In the ground ventilation equipments, the concentration of CO is discharged 2.23~2,73 ppm smaller than the underground ventilation equipments. And the temperature rise in the ground ventilation equipments is $0.53{\sim}0.94^{\circ}C$ lower than in the underground ventilation equipments because of a cooling effect of the surface of the tunnel wall. As a result of analysis of CO concentration and the temperature rise in the modeling ventilation equipment, the position of ground ventilation equipment is more effective than the underground ventilation equipment in disaster prevention measures.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009 (설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo Young;Choi, Jong-Min;Baik, Yong-Kyu;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

Effect of Coolant on PEMFC Performance in Low Humidification Condition (저가습 조건에서 냉각 유체의 고분자전해질 연료전지에 대한 영향)

  • Lee, Hung-Joo;Song, Hyun-Do;Kwon, Jun-Taek;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • Proton exchange membrane fuel cell(PEMFC) performance could be affected by various factors such as cell temperature, total pressure, partial pressure of reactants and relative humidity. Hydrogen ion is combined with water to form hydronium ion [$H_3O^+$] and pass through membrane resulting electricity generation. Cooling system is needed to remove heat and other uses on large scale fuel cell. In case that collant conductivity is increased, fuel cell performance could be decreased because produced electricity could be leaked through coolant. In this study, triple distilled water(TDW) and antifreeze solution containing ethylene glycol was used to observe resistance change. Resistance of TDW was taken 28 days to reach preset value, and effect on fuel cell operation was not observed. Resistance of antifreeze solution was not reached to preset value up to 48 days, but performance failure occurred presumably caused by bipolar plate junction resulting stoppage resistance experiment. Generally PEMFC humidification is performed near-saturated operating conditions at various temperatures and pressures, but non-humidifying condition could be applied in small scale fuel cell to improve efficiency and reduce system cost. However, it was difficult to operate large scale fuel cell without humidifying, especially higher than $50{\sim}60^{\circ}C$. In case of small flux such as 0.78 L/min, temperature difference between inlet and outlet was occurred larger than other cases resulting performance decrease. Non-humidifying performance experiments were done at various cell temperature. When both of anode and cathode humidification were removed, cell performance was strongly depended on cell operating temperature.

The Time and Effect of Hypothermia in Early Stage of the Reversible Cerebral Focal Ischemic Model of Rat (백서의 가역성 뇌허혈 모형에서 저체온의 효과와 적용시기)

  • Choi, Byung-Yon;Jung, Byung-Woo;Song, Kwang-Chul;Park, Jin-Han;Kim, Seong-Ho;Bae, Jang-Ho;Kim, Oh-Lyong;Cho, Soo-Ho;Kim, Seung-Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.2
    • /
    • pp.167-179
    • /
    • 2000
  • Objective : We studied to clarify the effective time zone of mild hypothermic neural protection during ischemia and/or reperfusion after middle cerebral artery occlusion. Methods : In a reversible cerebral infarct model which maintained reperfusion of blood flow after middle cerebral artery occlusion for two hours, the size of cerebral infarction, cerebral edema and the extent of neurological deficit were observed and analyzed for comparison between the control and the experimental groups under hypothermia($33.5^{\circ}C$). The temporalis muscle temperature was reduced to $33.5^{\circ}C$ by surface cooling for two hours during middle cerebral artery occlusion for study group I. The following groups applied hypothermia for two-hour periods after reperfusion : group II(0-2 hours), group III(2-4 hours), and group IV(4-6 hours). They were rewarmed to $36.5^{\circ}C$ until sacrified at 2, 4, 6, 12, and 24 hours after reperfusion. Control group was maintained at normothermia without hypothermia. Results : In the experimental groups with hypothermia, the average value of the size of cerebral infarction($mean{\pm}SD$) was $1.97{\pm}1.65%$, which was a remarkable reduction over that of the control, $4.93{\pm}3.79%$. In the control, a progressive increase was shown in the size of infarction from point of reperfusion to 6 hours after reperfusion without further changes in size afterward. Intra-ischemic hypothermia(group I) prevented ischemic injury but did not prevent reperfusion injury. Group II examplified the most neural protective effect in comparison to the control group and group IV(p<0.05). The cortex was more vulnerable to reperfusion injury than the subcortex. Mild hypothermia showed more neural protective effects on the cortex than subcortex. Conclusion : The most appropriate time zone for application of mild hypothermia was defined to be within four hours following reperfusion.

  • PDF

Effect of High Pressure Freezing and Thawing Process on the Physical Properties of Pork (초고압 동결 및 해동방법이 돈육의 물리적 특성에 미치는 효과)

  • Shim, Kook-Bo;Hong, Geun-Pyo;Choi, Mi-Jung;Min, Sang-Gi
    • Food Science of Animal Resources
    • /
    • v.29 no.6
    • /
    • pp.736-742
    • /
    • 2009
  • This study was conducted to investigate the effect of various high pressure freezing and thawing treatments on the physical properties of pork. To compare the effects of the freezing and thawing process on meat quality, atmospheric freezing followed by running water thawing (AFRT), pressure shift freezing followed by running water thawing (SFRT), and pressure shift freezing and pressure assisted thawing (SFAT) were conducted at pressure of 250 MPa and cooling temperature of $-22^{\circ}C$. SAFT and SFRT showed a shorter phase transition time and total thawing time than AFRT. The pH value of treated samples increased significantly (p<0.05) compared to unfrozen meat. In addition, SFAT and SFRT showed a higher pHvalue than AFRT. Although the water holding capacity was significantly decreased (p<0.05) for SFAT and SFRT, SFRT reduced drip loss. In regards to color, SFAT and SFRT resulted in a significant increase in color parameters (p<0.05) relative to AFRT, while SFAT produced a higher L*-value. High pressure treatment significantly increased shear force (p<0.05) compared to AFRT, and, where SFRT showed the highest shear force. Therefore, these combined results indicated that the hydrostatic pressure treatment improved the functional properties of pork and increased the freezing and thawing rate.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

The Effect of Chemical Composition and Sintering Temperature on the Experiment of Physical Properties of Ni-Zn Ferrite (Ni-Zn Ferrite의 조성성분 및 소결온도에 따른 물리적 특성의 실험적 연구)

  • Koh, Jae-Gui
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.5
    • /
    • pp.255-260
    • /
    • 2006
  • The basic composition of Ni-Zn ferrite was $(Ni_{0.35}Cu_{0.2}Zn_{0.45})_{1.02}(Fe_2O_3)_{0.98}$ (group A) and $(Ni_{0.4}Cu_{0.2}Zn_{0.4})_{1.02}(Fe_2O_3)_{0.98}$(group B) with additional 0.1 mol% $CaCO_3$ and 0.03 mol% $V_2O_5$. For high permeability and acceleration of grain growth, $CaCO_3$ and $V_2O_5$ was added. The mixture of the law materials was calcinated at $600^{\circ}C$ for 2 hours and then milled. The compacts of toroidal type were sintered at different temperature ($1,050^{\circ}C,\;1,070^{\circ}C,\;1,100^{\circ}C$) for 2 hours in air followed by an air cooling. Then, effects of various composition and sintering temperatures on the microstructure and physical properties such as density, resistivity, magnetic induction, coercive force, initial permeability, quality factor, and curie temperature of the Ni-Zn ferrite were investigated. The density of the Ni-Zn ferrite was $4.90{\sim}5.10g/cm^3$, resistivity revealed $10^8{\sim}10^{12}{\Omega}-cm$. The average grain size increased with the increase of sintering temperatures. The magnetic properties obtained from the aforementioned Ni-Zn ferrite specimens were 4,000 gauss for the maximum induction, 0.25 oersted for the coercive force, 2,997 for the initial permeability, 208 for the quality factor, and $202^{\circ}C$ for the curie temperature. The physical properties indicated that the specimens could be utilized as the core of microwave communication and high permeability deflection yoke of high permeability.