• Title/Summary/Keyword: Temperature Control Valve

Search Result 252, Processing Time 0.028 seconds

Characteristics of Heat Transfer in a Heat pipe Controlled by Solenoid Valve (전자 밸브에 의해서 제어되는 히트파이프의 전열 특성)

  • Jun, C.H.;Jang, Y.S.;Kim, O.G.
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.103-111
    • /
    • 1997
  • The purpose of this research is the study of characteristics of heat transfer in a heat pipe controlled by solenoid valve. A solenoid valve located to the adiabatic section between evaporator and condenser of heat pipe was used to control the valve action for effective energy transfer of the industrial exchanger machine. By the results presented in this study temperature difference between evaporator and condenser increases with increasing the temperature frequency and with decreasing the temperature amplitude. When inclination angle and flow rate of cooling water increases, the temperature amplitude is reached to the steady state rapidly with increasing the temperature frequncy.

  • PDF

Steam Temperature Control of Attemperator in Thermal Power Plant (화력발전소에서 과열저감기의 증기온도제어)

  • Shin, Hwi-Beom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.40-48
    • /
    • 2011
  • An attemperator is a part of the 4-stage superheater in the boiler system of the thermal power plant. The attemperator receives the over-heated steam and makes the steam with proper temperature by adjusting the control valve of the cold steam. In this paper, the attemperator is modeled considering physical point of view and the linearized model is derived for the control purpose. To overcome the integral windup phenomenon due to the opening limitation of the control valve, an anti-windup PI controller is proposed to the attemperator and compared with the PI controller operated in the thermal power plant in view of control performance.

A Study of wear and Matching of Diesel Engine Exhaust Valve and Seat Insert Depending on Valve Materials (디젤엔진 배기밸브와 시트 인서트의 밸브 재질에 따른 마모 및 매칭성 연구)

  • Kim, Yang-Soo;Chun, Keyoung-Jin;Hong, Jae-Soo;Chung, Dong-Teak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.6
    • /
    • pp.108-115
    • /
    • 2008
  • The wear on engine valve and seat insert is one of the most important factors affecting engine performance. The engine valve and seat insert must be able to withstand the severe environment that is created by: high temperature exhaust gases generated while the engine is running, rapid movement of the valve spring, high pressure generated in the explosive process. In order to study such problems, a simulator has been developed to generate and control high temperatures and various speeds during motion. The wear simulator is considered to be a valid simulation of the engine valve and seat insert wear process with various speeds during engine activity. This work focused on the test of various degrees of wear on four different exhaust valve materials such as HRV40, HRV40-FNV (face nitrided valve), STL #32, STL #6,. Throughout all tests performed in this study, the outer surface temperature of the seat insert was controlled at $350^{\circ}C$, the cycle number was $4.0{\times}10^6$, the test load was 6860 N, the fuel was LPG the test speed was 20 Hz (2400 RPM) and the seat insert material was HVS1-2. The mean (standard deviation) maximum roughness of the exhaust valve and seat insert was $25.44\;(3.16)\;{\mu}m$ and $27.53\;(3.60)\;{\mu}m$ at the HRV40, $21.58\;(2.38)\;{\mu}m$ and $25.94\;(3.07)\;{\mu}m$ at the HRV40-FNV, $36.73\;(8.98)\;{\mu}m$ and $61.38\;(7.84)\;{\mu}m$ at the STL #32, $73.64\;(23.80)\;{\mu}m$ and $60.80\;(13.49)\;{\mu}m$ at the STL #6, respectively. It was discovered that the maximum roughness of exhaust valve was lower as the high temperature hardness of the valve material was higher under the same test conditions such as temperature, test speed, cycle number, test load and seat insert material. The set of the HRV40-FNV exhaust valve and the HVS1-2 seat insert showed the best wear resistance.

A Study on the Design of Liquid Flow Control Valves for the Pants and Ships(II) (플랜트 및 선박의 액체용 우량제어밸브 설계에 관한 연구(II))

  • 최순호;배윤영;김태한;한기남;주경인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.1-9
    • /
    • 1995
  • The processing paper has devoted to the theory of the flow equations, the basic derivative procedure, the meaning of a valve flow coefficient $C_v$, the valve Reynolds R$R_{ev}$ and its application for liquid control valves, which applicable under the condition of a non-critical flow and the case of piping geometry factor $F_p$=1.0. However there is no information on the effects of fittings, a critical flow and the flow resistance coefficient of a valve equivalent to that of pipe which is conveniently used in the piping design. Since the piping systems of plants or ships generally contain various fittings such as expanders and reducers due to different size between pipes and valves and there may occur a critical flow, that a mass flowrate is maintained to be constant, due to the pressure drop in a piping when a liquid is initially maintainder ar a saturated temperature or at nearby corresponding to upstream pressure, system designer should have a knowledge of the effect to flow due to fittings and the critical flow phenomenon of a liquid. This study is performed to inform system designers with the critical flow phenomenon of a liquid, a valve resistance coefficient, a valve geometry factor and their applications.

  • PDF

A Study on the Lubrication Flow Distribution in a Six-speed Automatic Transmission Valve Body (6속 자동변속기 밸브바디의 윤활오일유량 분배 특성 연구)

  • Kim, Jin-Yong;Na, Byung-Chul;Lee, Kye-Cheul
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • In general, a valve body of the automatic transmission(AT) is controlled by the clutch, the brake and lubricating oil flow in a hydraulic system and lubricant flow for each valve can be adjusted independently. To increase the lifetime of AT, the lubrication flow rate in a valve body for a 6 speed AT based parallel hybrid electric vehicle must be provided with proper oil distribution and control. In this study, we carried out several experiments without the inner parts of AT and with a AT assembly. The variation of the flow rate on oil temperature and pressure between an oil supply port and the outlets of the lubrication port was evaluated and analyzed. In the case of AT without the inner parts, it was evident that as the oil required for an operation of the clutch and brake was discharged from the outlet port, the flow rate from each lubrication port is decreased. However, the flow rate of the AT assembly was slightly increased. In addition, the lubrication flow rate was increased with increasing the oil temperature, and also it was reduced with increasing the oil pressure. Details of the resulting data are discussed.

Design of electrical gas valve system for sing1e crystalline growth (단결정 성장을 위한 자동 가스 조절용 전동밸브 설계)

  • Cho, Hyeon-Seob;Kim, Jong-Ok;Min, Byoung-Cho;Kim, Hee-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2796-2798
    • /
    • 2000
  • It is a quite quality concerning to control temperature of single crystalline growth as it does when you get most of heat treating products. It is also important factor to control temperature when you make the $Al_{2}O_3$(single crystalline) used to artificial jewels. glass of watches. heat resistant transparent glasses. Thus. it is a major interest to get the proper temperature in accordance with the time process while you are making mixture of oxygen and hydrogen to have the right temperature. In this paper. we will study of electrical valve positioning system for the gas mixture to improve the quality of products.

  • PDF

Design of thermal system using 3-way valve and PTC to which a solar module (태양광 모듈이 부착된 PTC 집열기 및 3웨이 밸브를 이용한 온열 시스템 설계)

  • Song, Je-Ho;Lee, In-Sang;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.454-459
    • /
    • 2017
  • In this study, a thermal system was designed using a 3-way valve and PTC attached to a solar module. This design could help solve the problem of rising fossil fuel costs caused by limited reserves and environmental problems resulting from fossil fuel use. The thermal system is a hot-air and heating control system composed of a temperature sensor part, mode setting part (for hot air and heating modes), supply part, and thermal system control part. The temperature sensor part has piping and an indoor temperature display, and the temperature setting part has multiple monitoring functions. The mode setting part switches between hot air and heating modes and can be used to set the temperature. The thermal system control part performs functions such as PTC control and temperature setting, PTC day and night and time selection, hot air and heating control, and three-way valve selection. The results verify that the system operates with stable response speeds of $680{\mu}s$ in the temperature sensor part, $700{\mu}s$ in the mode setting part, and $610{\mu}s$ in the thermal system control part.

COMBUSTION STABILITY OF DIESEL-FUELED HCCI

  • Shi, L.;Deng, K.;Cui, Y.
    • International Journal of Automotive Technology
    • /
    • v.8 no.4
    • /
    • pp.395-402
    • /
    • 2007
  • Homogeneous Charge Compression Ignition (HCCI) shows great potential for low $NO_x$ emission but is hampered by the problem of no direct method to control the combustion process. Therefore, HCCI combustion becomes unstable easily, especially at lower and higher engine load. This paper presents a method to achieve diesel-fueled HCCI combustion, which involves directly injecting diesel fuel into the cylinder before the piston arrives at top dead center in the exhaust stroke and adjusting the valve overlap duration to trap more high temperature residual gas in the cylinder. The combustion stability of diesel-fueled HCCI combustion and the effects of engine load, speed, and valve overlap on it are the main points of investigation. The results show that: diesel-fueled HCCI combustion has two-stage heat release rate (low temperature and high temperature heat release) and very low $NO_x$ emission, combustion stability of the HCCI engine is worse at lower load because of misfire and at higher load because of knock, the increase in engine speed aids combustion stability at lower load because the heat loss is reduced, and increasing negative valve overlap can increase in-cylinder temperature which aids combustion stability at lower load but harms it at higher load.

Development and Performance Analysis of Gas Generator with Plunger-type Flow Control Valve for Ducted Rocket : Part I (Plunger 타입 유량조절장치를 적용한 덕티드 로켓용 가스발생기 개발 및 성능분석 : Part I)

  • Lee, Jungpyo;Han, Seongjoo;Cho, Sungbong;Kim, Kyungmoo;Lim, Jaeil;Lee, Kiyeon
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.3
    • /
    • pp.79-86
    • /
    • 2021
  • For a preliminary study on a thrust-throttleable Variable Flow Ducted Rocket, a gas generator and flow control valve were developed, and ground combustion tests were performed. The gas generator and flow control valve operated at the required performance level for parameters, such as heat-resistance, combustion-time, pressure, and temperature. The combustion characteristics of a fuel-rich solid propellant mixed with Boron/MgAl/AP, etc., were also analyzed. A Plunger-type flow control valve was designed to control the discharge flow area, and it was confirmed that the flow control valve was able to control the combustion gas flow rate and pressure. However, due to the reduction of the discharge flow area caused by adhesion of combustion products, the combustion pressure continuously increased. The analysis of the pressure increase is covered in Part 2 of this paper.

A Study on the Reliability Improvement of the Turbine Control Valve System in Nuclear and Thermal Power Plants (원자력/화력발전소의 터빈제어밸브시스템의 신뢰성 향상에 관한 연구)

  • Yang, Jong Dae;Yang, Seok Jo;Lee, Yong Bum
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.93-100
    • /
    • 2019
  • Nuclear and thermal power plants must provide the turbines with an appropriate degree of high temperature and high pressure steam, to produce the optimum electricity. Additionally, in the event of system and power system failure during electrical production, the steam is immediately disabled, to protect the turbines and generators rotating at high speed. The plant thus uses a special steam control valve system for turbine control, which is opened by force of the hydraulic servo actuator and closed by a large steel spring force. In this study, the causes of failure of the turbine control valve system, a key device of the power plants, were analyzed, and the causes of failure were improved relative to reliability of the equipment.