• Title/Summary/Keyword: Temperature Calibration Curve

Search Result 76, Processing Time 0.026 seconds

Calibration Equation for VTA Including the Effect of Ambient Temperature Drift (온도변화를 고려한 가변온도형 열선유속계의 교정식)

  • Lee, Shin-Pyo;Kauh, S.-Ken
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.99-104
    • /
    • 2000
  • Calibration equation for Variable Temperature Anemometer(VTA) has been tested for measured velocity-output data and the calibration process has been compared with that of Constant Temperature Anemometer(CTA). VTA has greater sensitivity than that of any other conventional anemometers, but to be more popular technique in flow field measurement, simple, accurate and well established calibration process should be suggested. To meet this purpose, similar calibration method used for CTA has been adopted for VTA and finally calibration equation for VTA including the effect of temperature drift has been proposed.

  • PDF

Effects of the in-process calibration from IR detector for thermal diffusivity measurement by laser flash method (레이저 섬광법에 의한 열확산계수 측정시 적외검출소자에서 실시간 온도보정이 미치는 영향)

  • 이원식;배신철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.795-802
    • /
    • 1998
  • For measuring the thermal diffusivity by laser flash method, raw data have to be calibrated using temperature data. We have developed in-process calibration method and polynomial calibration in which thermal diffusivity can be calibrated during measuring, This method is different from existing temperature pre-process calibration method and exponential calibration having various source of error. Using this new calibration method, measurement accuracy was improved about 1∼2% compare to the value by the existing method. We also studied more accurate fitting curve as in Figure 4 was shown the result of measuring output characteristics of IR radiometer with temperature. As illustrated in data, in-process calibration method and polynomial calibration equation is proper than pre-process calibration method and exponential calibration.

  • PDF

Temperature Calibration of a Specimen-heating Holder for Transmission Electron Microscopy

  • Kim, Tae-Hoon;Bae, Jee-Hwan;Lee, Jae-Wook;Shin, Keesam;Lee, Joon-Hwan;Kim, Mi-Yang;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • v.45 no.2
    • /
    • pp.95-100
    • /
    • 2015
  • The in-situ heating transmission electron microscopy experiment allows us to observe the time- and temperature-dependent dynamic processes in nanoscale materials by examining the same specimen. The temperature, which is a major experimental parameter, must be measured accurately during in-situ heating experiments. Therefore, calibrating the thermocouple readout of the heating holder prior to the experiment is essential. The calibration can be performed using reference materials whose phase-transformation (melting, oxidation, reduction, etc.) temperatures are well-established. In this study, the calibration experiment was performed with four reference materials, i.e., pure Sn, Al-95 wt%Zn eutectic alloy, NiO/carbon nanotube composite, and pure Al, and the calibration curve and formula were obtained. The thermocouple readout of the holder used in this study provided a reliable temperature value with a relative error of <4%.

Development of Radiation Thermometer using InSb Photo-detector (인듐안티모나이드(InSb) 소자를 이용한 적외선 방사온도 계측시스템의 개발연구)

  • Hwang, Byeong-Oc;Lee, Won-Sik;Jhang, Kyung-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.46-52
    • /
    • 1995
  • This paper proposes methodologies for the development of radiation thermometer using InSb photo-detector of which spectral sensitivity is excellent over the wave length range of 2 .mu. m .approx. 5 .mu. m. The proposed radiation thermometer has broad measurement range from normal to high, up to more than 1000 .deg. C, with high accuracy, and can measure temperature on the material surface or heat emission noncontactely with high speed. Optical system was consisted of two convex lens with foruslength of 15.2mm for infrared lay focusing, Ge filter to cut the short wave length components and sapphire filter to cut the long wave length components. The cold shielded was installed in the whole surface of the light-absorbing element to remove the error- mometer, calibration using black body furnace which has temperature range of 90 .deg. C .approx. 1100 .deg. C was carried out, and temperature calaibration curve was obtained by exponential function curvefitting. The result shows maximum error less than 0.24%(640K .+-. 1.6K) over the measurement range of 90 .deg. C .approx. 700 .deg. C, and from this result the usefulness of the developed thermometer has been confirmed.

  • PDF

Fabrication and Characteristic of an InSb Mognetic Flvxmeter (InSb 자속계의 제작과 그 특성에 관한 연구)

  • 윤재강;유용택
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.6
    • /
    • pp.5-8
    • /
    • 1975
  • An Insb magnetic fluxmeter was made of InSb Single Crystal that was grown by Bridgemannmethods and then purified by vapor cone refining method. We investigated some properties of the InSb magneto fluxmeter. It was found that the resistivity and the Hall Coefficient of this single Crystal Were 4.4${\times}10^{-2}{\Omega}$ and $4.5\textrm{cm}^3$/Coul, respectively, at room temperature. The Characteristic Curve of the InSb magnetic fluxmeter between the magnetic field the Hall voltage, with the Current flowing through the element a Parameter, had good lineanty i.e., We obtained a linear Calibration Curve of the flwmeter. The fluxmeter erved the purpose well enough up to 5 k-gaus.

  • PDF

Development of Portable System for Measuring pH in Blood (휴대용 혈중pH 측정시스템의 구현)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

Realization of silver fixed-point and application for the high temperature platinum resistance thermometry using the gas-pressure controlled sodium heat-pipe furnace (가스압력조절식 나트륨 열관전기로를 이용한 은 고정점 실현과 고온백금저항온도 계측에의 응용)

  • Gam, K.S.;Choi, I.M.;Yang, I.;Kim, Y.G.
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.116-121
    • /
    • 2009
  • Pressure-controlled sodium heat pipe furnace was designed and fabricated, and its characteristics was investigated. Pressure control system was controlled within ${\pm}0.5\;Pa$ at 150 kPa and the stability of pressure was decreased to ${\pm}2.5\;Pa$, when the pressure-controlled system connected with the heat pipe. The melting curve of Ag fixed-point realized well by the adiabatic method using the pressure-controlled sodium heat pipe furnace and its accuracy showed ${\pm}2.27\;mK$ from the calculation of 20% to 80% at the plateau. The freezing curve of Ag fixed-point also realized and its plateau value was 2.23 mK lower than that of the melting curve.

Simultaneous Temperature and Velocity Fields Measurements near the Boiling Point

  • Doh, Deog-Hee;Hwang, Tae-Gyu;Koo, Bon-Young;Kim, Seok-Ro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.531-542
    • /
    • 2007
  • Simultaneous measurement technique for temperature and velocity fields near a heated solid body has been constructed. The measurement system consists of a 3-late CCD color camera, a color image grabber, a 1ighting system, a host computer and a software for the whole quantification process. Thermo Chromic Liquid Crystals (TCLC) was used as temperature sensors. A neural network was used to get a calibration curve between the temperature and the color change of the TCLC in order to enhance the dynamic range of temperature measurement. The velocity field measurement was attained by the use of the fray-level images taken for the flow field, and by introducing the cross-correlation technique. The temperature and the velocity fields of the forced and the natural convective flows neat the surface of a cartridge heater were measured simultaneously with the constructed measurement system.

An Estimation of the Temperature Distribution and the Soot Density in Diesel Flame with the Two-Color Method using Image Analysis System (화상 2색법에 의한 디젤화염의 온도분포 및 매연농도의 평가)

  • 방중철;최익수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.5
    • /
    • pp.60-69
    • /
    • 2003
  • The simplified two-color method is proposed which can estimate the temperature distribution and the soot density of the whole flame with the image analysis of the high-speed photographs. The factors influenced on its processing were examined, for example, the selection of the wave length, the kind of films, the preparation of the calibration curve between the radiance of flame and the luminance temperature. The simplified two-color method reported in this paper can be used as a tool for the improvement of the combustion process in direct injection diesel engine.

Characterization of A Catalystic Gas Sensor for Measuring Heat Content of Natural Gas (천연가스의 열용량을 측정하기 위한 촉매가스센서의 특징)

  • Lee K. Y.;Maclay G. J.;Stetter J. R.
    • 한국가스학회:학술대회논문집
    • /
    • 1997.09a
    • /
    • pp.229-235
    • /
    • 1997
  • A low power (300 mW) catalytic bead combustible gas sensor is developed and utilized with a computer controlled sampling system for measuring heat content of natural gas. The heat content of gas is proportional to the change in the energy required to exposure to the sample of combustible gas. The heat content of natural gas samples ranging 36.30 - 39.88 MJ/$m^3$ is measured in the range of approximately $1\%$ error, which is comparable to its nominal heat content. Each gas has a slightly different curve of sensitivity vs. sensor temperature. Thus there Is no temperature at which all sensitivities are equal. In calibration process the choice of a optimum operating temperature is an important factor that influences the overall performance of the measurement system.

  • PDF