• 제목/요약/키워드: Temperature Analysis

검색결과 19,278건 처리시간 0.04초

도시내 용도지역의 토지피복형태가 열섬현상에 미치는 영향 (The Influence of Land Cover and Zoning on the Urban Heat Island in Cheongju)

  • 조성모;윤용한;류을렬;박봉주;김원태
    • 한국환경과학회지
    • /
    • 제18권2호
    • /
    • pp.169-176
    • /
    • 2009
  • The present study observed temperature in order to identify factors affecting temperature by zoning and to measure the intensity of their impact on temperature. The empirical results of analyzing observed data are as follows. In order to make up for multicollinearity, a problem in multiple regression analysis, and to give more specific explanations, this study conducted factor analysis and obtained desirable data with adequacy and statistical significance. In the correlation matrix, factors decreasing temperature were planted areas, water surfaces and grasslands, and those increasing temperature were bare grounds, paved areas, and building area. According to land cover patterns, commercial areas had the highest temperature lowering effect. Through the rotated component matrix, we found that factors are grouped into those decreasing temperature, those increasing temperature, and those with low significance in increasing or decreasing temperature. In order to solve the problem of multicollinearity in multiple regression analysis, we performed factor analysis between the land use patterns and temperature and confirmed the usability of factor analysis as a new analysis method in urban heat island.

기후변화에 따른 낙동강 유역의 기온 경향성 및 수온과의 탄성도 분석 (Analysis for Air Temperature Trend and Elasticity of Air-water Temperature according to Climate Changes in Nakdong River Basin)

  • 손태석;임용균;백명기;신현석
    • 한국물환경학회지
    • /
    • 제26권5호
    • /
    • pp.822-833
    • /
    • 2010
  • Temperature increase due to climate changes causes change of water temperature in rivers which results in change of water quality etc. and the change of river ecosystem has a great impact on human life. Analyzing the impact of current climate changes on air and water temperature is an important thing in adapting to the climate changes. This study examined the effect of climate changes through analyzing air temperature trend for Nakdong river basin and analyzed the elasticity of air-water temperature to understand the effect of climate changes on water temperature. For analysis air temperature trend, collecting air temperature data from the National Weather Service on main points in Nakdong river basin, and resampling them at the units of year, season and month, used as data for air temperature trend analysis. Analyzing for elasticity of air-water temperature, the data were collected by the Water Environment Information system for water temperature, while air temperature data were collected at the National Weather Service point nearest in the water temperature point. And using the results of trend analysis and elasticity analysis, the effect of climate changes on water temperature was examined estimating future water temperature in 20 years and 50 years after. It is judged that analysis on mutual impact between factors such as heat budget, precipitation and evapotranspiration on river water temperature affected by climate changes and river water temperature is necessary.

온간 단조 공정에서의 열전달 계수 (Heat transfer coefficients for F.E analysis in warm forging processes)

  • 강종훈;고병호;제진수;강성수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.138-143
    • /
    • 2005
  • Finite Element analysis is widely applied to elevated temperature forging processes and shows a lot of information of plastic deformation such as strain, stress, defects, damages and temperature distributions. In highly elevated temperature deformation processes, temperature of material and tool have significant influence on tool life, deformation conditions and productivities. To predict temperature related properties accurately, adequate coefficients of not only contact heat transfer between material and dies but also convection heat transfer due to coolants are required. In most F.E analysis, too higher value of contact heat transfer coefficient is usually applied to get acceptable temperature distribution of tool. For contact heat transfer coefficients between die and workpiece, accurate values were evaluated with different pressure and lubricants conditions. But convection heat transfer coefficients have not been investigated for forging lubricants. In this research, convection heat transfer coefficients for cooling by emulsion lubricants are suggested by experiment and Inverse method. To verify acquired convection and contact heat transfer coefficients, tool temperature was measured for the comparison between measured tool temperature and analysis results. To increase analysis accuracy, repeated analysis scheme was applied till temperature of the tool got to be in the steady-state conditions. Verification of heat transfer coefficients both contact and convection heat transfer coefficients was proven with good accordance between measurement and analysis.

  • PDF

넙치양식장 환경에 따른 생산성에 관한 연구 (An Environmental Effect on Productivity of Flounder Culture Farms)

  • 어윤양
    • 수산경영론집
    • /
    • 제42권3호
    • /
    • pp.79-93
    • /
    • 2011
  • Water temperature of Oliver flounder farm affects Oliver flounder growth and mortality rate. In laboratory experimental tanks, optimal water temperature was $22.5^{\circ}C$($21{\sim}24^{\circ}C$) and cultivatable water temperature was $12{\sim}28^{\circ}C$. The purpose of this study is to identify applicable and useful water temperature of Oliver flounder farm in case of actual farming. The data applied in the analysis was collected from Jeju island. In the study, various analytical methods including productivity analysis, regression analysis, statistical analysis were conducted for 13 Oliver flounder culture farms. The result of analysis can be summarized as follows : First, growth rate on the Oliver flounder culture farms was related to mean of water temperature, variation of water temperature and low water temperature. Second, survival rate on the Oliver flounder culture farms was related to mean of water temperature. In case of including Oliver flounder stocking density, defined as the surface area of Oliver flounder per $m^2$ of water surface area, survival rate strongly related to mean of water temperature, variation of water temperature, cultivating capability and stocking density. Third, production weight per $m^2$ of water surface area was strongly related to mean of water temperature, low water temperature and cultivating capability. Growth rate and survival rate was analyzed into mediate variable character.

Daily Changes in Red-Pepper Leaf Surface Temperature with Air and Soil Surface Temperatures

  • Eom, Ki-Cheol;Lee, Byung-Kook;Kim, Young-Sook;Eom, Ho-Yong
    • 한국토양비료학회지
    • /
    • 제47권5호
    • /
    • pp.345-350
    • /
    • 2014
  • This study was conducted to investigate the changes in daily surface temperature of red pepper leaf compared to air and soil surface temperature. The maximum, minimum and average daily temperatures of red pepper leaf were 27.80, 11.40 and $19.01^{\circ}C$, respectively, which were lower by 0.10, 7.60 and $3.86^{\circ}C$ than air temperature, respectively, and lower by 15.00, 0.0 and $4.38^{\circ}C$ than soil surface temperature, respectively. Mean deviations of the difference between measured and estimated temperature by the E&E Model (Eom & Eom, 2013) for the air and surface temperature of red pepper leaf and soil were 0.64, 1.82 and $4.77^{\circ}C$, respectively. The relationships between measured and estimated scaled factor of the air and surface temperature of red pepper leaf and soil were very close to the 1:1 line. Difference between air and surface temperature of red pepper leaf showed a linear decreasing function with the surface temperature of red pepper leaf. Difference between soil surface temperature and air and surface temperature of red pepper leaf linearly increased with the soil surface temperature.

보일러 헤더 기동시의 탄성 크리프 해석에 의한 열응력 평가 (Thermal Stress Evaluation by Elastic-Creep Analysis during Start-up of Boiler Header)

  • 신규인;윤기봉
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.17-22
    • /
    • 2009
  • Thermal stress and elastic creeping stress analysis was conducted by finite element method to simulate start-up process of a boiler header of 500MW standard fossil power plant. Start-up temperature and operating pressure history were simplified from the real field data and they were used for the thermal stress analysis. Two kinds of thermal stress analysis were considered. In the first case only temperature increase was considered and in the second case both of temperature and operating pressure histories were considered. In the first analysis peak stress was occurred during the temperature increase from the room temperature. Hence cracking or fracture may occur at the temperature far below the operating maximum temperature. In the results of the second analysis von Mises stress appeared to be higher after the second temperature increase. This is due to internal pressure increase not due to the thermal stress. When the stress components of radial(r), hoop($\theta$) and longitudinal(z) stress were investigated, compression hoop stress was occurred at inner surface of the stub tube when the temperature increased from room temperature to elevated temperature. Then it was changed to tension hoop stress and increased because of the operating pressure. It was expected that frequent start-up and shut-down operations could cause thermal fatigue damage and cracking at the stub tube hole in the header. Elastic-creeping analysis was also carried out to investigate the stress relaxation due to creep and stabilized stress after considerable elapsed time. The results could be used for assessing the creep damage and the residual life of the boiler header during the long-tenn service.

강제 재생 방식 DPF 내부의 온도 분포 특성에 관한 수치해석 (Numerical Analysis on the Characteristics of Temperature Distribution in an Active Regeneration DPF Type)

  • 박성천;이한성
    • 한국기계기술학회지
    • /
    • 제13권2호
    • /
    • pp.55-61
    • /
    • 2011
  • This study analyzed on the characteristics of temperature distribution in an active regeneration DPF using computer simulation. In order to verify the boundary condition of analysis, results of temperature distribution in DPF are compared between experimental and computer simulation. Using this boundary condition, temperature distribution and filter's durability in DPF analyzed according to various operating conditions. The results of computational analysis are agreed well with experimental ones from the tendency of temperature distribution of axis and radius direction. The temperature increases and the axial temperature gradients in DPF according to velocity of exhaust gas are lowered as the high velocity of exhaust gas. But the temperature gradients of radius direction at exit side in DPF are grown as the high velocity of exhaust gas. The results according to inlet temperature of exhaust gas show that the increase ratios of temperature in DPF are grown as the high temperature of exhaust gas.

Multi-physics Analysis for Temperature Rise Prediction of Power Transformer

  • Ahn, Hyun-Mo;Kim, Joong-Kyoung;Oh, Yeon-Ho;Song, Ki-Dong;Hahn, Sung-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.114-120
    • /
    • 2014
  • In this paper, a method for multi-physics analysis of the temperature-dependent properties of an oil-immersed transformer is discussed. To couple thermal fields with electromagnetic and fluid fields, an algorithm employing a user defined function (UDF) is proposed. Using electromagnetic analysis, electric power loss dependent on temperature rise is calculated; these are used as input data for multi-physics analysis in order to predict the temperature rise. A heat transfer coefficient is applied only at the outermost boundary between transformer and the atmosphere in order to reduce the analysis region. To verify the validity of the proposed method, the predicted temperature rises in high-voltage (HV) and low-voltage (LV) windings and radiators were compared with the experimental values.

LNG선박용 글로브 밸브 구조해석에 관한 연구 (A Study on Structural Analysis of Globe Valve for LNG Carrier)

  • 김동균;김정환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.1013-1019
    • /
    • 2007
  • This paper is about structural analysis of globe valve for controlling cryogenic LNG's flow or stop in normal temperature. The used valve is demanded safety resistance for inner pressure and temperature variation caused by using it in cryogenic, high pressure surrounding. This study evaluates for safety resistance for inner pressure and temperature variation by heat transfer analysis in cryogenic surrounding, heat stress analysis in temperature variation and deformation analysis in high pressure.

온간단조 공정의 계면열전달계수 (Contact Heat Transfer Coefficient for Finite Element Analysis in Warm Forging Processes)

  • 강종훈;고병호;제진수;강성수
    • 소성∙가공
    • /
    • 제15권3호
    • /
    • pp.183-188
    • /
    • 2006
  • Heat transfer coefficients have great influence on finite element analysis results in elevated temperature forging processes. Experimentally calculated contact heat transfer coefficient is not suitable for one-time finite element analysis because analyzed temperature will be appeared to be too low. To get contact heat transfer coefficient for one-time finite element analysis, tool temperature in operation was measured with thermocouple and repeated finite element analysis was performed with experimentally calculated contact and cooling heat transfer coefficient. Surface temperature of active tool was obtained comparing measurement and analysis results. Contact heat transfer coefficient for one-time finite element analysis was achieved analyzing surface temperature between repeated finite element analysis and one-time finite element analysis results.