• 제목/요약/키워드: Temperature & Humidity

검색결과 4,327건 처리시간 0.031초

NiO(Co0.25Mn0.75)2O3 and BaSrTiO3 thick films on alumina substrate as temperature and humidity ceramic multisensors

  • 오영제;이득용
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.343-348
    • /
    • 2009
  • $NiO{\cdot}(Co_{0.25}Mn_{0.75})_2O_3$(Mn-Ni-Co) and $Ba_{0.5}Sr_{0.5}TiO_3$(BST) thick films were screen printed on Pt patterned alumina substrate to investigate the effects of sintering temperature on humidity and temperature sensing properties of ceramic sensors. A raise in sintering temperature increased resistance and B constant of the Mn-Ni-Co temperature sensor. This may have derived from the synergic effects of the reduction in charge carriers caused by the substitution of Co for Mn as well as the formation of microcracks from the difference in thermal expansion coefficients. Dependence of resistance on humidity of the Mn-Ni-Co temperature sensor, however, was not found. BST films sintered at temperatures in the range of $1100^{\circ}C$ to $1150^{\circ}C$ showed excellent humidity sensing properties. The BST humidity sensor was faster in its response than the Mn-Ni-Co temperature sensor. The humidity sensor, however, proved to be unstable under various temperatures, suggesting a need for a temperature stabilizing device. In contrast, the Mn-Ni-Co temperature sensor was stable under humid conditions.

양생직후 초기재령의 콘크리트 내부 온도와 상대습도의 측정 및 분석 (Investigation of Internal Temperature and Relative Humidity of Concrete Immediately After Mix and Placement)

  • 박철우;박영훈;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1065-1068
    • /
    • 2008
  • Concrete is still one most common construction materials even in railway structures. As structures become massive and mega-sized, the importance of early age concrete quality control becomes more significant. Among various factors, relative humidity and temperature are the primary factors governing the early age quality. Temperature raise due to cement hydration causes stress, which can develop to cracking with internal and/or external restraints. Exposure conditions including ambient temperature, humidity and wind also significantly affect the cracking behavior of early age concrete. Among many of studies on the early age concrete behavior, investigation on the variation of temperature and relative humidity internal of concrete is not common. That is in part because the difficulties in measuring the relative humidity and temperature inside the concrete. This study used a digital sensor with an appropriate logger to measure internal temperature and relative humidity. This direct measuring method is expected to provide more reliable and comprehensive data acquisition on the early age behavior of concrete.

  • PDF

콘크리트 내부 온습도 추정 및 탄산화 깊이 예측 (Estimation of Thermal Humidity Inside Concrete and Prediction of Carbonation Depth)

  • 박동천
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2021
  • The temperature and humidity inside concrete affects the depth of carbonation. In this study, the temperature and humidity inside concrete were predicted by the numerical method under the boundary conditions of ambient temperature, humidity, solar radiation, and wind. Using the results of the thermal humidity analysis, diffusion of carbon dioxide and the reaction of cement hydration products were calculated for carbonation depth.

  • PDF

차량 내 온, 습도 관계에 의한 실천공학교육적 문제해결 (Problem Solving about Practical Engineering Education based on Relationship of Temperature and Humidity in Vehicle)

  • 김진우;주강우
    • 실천공학교육논문지
    • /
    • 제9권2호
    • /
    • pp.149-153
    • /
    • 2017
  • 자동차센서는 차량제어에 필요한 인자들을 모니터링하여 얻어진 정보로부터 최적의 제어가 가능하도록 하는 역할을 하고 있다. 이러한 센서 중에서 운전자의 주행환경을 결정 짓는 것은 차량 내부의 온도 및 습도이며, 순간적으로 급변하는 특성이 있다. 이에 따라 차량 공조 시스템은 온도제어가 매우 복잡한데, 그 중에서도 온도 및 습도에 대한 관계를 명확히 규명하면 제어변수를 줄일 수 있다. 따라서 본 논문에서는 차량 내 온도 및 습도의 관계에 대해 서술하고 차량 내부의 온습도 제어 방식을 사례를 들어 제어 기술 측면에서의 문제해결 방법에 대해 제시한다.

Indoor Neutral Temperature Range using Temperature and Humidity Perception Assessment

  • Yang, Wonyoung
    • KIEAE Journal
    • /
    • 제16권5호
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: Indoor thermal comfort can be identified by combination of temperature, humidity, and air flow, etc. However, most thermal indexes in regard to thermal comfort are temperature dominant since it has been considered as a significant factor affecting to indoor thermal comfort The purposes of this study are to investigate indoor neutral temperature range of young Koreans with humidity perception, and to introduce a neutral temperature for temperature preference as well as temperature sensation in order to define the neutral temperature range chosen by occupants. It could be used as basic data for heating and cooling. Method: 26 research participants volunteered in 7 thermal conditions ($18^{\circ}C$ RH 30%, $18^{\circ}C$ RH 60%, $24^{\circ}C$ RH 30%, $24^{\circ}C$ RH 40%, $24^{\circ}C$ RH 60%, $30^{\circ}C$ RH 30%, $30^{\circ}C$ RH 60%) and completed subjective assessment in regard to temperature/humidity sensation and preference twice per condition in an indoor environmental chamber. Result: In RH 30%, sensation neutral temperature was $25.1^{\circ}C$ for men and $27.0^{\circ}C$ for women, and preference neutral temperature was $25.5^{\circ}C$ for men and $27.8^{\circ}C$ for women. In RH 60%, sensation neutral temperature was $23.6^{\circ}C$ for men and $25.9^{\circ}C$ for women, and preference neutral temperature was $23.4^{\circ}C$ for men and $26.3^{\circ}C$ for women. Neutral temperature increased with increasing relative humidity. Women were sensitive to humidity changes. Men expressed humidity changes as temperature variations. In most conditions, preference neutral temperatures were higher than sensation neutral temperatures, however, the preference neutral temperature for men in humid condition was lower than the sensation neutral temperature.

ATmega128를 이용한 온.습도 자동제어 모형 제작 (Design Clean Room of Controled Temperature and Humidity using ATmega128)

  • 김민구;구태회;김영민;심새로얼;소대화
    • 동굴
    • /
    • 제77호
    • /
    • pp.59-65
    • /
    • 2007
  • Nowaday, our life is closely related to temperature and the humidity. To control the temperature and the humidity have pursued the comfort environment. We develop that form ware is controled temperature and humidity that used the ATmega128. We embody home-automation system to use the ATmega128, temperature sensor, LCD, relay device and peltier device.

Implications of High Temperature and Low Humidity on the Hatching in the Silkworm, Bombyx mori L. Under LD 12 : 12 Condition

  • Reddy P. Lakshminarayana;Naik S. Sankar;Reddy N. Sivarami
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제11권2호
    • /
    • pp.139-143
    • /
    • 2005
  • The implications of temperature (25, 30 and $35^{\circ}C$) and relative humidity (RH; 60, 70 and $80\%$) on the hatching rhythmicity and hatching parameters (percentage and duration) were studied in the silkworm, Bombyx mori L. under natural photoperiod (LD 12 : 12). Disease free layings (DFLs) of two pure silkworm breeds, Pure Mysore (PM, a multivoltine breed) and $NB_4D_2$ (a bivoltine breed), and their hybrid, $PM{\times}NB_4D_2$ were introduced into the experimental conditions on the $3^{rd}$ day of oviposition till completion of hatching. The hatching rhythm was predominantly diurnal under all temperature and humidity conditions, with peaks just after 'lights-on' phase (6 hrs). Extreme temperature and humidity conditions did not alter the hatching rhythmicity, but prolonged the hatching durations, extending it to the next day, coupled with reduced hatching percentage in PM and $PM{\times}NB_4D_2{\cdot}In\;NB_4D_2$, on the other hand, hatching did not extend to the next day. Hatching percentage in this breed, however, reduced below the economic level under high temperature and low humidity conditions. The high temperature and low humidity together, though did not alter the rhythmicity, seems to exert synergetic effect on the hatching percentage and its duration in the silkworm, B. mori.

황색종 연초 건조중 황변기 온습도차가 잎담배 색상 및 화학성분에 미치는 영향 (EFFECT OF TEMPERATURE AND HUMIDITY ON THE LEAF COLOR AND CHEMICAL COMPONENTS DURING THE YELLOWING STAGE OF FLUE-CURING)

  • 황건중;석영선;이한석
    • 한국연초학회지
    • /
    • 제7권2호
    • /
    • pp.129-139
    • /
    • 1985
  • cent was carried out to study on the effect of temperature and humidity to chemical tobacco leaves during the yellowing stage. The results were follows : In the condition of high humidity and low temperature, yellowing time was delayed ; leaf color appeared lack clearness. In the higher temperature and the lower humidity during the yellowing stage : total sugar, reducing sugar and malic acid content were increased. Decomposition of nitrogenous components elevated in $38^{\circ}C$, 85%RH. Changes of total nitrogen content correlated with total curing time. Adecrease of linolenic acid with a corresponding increase of chlorogenic acid proceeded in the condition of low temperature and high humidity. In a view of tobacco quality by chemical components, the low temperature and high humidity during the yellowing stage decreased quality of tobacco leaves. It is considered to control of the proper condition of temperature and humidity during the yellowing.

  • PDF

다가구 주택 반지하세대의 주거환경 분석 - 장기 온·습도 모니터링 분석을 통한 실측결과를 중심으로 - (Analysis of Housing Environment in Semi Basement Multi-family Housing Units - Focuses on long-term analyzed measurements of temperature and humidity obtained from the housing units -)

  • 장건영;류동우
    • 대한건축학회논문집:구조계
    • /
    • 제34권2호
    • /
    • pp.83-90
    • /
    • 2018
  • This study was conducted to investigate the living environment of semi-basement housing units in multi-household houses. It analyzed measurements of temperature and humidity obtained from the housing units. For this study, temperature and humidity sensors were installed in 10 semi-basement housing units to measure interior temperature and humidity for 13 months. A survey was conducted to get information about the occurrence of dew condensation and mildew and to investigate residents' satisfaction level with the residential environment. According to the result, all the housing units under study had dew condensation and mildew. The average summer temperature of the 10 housing units was $27.84^{\circ}C$, and average humidity was 64.91%RH, while the average winter temperature was $20.6^{\circ}C$, and the average humidity was 40.12%RH. Depending on the condition of each housing unit, deviation was big. Residents' average level of satisfaction with the living condition was 2.03 which shows a low satisfaction (on a scale of 1-5 with 5 being completely satisfied.).

Mock-up 실험을 통한 황토벽과 전통창호의 실내 온습도 조절효과에 대한 비교평가 (A Comparison Evaluation on the Indoor Temperature and Humidity Control Effect of Hwang-To Brick and Traditional Window as Exterior envelops in Mock-up Room)

  • 송민정;신훈
    • KIEAE Journal
    • /
    • 제10권6호
    • /
    • pp.131-137
    • /
    • 2010
  • This study aims to know temperature and humidity handling ability of Hwang-To brick and traditional paper window's in mock-up room test. To achieve these goals, mock-up room test was carried out. The results are as follows. 1) There are no significant differences among specimen in temperature handling capacity. 2) Traditional paper windows are very sensitive when compared with glass window in humidity control. 3) Traditional paper windows have a big handling capacity in humidity control when vapors letting out in mock-up room. 4) Hwang-To brick case is more stable than other cases in relative humidity variances because it has more potential to contain humidity.