• Title/Summary/Keyword: Telemetry measuring system

Search Result 32, Processing Time 0.022 seconds

Development of pushing force measuring system for coke oven machines using telemetry method (비 접촉원격 토오크 측정 시스템 개발)

  • 전종학;허윤기;최일섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1778-1781
    • /
    • 1997
  • The coke oven plant on a steel works has not, in the past, been regarded as a prime user of modern instrument technology. The reason for this perception may be due to the fact that the basic design of the coke battery has been changed little over the years. The recording and analysis of oven pushing force on a routine basis is seen as a means of monitoring plant operation. A torque sensor is set up at the shaft of the rotor for measuring pushing force. Pushing force data which is communicated form torque sensor to staor by telemetry method are shown on MMI(Man-Machine Interface) screen and stored in the database automatically. Perhaps the most important feature is that is allows a problem oven to be identified at an early stage and for corrective action to be taken before it develops into a refusal to push. In this way the mechanical loads imposed on the battery structlure can be held to a necessary minimum, so helping to prolong its service life.

  • PDF

A Design of Telemetry Ground System for the Scientific Sounding Rocket KSR-420S (과학관측로케트 KSR-420S의 원격측정 지상시스템 설계)

  • 이수진;이재득;조광래;유장수
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.4
    • /
    • pp.26-32
    • /
    • 1991
  • Korea Aerospace Research Institute(KARI) performs research on developing the scientific sounding rocket(KSR-420S) for measuring ozone profile and atmosphere layer over korean peninsula. Informations about performances of flighting scientific rocket, that is temperature, strain, acceleration, pressure, rocket attitude and ranging data, and measuring data of ozone, ionosphere and X-ray are transmitted ground system by rocket onboard transmitting system. In this paper, the telemetry ground system which is compatible with the KSR-420S is designed for tracking the trajectory and receiving the incoming signals.

  • PDF

A VLSI Architecture Design of CDMA/TDMA Modem Chipsets for Wireless Telemetry Systems (CDMA/TDMA 기반 무선 원격계측 시스템용 모뎀의 VLSI 구조 설계)

  • 이원재;이성주;이서구;정석호;김재석
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.5
    • /
    • pp.107-114
    • /
    • 2004
  • In this paper, we present the architecture design of CDMA/TDMA modem chipset for wireless telemetry system. The wireless telemetry system a measuring data collecting system from many RTs(Remote Terminal) installed at the specific area using wireless communication technology. It consists of CU single CU (Central Unit) for collecting data and a large amount of RTs for transmitting the measuring data. We propose the hardware architecture of the modem for RT and CU. We also design those modem using Verilog HDL and synthesis them using Synopsys$^{TM}$ CAD tool. The modem of RT is implemented with 27K gates and that of CU is implemented around 220k gates using 0.6${\mu}{\textrm}{m}$ CMOS standard cell. The proposed system is implemented and tested using Altera$^{TM}$ FPGA.PGA.

Development for body temperature sensor and monitoring telemetry system (체온측정용 온도 센서 및 모니터링 텔레메트리 시스템 구현)

  • Lee, Jyung-Hyun;Seong, Ki-Woong;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.435-442
    • /
    • 2010
  • Typically, the vital signs that are representing the state of human body, are the body temperature, sphygmus, respiration and blood pressure. The body temperature is the result of metabolic regulation and human steady-state body temperature is maintained from 35.9 to $37.4^{\circ}C$ by heat regulatory center. The body temperature is indicative of infection and especially it should be monitored to requiring intensive care patients or after surgical patients. But, measuring of body temperature to a heavy workload on nursing staff has been recognized. And, the health service of nurse is limited by simple tasks such as the measurement and record of vital sign. In this paper, the body temperature monitoring telemetry system was proposed to prove the recoding and transmission of body temperature patch system according the standard(ISO TS11073-92001). We proposed the transmission protocol to suit the MFER(medical waveform format encoding rules). The telemetry patch system was implemented and it was verified by experiments.

Result and Analysis of Performance Test of Pantograph for High Speed Train (고속전철 집전장치의 성능 계측 결과 및 분석)

  • Seo Sung-Il;Park Choon-Soo;Cho Yong-Hyun;Mok Jin-Yong;Kang Bu-Byung
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.574-579
    • /
    • 2003
  • In this study, a measuring system for performance of pantograph was developed. The measuring system was installed on the prototype high speed train and measurement has been conducted during running on the test track. The measuring system is composed of video monitoring system and telemetry & data processing system. It can monitor the hazard behavior of pantograph and measure acceleration and vertical force of the pan head. Owing to the measuring system, performance of pantograph and safety of interface system of pantograph and catenary is evaluated.

  • PDF

Development of Tracking System for High Maneuvering Vehicle (고기동 비행체를 위한 추적시스템 개발)

  • Cho, Dong-Sik;Rha, Sung-Woong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.399-406
    • /
    • 2008
  • Tracking system is developed to receive both telemetry data and video data which are transmitted by radio frequency for the flight test of high manuvering vehicle. Tracking method of tracking system is the phase comparative monopulse that produce tracking data by measuring the phase difference of signal which is received by four patch antennas. The performance of tracking system is verified by flight test for RC helicopter and rocket.

Implementation of Implantable Bluetooth Bio-telemetry System for Transmitting Acoustic Signals in the Body with Wireless Recharging Function (무선 충전 가능한 블루투스 방식의 체내 음향신호 전송용 이식형 바이오 텔레메트리 시스템 구현)

  • Lee, Sang-June;Kim, Myoung Nam;Lee, Jyung Hyun;Lim, Hyung-Gyu;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.5
    • /
    • pp.652-662
    • /
    • 2015
  • It is necessary to develop small, implantable bio-telemetry systems which can measure and transmit patients' bio-signals from internal body to external receiver. When measuring bio-signals, like electrical bio-signals, acoustic bio-signal measurement has also a big clinical usefulness. But, sound signal has larger frequency bandwidth than any other bio-signals. When considering these issues, a wireless telemetry system which has rapid data transmission rate proportional to wide frequency bandwidth is necessary to be developed. The bluetooth module is used to overcome the data rate limitation caused by the large frequency bandwidth. In this paper, a novel multimedia bluetooth biotelemetry system was developed which consists of transmitter module located in the body and receiver device located outside of the body. The transmitter consists of microphone, bluetooth, and wireless charging device. And the receiver consists of bluetooth and codec system. The sound inside the skin is captured by microphone and sent to receiver by bluetooth while charging. The wireless charging system constantly supplies the electric power to the system. To verify the performance of the developed system, an in vitro experiment has been performed. The results show that the proposed biotelemetry system has ability to acquire the sound signals under the skin.

Convective heat transfer on the rotor fan and endring of the TEFC induction motor with telemetry system (무선계측기를 이용한 회전자팬 및 엔드링에서의 대류 열전달)

  • Yun, Myeong-Geun;Ha, Gyeong-Pyo;Go, Sang-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.510-519
    • /
    • 1998
  • Recently, computer modelling is increasingly used as a design tool, which requires more detailed data for heat transfer coefficients in various regions of the induction motor. But there are little information about those of rotor fan and endring because of difficulty in measuring signals in rotating bodies. In the present studies, the temperature signals were precisely measured with self-developed telemetry system, which had multi-channels and high rotational speed. After some losses were compensated, the heat transfer coefficients of the rotor endring and fan surfaces were measured. Minimum heat transfer region was existed with endcap plate distance and maximum heat transfer was found at some rotor fan width. It was also studied that how the guide plate and endcap inside rib effected on the rotor heat transfer. The higher heat transfer were obtained with decreasing guide plate distance, increasing the number and height of endcap inside rib. The correlation equations of the results were obtained and compared with others. Above results of the heat transfer coefficients can be used as basic data for cooling design of the various kind of motors.

A Study on the Validation of Tracking Performance of a Big Parabola Antenna System (대형 접시형 안테나 추적성능 검증에 관한 연구)

  • Oh, Chang-Yul;Oh, Seung-Hyeub
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.77-82
    • /
    • 2010
  • The tracking performance of the big tracking antenna system using Radio Frequency is very important for the tracking and position measuring for the flight vehicle, but the precise measuring of the tracking performance is not easy, especially for the big antenna system such as ground telemetry antenna or tracking radar in space application because it's characteristics could be different in accordance with the antenna direction. In this paper, the error factors impacting on the tracking performance (pointing accuracy and tracking accuracy) and the ranges of each factor are reviewed, and the simple and efficient method to measure the tracking performance is introduced which using low earth orbit as the signal source. Finally, the measurement results for the telemetry ground antenna in NARO Space Center are reviewed.

Telemetry capsule for pressure monitoring in the gastrointestinal tract (소화관 내 압력 측정을 위한 텔레메트리 캡슐 구현)

  • Yoon, Ki-Won;Woo, Sang-Hyo;Lee, Jyung-Hyun;Moon, Yeon-Kwan;Park, Hee-Joon;Won, Chul-Ho;Kim, Byung-Kyu;Choi, Hyun-Chul;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.211-218
    • /
    • 2005
  • As the cause and the treatment about gastrointestinal disease has been issued recently, the importance of measuring the pressure in the gastrointestinal tract has been increased. However, the conventional measurement methods of the pressure in the gastrointestinal tract cause the patients' pain and inconvenience as well as an inaccurate pressure measurement. In this paper, the pressure monitoring telemetry system has been designed and implemented for an accurate pressure measurement inside the gastrointestinal tract with minimizing pain and inconvenience. The pressure monitoring telemetry system is composed of a pressure measurement capsule and an external receiver. The capsule has been miniaturized into the same size of a vitamin tablet so that the capsule can be swallowed through the oral cavity. After the capsule acquires and encodes the pressure data in the gastrointestinal tract, the encoded pressure data are modulated by frequency shift keying (FSK) and transmitted with ultrahigh frequency (UHF) band signal to the outside of a body. The performance of the telemetry capsule for monitoring pressure in the gastrointestinal tract is demonstrated by the results of animal in-vivo experiments.